TXX-4546, Forwards Rev 1 to Westinghouse Proprietary & Nonproprietary Responses to Questions Re Improved Thermal Design Procedures & Application for Withholding Proprietary Response. Proprietary Responses Withheld (Ref 10CFR2.790)

From kanterella
(Redirected from TXX-4546)
Jump to navigation Jump to search
Forwards Rev 1 to Westinghouse Proprietary & Nonproprietary Responses to Questions Re Improved Thermal Design Procedures & Application for Withholding Proprietary Response. Proprietary Responses Withheld (Ref 10CFR2.790)
ML20135C262
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 09/05/1985
From: Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Noonan V
Office of Nuclear Reactor Regulation
Shared Package
ML19269B670 List:
References
TXX-4546, NUDOCS 8509110372
Download: ML20135C262 (2)


Text

-

Log # TXX-4546 TEXAS UTILITIES GENERATING COMPANY File # 10010 MRYW AY TOWER e 400 NORTH Ot.JWR STRt.hT. I 95. se t e DAELAN. TIG Am 7830 6 September 5, 1985 0h? 0&N."Ah Director of Nuclear Reactor Regulation Attention: Mr. Vince S. Noonan, Director Comanche Peak Project Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C. 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STAT.ON (CPSES)

DOCKET NOS. 50-445 AND 50-446 APPLICATION FOR WITHHOLDlhG PROPRIETARY INFORMATION FROM PUBLIC DISCLOSURE

Dear Mr. Noonan:

Enclosed are:

1. Ten (10) copies of Westinghouse responses to questions on improved Thernal Design Procedures (Proprietary).
2. Ten (10) copies of Westir.ghouse responses to questions on Improved Tnermal Design Procedures (Non-Proprietary).

Also enclosed are:

1. One (1) copy of Westinghouse approval letter CAW-85-057 (Non-Proprietary).
2. One (1) copy of the Proprietary information hotice.
3. One (1) copy of Affidavit (Non-Proprietary).

In addition to providing responses to questions concerning Westingnouse Improved Tnermal Design Procedures, which have ocen used only for Coinancne Peak Unit 2, the attached responses provide justification for a reduced flow meter measurement uncertainty value. This value and justification are applicaole to both Comanche Peak Units 1 and 2.

This submittal contains proprietary information of Westinghouse Electric Corporation. In conformance with the requirements of 10 CFR Section 2./90, as amended, of the Commission's regulations, we are enclosing with this submittal an application for withholding from public disclosure by the Commission. The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Comnission. l 0509110372 050905 32 'e MV ,jg //oF PDR ADOCK 050 5 8 p%, ggg g, gp tot.

Art ML , M t. o A nosvonson or trnAn motsturn ess:n sure suserAny

Correspondence with respect to the affidavit or application for withholding should reference CAW-85-057 and should be addressed to R. A. Wiesemann, Manager, Regulatory and Legislative Affairs, Westinghouse Electric Corporation, P. O. Box 355, Pittsburgh, PA 15230.

Very truly yours, h

f 41<bl W. G. Counsil RWH/grr Enclosure c- S. B. Burwell s