August 26, 1998 Mr. Leon J. Olivtr c l
Vice President - Nuclear / Station Director Boston Edison Company.
Pilgrim Nuclear Power Station
- RFD #.1 Rocky Hill Road
' Plymouth, MA' 02360
Dear Mr. Olivier:
SUBJECT:
' SUPPLEMENT AND REVISIONS TO SAFETY EVALUATION FOR AMENDMENT NO.173, PILGRIM NUCLEAR POWER STATION l
Dear Mr. Olivier:
' By letter dated December 30,' 1997 Boston Edison Company (BECo/licen'see) provided j
clarifications and corrections to the Safsp Evaluation (SE) associated with' Amendment No.173
[.
dated' July 3,1997. We have reviewed these comments and revised the SE to address BECo's comments. We did not address all of your comments as several of them were clarifications for which the sa3 felt the original SE was sufficient. The changes, in general, clarified or corrected statements in the SE..The changes did not modify or change any of our conclusions'with
~
regards to the Amendment. Therefore, the staff concludes that the proposed statements do not invalidate the following conclusions reached in the staff's safety evaluation of July 3,1997: (1) there h: reasonable assurance that the hea;th and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the
. Commission's regulations, Land (3) the issuance of this amendment will not be inimical to the common defense and security nor the health and safety of the public. Enclosed is the.
supplemental SE supporting the changes for the revised SE for Amendment No.173 and the revised pages.
- Any questions regarding this revision should be sent to my attention at the above address; or, I
you can contact me at (301) 415-1445.
Sincerely, Original signed by
' Alan B. Wang, Project Manager Project Directorate 1-3 Division of Reactor Projects - 1/II Office of Nuclear Reactor Regulation Docket No. 50-293
Enclosure:
- 1. -Supplemental Safety Evaluation
' 2. Revised SE Pages ccw/ encl: See next page -
t DISTRIBUTION-Docket File.
T. Clark
~J. Zwolinski ACRS PUBLIC -
A. Wang
..C. Cowgill, Rl KKavanaugh PDl-3 R/F OGC-
.J. Knox T. Harris (TLH3)
RLaura, SRI
lE Pet:PDI 3-l
())D PDI b
- 3 M.,q I
l l IIAfE TLCLark LAi
- AWeng
\\WN' M s/
4 fYVI(ff L. U l
4 DATE 06/1A /96 08/ W /98 66/T./98
.N/ f $98 l
OFFICIAL RECORD COPY 13 E PJ ii E m i W d,,
~
9908310040 990826 PDR ADOCK 05000293
- J P
?
c Mr. Leon J. Olivier Boston Edison Company Pilgrim Nuclear Power Station ec:
Mr. Ron Ledgett Mr. Jack Alexander Executive Vice President Manager, Reg. Relations and Quality 800 Boyleston Street Assurance Boston, MA 02199 Pilgrim Nuclear Power Station RFD #1 Rocky Hill Road Resident inspector-Plymouth, MA 02360 U. S. Nuclear Regulatory Commission Pilgrim Nuclear Power Station Mr. David F. Tarantino Post Office Box 867 Nuclear Information Manager Plymouth, MA 02360 Pilgrim Nuclear Power Station RFD #1, Rocky Hill Road Chairman, Board of Selectmen Plymouth, MA 02360 11 Lincoln Street Plymouth, MA 02360 Ms. Kathleen M. O'Toole Secretary of Public Safety Chairman, Duxbury Board of Selectmen Executive Office of Public Safety Town Hall One Ashburton Place 878 Trer. ont Street Boston, MA 02108 Duxbury, WlA 02332 l
Mr. Peter LaPorte, Director Office of the Commissioner Attn: James Muckerheide l
Massachusetts Department of Massachusetts Emergency Management I
Environmental Protection Agency
{
One Winter Street 400 Worcester Road i
Boston, MA 02108 P.O. Box 1496 Framingham, MA 01701-0317 Office of the Attomey General One Ashburton Place Chairman, Citizens Urging 20th Floor Responsible Energy Boston, MA 02108 P.O. Box 2621 Duxbury, MA 02331 Mr. Robert M. Hallisey, Director Radiation Control Program Citizens at Risk Massachusetts Department of P.O. Box 3803 Public Health Plymouth, MA 02361 305 South Street Boston, MA 02130 W.S. Stowe, Esquire Boston Edison Company Regional Administrator, Region i 800 Boyleston St.,36th Floor U. S. Nuclear Regulatory Commission Boston, MA 02199 475 Allendale Road King of Prussia, PA 19406 Chairman Nuclear Matteis Committee Ms. Jane Fleming Town Hall 8 Oceanwood Drive 11 Lincoln Street Duxbury, MA 0233 Plymouth, MA 02360 Mr. James Keyes Mr. William D. Meinert Acting Licensing Division Manager Nuclear Engineer Boston Edison Company Massachusetts Municipal Wholesale 600 Rocky Hiil Road Electric Company l
Plymouth, MA 02360-5599 P.O. Box 426 Ludlow, MA 01056-0426 i
-