05000029/LER-1986-012, Forwards LER 86-012-00 Re Plant Trip on Low Steam Generator Level Due to Loss of Control Air

From kanterella
(Redirected from 05000029/LER-1986-012)
Jump to navigation Jump to search
Forwards LER 86-012-00 Re Plant Trip on Low Steam Generator Level Due to Loss of Control Air
ML20214J207
Person / Time
Site: Yankee Rowe
Issue date: 11/03/1986
From: St Laurent N
YANKEE ATOMIC ELECTRIC CO.
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
NUDOCS 8612010206
Download: ML20214J207 (1)


LER-2086-012, Forwards LER 86-012-00 Re Plant Trip on Low Steam Generator Level Due to Loss of Control Air
Event date:
Report date:
0292086012R00 - NRC Website

text

- ---

k .~ .

YA NKEE ATOMIC ELECTRIC COMPANY r.i. n n. u sa> m m e, Star Route, Rowe, Massachusetts 01367

,YAuxme

~ .

November 3, 1986 U.S. Nuclear Regulatory Commissien Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 Attention: Dr. Thomas E. Murley, Regional Administrator

Subject:

Licensee Event Report 50-29/86-12 Plant T.ip on Low SG Level Due to Loss of Control Air

Dear Sir:

In accordance with 10 CFR 50.73(a)(2)(iv), the attached Licensee Event Report is hereby submitted.

Very truly yours, hNormand

~-fN.lSt. Laurent I

Q4t Plant Superintendent LDF/nm Enclosure cc: [3] NSARC Chairman (YAEC)