Monette, Frederick A.

From:

LaGory, Kirk E.

Sent:

Monday, October 09, 2006 2:49 PM To:

Monette, Frederick A.

Subject:

RE: SSES ER Acceptance Review Fred:

Your letter looks good, but I would specifically mention the lack of information on streams and wetlands on the site. It is kind of covered on your second to last bullet but I would prefer greater specificity. Other than that, the ER looks acceptable.

Kirk Kirk E. LaGory, Ph.D.

Ecologist Environmental Science Division Argonne National Laboratory Building 900 9700 S. Cass Avenue Argonne, Illinois 60439 Phone: 630-252-3169 Mobile: 630-564-3169 Fax: 630-252-6090 Email: lagory@anl.gov From: Monette, Frederick A.

Sent: Monday,.October 09, 2006 2:39 PM To: Avci, Halil I.; LaGory, Kirk E.

Subject:

SSES ER Acceptance Review Hi Halil and Kirk, Attached is a draft of the ER acceptance review results that I am going to send Alicia, either at the end of today or tomorrow morning. I thought I'd run it by you before sending it.

Fred

<< File: SSES ER Acceptance Review.doc >>

Fred Monette Environmental Science Division Bld. 900 Argonne National Laboratory Argonne, IL 60439 Ph:

630-252-5722 Cell:

630-991-3253 Fax:

630-252-4624 I