PM-78-411, Forwards Reactor Containment Bldg Integrated Leak Rate Test for Subj Facil
| ML20062G027 | |
| Person / Time | |
|---|---|
| Site: | Hatch |
| Issue date: | 11/07/1978 |
| From: | Manry M GEORGIA POWER CO. |
| To: | NRC OFFICE OF ADMINISTRATION (ADM) |
| Shared Package | |
| ML20062G030 | List: |
| References | |
| PM-78-411, NUDOCS 7812260154 | |
| Download: ML20062G027 (1) | |
Text
_ _ - - - _
l{.-u-m Georgia Power Edwin l. Hatch Nuclear Plant the SOJrre'r ee:.11 c wer' Novmber 7,1978 PM-78-411 FIANT E. I. HLTUI Reactor Contaiment Building IIRP (Unit 1)
Director: U.S. Nuclear Reactor Regulations ek c/o Distribution Services Branch DDC, AIM U.S. Nuclear Regulatory Cmmission Washington, D.C.
20555
Dear Gentlemen:
Please find the enclosed report describing the 1978 Type A test successfully performed April 11, 1978 on the E. I. Hatch Unit 1 Primwy Containment.
Mr. Floyd Cantrell (NRC I & E Principle Inspector) was notified on August 16, 1978 concerning the late submittal of the report.
jjf I-u -d. Manry //
Plant Manager WRG/bw xc:
H. C. Nix Floyd Cantrell (w/ enclosure
'3 copies)
File M58 n
L-9'
\\, 'a d -
6 amps r...yjEEtte n.stA-t
,e n
l
\\u y
0 l
4W s
7 812 2 6 0 /Sy.t P
/
l
.-