05000315/LER-1999-003, :on 990107,CR Pressurization Sys Surveillance Test Did Not Test Sys in Normal Operating Condition.Caused by Failure to Recognize Door 12DR-AUX415 as Part of CR Pressure Boundary.Performed Walkdown of Other Doors

From kanterella
(Redirected from ML17325B457)
Jump to navigation Jump to search
:on 990107,CR Pressurization Sys Surveillance Test Did Not Test Sys in Normal Operating Condition.Caused by Failure to Recognize Door 12DR-AUX415 as Part of CR Pressure Boundary.Performed Walkdown of Other Doors
ML17325B457
Person / Time
Site: Cook 
Issue date: 02/24/1999
From: Orouke B
AMERICAN ELECTRIC POWER CO., INC.
To:
Shared Package
ML17325B456 List:
References
LER-99-003, LER-99-3, NUDOCS 9903050364
Download: ML17325B457 (5)


LER-1999-003, on 990107,CR Pressurization Sys Surveillance Test Did Not Test Sys in Normal Operating Condition.Caused by Failure to Recognize Door 12DR-AUX415 as Part of CR Pressure Boundary.Performed Walkdown of Other Doors
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(viii)

10 CFR 50.73(a)(2)(i)

10 CFR 50.73(a)(2)(ii)

10 CFR 50.73(a)(2)(iii)

10 CFR 50.73(a)(2)(iv), System Actuation

10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)(vii), Common Cause Inoperability

10 CFR 50.73(a)(2)(x)

10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition
3151999003R00 - NRC Website

text

NRC Form 366 U.S. NUCLEAR REGULATORYCOMMISSION

~

(6-1998)

LICENSEE EVENT REPORT (LER)

(See reverse for required number of digits/characters for each block)

APPROVED 8Y OM8 No. 31504)104 EXPIRES 05/30/2001 ESTSAATED BVRDEN PER

RESPONSE

TO COMPLY WITH TIBS MANDATORY WFORMATIONCOLLECRON REOVEsr. So.o Iors. REPORTED LESSONS LEARNEDARE WCORPORATED INTO THE LICENSING PROCFSS A)e FED BACK TO INCVSTRY.

FORWARD COMMENTS REGARDWG BVRDEN ESTSIATE TO THE WFORMATION AND RECORDS MANAGEMENT BRANCH IT%

FS)).

U.S.

NUCLEAR REGVLATORY COMMISSION. WASHINGTON. DC 205550001. AND TO THE PAPERWORK RFDVCTION PROJECT (5150010l), OFACE OP MANAGEMENT AND BIJOGET. WASISNGTON. DC 205M FACIUTYNAME(1)

TITLE(4)

Cook Nuclear Plant Unit 1 DOCKET NUMBER(2) 05000-315 PAGE (2) 1 of4 Control Room Pressurization System Surveillance Test Does Not Test System In Normal Operating Condition EVENT DATE (5)

LER NUMBER(6)

REPORT DATE (7)

OTHER FACILITIESINVOLVED(8)

MONTH DAY YEAR SEQUENTIAL NUMBER REVISION NUMBER MONTH DAY YEAR A ILI D C Cook Unit 2 U

R 05000-316 01 07 OPERATING MODE (9) 1999 1999 003 00 02 24 1999 A ILI 50.73(a)(2)(viii) 20.2203(a)(2)(v) 20.2201 (b) 50.73(a)(2)(i)

THIS REPORT IS SUBMITTEDPURSUANT TO THE REQUIREMENTS OF 10 CFR Ii: (Check one or more) (11)

POWER LEVEL(10) 0 20.2203(a)(1) 20.2203(a)(2)(i) 20.2203(a)(2)(ii) 20.2203(a)(2)(iii) 20.2203(a)(2)(iv) 20.2203(a)(3)(i) 20.2203(a)(3)(ii) 20.2203(a)(4) 50.36(c)(1) 50.36(c)(2)

LICENSEE CONTACT FOR THIS LER (12) 50.73(a)(2)(ii) 50.73(a)(2)(iii) 50.73(a)(2)(iv) 50.73(a)(2)(v) 50.73(a)(2)(vii) 50.73(a)(2)(x) 73.71 OTHER Specify SI Abstracts below or n NRC Ferro 36EA Ms. Brenda W. O'ourke, Licensing Engineer TELEPHONE NUMBER(Inc4de Area Code)

(616) 465-5901, x2604 COMPLETE ONE LINE FOR EACH COMPONENT FAILURE DESCRIBED IN THIS REPORT (13)

CAUSE

SYSTEM COMPONENT MANUFACTURER REPORTABLE TO EPIX

CAUSE

SYSTEM COMPONENT MANUFACTURER REPORTABLE TO EPIX SUPPLEMENTAL REPORT EXPECTED (14)

X YES (IfYes, complete EXPECTED SUBMISSION DATE)

EXPECTED SUBINISSION DATE (15)

MONTH 07 DAY 30 1999 Abstract {Limitto 1400 spaces, i.e. ~ approximately 15 single-spaced typewritten lines) (16)

On January 7, 1999, Engineering identified that TS surveillance procedure 12 EHP 4030 STP.229, "Control Room Emergency Ventilation Test," did not test the control room pressurization system in normal operating control room pressure boundary configuration. Control room pressure boundary door 12DR-AUX415, which is common to both the Unit 1 and 2 control room pressure boundaries and normally open during plant operation, was closed for performance of the test.

TS 4,7,5.1.e.3 is intended to verify that the pressurization system willmaintain a positive control room pressure during a postulated accident to prevent radioactive material and/or contamination from entering the control room. However, since the test was conducted with door 415 closed, which is not the plant condition expected to exist in the event of a postulated accident, verification of the systems'bility to perform its intended safety function was not accomplished.

Preliminary investigation indicated that failure to recognize door 415 as part of the control room pressure boundary design basis resulted in the door being maintained open since plant start-up. The safety consequences resulting from the door remaining open during a postulated accident could potentially result in control room operator doses in excess of 10 CFR 50 Appendix A, General Design Criteria 19 limits. On January 25, 1999, door 415 was placed in the closed position.

Administrative controls have been established to ensure the door remains closed, except during ingress and egress by plant personnel.

A walkdown of other doors that separate the Unit 1 and 2 control room pressure boundaries was performed which verified that the doors were closed.

The root cause investigation for this event has not been completed.

Additional corrective actions, including preventive actions, may be developed based on the results of the investigation.

Based on the results, supplemental information, including additional corrective and preventive actions, will be provided in an update to this LER by July 30, 1999.

'2)'2)030503b4 990224 PDR ADOCV 0S0003~5 8

PDRU.S. NUCLEAR REGULATORY COMMISSION (6-1998)

LICENSEE EVENT REPORT (LER)

. TEXT.CONTINUATION FACILITYNAME (1)

Cook Nuclear Plant Unit 1 DOCKET NUMBER(2) 05000-315 YEAR 1999 LER NUMBER (6)

SEQUENTIAL NUMBER 003 REVISION NUMBER 00 PAGE (3) 2of4 TEXT (llmore speceis required, use additional copies ofNRC Form (366A) (17)

Conditions Prior to Event

Unit 1 was in Mode 5., Cold Shutdown, depressurized Unit 2 was in Mode 5, Cold Shutdown, depressurized Descri tion of Event On January 7, 1999, Engineering identified that Technical Specification (TS) surveillance procedure 12 EHP 4030 STP.229, "Control Room Emergency Ventilation Test," did not test the control room pressurization system in normal operating control room pressure boundary configuration. An Engineering review determined that control room pressure

~

boundary door 12DR-AUX415, which is common to both the Unit 1 and Unit 2 control rooms and normally in the open position during operation, was closed prior to performance of the TS surveillance test.

In addition, no automatic closure signals exist that would cause the door to close in the event of a control room pressurization system actuation.

Door 12DR-AUX415 is equipped with an electrical release mechanism, which automatically signals the door to close in the event of a fire. Also, a review of current operating procedures identiTied that no instruction exists which would instruct the operators to manually close the door during a postulated accident. A review of the design basis for the control room pressure boundary identified door 12DR-AUX415 as part of the pressure boundary for both Unit 1 and Unit 2 control rooms.

However, a preliminary investigation has concluded that the door had been maintained in the open position since initial plant start-up.

Technical Specification surveillance requirement 4.7.5.1.e.3 is intended to verify that the control room pressurization system willmaintain a positive control room pressure greater than or equal to 1/16 inch water gage relative to the outside atmosphere at a pressurization system flow rate of 6000 cubic feet per minute. However, since the surveillance test was conducted with the control room pressure boundary door closed, which is not the plant condition expected to exist in the event of a postulated accident, verification of the systems'bility to perform its intended safety function was not accomplished.

This condition was previously identified during a self-assessment of the control room and fuel handling area ventilation system conducted in 1991.

Based on the results of the inspection, steps were incorporated into the appropriate Emergency Operating Procedures (EOPs) to ensure that door 12DR-AUX415 would be manually closed when the control room pressurization system was required. A subsequent revision to the EOPs in 1996 inadvertently resulted in these steps being deleted from the procedures.

Cause of Event

Preliminary investigation indicated that failure to recognize door 12DR-AUX415 as part of the control room pressure boundary design basis resulted in the door being maintained open since initial plant start-up, and following identification of this condition in 1991.

Contributing factors included inadequate procedure revision process.

The basis for the changes made to the EOPs, including the justification for the door to remain closed, was not adequately documented in the procedure change sheets.

Also, the appropriate source documents were not referenced in the procedures.

Anal sis of Event This LER is submitted in accordance with 10CFR50.73(a)(2)(i)(B) for a condition prohibited by plant Technical Specifications, since the control room pressurization systems'afety function was not verified as required by TSU.S. NUCLEAR REGULATORY COMMISSION (6-1998)

LICENSEE EVENT REPORT (LER)

TEXT.CONTINUATION FACILITYNAME(1)

Cook Nuclear Plant Unit 1 DOCKET NUMBER(2) 05000-315 YEAR LER NUMBER (6)

SEQUENTIAL NUMBER REVISION NUMBER PAGE (3) 3of4 TEXT (tfmore spece is required, use edditionel copies ofNRC Form (366A) (17)

Analysis of Event (cont.)

1999 003 00 surveillance requirement 4.7.5.1.e.3.

In addition, operation of the plant with door 12DR-AUX415 in the open position resulted in the plant being outside its design basis, which is reportable under 10CFR50.73(a)(2)(ii)(B).

The Unit 1 and Unit 2 control rooms are located adjacent to each other. The control rooms are accessed through common security doors but are divided into separate, independent control room pressure boundaries.

The Unit 1 control room pressure boundary consists of the control room, plant computer room, an equipment room, and kitchen. The Unit 2 control room pressure boundary consists of the control room, plant computer room, an equipment room, and the toilet facilities.

Three doors are common to both pressure boundaries; door 12DR-AUX437, which separates the Unit 1 and Unit 2 equipment rooms, door 12DR-AUX492, which separates the Unit 1 and 2 plant computer rooms, and door 12DR-AUX415, which separates the Unit 1 and 2 control room pressure boundaries.

Each control room has its own independent control room ventilation system.

During normal operating conditions, each control room ventilation system is designed to prevent the entry of dust and dirt into the control room. In the event of a safety injection (Sl) signal or a high radiation signaI, each ventilation system automatically realigns to pressurize its control room to a positive 1/16 inch water gage pressure, with respect to outside atmosphere, to prevent radioactive gases and/or contamination released during a postulated accident from entering the control room pressure boundary.

Preliminary investigation indicated that with both units in Mode 1 through 4, ifa Loss of Coolant Accident (LOCA) occurred in one unit, the Sl signal would initiate the control room ventilation systems in both units. During this operating scenario, both the Unit 1 and Unit 2 control room pressure boundaries would be pressurized.

As a result, the dose consequences of having door 12DR-AUX415 open would be minimal, since the pressurization of either control room would not be compromised.

With a single unit in Mode 1 through 4, and the other unit's control room ventilation system inoperable, the open position of door 12DR-AUX415 could challenge the ability of the ventilation system to maintain a positive control room pressure of 1/16 inch water gage during a LOCA. This condition is also true for events other than a LOCA (e.g., fuel handling accident, waste gas tank rupture) which could occur during any mode of operation.

As a result, radioactive gases and/or contamination released during a postulated event could potentially result in control room operator doses greater than 10 CFR 50 Appendix A, General Design Criteria 19 limits.

At the time this condition was identified, both Unit 1 and Unit 2 were in Mode 5 and neither control room pressurization system had been called upon to perform its safety function. Therefore, no dose consequences existed.

Corrective Actions

As an interim action, on January 25, 1999, door 12DR-AUX415 was placed in the closed position. Administrative controls were established to ensure the door remains in the closed position, except during periods of ingress and egress by plant personnel.

A Control Room Habitability analysis for non-Sl initiating events is currently in progress.

Based on the results of this analysis, it willbe determined ifdoor 12DR-AUX415 must remain closed or if it can be procedurally controlled in the open position.

On February 17, 1999, a walkdown of those doors which serve as pressure boundaries between the Unit 1 and Unit 2 control rooms was performed to verify that the doors were appropriately labeled and in the closed position. Alldoors were found in the closed position. However, doors 12DR-AUX437 and 12DR-AUX492, which are normally closed fire doors, were not labeled as part of the control room pressure boundary.

In addition, it was also identified that door 12DR-436AUX, which is a normally closed fire door and located between the Unit 1 control room and the turbine building, was not labeled as a pressure boundary door. An action request has been initiated to provide permanent labels for these doors.

'NRC FORM 366A (6-1998)U.S. NUCLEAR REGULATORY COMMISSION (6-1998)

LICENSEE EVENT REPORT (LER)

. TEXT.CONTINUATION

'ACILITY NAME(1)

Cook Nuclear Plant Unit 1 DOCKET NUMBER(2) 05000-315 LER NUMBER (6)

SEQUENTIAL NUMBER REVISION NUMBER PAGE (3) 4 of4 TEXT (Ifmore space is required, use additional copies ofNRC Form (366A) (17)

Corrective Actions (cont.)

1999

003 00 As an enhancement to the procedure revision process, PMP 2010.PRC.001, "Procedure Writing," effective February 1, 1999, was developed to provide instruction for revising plant procedures.

The procedure requires that source documents (e.g., commitments, inspection report findings, condition reports) be referenced within the body of the procedure to ensure the source documents used to support changes being made to the procedure are maintained.

An EOP procedure writer's guide is currently being developed which willrequire referencing all source documents used during the revision process and a history of all changes made to the particular EOP.

The appropriate documents willbe revised to include doors 12DR-AUX415, 12DR-AUX437, and 12DR-AUX492 as part of the control room pressure boundary. Also, as part of the EOP upgrade project, a review of past changes made to the procedures, including the bases for the changes willbe completed to ensure the revision history is maintained.

The Updated Final Safety Analysis Report and the Control Room Ventilation System Design Basis Document willbe revised to clearly reflect that the affected doors are part of the control room pressure boundary design basis and to better describe the Unit 1 and Unit 2 control room pressure envelopes.

The root cause investigation for this event has not been completed.

Additional corrective actions, including preventive actions, may be developed based on the results of the root cause investigation.

Also, the control room habitability analysis is currently in progress.

Based on the results of these analyses, additional corrective, including preventive actions may be developed.

It is anticipated that, ifsignificant changes are identified, supplemental information regarding corrective and preventive actions willbe provided in an update to this LER by July 30, 1999.

Previous Similar Events

None.

~C