ML070030463: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 2: Line 2:
| number = ML070030463
| number = ML070030463
| issue date = 01/16/2007
| issue date = 01/16/2007
| title = Request for Additional Information Regarding Severe Accident Mitigation Alternatives for Susquehanna Steam Electric Station, Units 1 and 2 (TAC Nos. MD3021 and MD3022)
| title = Request for Additional Information Regarding Severe Accident Mitigation Alternatives for Susquehanna Steam Electric Station, Units 1 and 2
| author name = Mullins A
| author name = Mullins A
| author affiliation = NRC/NRR/ADRO/DLR/REBB
| author affiliation = NRC/NRR/ADRO/DLR/REBB
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:January 16, 2007Mr. Britt T. MckinneySr. Vice President & Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Boulevard Berwick, PA 18603-0467
{{#Wiki_filter:January 16, 2007 Mr. Britt T. Mckinney Sr. Vice President & Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Boulevard Berwick, PA 18603-0467


==SUBJECT:==
==SUBJECT:==
REQUESTS FOR ADDITIONAL INFORMATION REGARDING SEVEREACCIDENT MITIGATION ALTERNATIVES FOR SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 (TAC NOS. MD3021 AND MD3022)
REQUESTS FOR ADDITIONAL INFORMATION REGARDING SEVERE ACCIDENT MITIGATION ALTERNATIVES FOR SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 (TAC NOS. MD3021 AND MD3022)


==Dear Mr. McKinney:==
==Dear Mr. McKinney:==


The U.S. Nuclear Regulatory Commission staff has reviewed the Severe Accident MitigationAlternatives analysis submitted by PPL Susquehanna, LLC, in support of its application for license renewal for the Susquehanna Steam Electric Station, and has identified areas where additional information is needed to complete its review. Enclosed are the staff's requests for additional information.We request that you provide your responses to these questions within 90 days of the date ofthis letter to support the license renewal review schedule. If you have any questions, please contact me at 301-415-1224 or via email at axm7@nrc.gov
The U.S. Nuclear Regulatory Commission staff has reviewed the Severe Accident Mitigation Alternatives analysis submitted by PPL Susquehanna, LLC, in support of its application for license renewal for the Susquehanna Steam Electric Station, and has identified areas where additional information is needed to complete its review. Enclosed are the staffs requests for additional information.
.Sincerely, /RA/Alicia Mullins, Project ManagerEnvironmental Branch B Division of License Renewal Office of Nuclear Reactor RegulationDocket Nos. 50-387 and 50-388
We request that you provide your responses to these questions within 90 days of the date of this letter to support the license renewal review schedule. If you have any questions, please contact me at 301-415-1224 or via email at axm7@nrc.gov.
Sincerely,
                                      /RA/
Alicia Mullins, Project Manager Environmental Branch B Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-387 and 50-388


==Enclosure:==
==Enclosure:==
As statedcc w/encl: See next page January 16, 2007Mr. Britt T. MckinneySr. Vice President & Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Boulevard Berwick, PA 18603-0467
 
As stated cc w/encl: See next page
 
January 16, 2007 Mr. Britt T. Mckinney Sr. Vice President & Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Boulevard Berwick, PA 18603-0467


==SUBJECT:==
==SUBJECT:==
REQUESTS FOR ADDITIONAL INFORMATION REGARDING SEVEREACCIDENT MITIGATION ALTERNATIVES FOR SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 (TAC NOS. MD3021 AND MD3022)
REQUESTS FOR ADDITIONAL INFORMATION REGARDING SEVERE ACCIDENT MITIGATION ALTERNATIVES FOR SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 (TAC NOS. MD3021 AND MD3022)


==Dear Mr. McKinney:==
==Dear Mr. McKinney:==


The U.S. Nuclear Regulatory Commission staff has reviewed the Severe Accident MitigationAlternatives analysis submitted by PPL Susquehanna, LLC, in support of its application for license renewal for the Susquehanna Steam Electric Station, and has identified areas where additional information is needed to complete its review. Enclosed are the staff's requests for additional information.We request that you provide your responses to these questions within 90 days of the date ofthis letter to support the license renewal review schedule. If you have any questions, please contact me at 301-415-1224 or via email at axm7@nrc.gov
The U.S. Nuclear Regulatory Commission staff has reviewed the Severe Accident Mitigation Alternatives analysis submitted by PPL Susquehanna, LLC, in support of its application for license renewal for the Susquehanna Steam Electric Station, and has identified areas where additional information is needed to complete its review. Enclosed are the staffs requests for additional information.
.Sincerely, /RA/Alicia Mullins, Project ManagerEnvironmental Branch B Division of License Renewal Office of Nuclear Reactor RegulationDocket Nos. 50-387 and 50-388
We request that you provide your responses to these questions within 90 days of the date of this letter to support the license renewal review schedule. If you have any questions, please contact me at 301-415-1224 or via email at axm7@nrc.gov.
Sincerely,
                                      /RA/
Alicia Mullins, Project Manager Environmental Branch B Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-387 and 50-388


==Enclosure:==
==Enclosure:==
As statedcc w/encl:  See next page DISTRIBUTION: See next page


Adams Accession No. ML070030463OFFICELA:DLRPM:DLR:REBBPM:DLR:REBBBC:DLR:REBBNAMEI. KingJ.DavisA.MullinsR.Franovich DATE01/5/07 01/8/0701/16/0701/16/07 OFFICIAL RECORD COPY Letter to B. McKinney from A. Mullins Dated January 16, 2007
As stated cc w/encl: See next page DISTRIBUTION: See next page Adams Accession No. ML070030463 OFFICE            LA:DLR            PM:DLR:REBB              PM:DLR:REBB          BC:DLR:REBB NAME              I. King              J.Davis                  A.Mullins          R.Franovich DATE            01/5/07               01/8/07                  01/16/07            01/16/07 OFFICIAL RECORD COPY
 
Letter to B. McKinney from A. Mullins Dated January 16, 2007


==SUBJECT:==
==SUBJECT:==
REQUEST FOR ADDITIONAL INFORMATION REGARDING SEVERE ACCIDENTMITIGATION ALTERNATIVES FOR SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 (TAC NOS. MD3021 AND MD3022)DISTRIBUTION
REQUEST FOR ADDITIONAL INFORMATION REGARDING SEVERE ACCIDENT MITIGATION ALTERNATIVES FOR SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 (TAC NOS. MD3021 AND MD3022)
:HARD COPYA. MullinsB. Palla E-MAILP.T. Kuo (RidsNrrDlr)M. Rubin (RidsNrrDraApla)
DISTRIBUTION:
HARD COPY A. Mullins B. Palla E-MAIL P.T. Kuo (RidsNrrDlr)
M. Rubin (RidsNrrDraApla)
R. Franovich (RidsNrrDlrRebb)
R. Franovich (RidsNrrDlrRebb)
E. Benner (RidsNrrDlrReba)
E. Benner (RidsNrrDlrReba)
B. Palla PMNS BRidsNrrAdro RidsNrrDlrRebb RidsNrrDlrReba RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsOgcMailRoom RidsOpaMail RidsOcaMailCenter A. Mullins J. Davis S. Lopas R. Schaaf F. Monette (fmonette@anl.gov)
B. Palla PMNS BRidsNrrAdro RidsNrrDlrRebb RidsNrrDlrReba RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsOgcMailRoom RidsOpaMail RidsOcaMailCenter A. Mullins J. Davis S. Lopas R. Schaaf F. Monette (fmonette@anl.gov)
R. Guzman Y. Diaz Sanabria E. Gettys A. Blamey, SRI Region 1 N. Sheehan, OPA Region 1 Samuel Lee, EDO Contact, Region I A. Blamey (ajb3@nrc.gov)
R. Guzman Y. Diaz Sanabria E. Gettys A. Blamey, SRI Region 1 N. Sheehan, OPA Region 1 Samuel Lee, EDO Contact, Region I A. Blamey (ajb3@nrc.gov)
C. Colleli R. K. Wild
C. Colleli R. K. Wild J. Storch
 
Request for Additional Information Regarding the Analysis of Severe Accident Mitigation Alternatives for the Susquehanna Steam Electric Station, Units 1 and 2
: 1. Provide the following information regarding the Susquehanna Steam Electric Station (SSES)
Probabilistic Risk Assessment (PRA) model used for the Severe Accident Mitigation Alternatives (SAMA) analysis:
: a. Provide a summary of the major Level 1 and 2 PRA versions and their core damage frequency (CDFs) from the Individual Plant Examination (IPE) to the present, including the version reviewed by the Boiling Water Reactor Owners Group (BWROG), and the version used for risk-informed submittals such as inservice inspection and allowed outage time extension for offsite power. Also, indicate the major changes to each version from the prior version (including the changes from pre-Extended Power Uprate (EPU) to post-EPU models) and the major reasons for changes in the CDF.
: b. Provide the freeze date for the incorporation of design and/or procedure changes into the PRA.
: c. Provide the CDF contribution due to station blackout (SBO) and anticipated transient without scram (ATWS).
: d. Explain why loss of an AC bus is a very small (approximately 0.2 percent) contributor to the CDF.
: e. The summary of the BWROG peer review overall assessment provided on pages E.2-14 and -15 describes a non-conservatism associated with SBO events. Identify the facts and observations (F&Os) associated with this non-conservatism and discuss their resolution.
: f. Section E.2.3.2 of the Environmental Report (ER) describes a self assessment that considered the open Level B F&Os and concluded that the remaining items and gaps would not have a significant impact on the EPU application. Confirm that the same conclusion can be drawn concerning the impacts of the remaining items and gaps on the SAMA analysis.
: g. Describe the current containment venting capability and procedural directions at SSES (hard pipe, via standby gas treatment system, etc.) and how it is modeled in the PRA.
: 2. Provide the following information relative to the Level 2 analysis:
: a. Provide a summary description of the current Level 2 model, including: the Level 1/Level 2 interface, the containment event tree (CET), the basis for quantification of CET nodes, the binning process used to assign end states to release categories, and the determination of release fractions for each release category.
ENCLOSURE
: b.      Describe the steps taken to ensure the technical adequacy of the Level 2 revisions subsequent to the BWROG peer review.
: 3. Provide the following information with regard to the treatment and inclusion of external events in the SAMA analysis:
: a.      The individual plant examination of external events (IPEEE) fire analysis utilized the IPE internal events models to assess system performance. Indicate whether the original IPE models or the revised IPE models were utilized.
: b.      Based on a sensitivity study performed by PPL Susquehanna, LLC, the U.S. Nuclear Regulatory Commission concluded in the IPEEE safety evaluation report that the CDF for some fire contributors might be as much as three orders of magnitude higher than the revised values reported in the IPEEE. Discuss this issue and its potential impact on the ER assumption that the fire CDF is about equal to the internal events CDF.
: 4. Provide the following information concerning the MACCS2 analyses:
: a.      Clarify whether separate ORIGEN calculations were performed for pre-EPU and post-EPU conditions and used to determine population doses for the respective cases.
: b.      Based on the March 31, 2006, license amendment request, the EPU power level would be approximately 13% above the current licensed power level. As such, the population dose for EPU conditions would be expected to be approximately 13% greater than for pre-EPU conditions. However, from Table E.3-4, the increase in dose for the dominant release categories (e.g., L2-1, L2-2, and L2-5) ranges from 4 to 11%. Explain this result.
: 5. Provide the following with regard to the SAMA identification and screening process:
: a.      Tables E.5-1 and E.5-2 include a number of events that are described as preventative maintenance actions (i.e., 024-N-E-DSL-P, 024-I-A-DSL-P, and 024-II-B-DSL-P). Identify the specific structure, system, and components associated with these maintenance actions.
: b.      Section 5.1.5 includes a list of nine enhancements identified in the IPE. The seventh enhancement, revise guidance regarding reactor vessel control, is listed as not implemented and only provides the reasoning that the enhancement has been determined not to be required for safe operation of the plant. Provide a further description of the disposition of this enhancement, and any efforts made to identify SAMA candidates exist to address the associated risk contributors.
: c.      Section E.5.1.7.1 discusses the contribution to fire CDF from the dominant fire zones.
Although two SAMAs from the internal events analysis were identified to address this risk, no SAMAs unique to the fire analysis were identified. For each fire zone, discuss the potential for SAMAs to address the unique cause of the fire risk, such as SAMAs to reduce the fire initiators, to improve fire detection or suppression, or to relocate components or cabling.
: 6. Provide the following with regard to the Phase 2 cost-benefit evaluations:
: a.      For SAMA 3, Proceduralize Reactor Pressure Valve Depressurization When Fire Protection System Injection is the Only Makeup Source, indicate what failure events were included for the failure to provide late low pressure injection via the fire main.
: b.      For SAMA 8, Automatic Feedwater Runback for ATWS, the percent reduction in dose risk and offsite economic cost risk (OECR) is much smaller than the reduction in CDF.
The reduction in CDF is almost entirely in the low/early release category, which has a very small contribution to dose-risk and OECR. One might expect the reduction in CDF due to ATWS to impact high or medium release categories. Explain this apparent discrepancy.
: c.      In the discussion of the costs for SAMA 8, it is implied that the cost estimate does not account for inflation. Clarify whether this cost estimate, or any other cost estimates, accounts for inflation.
: d.      For SAMA 12, Containment Venting After Core Damage, the analysis shows very little risk reduction. Since this SAMA would reduce the releases for all drywell overpressure failure sequences, a more significant reduction in risk would be expected. Explain the reasons for the small risk reduction for this SAMA.
: 7. One of the Mark I plants considered in its SAMA identification process (Section E.5.1.4) identified the following SAMAs as potentially cost-beneficial:
: a.      Develop guidance/procedures for local, manual control of reactor core isolation cooling following loss of DC power.
: b.      Procedures to control containment venting to avoid adverse impacts on emergency core cooling system.
These SAMAs would appear to be applicable to SSES but are not among the Phase 2 SAMAs for SSES. Provide a brief statement regarding the applicability/feasibility of these alternatives for SSES, and a further evaluation (similar to those evaluations provided in the ER) if the alternative could be potentially cost-beneficial at SSES.


J. Storch Request for Additional InformationRegarding the Analysis of Severe Accident Mitigation Alternativesfor the Susquehanna Steam Electric Station, Units 1 and 21.Provide the following information regarding the Susquehanna Steam Electric Station (SSES)Probabilistic Risk Assessment (PRA) model used for the Severe Accident Mitigation Alternatives (SAMA) analysis:a.Provide a summary of the major Level 1 and 2 PRA versions and their core damagefrequency (CDFs) from the Individual Plant Examination (IPE) to the present, including the version reviewed by the Boiling Water Reactor Owners Group (BWROG), and the version used for risk-informed submittals such as inservice inspection and allowed outage time extension for offsite power. Also, indicate the major changes to each version from the prior version (including the changes from pre-Extended Power Uprate (EPU) to post-EPU models) and the major reasons for changes in the CDF.b.Provide the freeze date for the incorporation of design and/or procedure changes intothe PRA.c.Provide the CDF contribution due to station blackout (SBO) and anticipatedtransient without scram (ATWS).d.Explain why loss of an AC bus is a very small (approximately 0.2 percent)contributor to the CDF.e.The summary of the BWROG peer review overall assessment provided on pagesE.2-14 and -15 describes a non-conservatism associated with SBO events. Identify the facts and observations (F&Os) associated with this non-conservatism and discuss their resolution.f.Section E.2.3.2 of the Environmental Report (ER) describes a self assessment thatconsidered the open Level B F&Os and concluded that the remaining items and gaps would not have a significant impact on the EPU application. Confirm that the same conclusion can be drawn concerning the impacts of the remaining items and gaps on the SAMA analysis.g.Describe the current containment venting capability and procedural directions at SSES(hard pipe, via standby gas treatment system, etc.) and how it is modeled in the PRA.2.Provide the following information relative to the Level 2 analysis:a.Provide a summary description of the current Level 2 model, including:  the Level1/Level 2 interface, the containment event tree (CET), the basis for quantification of CET nodes, the binning process used to assign end states to release categories, and the determination of release fractions for each release category.ENCLOSURE  b.Describe the steps taken to ensure the technical adequacy of the Level 2 revisionssubsequent to the BWROG peer review.3.Provide the following information with regard to the treatment and inclusion of external eventsin the SAMA analysis:a.The individual plant examination of external events (IPEEE) fire analysis utilized the IPEinternal events models to assess system performance. Indicate whether the original IPE models or the revised IPE models were utilized.b.Based on a sensitivity study performed by PPL Susquehanna, LLC, the U.S. NuclearRegulatory Commission concluded in the IPEEE safety evaluation report that the CDF for some fire contributors might be as much as three orders of magnitude higher than the revised values reported in the IPEEE. Discuss this issue and its potential impact on the ER assumption that the fire CDF is about equal to the internal events CDF.4.Provide the following information concerning the MACCS2 analyses:a.Clarify whether separate ORIGEN calculations were performed for pre-EPU andpost-EPU conditions and used to determine population doses for the respective cases.b.Based on the March 31, 2006, license amendment request, the EPU power level wouldbe approximately 13% above the current licensed power level. As such, the population dose for EPU conditions would be expected to be approximately 13% greater than for pre-EPU conditions. However, from Table E.3-4, the increase in dose for the dominant release categories (e.g., L2-1, L2-2, and L2-5) ranges from 4 to 11%. Explain this result. 5.Provide the following with regard to the SAMA identification and screening process:a.Tables E.5-1 and E.5-2 include a number of events that are described aspreventative maintenance actions (i.e., 024-N-E-DSL-P, 024-I-A-DSL-P, and 024-II-B-DSL-P). Identify the specific structure, system, and components associated with these maintenance actions.b.Section 5.1.5 includes a list of nine enhancements identified in the IPE. The seventhenhancement, revise guidance regarding reactor vessel control, is listed as "not implemented" and only provides the reasoning that the enhancement has been determined not to be required for safe operation of the plant. Provide a further description of the disposition of this enhancement, and any efforts made to identify SAMA candidates exist to address the associated risk contributors.c.Section E.5.1.7.1 discusses the contribution to fire CDF from the dominant fire zones. Although two SAMAs from the internal events analysis were identified to address this risk, no SAMAs unique to the fire analysis were identified. For each fire zone, discuss the potential for SAMAs to address the unique cause of the fire risk, such as SAMAs to reduce the fire initiators, to improve fire detection or suppression, or to relocate components or cabling. 6.Provide the following with regard to the Phase 2 cost-benefit evaluations:a.For SAMA 3, Proceduralize Reactor Pressure Valve Depressurization When FireProtection System Injection is the Only Makeup Source, indicate what failure events were included for the failure to provide late low pressure injection via the fire main.b.For SAMA 8, Automatic Feedwater Runback for ATWS, the percent reduction in doserisk and offsite economic cost risk (OECR) is much smaller than the reduction in CDF.
Susquehanna Steam Electric Station, Unit Nos. 1 and 2 cc:
The reduction in CDF is almost entirely in the low/early release category, which has a very small contribution to dose-risk and OECR. One might expect the reduction in CDF due to ATWS to impact high or medium release categories. Explain this apparent discrepancy.c.In the discussion of the costs for SAMA 8, it is implied that the cost estimate does notaccount for inflation. Clarify whether this cost estimate, or any other cost estimates, accounts for inflation.d.For SAMA 12, Containment Venting After Core Damage, the analysis shows very littlerisk reduction. Since this SAMA would reduce the releases for all drywell overpressure failure sequences, a more significant reduction in risk would be expected. Explain the reasons for the small risk reduction for this SAMA.7.One of the Mark I plants considered in it's SAMA identification process (Section E.5.1.4)identified the following SAMAs as potentially cost-beneficial:a.Develop guidance/procedures for local, manual control of reactor core isolation coolingfollowing loss of DC power.b.Procedures to control containment venting to avoid adverse impacts on emergencycore cooling system.These SAMAs would appear to be applicable to SSES but are not among the Phase 2 SAMAsfor SSES. Provide a brief statement regarding the applicability/feasibility of these alternatives for SSES, and a further evaluation (similar to those evaluations provided in the ER) if the alternative could be potentially cost-beneficial at SSES.
Robert A. Saccone                                   Luis A. Ramos Vice President - Nuclear Operations                 Community Relations Manager, PPL Susquehanna, LLC                               Susquehanna 769 Salem Blvd., NUCSB3                             PPL Susquehanna, LLC Berwick, PA 18603-0467                              634 Salem Blvd., SSO Berwick, PA 18603-0467 Aloysius J. Wrape, III General Manager - Performance                       Bryan A. Snapp, Esq.
Susquehanna Steam Electric Station, Unit Nos. 1 and 2 cc:Robert A. Saccone Vice President - Nuclear Operations PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467Aloysius J. Wrape, IIIGeneral Manager - Performance Improvement and Oversight PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179Terry L. HarpsterGeneral Manager - Plant Support PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467Rocco R. SgarroManager - Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179Walter E. MorrisseySupervising Engineer Nuclear Regulatory Affairs PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467Michael H. CrowthersSupervising Engineer Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179Steven M. CookManager - Quality Assurance PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 Berwick, PA  18603-0467Luis A. RamosCommunity Relations Manager, Susquehanna PPL Susquehanna, LLC 634 Salem Blvd., SSO Berwick, PA 18603-0467Bryan A. Snapp, Esq.Associate General Counsel PPL Services Corporation Two North Ninth Street, GENTW3 Allentown, PA  18101-1179Supervisor - Document Control ServicesPPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA  18101-1179Richard W. OsborneAllegheny Electric Cooperative, Inc.
Improvement and Oversight                         Associate General Counsel PPL Susquehanna, LLC                               PPL Services Corporation Two North Ninth Street, GENPL4                     Two North Ninth Street, GENTW3 Allentown, PA 18101-1179                            Allentown, PA 18101-1179 Terry L. Harpster                                  Supervisor - Document Control Services General Manager - Plant Support                     PPL Susquehanna, LLC PPL Susquehanna, LLC                                Two North Ninth Street, GENPL4 769 Salem Blvd., NUCSA4                             Allentown, PA 18101-1179 Berwick, PA 18603-0467 Richard W. Osborne Rocco R. Sgarro                                    Allegheny Electric Cooperative, Inc.
212 Locust Street P.O. Box 1266 Harrisburg, PA 17108-1266Director, Bureau of Radiation ProtectionPennsylvania Department of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA  17105-8469Senior Resident InspectorU.S. Nuclear Regulatory Commission P.O. Box 35, NUCSA4Berwick, PA  18603-0035Regional Administrator, Region 1U.S. Nuclear Regulatory Commission
Manager - Nuclear Regulatory Affairs               212 Locust Street PPL Susquehanna, LLC                               P.O. Box 1266 Two North Ninth Street, GENPL4                     Harrisburg, PA 17108-1266 Allentown, PA 18101-1179 Director, Bureau of Radiation Protection Walter E. Morrissey                                Pennsylvania Department of Supervising Engineer                                 Environmental Protection Nuclear Regulatory Affairs                         Rachel Carson State Office Building PPL Susquehanna, LLC                               P.O. Box 8469 769 Salem Blvd., NUCSA4                             Harrisburg, PA 17105-8469 Berwick, PA 18603-0467 Senior Resident Inspector Michael H. Crowthers                                U.S. Nuclear Regulatory Commission Supervising Engineer                               P.O. Box 35, NUCSA4 Nuclear Regulatory Affairs                         Berwick, PA 18603-0035 PPL Susquehanna, LLC Two North Ninth Street, GENPL4                     Regional Administrator, Region 1 Allentown, PA 18101-1179                            U.S. Nuclear Regulatory Commission 475 Allendale Road Steven M. Cook                                      King of Prussia, PA 19406 Manager - Quality Assurance PPL Susquehanna, LLC                               Board of Supervisors 769 Salem Blvd., NUCSB2                             Salem Township Berwick, PA 18603-0467                              P.O. Box 405 Berwick, PA 18603-0035


475 Allendale Road King of Prussia, PA  19406Board of SupervisorsSalem Township P.O. Box 405 Berwick, PA  18603-0035 Susquehanna Steam Electric Station, Unit Nos. 1 and 2 cc:-2-Dr. Judith JohnsrudNational Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803Mr. James RossNuclear Energy Institute 1776 I Street, N.W., Suite 400 Washington, D.C. 20006-3708}}
Susquehanna Steam Electric Station, Unit Nos. 1 and 2 cc:
Dr. Judith Johnsrud National Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803 Mr. James Ross Nuclear Energy Institute 1776 I Street, N.W., Suite 400 Washington, D.C. 20006-3708
                                              }}

Latest revision as of 23:17, 22 March 2020

Request for Additional Information Regarding Severe Accident Mitigation Alternatives for Susquehanna Steam Electric Station, Units 1 and 2
ML070030463
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 01/16/2007
From: Alicia Mullins
NRC/NRR/ADRO/DLR/REBB
To: Mckinney B
Susquehanna
Mullins A, NRR/DLR, 415-1224
References
TAC MD3021, TAC MD3022
Download: ML070030463 (8)


Text

January 16, 2007 Mr. Britt T. Mckinney Sr. Vice President & Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Boulevard Berwick, PA 18603-0467

SUBJECT:

REQUESTS FOR ADDITIONAL INFORMATION REGARDING SEVERE ACCIDENT MITIGATION ALTERNATIVES FOR SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 (TAC NOS. MD3021 AND MD3022)

Dear Mr. McKinney:

The U.S. Nuclear Regulatory Commission staff has reviewed the Severe Accident Mitigation Alternatives analysis submitted by PPL Susquehanna, LLC, in support of its application for license renewal for the Susquehanna Steam Electric Station, and has identified areas where additional information is needed to complete its review. Enclosed are the staffs requests for additional information.

We request that you provide your responses to these questions within 90 days of the date of this letter to support the license renewal review schedule. If you have any questions, please contact me at 301-415-1224 or via email at axm7@nrc.gov.

Sincerely,

/RA/

Alicia Mullins, Project Manager Environmental Branch B Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-387 and 50-388

Enclosure:

As stated cc w/encl: See next page

January 16, 2007 Mr. Britt T. Mckinney Sr. Vice President & Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Boulevard Berwick, PA 18603-0467

SUBJECT:

REQUESTS FOR ADDITIONAL INFORMATION REGARDING SEVERE ACCIDENT MITIGATION ALTERNATIVES FOR SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 (TAC NOS. MD3021 AND MD3022)

Dear Mr. McKinney:

The U.S. Nuclear Regulatory Commission staff has reviewed the Severe Accident Mitigation Alternatives analysis submitted by PPL Susquehanna, LLC, in support of its application for license renewal for the Susquehanna Steam Electric Station, and has identified areas where additional information is needed to complete its review. Enclosed are the staffs requests for additional information.

We request that you provide your responses to these questions within 90 days of the date of this letter to support the license renewal review schedule. If you have any questions, please contact me at 301-415-1224 or via email at axm7@nrc.gov.

Sincerely,

/RA/

Alicia Mullins, Project Manager Environmental Branch B Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-387 and 50-388

Enclosure:

As stated cc w/encl: See next page DISTRIBUTION: See next page Adams Accession No. ML070030463 OFFICE LA:DLR PM:DLR:REBB PM:DLR:REBB BC:DLR:REBB NAME I. King J.Davis A.Mullins R.Franovich DATE 01/5/07 01/8/07 01/16/07 01/16/07 OFFICIAL RECORD COPY

Letter to B. McKinney from A. Mullins Dated January 16, 2007

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION REGARDING SEVERE ACCIDENT MITIGATION ALTERNATIVES FOR SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 (TAC NOS. MD3021 AND MD3022)

DISTRIBUTION:

HARD COPY A. Mullins B. Palla E-MAIL P.T. Kuo (RidsNrrDlr)

M. Rubin (RidsNrrDraApla)

R. Franovich (RidsNrrDlrRebb)

E. Benner (RidsNrrDlrReba)

B. Palla PMNS BRidsNrrAdro RidsNrrDlrRebb RidsNrrDlrReba RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsOgcMailRoom RidsOpaMail RidsOcaMailCenter A. Mullins J. Davis S. Lopas R. Schaaf F. Monette (fmonette@anl.gov)

R. Guzman Y. Diaz Sanabria E. Gettys A. Blamey, SRI Region 1 N. Sheehan, OPA Region 1 Samuel Lee, EDO Contact, Region I A. Blamey (ajb3@nrc.gov)

C. Colleli R. K. Wild J. Storch

Request for Additional Information Regarding the Analysis of Severe Accident Mitigation Alternatives for the Susquehanna Steam Electric Station, Units 1 and 2

1. Provide the following information regarding the Susquehanna Steam Electric Station (SSES)

Probabilistic Risk Assessment (PRA) model used for the Severe Accident Mitigation Alternatives (SAMA) analysis:

a. Provide a summary of the major Level 1 and 2 PRA versions and their core damage frequency (CDFs) from the Individual Plant Examination (IPE) to the present, including the version reviewed by the Boiling Water Reactor Owners Group (BWROG), and the version used for risk-informed submittals such as inservice inspection and allowed outage time extension for offsite power. Also, indicate the major changes to each version from the prior version (including the changes from pre-Extended Power Uprate (EPU) to post-EPU models) and the major reasons for changes in the CDF.
b. Provide the freeze date for the incorporation of design and/or procedure changes into the PRA.
c. Provide the CDF contribution due to station blackout (SBO) and anticipated transient without scram (ATWS).
d. Explain why loss of an AC bus is a very small (approximately 0.2 percent) contributor to the CDF.
e. The summary of the BWROG peer review overall assessment provided on pages E.2-14 and -15 describes a non-conservatism associated with SBO events. Identify the facts and observations (F&Os) associated with this non-conservatism and discuss their resolution.
f. Section E.2.3.2 of the Environmental Report (ER) describes a self assessment that considered the open Level B F&Os and concluded that the remaining items and gaps would not have a significant impact on the EPU application. Confirm that the same conclusion can be drawn concerning the impacts of the remaining items and gaps on the SAMA analysis.
g. Describe the current containment venting capability and procedural directions at SSES (hard pipe, via standby gas treatment system, etc.) and how it is modeled in the PRA.
2. Provide the following information relative to the Level 2 analysis:
a. Provide a summary description of the current Level 2 model, including: the Level 1/Level 2 interface, the containment event tree (CET), the basis for quantification of CET nodes, the binning process used to assign end states to release categories, and the determination of release fractions for each release category.

ENCLOSURE

b. Describe the steps taken to ensure the technical adequacy of the Level 2 revisions subsequent to the BWROG peer review.
3. Provide the following information with regard to the treatment and inclusion of external events in the SAMA analysis:
a. The individual plant examination of external events (IPEEE) fire analysis utilized the IPE internal events models to assess system performance. Indicate whether the original IPE models or the revised IPE models were utilized.
b. Based on a sensitivity study performed by PPL Susquehanna, LLC, the U.S. Nuclear Regulatory Commission concluded in the IPEEE safety evaluation report that the CDF for some fire contributors might be as much as three orders of magnitude higher than the revised values reported in the IPEEE. Discuss this issue and its potential impact on the ER assumption that the fire CDF is about equal to the internal events CDF.
4. Provide the following information concerning the MACCS2 analyses:
a. Clarify whether separate ORIGEN calculations were performed for pre-EPU and post-EPU conditions and used to determine population doses for the respective cases.
b. Based on the March 31, 2006, license amendment request, the EPU power level would be approximately 13% above the current licensed power level. As such, the population dose for EPU conditions would be expected to be approximately 13% greater than for pre-EPU conditions. However, from Table E.3-4, the increase in dose for the dominant release categories (e.g., L2-1, L2-2, and L2-5) ranges from 4 to 11%. Explain this result.
5. Provide the following with regard to the SAMA identification and screening process:
a. Tables E.5-1 and E.5-2 include a number of events that are described as preventative maintenance actions (i.e., 024-N-E-DSL-P, 024-I-A-DSL-P, and 024-II-B-DSL-P). Identify the specific structure, system, and components associated with these maintenance actions.
b. Section 5.1.5 includes a list of nine enhancements identified in the IPE. The seventh enhancement, revise guidance regarding reactor vessel control, is listed as not implemented and only provides the reasoning that the enhancement has been determined not to be required for safe operation of the plant. Provide a further description of the disposition of this enhancement, and any efforts made to identify SAMA candidates exist to address the associated risk contributors.
c. Section E.5.1.7.1 discusses the contribution to fire CDF from the dominant fire zones.

Although two SAMAs from the internal events analysis were identified to address this risk, no SAMAs unique to the fire analysis were identified. For each fire zone, discuss the potential for SAMAs to address the unique cause of the fire risk, such as SAMAs to reduce the fire initiators, to improve fire detection or suppression, or to relocate components or cabling.

6. Provide the following with regard to the Phase 2 cost-benefit evaluations:
a. For SAMA 3, Proceduralize Reactor Pressure Valve Depressurization When Fire Protection System Injection is the Only Makeup Source, indicate what failure events were included for the failure to provide late low pressure injection via the fire main.
b. For SAMA 8, Automatic Feedwater Runback for ATWS, the percent reduction in dose risk and offsite economic cost risk (OECR) is much smaller than the reduction in CDF.

The reduction in CDF is almost entirely in the low/early release category, which has a very small contribution to dose-risk and OECR. One might expect the reduction in CDF due to ATWS to impact high or medium release categories. Explain this apparent discrepancy.

c. In the discussion of the costs for SAMA 8, it is implied that the cost estimate does not account for inflation. Clarify whether this cost estimate, or any other cost estimates, accounts for inflation.
d. For SAMA 12, Containment Venting After Core Damage, the analysis shows very little risk reduction. Since this SAMA would reduce the releases for all drywell overpressure failure sequences, a more significant reduction in risk would be expected. Explain the reasons for the small risk reduction for this SAMA.
7. One of the Mark I plants considered in its SAMA identification process (Section E.5.1.4) identified the following SAMAs as potentially cost-beneficial:
a. Develop guidance/procedures for local, manual control of reactor core isolation cooling following loss of DC power.
b. Procedures to control containment venting to avoid adverse impacts on emergency core cooling system.

These SAMAs would appear to be applicable to SSES but are not among the Phase 2 SAMAs for SSES. Provide a brief statement regarding the applicability/feasibility of these alternatives for SSES, and a further evaluation (similar to those evaluations provided in the ER) if the alternative could be potentially cost-beneficial at SSES.

Susquehanna Steam Electric Station, Unit Nos. 1 and 2 cc:

Robert A. Saccone Luis A. Ramos Vice President - Nuclear Operations Community Relations Manager, PPL Susquehanna, LLC Susquehanna 769 Salem Blvd., NUCSB3 PPL Susquehanna, LLC Berwick, PA 18603-0467 634 Salem Blvd., SSO Berwick, PA 18603-0467 Aloysius J. Wrape, III General Manager - Performance Bryan A. Snapp, Esq.

Improvement and Oversight Associate General Counsel PPL Susquehanna, LLC PPL Services Corporation Two North Ninth Street, GENPL4 Two North Ninth Street, GENTW3 Allentown, PA 18101-1179 Allentown, PA 18101-1179 Terry L. Harpster Supervisor - Document Control Services General Manager - Plant Support PPL Susquehanna, LLC PPL Susquehanna, LLC Two North Ninth Street, GENPL4 769 Salem Blvd., NUCSA4 Allentown, PA 18101-1179 Berwick, PA 18603-0467 Richard W. Osborne Rocco R. Sgarro Allegheny Electric Cooperative, Inc.

Manager - Nuclear Regulatory Affairs 212 Locust Street PPL Susquehanna, LLC P.O. Box 1266 Two North Ninth Street, GENPL4 Harrisburg, PA 17108-1266 Allentown, PA 18101-1179 Director, Bureau of Radiation Protection Walter E. Morrissey Pennsylvania Department of Supervising Engineer Environmental Protection Nuclear Regulatory Affairs Rachel Carson State Office Building PPL Susquehanna, LLC P.O. Box 8469 769 Salem Blvd., NUCSA4 Harrisburg, PA 17105-8469 Berwick, PA 18603-0467 Senior Resident Inspector Michael H. Crowthers U.S. Nuclear Regulatory Commission Supervising Engineer P.O. Box 35, NUCSA4 Nuclear Regulatory Affairs Berwick, PA 18603-0035 PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Regional Administrator, Region 1 Allentown, PA 18101-1179 U.S. Nuclear Regulatory Commission 475 Allendale Road Steven M. Cook King of Prussia, PA 19406 Manager - Quality Assurance PPL Susquehanna, LLC Board of Supervisors 769 Salem Blvd., NUCSB2 Salem Township Berwick, PA 18603-0467 P.O. Box 405 Berwick, PA 18603-0035

Susquehanna Steam Electric Station, Unit Nos. 1 and 2 cc:

Dr. Judith Johnsrud National Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803 Mr. James Ross Nuclear Energy Institute 1776 I Street, N.W., Suite 400 Washington, D.C. 20006-3708