ML18017A830: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
(2 intermediate revisions by the same user not shown)
Line 3: Line 3:
| issue date = 02/20/1980
| issue date = 02/20/1980
| title = Forwards Final Deficiency Rept Re Lamination in Maint Rail Support Plates
| title = Forwards Final Deficiency Rept Re Lamination in Maint Rail Support Plates
| author name = CHIANGI N J
| author name = Chiangi N
| author affiliation = CAROLINA POWER & LIGHT CO.
| author affiliation = CAROLINA POWER & LIGHT CO.
| addressee name = OREILLY J P
| addressee name = Oreilly J
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
| docket = 05000400, 05000401, 05000402, 05000403
| docket = 05000400, 05000401, 05000402, 05000403
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:I i REGULATORY JORMATION DISTRIBUTION SYS5 (RIDE)ACCESSION NBR;8002260663 DOC~DATE;80/02/20 NOTARlZEO:
{{#Wiki_filter:I i                             REGULATORY JORMATION         DISTRIBUTION SYS5                   (RIDE)
NO P'ACYL:50 400 Shearon Harris Nuclear Power Plantr Onit 1r Carolina 50 401 Shearon Harris Nuclear.Power Plantr Unit 2r Caroline 50 402 Shearon Harris Nuclea~Power Plantr Unit 3r Carolina AUTH'AME AUTHOR AFFIlIATION CHIAAG/rN,J.
ACCESSION NBR;8002260663                 DOC ~ DATE; 80/02/20                 NOTARlZEO: NO           DOCK P'ACYL:50 400 Shearon           Harris Nuclear Power Plantr Onit 1r Carolina                           050 50 401 Shearon       Harris Nuclear. Power Plantr Unit 2r Caroline                         05000401 50 402 Shearon       Harris Nuclea~ Power Plantr Unit 3r Carolina                           05000402 AUTH'AME                   AUTHOR AFFIlIATION CHIAAG/rN,J.                 Caiolina Power 8 Light Co.
Caiolina Power 8 Light Co."RECIP;NAME RECIPIENT AFFILIATION O RE'rl;LV,J.P.
    "RECIP;NAME                   RECIPIENT AFFILIATION O RE'rl;LV,J.P.               Region 4 Atlantean Office of the Director
Region 4 Atlantean Office of the Director  


==SUBJECT:==
==SUBJECT:==
Forwards final deficiency rept re lamination in maint rail suppo,rt plates.DISTRIBUTION CODE: B019S COPIES RECEIVED:LTR 2 ENCL'SIZE: TIl'LEi Construction Deficiency Report (10CFR50.55K)
Forwards final deficiency rept re lamination in maint rail suppo,rt plates.
DOCK 050 05000401 05000402 N r$~~eeasaamoawaseeeowwmmmweemweewmwm~mwwesoeeeom~waetmeo~~eeeeeeemesmmmeewmewmm~w~mreeereweees~m ACTIONS INTFRNAL: REC IP IENT ID CODE/NAME 14 PH foal flf+~20 LA g.~g sIr"H 0 EG FI 05 iaE 08 MPA 10 GAB 12 JORDAN'/IE 16 AD FOR ENGR 17 AD REAC SFTY 23 OElD AEOD GEOSCIENCES BR HATL ENG BA POWER SYS BR STRUCT EAG BR COPIES LTTR ENCL 1 1 1 1 1 1 2 2 i 1 1 1 1 1 1.1 1 1 1 1 1 1 1 1 1 i i RECIPIENT ID CODE/NAME,'5 BC 4 CcJR'g 21 AD Z.u/g 02 NRC PDR 07 EDO 8 STAFF O'Ir DEPY DIA DON 1i STANDRDS DEV 13FIELD COOR'/lE 17 AD PLANT SYS 22 DIR DPN AD/SITE TECH DIRECTOR'SE ISC SYS BR MECH ENG BR S HANAUER COPIES LtTR ENCL.1 1 1 1 i 1 1 1 1 1 i i 1 1 1 i i 1 1 1 1'1 EXTERNAL: 03 LPDR 24 ACRS 1 1 16 04 NSIC 1 1 0~0 e ee TOTAL NUMBER OF COPIES REQUIRED: LTTR 48 ENCl 48 I'ff'~)c I I t f l l 0~yf fl.'.y'g)','1 I I f 4 ff I lf ff I, 4 f~f'f I II I X II FORM R'I~1OOM Carolina Power&Light Company Raleigh, N.C.27602 Pebruazy 20, 1980 Mr.James P.O'Reilly United States Nuclear Regulatory Commission Region II 101 Marietta Street, Northeast Atlanta, Georgia 30303 SHEARON HARRIS NUCLEAR POWER PLANT UNITS 1, 2, 3&4 DOCKET NOSe 50-400, 50-401, 50-402, 50%03 UQiINATION IN MAINTENANCE RAIL SUPPORT PLATES Dear~fr 0 aReilly Attached is the final 10CFR50.55(e) report on the sub]ect deficiency which describes the problem and the correct:ive action taken to accomplish resolution.
DISTRIBUTION CODE: B019S               COPIES RECEIVED:LTR                   2 ENCL'     SIZE:
With this report, Carolina Power 6 Light Company considers this matter closed.If you have any questions regarding this matter, please do not hesitate to contact me.iCVH/bd (156/059)Attachment cc: Hr.V.Stello (2)W/A Tours very truly, Original Signed By N.i.Chiangi N.J.Chiangi-Manager Engineering 6 Construction Quality Assurance j0~}}
TIl'LEi Construction Deficiency Report (10CFR50.55K)
N   r $ ~~ eeasaamoawaseeeowwmmmweemweewmwm~mwwesoeeeom~waetmeo~~eeeeeeemesmmmeewmewmm~w~mreeereweees~m REC IP IENT         COPIES                RECIPIENT                    COPIES ID CODE/NAME           LTTR ENCL          ID                            LtTR ENCL.
flf+~                            BC 4 CcJR'g CODE/NAME,'5 ACTIONS          14 PH foal                 1      1                                          1 20 LA g.~g sIr"H           1     1       21 AD               Z.u/g           1      1 INTFRNAL:        0    EG  FI              1      1      02 NRC PDR                         1 05 iaE                    2      2      07 EDO 8 STAFF                     i 08 MPA                    i              O'Ir DEPY DIA DON                 1        1 10 GAB                    1      1      1i   STANDRDS DEV                 1        1 12 JORDAN'/IE              1      1      13FIELD COOR'/lE                   1 16 AD FOR ENGR            1      1.      17 AD PLANT SYS                   i        i 17 AD REAC SFTY                  1      22 DIR DPN                         1        1 23 OElD                    1              AD/SITE TECH                               1 AEOD                      1      1      DIRECTOR'SE                       i        i GEOSCIENCES BR            1      1      ISC SYS               BR           1       1 1'
HATL ENG BA                1     1       MECH ENG BR                        1 POWER    SYS BR            1     1       S    HANAUER                                1 STRUCT EAG BR              i     i EXTERNAL: 03 LPDR                           1     1       04 NSIC                             1       1 24 ACRS                          16
                                                                                                  ~0 e ee 0
TOTAL NUMBER OF COPIES             REQUIRED: LTTR       48       ENCl           48
 
I
                    'ff
                                              ~)c I     I t
fl l   0 ~   yf               fl .'.y '
g ) ',     '
1 I
I f
4           ff       I lf ff I,                                           4 f'f f~
I II I X II
 
FORM R'I ~ 1OOM Carolina Power & Light Company Raleigh, N. C. 27602 Pebruazy 20, 1980 Mr. James P. O'Reilly United States Nuclear Regulatory Commission Region   II 101 Marietta Street, Northeast Atlanta, Georgia 30303 SHEARON HARRIS NUCLEAR POWER PLANT UNITS 1, 2, 3 & 4 DOCKET NOSe 50-400, 50-401, 50-402, 50%03 UQiINATION IN MAINTENANCE RAIL SUPPORT PLATES Dear ~fr   0 aReilly Attached is the final 10CFR50.55(e) report on the sub]ect deficiency which describes the problem and the correct:ive action taken to accomplish resolution. With this report, Carolina Power 6 Light Company considers this matter closed.
If you have any questions regarding         this matter, please do not hesitate to contact   me.
Tours very truly, Original Signed By N. i. Chiangi N. J. Chiangi - Manager Engineering 6 Construction iCVH/bd (156/059)
Quality Assurance Attachment cc:  Hr. V. Stello (2)  W/A j0~}}

Latest revision as of 19:17, 3 February 2020

Forwards Final Deficiency Rept Re Lamination in Maint Rail Support Plates
ML18017A830
Person / Time
Site: Harris  Duke Energy icon.png
Issue date: 02/20/1980
From: Chiangi N
CAROLINA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18017A831 List:
References
NUDOCS 8002260663
Download: ML18017A830 (3)


Text

I i REGULATORY JORMATION DISTRIBUTION SYS5 (RIDE)

ACCESSION NBR;8002260663 DOC ~ DATE; 80/02/20 NOTARlZEO: NO DOCK P'ACYL:50 400 Shearon Harris Nuclear Power Plantr Onit 1r Carolina 050 50 401 Shearon Harris Nuclear. Power Plantr Unit 2r Caroline 05000401 50 402 Shearon Harris Nuclea~ Power Plantr Unit 3r Carolina 05000402 AUTH'AME AUTHOR AFFIlIATION CHIAAG/rN,J. Caiolina Power 8 Light Co.

"RECIP;NAME RECIPIENT AFFILIATION O RE'rl;LV,J.P. Region 4 Atlantean Office of the Director

SUBJECT:

Forwards final deficiency rept re lamination in maint rail suppo,rt plates.

DISTRIBUTION CODE: B019S COPIES RECEIVED:LTR 2 ENCL' SIZE:

TIl'LEi Construction Deficiency Report (10CFR50.55K)

N r $ ~~ eeasaamoawaseeeowwmmmweemweewmwm~mwwesoeeeom~waetmeo~~eeeeeeemesmmmeewmewmm~w~mreeereweees~m REC IP IENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID LtTR ENCL.

flf+~ BC 4 CcJR'g CODE/NAME,'5 ACTIONS 14 PH foal 1 1 1 20 LA g.~g sIr"H 1 1 21 AD Z.u/g 1 1 INTFRNAL: 0 EG FI 1 1 02 NRC PDR 1 05 iaE 2 2 07 EDO 8 STAFF i 08 MPA i O'Ir DEPY DIA DON 1 1 10 GAB 1 1 1i STANDRDS DEV 1 1 12 JORDAN'/IE 1 1 13FIELD COOR'/lE 1 16 AD FOR ENGR 1 1. 17 AD PLANT SYS i i 17 AD REAC SFTY 1 22 DIR DPN 1 1 23 OElD 1 AD/SITE TECH 1 AEOD 1 1 DIRECTOR'SE i i GEOSCIENCES BR 1 1 ISC SYS BR 1 1 1'

HATL ENG BA 1 1 MECH ENG BR 1 POWER SYS BR 1 1 S HANAUER 1 STRUCT EAG BR i i EXTERNAL: 03 LPDR 1 1 04 NSIC 1 1 24 ACRS 16

~0 e ee 0

TOTAL NUMBER OF COPIES REQUIRED: LTTR 48 ENCl 48

I

'ff

~)c I I t

fl l 0 ~ yf fl .'.y '

g ) ', '

1 I

I f

4 ff I lf ff I, 4 f'f f~

I II I X II

FORM R'I ~ 1OOM Carolina Power & Light Company Raleigh, N. C. 27602 Pebruazy 20, 1980 Mr. James P. O'Reilly United States Nuclear Regulatory Commission Region II 101 Marietta Street, Northeast Atlanta, Georgia 30303 SHEARON HARRIS NUCLEAR POWER PLANT UNITS 1, 2, 3 & 4 DOCKET NOSe 50-400, 50-401, 50-402, 50%03 UQiINATION IN MAINTENANCE RAIL SUPPORT PLATES Dear ~fr 0 aReilly Attached is the final 10CFR50.55(e) report on the sub]ect deficiency which describes the problem and the correct:ive action taken to accomplish resolution. With this report, Carolina Power 6 Light Company considers this matter closed.

If you have any questions regarding this matter, please do not hesitate to contact me.

Tours very truly, Original Signed By N. i. Chiangi N. J. Chiangi - Manager Engineering 6 Construction iCVH/bd (156/059)

Quality Assurance Attachment cc: Hr. V. Stello (2) W/A j0~