Forwards Responses to Draft SER Open Items 156 & 157 Re Main Condenser Evacuation Sys (Mces) Capacity & Mces Quality Group Correlation W/Reg Guide 1.26 Group D
ML18003A885
Person / Time
Site: Harris  Duke Energy icon.png
Issue date: 06/02/1983
From: Mcduffie M
CAROLINA POWER & LIGHT CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
LAP-83-159, NUDOCS 8306080032
Download: ML18003A885 (7)


Text

~.r r REGULATO INFORMATION DISTRIBUTION STEM (RIDS)

'ACCESSION NBR:8306080032 DOC DATE: 83/06/02 NOTARIZED: NO DOCKET Unit ii Carolina

~

FACIL:50-400 Shearon Harris Nuclear Power Planti 05000400 50-401 Shearon Harris Nuclear Power Planti BYNAME Unit 2, Carolina 05000401

'AUTH AUTHOR AFFILIATION MCDUFFIEiM>A, Carolina Power L Light Co ~

>RECIP ~ NAME RECIPIENT AFFILIATION DENTONiH ~ RE Office of Nuclear Reactor Regulationr Director

SUBJECT:

Forwards responses to draft SER Open Items 156 8 157 re main condenser evacuation sys (MCES) capacity E MCGS quality group correlation w/Reg Guide 1 ~ 26 Group DE r

1 DI'STRIBUTION CODE: B001S .COPIES RECEIVED'LTR ENCL SIZE, TITLE; Licensing Submittal: PSAR/FSAR Amdts L Related Correspondence'OTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL NRR/DL/ADL 1 0 NRR LB3 BC 1 0 NRR LB3 LA 1 0 KADAMBIiP 01 1 1 INTERNAL+ ELD/HDS1 1 0 IE FILE 1 1 IE/DEPER/EPB 36 3 3 IE/DEPER/IRB 35 1 1 IE/DEQA/QAB 21 1 1 NRR/DE/AEAB 1 0 NRR/DE/CEB 11 1 1 NRR/DE/EHEB 1 NRR/DE/EQB 13 2 2 NRR/DE/GB 28 2 2 NRR/DE/MEB 18 1 1 NRR/DE/MTEB 17 1 1 NRR/DE/SAB 2g 1 1 NRR/DE/SGEB 25 2 2' NRR/DE/SGEB NRR/DHFS/HFEB40 1 NRR/DHFS/LQB 32 1 1 NRR/DHFS/PSRB 1 1 NRR/DL/SSPB 1 0 NRR/DS I/AEB 26 1 1-NRR/DS I/ASB 1 1 NRR/DS I/CPB 10 1 NRR/DSI/CSB 09 1 1 NRR/DS I/ICS8 16 1 1 NRR/DS I/METB 12 1 1 NRR/DS I/PSB 19 1 N AB 22 1 NRR/DS I/RSB 23 1 1 REG FILE 04 1 1 RGN2 "3 3

/MIB 1 0 EXTERNAL: ACRS . 41 6 6 BNL(AMDTS ONLY) 1 DMB/DSS (AMDTS) 1 1 FEMA REP DIV 39 1 LPDR 05 1 1 NRC PDR 02 1 NSIC 05 1 1 NTIS ,: i

>TOTAL NUMBER OF COPIES REQUIRED: LTTR 55 ENCL 48

M I C W M H

'W tl II I,II M H c)

I r

MI ~

I) ( p I H

lh.

W 14

SERIAL: LAP-83-159 Carolina Power & Light Company JUN Pg ~98p Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, DC 20555 SHEARON HARRIS NUCLEAR POWER PLANT UNIT NOS. 1 AND 2 DOCKET NOS. 50-400 AND 50-401 DRAFT SAFETY EVALUATION REPORT RESPONSES METEOROLOGICAL & EFFLUENTS TREATMENT BRANCH

Dear Mr. Denton:

Carolina Power & Light Company (CP&L) hereby transmits one original and forty copies of the responses to the Shearon Harris Nuclear Power Plant Draft Safety Evaluation Report (DSER) CPAL Open Item Nos. 156 and 157.

Carolina Power & Light Company will be providing responses to other Open Items in the DSER shortly.

Yours very truly, M. A. McDuffie Senior Vice President Engineering I Construction PS/pgp (6787PSA)

Enclosure cc: Mr. Jack Hayes (NRC-METB) Mr. Wells Eddleman Mr. N. Prasad Kadambi (NRC) Dr. Phyllis Lotchin Mr. G. F. Maxwell (NRC-SHNPP) Mr. John D. Runkle Mr. J. P. O'Reilly (NRC-RII) Dr. Richard D. Wilson Mr. Travis Payne (KUDZU) Mr. G. O. Bright (ASLB)

Mr. Daniel F. Read (CHANGE/ELP) Dr. J. H. Carpenter (ASLB)

Chapel Hill Public Library Mr. J. L. Kelley (ASLB)

Wake County Public Library 830602 8306080032 05000400 PDR ADOCK PDR 411 Fayettevllle Street o P. O. Box 1551 ~ Raleigh, N. C. 27602

~ ~ ~ I>> (t 1>>

t'l'

=* I

'I II t A

(

h n

1

~ 0 w II l

. III I

SHEARON HARRIS NUCLEAR POWER PLANT DRAFT SAFETY EVALUATION REPORT (DSER) 0 en Item 156 (DSER Section 10.4.2 a e 10-9)

Justify the fact that the capacity for the Main Condenser Evacuation System (MCES) is not consistent with the guidelines of the "Standard for Steam Surface Condensers."

~Res onse The determination of the venting capacity of the MCES was based on the design of the main condenser as described in Section 10.4.1.2. For one condenser shell with two exhaust openings, and an effective steam flow for each main exhaust opening of 3,000,001 to 4,000,000 lbs/hr, the venting capacity required was determined from Table ST-4 of the 1970, 6th Edition of the Standards for Steam Surface Condensers as required by SRP 10.4.2. The venting capacity required by the Heat Exchangers Institute standard was determined to be 30 scfm.

SHEARON HARRIS NUCLEAR POWER PLANT DRAFT SAFETY EVALUATION REPORT (DSER) 0 en Item 157 (DSER Section 10.4.2 age 10-9)

Correlation of quality group classification to which the Hain Condenser Evacuation System (MCES) is designed with the Quality Group D designation presented in Regulatory Guide 1.26.

~Res ense The HCES mechanical vacuum pumps, piping, valves and strainers are designed to ANSI B31.1 and/or manufacturer standards as applicable and correlate with Quality Group D of Regulatory Guide 1.26. The HCES is a non-nuclear safety, non-seismic Category I system.

The Condenser Vacuum Pump Effluent Treatment System (CVPETS) is a non-nuclear safety, nonmeismic Category I designed ventilation cleanup system, and is not part of the radioactive waste management system. Regulatory Guide 1.26 does not apply to ventilation systems and, therefore, the CVPETS is not classified Quality Group D.

gl h

II f'

P 4

~ ~