Text

_ _ - - - _

l{.-u- -

m Edwin l. Hatch Nuclear Plant Georgia Power the SOJrre'r ee:.11 c wer' Novmber 7,1978 PM-78-411 FIANT E. I. HLTUI Reactor Contaiment Building IIRP (Unit 1) e Director: U.S. Nuclear Reactor Regulations k c/o Distribution Services Branch DDC, AIM U.S. Nuclear Regulatory Cmmission Washington, D.C. 20555

Dear Gentlemen:

Please find the enclosed report describing the 1978 Type A test successfully performed April 11, 1978 on the E. I. Hatch Unit 1 Primwy Containment.

Mr. Floyd Cantrell (NRC I & E Principle Inspector) was notified on August 16, 1978 concerning the late submittal of the report.

jjf u -d. Manry //

I- Plant Manager WRG/bw xc: H. C. Nix ,

Floyd Cantrell (w/ enclosure '3 copies) ,

File M58 n

L-9'

\ , 'a d - *

,e l

6 ampsn r...yjEEtte n.stA- t 0

\uy l

4W s 7 812 2 6 0 /Sy.t P '

/

l

.- -. . ._ - . .. - _ -