ML17332A841: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
(4 intermediate revisions by the same user not shown)
Line 3: Line 3:
| issue date = 06/30/1995
| issue date = 06/30/1995
| title = Monthly Operating Repts for June 1995 for Donald C Cook Nuclear Unit 2.W/950706 Ltr
| title = Monthly Operating Repts for June 1995 for Donald C Cook Nuclear Unit 2.W/950706 Ltr
| author name = BLIND A A, BUSSONE G F, TURNER J
| author name = Blind A, Bussone G, Turner J
| author affiliation = INDIANA MICHIGAN POWER CO.
| author affiliation = INDIANA MICHIGAN POWER CO.
| addressee name =  
| addressee name =  
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:PRIORITY.1(ACCELERATEDRZDSPROCESSZNG)REGULATORYINFORMATIONDISTRIBUTIONSYSTEM(RIDS)'ACCESSIOSNBR:9507140138DOC.DATE:95/06/30NOTARIZED:NODOCKETIFACIL:50-316DonaldC.CookNuclearPowerPlant,Unit2,IndianaM05000316PAUTH.NAMEAUTHORAFFILIATIONTURNER,J.IndianaMichiganPowerCo.BUSSONE,G.F.IndianaMichiganPowerCo.BLIND,A.A.IndianaMichiganPowerCo.RECIP.NAMERECIPIENTAFFILIATIONI
{{#Wiki_filter:PRIORITY                   .1 (ACCELERATED RZDS PROCESSZNG)
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSIOS NBR: 9507140138          DOC. DATE: 95/06/30      NOTARIZED: NO          DOCKET  I FACIL:50-316 Donald C. Cook Nuclear Power Plant, Unit 2, Indiana M                  05000316  P AUTH. NAME            AUTHOR AFFILIATION TURNER,J.             Indiana Michigan Power Co.
BUSSONE,G.F.           Indiana Michigan Power Co.
BLIND,A.A.             Indiana Michigan Power Co.
RECIP.NAME            RECIPIENT AFFILIATION                                                I


==SUBJECT:==
==SUBJECT:==
MonthlyoperatingreptsforJune1995forDonaldCCookNuclearUnit2.W/950706ltr.DISTRIBUTIONCODE:IE24DCOPIESRECEIVED:LTR(ENCL(SIZE:TITLE:MonthlyOperatingReport(perTechSpecs)NOTESRECIPIENTIDCODE/NAME'PD3-1PDINTERNAL:AEOD/SPD/RRABNRR/DISP/PIPBRGN3EXTERNAL:LITCOBRYCE,JHNRCPDRCOPIESLTTRENCL111111111111RECIPIENTIDCODE/NAMEHICKMAN,JCNRR/DOPS/OECBNOACCOPIESLTTRENCL11111111NNOTETOALL"RZDS"RECZPZENTS:PLEASEHELPUSTOREDUCEWASTE!CONTACTTHEDOCUMENTCONTROLDESK,ROOMOWFN5DS(415-2083)TOELZMZNATEYOURNAMEFROMDZSTRZBUTZONLZSTSFORDOCUMENTSYOUDON'TNEED!TOTALNUMBEROFCOPIESREQUIRED:LTTR10ENCL10 IndianaMichigan~PowerCompanyCookNuclearPlantOneCookPlace'ridgman,Ml491066164655901July6,1995U.S.NuclearRegulatoryCommissionATTN:DocumentControlDeskWashington,D.C.20555Gentlemen:PursuanttotherequirementsofDonaldC.CookNuclearPlantUnit2TechnicalSpecification6.9.1.10,theattachedMonthlyOperatingReportforthemonthofJune1995issubmitted.Respectfully,.A.BlindPlantManagerAttachmentc:NRCRegionIIID.R.HahnR.C.CallenS.HammingJ.G.KepplerINPORecordsCenterANINuclearEngineeringDepartmentE.E.FitzpatrickW.G.Smith,Jr.S.J.BrewerD.W.PaulS.H.SteinhartJ.L.LeichnerJ.A.IsomD.G.TurnerE.A.SmarrellaM.E.Russo9507140138950630PDRADDCK05000316RPDR N.R.C.RATINGDATAREPORTDOCKETNO.50-316DATE03/Jul/95.COMPLETEDBYJanisse/TurnerTELEPHONE616-465-5901OPERATINGSTATUS1.UnitNameD.C.CookUnit22.ReportingPeriodJune19953.LicensedThermalPower(MWt)34114.NamePlateRating(GrossMWe)11335.DesignElectricalRating(NetMWe)10906.MaximumDependableCapacity(GROSSMWe)11007.MaximumDependableCapacity(NetMWe)1060notes8.IfChangesOccurinCapacityRatings(Itemsno.3through7)SinceLastReportGiveReasons9.PowerLevelToWhichRestricted.If-Any(NetMWe)10.ReasonsForRestrictions.IfAny:11.12.13.14.15.16.17.18.19.20.21.22.23.24.HoursinReportingPeriodNo.ofHrs.ReactorWasCriticalReactorReserveShutdownHoursHoursGeneratoronLineUnitReserveShutdownHoursGrossTherm.EnergyGen.(MWH)GrossElect.EnergyGen.(MWH)NetElect.EnergyGen.(MWH)UnitServiceFactorUnitAvailabilityFactorUnitCapacityFactor(MDCNet)UnitCapacityFactor(DERNet)UnitForcedOutageRate'hutdownsScheduledoverNextSix'oneThisMo.Yr.toDate720.04344.0720.04208.70.00.0720.04204.20.00.024476351392987278036045353507543404384388100.096.8100.096.898.895.296.192.60.03.2Months(Type,Date,andCumm.153360.0104225.20.0100739;30.0308028053998423409614182366.766.760.058.415.3Duration):25.IfShutDownAtEndofReportPeriod,EstimatedDateofStartup:26.UnitsinTestStatus(PriortoCommercialOperation):ForecastINITIALCRITICALITYINITIALELECTRICITYCOMMERCIALOPERATIONAchieved 1'
Monthly operating repts        for June  1995  for  Donald  C  Cook Nuclear Unit 2.W/950706        ltr.
DOCKETNO.50-316UNITTWODATE03/Jul/95COMPLETEDBYJanisse/TurnerTELEPHONE616-465-5901DAYMONTHAVERAGEDAILYPOWERLEVELJune1995DAYAVERAGEDAILYPOWERLEVEL95/06/0195/06/0295/06/0395/06/0495/06/0595/06/0695/06/07'95/06/0895/06/0995/06/1095/06/1195/06/1295/06/1395/06/1495/06/1595/06/1610571054105210541051104910421063106310531047102710331033,1028102995/06/1795/06/1895/06/1995/06/2095/06/2195/06/2295/06/23'5/06/2495/06/2595/06/2695/06/2795/06/2895/06/2995/06/3010461046103510381061105210551052105410621058104810491040 DOCKETNO:UNITNAMECOMPLETEDBY:TELEPHONE:DATE'AGE:50-316D.C.CookUnit2G.F.Bussone616-465-5901July6,1995Page1of1MONTHLYOPERATINGACTIVITIES-JUNE1995HIGHLIGHTSTheunitenteredthisreportingperiodinMode1at100%RTP.TheunitexitedthisreportingperiodinMode1at100%RTP.Therewerenochallengestothepressurizersafetyvalvesorpoweroperatedreliefvalves.GrosselectricalgenerationforthemonthofJunewas780360MWH.DETAILSNodetailstoreport.
DISTRIBUTION CODE: IE24D          COPIES RECEIVED:LTR       ( ENCL ( SIZE:
UNITSHUTDOWNSANDPOWERREDUCTIONSREPORTMONTH:JUNE1995UNITNAME:DATE:COMPLETEDBYTELEPHONE:PAGE:D.C.COOKUNITJuly6,.1995G~F.Bussone616-46P-5901Page1OF1DURATIONNO.DATETYPEHOURSMETHODOFSHUTTINGLICENSEEDOWNEVENTSYSTEMCOMPONENTCAUSEANDCORRECTIVEACTIONREASONREACTORREPORTNO.CODECODETOPREVENTRECURRENCETherewerenounitshutdownsorsignificantpowerreductionsfro~100'hRTPthismonth.1F:ForcedS:Scheduled2Reason:A:EquipmentFailure(Explain)B:MaintenanceorTestC:RefuelingD:RegulatoryRestrictionE:OperatorTrainingandLicenseExaminationF:AdministrativeG:OperationalError(Explain)H:Other(Explain)3Method:1:Manual2:ManualScram3:AutomaticScram4:Other(Explain)ExhibitG-InstructionsforpreparationofdataentrysheetsforLicenseeEventReport(LER)File(NUREG0161)5ExhibitI:SameSource}}
TITLE: Monthly Operating Report (per Tech Specs)
NOTES RECIPIENT            COPIES            RECIPIENT            COPIES ID    CODE/NAME       LTTR ENCL        ID  CODE/NAME      LTTR ENCL
          'PD3-1 PD                  1    1      HICKMAN,J                1      1 INTERNAL: AEOD/SPD/RRAB                1    1            C                  1      1 NRR/DISP/PIPB              1    1      NRR/DOPS/OECB            1      1 RGN3                      1    1 EXTERNAL: LITCO BRYCE,J H              1    1      NOAC                    1      1 NRC PDR                    1    1 N
NOTE TO ALL "RZDS" RECZPZENTS:
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM OWFN 5DS (415-2083) TO ELZMZNATE YOUR NAME FROM DZSTRZBUTZON LZSTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED: LTTR              10  ENCL    10
 
Indiana Michigan Power Company
                              ~
Cook Nuclear Plant One Cook Place Ml 49106
                    'ridgman, 616 465 5901 July 6,         1995 U.S. Nuclear Regulatory Commission ATTN:         Document          Control Desk Washington,                 D.C. 20555 Gentlemen:
Pursuant to the requirements of Donald C. Cook Nuclear Plant Unit 2 Technical Specification 6.9.1.10, the attached Monthly Operating Report for the month of June 1995    is submitted.
Respectfully,
      .A. Blind Plant Manager Attachment c:       NRC D.R. Hahn Region    III R.C. Callen S .             Hamming J.G. Keppler INPO Records Center ANI Nuclear Engineering Department E.E.             Fitzpatrick W.G. Smith,             Jr.
S.J. Brewer D.W. Paul S.H. Steinhart J.L. Leichner J.A. Isom D.G. Turner E.A. Smarrella M.E. Russo 9507140138 950630 PDR  ADDCK 05000316 R                              PDR
 
N.R.C. RATING DATA REPORT DOCKET NO.     50-316 DATE 03/Jul/95.
COMPLETED BYJanisse/Turner TELEPHONE 616-465-5901 OPERATING STATUS
: 1. Unit Name                                D. C. Cook        Unit  2
: 2. Reporting Period                                            June 1995 notes
: 3. Licensed Thermal Power (MWt)                                     3411
: 4. Name Plate Rating (Gross MWe)                                   1133
: 5. Design Electrical Rating (Net MWe)                               1090
: 6. Maximum Dependable Capacity (GROSS MWe) 1100
: 7. Maximum Dependable Capacity (Net MWe)                           1060
: 8. If Changes Occur in Capacity Ratings (Items                            no. 3 through 7) Since Last Report Give Reasons
: 9. Power Level To Which Restricted. If-Any (Net                            MWe)
: 10. Reasons For Restrictions.                   If Any:
This  Mo. Yr. to Date    Cumm.
: 11. Hours  in Reporting Period                                    720.0        4344.0    153360.0
: 12. No. of Hrs. Reactor                Was  Critical              720.0        4208.7    104225.2
: 13. Reactor Reserve Shutdown Hours                                    0.0            0.0        0.0
: 14. Hours Generator on Line                                        720.0        4204.2    100739;3
: 15. Unit Reserve Shutdown Hours                                      0.0          0.0          0.0
: 16. Gross Therm. Energy Gen. (MWH)                             2447635      13929872    308028053
: 17. Gross Elect. Energy Gen. (MWH)                               780360        4535350    99842340
: 18. Net Elect. Energy Gen. (MWH)                                 754340        4384388    96141823
: 19. Unit  Service Factor                                          100.0          96.8        66.7
: 20. Unit  Availability Factor                                      100.0          96.8        66.7
: 21. Unit  Capacity Factor                (MDC  Net)                98.8          95.2        60.0
: 22. Unit  Capacity Factor                (DER  Net)                96.1          92.6        58.4
: 23. Unit  Forced Outage                                              0.0          3.2        15.3
: 24.             Scheduled over Next Rate'hutdowns Six'one Months (Type, Date,and    Duration):
: 25. If Shut  Down At  End              of Report Period, Estimated Date of Startup:
: 26. Units in Test Status (Prior to Commercial Operation):
Forecast    Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION
 
1' DOCKET NO.           50-316 UNIT                    TWO DATE            03/Jul/95 COMPLETED  BYJanisse/Turner TELEPHONE    616-465-5901 MONTH          June 1995 AVERAGE DAILY                            AVERAGE DAILY DAY      POWER LEVEL              DAY            POWER LEVEL 95/06/01        1057              95/06/17            1046 95/06/02        1054              95/06/18            1046 95/06/03        1052              95/06/19            1035 95/06/04        1054              95/06/20            1038 95/06/05        1051              95/06/21            1061 95/06/06        1049              95/06/22            1052 95/06/07        1042              95/06/23            1055
'95/06/08        1063            '5/06/24              1052 95/06/09        1063              95/06/25              1054 95/06/10        1053              95/06/26              1062 95/06/11        1047              95/06/27              1058 95/06/12        1027              95/06/28              1048 95/06/13        1033              95/06/29              1049 95/06/14        1033              95/06/30              1040 95/06/15        ,1028 95/06/16        1029
 
DOCKET NO:       50-316 UNIT NAME        D.C. Cook Unit    2 COMPLETED BY:    G.F. Bussone TELEPHONE:        616-465-5901 DATE'AGE:
July  6, 1995 Page  1 of 1 MONTHLY OPERATING ACTIVITIES    JUNE  1995 HIGHLIGHTS The  unit entered this reporting period in Mode 1 at 100% RTP.
The  unit exited this reporting period in Mode 1 at 100% RTP.
There were no challenges  to the pressurizer safety valves or power operated  relief valves.
Gross  electrical generation for the  month    of June was 780360    MWH.
DETAILS No  details to report.
 
UNIT SHUTDOWNS AND  POWER REDUCTIONS                                UNIT NAME:       D.C. COOK UNIT DATE:            July 6,. 1995 REPORT MONTH: JUNE  1995                                      COMPLETED BY    G~ F. Bussone TELEPHONE:      616-46P-5901 PAGE:            Page 1 OF 1 METHOD OF SHUTTING    LICENSEE DURATION              DOWN        EVENT      SYSTEM COMPONENT      CAUSE AND CORRECTIVE ACTION NO. DATE  TYPE      HOURS      REASON    REACTOR    REPORT NO. CODE  CODE          TO PREVENT RECURRENCE There were no unit shutdowns or significant power reductions 100'h RTP this month.
fro~
1                2                                    3                                                  5 F: Forced        Reason:                               Method:            Exhibit  G  Instructions      Exhibit I:   Same S: Scheduled    A:   Equipment Failure (Explain)     1: Manual          for preparation of data                      Source B:   Maintenance or Test              2: Manual Scram    entry sheets for Licensee C:   Refueling                        3: Automatic Scram Event Report (LER) File D:   Regulatory Restriction          4: Other (Explain) (NUREG  0161)
E:   Operator Training and License Examination F:   Administrative G:   Operational Error (Explain)
H:   Other (Explain)}}

Latest revision as of 00:19, 4 February 2020

Monthly Operating Repts for June 1995 for Donald C Cook Nuclear Unit 2.W/950706 Ltr
ML17332A841
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 06/30/1995
From: Blind A, Bussone G, Joseph Turner
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9507140138
Download: ML17332A841 (7)


Text

PRIORITY .1 (ACCELERATED RZDS PROCESSZNG)

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSIOS NBR: 9507140138 DOC. DATE: 95/06/30 NOTARIZED: NO DOCKET I FACIL:50-316 Donald C. Cook Nuclear Power Plant, Unit 2, Indiana M 05000316 P AUTH. NAME AUTHOR AFFILIATION TURNER,J. Indiana Michigan Power Co.

BUSSONE,G.F. Indiana Michigan Power Co.

BLIND,A.A. Indiana Michigan Power Co.

RECIP.NAME RECIPIENT AFFILIATION I

SUBJECT:

Monthly operating repts for June 1995 for Donald C Cook Nuclear Unit 2.W/950706 ltr.

DISTRIBUTION CODE: IE24D COPIES RECEIVED:LTR ( ENCL ( SIZE:

TITLE: Monthly Operating Report (per Tech Specs)

NOTES RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL

'PD3-1 PD 1 1 HICKMAN,J 1 1 INTERNAL: AEOD/SPD/RRAB 1 1 C 1 1 NRR/DISP/PIPB 1 1 NRR/DOPS/OECB 1 1 RGN3 1 1 EXTERNAL: LITCO BRYCE,J H 1 1 NOAC 1 1 NRC PDR 1 1 N

NOTE TO ALL "RZDS" RECZPZENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM OWFN 5DS (415-2083) TO ELZMZNATE YOUR NAME FROM DZSTRZBUTZON LZSTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED: LTTR 10 ENCL 10

Indiana Michigan Power Company

~

Cook Nuclear Plant One Cook Place Ml 49106

'ridgman, 616 465 5901 July 6, 1995 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Gentlemen:

Pursuant to the requirements of Donald C. Cook Nuclear Plant Unit 2 Technical Specification 6.9.1.10, the attached Monthly Operating Report for the month of June 1995 is submitted.

Respectfully,

.A. Blind Plant Manager Attachment c: NRC D.R. Hahn Region III R.C. Callen S . Hamming J.G. Keppler INPO Records Center ANI Nuclear Engineering Department E.E. Fitzpatrick W.G. Smith, Jr.

S.J. Brewer D.W. Paul S.H. Steinhart J.L. Leichner J.A. Isom D.G. Turner E.A. Smarrella M.E. Russo 9507140138 950630 PDR ADDCK 05000316 R PDR

N.R.C. RATING DATA REPORT DOCKET NO. 50-316 DATE 03/Jul/95.

COMPLETED BYJanisse/Turner TELEPHONE 616-465-5901 OPERATING STATUS

1. Unit Name D. C. Cook Unit 2
2. Reporting Period June 1995 notes
3. Licensed Thermal Power (MWt) 3411
4. Name Plate Rating (Gross MWe) 1133
5. Design Electrical Rating (Net MWe) 1090
6. Maximum Dependable Capacity (GROSS MWe) 1100
7. Maximum Dependable Capacity (Net MWe) 1060
8. If Changes Occur in Capacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons
9. Power Level To Which Restricted. If-Any (Net MWe)
10. Reasons For Restrictions. If Any:

This Mo. Yr. to Date Cumm.

11. Hours in Reporting Period 720.0 4344.0 153360.0
12. No. of Hrs. Reactor Was Critical 720.0 4208.7 104225.2
13. Reactor Reserve Shutdown Hours 0.0 0.0 0.0
14. Hours Generator on Line 720.0 4204.2 100739;3
15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross Therm. Energy Gen. (MWH) 2447635 13929872 308028053
17. Gross Elect. Energy Gen. (MWH) 780360 4535350 99842340
18. Net Elect. Energy Gen. (MWH) 754340 4384388 96141823
19. Unit Service Factor 100.0 96.8 66.7
20. Unit Availability Factor 100.0 96.8 66.7
21. Unit Capacity Factor (MDC Net) 98.8 95.2 60.0
22. Unit Capacity Factor (DER Net) 96.1 92.6 58.4
23. Unit Forced Outage 0.0 3.2 15.3
24. Scheduled over Next Rate'hutdowns Six'one Months (Type, Date,and Duration):
25. If Shut Down At End of Report Period, Estimated Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

1' DOCKET NO. 50-316 UNIT TWO DATE 03/Jul/95 COMPLETED BYJanisse/Turner TELEPHONE 616-465-5901 MONTH June 1995 AVERAGE DAILY AVERAGE DAILY DAY POWER LEVEL DAY POWER LEVEL 95/06/01 1057 95/06/17 1046 95/06/02 1054 95/06/18 1046 95/06/03 1052 95/06/19 1035 95/06/04 1054 95/06/20 1038 95/06/05 1051 95/06/21 1061 95/06/06 1049 95/06/22 1052 95/06/07 1042 95/06/23 1055

'95/06/08 1063 '5/06/24 1052 95/06/09 1063 95/06/25 1054 95/06/10 1053 95/06/26 1062 95/06/11 1047 95/06/27 1058 95/06/12 1027 95/06/28 1048 95/06/13 1033 95/06/29 1049 95/06/14 1033 95/06/30 1040 95/06/15 ,1028 95/06/16 1029

DOCKET NO: 50-316 UNIT NAME D.C. Cook Unit 2 COMPLETED BY: G.F. Bussone TELEPHONE: 616-465-5901 DATE'AGE:

July 6, 1995 Page 1 of 1 MONTHLY OPERATING ACTIVITIES JUNE 1995 HIGHLIGHTS The unit entered this reporting period in Mode 1 at 100% RTP.

The unit exited this reporting period in Mode 1 at 100% RTP.

There were no challenges to the pressurizer safety valves or power operated relief valves.

Gross electrical generation for the month of June was 780360 MWH.

DETAILS No details to report.

UNIT SHUTDOWNS AND POWER REDUCTIONS UNIT NAME: D.C. COOK UNIT DATE: July 6,. 1995 REPORT MONTH: JUNE 1995 COMPLETED BY G~ F. Bussone TELEPHONE: 616-46P-5901 PAGE: Page 1 OF 1 METHOD OF SHUTTING LICENSEE DURATION DOWN EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION NO. DATE TYPE HOURS REASON REACTOR REPORT NO. CODE CODE TO PREVENT RECURRENCE There were no unit shutdowns or significant power reductions 100'h RTP this month.

fro~

1 2 3 5 F: Forced Reason: Method: Exhibit G Instructions Exhibit I: Same S: Scheduled A: Equipment Failure (Explain) 1: Manual for preparation of data Source B: Maintenance or Test 2: Manual Scram entry sheets for Licensee C: Refueling 3: Automatic Scram Event Report (LER) File D: Regulatory Restriction 4: Other (Explain) (NUREG 0161)

E: Operator Training and License Examination F: Administrative G: Operational Error (Explain)

H: Other (Explain)