RBG-24508, Suppls 860514 Response to Item a of IE Bulletin 85-003.BWR Owners Group Efforts to Develop Generic Position for Meeting Item a Documented in 860902 Submittal.Completion of Items b-d Anticipated by 871115

From kanterella
(Redirected from ML20215F466)
Jump to navigation Jump to search
Suppls 860514 Response to Item a of IE Bulletin 85-003.BWR Owners Group Efforts to Develop Generic Position for Meeting Item a Documented in 860902 Submittal.Completion of Items b-d Anticipated by 871115
ML20215F466
Person / Time
Site: River Bend Entergy icon.png
Issue date: 10/02/1986
From: Booker J
GULF STATES UTILITIES CO.
To: Martin R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
IEB-85-003, IEB-85-3, RBG-24508, NUDOCS 8610160223
Download: ML20215F466 (5)


Text

  • b GULF STATES UTILITIES COMPANY P O S T O F F I C E B O X 2 9 51 .8EAUMONT, TEXAS 77704 AREACODE 409 838-6631 October 2, 1986 RBG- 24508 File No(s) G9.5, G9.33.1 Mr. Robert D. Martin, Regional Administrator 3 @@

U. S. Nuclear Regulatory Commission Region IV

] (\[/ h '

611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 E-8@ l

Dear Mr. Martin:

L ' O River Bend Station - Unit 1 Docket No. 50-458 NRC I&E Bulletin 85-03 In a letter dated May 14, 1986 (RBG-23678) Gulf States Utilities Company (GSU) provided a preliminary response to item (a) of NRC I&E Bulletin 85-03 (IEB 85-03). As indicated in that letter, GSU requested an extension in order to utilize the BWR Owners' Group (BWROG) efforts in developing a generic position for meeting item (a) of IEB 85-03. The BWROG efforts have been completed and submitted to the NRC on September 2, 1986 (BWROG-8645, T.A. Pickens/BWROG to J.M. Talyor/NRC).

Attached please find GSU's completed response to item (a) of IEB 85-03. As provided in the May letter the program to complete items (b) through (d) is scheduled to be completed by November 15, 1987. The report required by item (f) will be provided within 60 days of completion of the program as required by IEB 83-03. Should this schedule change significantly GSU will advise the NRC.

Should you have any questions feel free to contact us.

Sincerely, e Mr

/.J. E. Booker Manager-River Bend Oversight cc: NRC Document Control Desk

\

8610160223 861002 j ADOCK 05000458 PDR G PDR (

-h{

-l57

~

. r Page 1 of 3 ATTACHMENT TO,RBG- 24S08 Item (a)

As noted in the cover letter, the BWROG (of which GSU is a member) recently completed a generic position (NEDC-31322) for meeting item (a) of IEB 85-03. In the BWROG report,_the systems that are considered to be within the scope of IEB 85-03, (as applicable to River Bend Station) are the High Pressure Core Spray (HPCST System and the Reactor Core Isolation Cooling (RCIC) System. GSU hes utilized the BWROG report where applicable and has completed a final review of the HPCS System and

'RCIC System to identify the motor-operated valves (MOVs) and maximum differential pressures expected that are within the scope of IEB.85-03.

The following is a list of each MOV and maximum differential pressure expected identified as a result of this review:

(1) (2) (3) (4) (5) (6)

Opening Closing Differential Differential Pressure Pressure System Valve Tag Size (in) Tyge (PSID) (PSID)

HPCS E22*F001 16 CATE (a) 131 HPCS E22*F004 10 GATE 1423 1486 HPCS E22*F010 10 GLOBE (a) 1431 HPCS E22*F011 10 GLOBE (a) 1431 HPCS E22*F012 4 GATE 1446 1608 HPCS E22*F015 20 GATE 94 17 HPCS E22*F023 10 GLOBE (a) 1430 RCIC E51*C002 4 GLOBE (b) (b)

RCIC E51*F010 6 GATE (a) 71 RCIC E51*F013 6 GATE 1371 1546 RCIC E51*F019 2 GLOBE 1455 1469 RCIC E51*F022 4 GLOBE (a) 1430 RCIC E51*F031 6 GATE 19 17 RCIC E51*F045 4 GLOBE 1165 1165 RCIC E51*F046 2 GLOBE 1386 (a)

RCIC E51*F059 4 GATE (a) 1430 RCIC E51*F063 8 GATE (a) 1165 RCIC E51*F064 8 GATE (a) 1165 RCIC E51*F068 12 GATE (a) 8 RCIC E51*F076 .75 GLOBE (a) 1165 RCIC E51*F077 1.5 GLOBE (a) 23 RCIC E51*F078 2.5 GLOBE (a) 23 4

Page 2 of 3 NOTES (a) Based on the BWROG report (NEDC-31322), values are not provided when no active safety function (i.e., valve opening or closing) is required.

(b) Valve E51*C002 functions as the RCIC turbine trip and throttle valve. The function and active safety action of the RCIC turbine trip _and throttle valve is to trip closed when required to protect the turbine and pump. The motor operator on this valve is only used to reset the valve to the open position following a turbine trip. Because this valve is included in the River Bend ASME Section XI Surveillance Test Program, it has been included in this report for completeness.

Wete: The pressures provided in the table above, which are based on worse case scenarios, are conservative and may be reduced through more detailed analysis.

l

! l l

I 9

4 I ' ' '

Page 3 of 3 Heading Explanations (1) System in which a valve is located.

HPCS'- High Pressure Core Spray RCIC - Reactor Core Isolation Cooling

-(2) Valve Tag is a unique identifying number for each valve. The asterisk (*) in the number indicates a safety related (QA Category I) valve. l 1

(3) Size is the valve size in inches-as specified in the Design Specification Data Sheet (DSDS) for that Valve Tag No.

(4). Type is either gate or globe as specified on the DSDS.

'(5) Opening Differential Pressure is the maximum pressure differential expected to occur across a valve when the valve is required to

-open under worst case conditions.

(6) Closing Differential Pressure is the maximum pressure differential expected to occur across a valve when the valve is required to close under worst case conditions.

l 4

4

a . . o.

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION-STATE OF LOUISIANA- 5 i

PARISH OF WEST FELICIANA 5 5

In the Matter of 5- Docket ~No. 50-458 5

GULF STATES UTILITIES COMPANY 5 5

(River Bend Station 5 Unit 1) 5 AFFIDAVIT J. E. Booker, being duly sworn, states that he is Manager-River Bend' Oversight for Gulf States Utilities Company; that he is authorized on the

. part of said Company to sign and file with the Nuclear Regulatory

- Commission the documents attached hereto; that he has read all of the statements contained in such documents attached thereto and made a part thereof; and that all such statements made-and matters set forth therein are true and correct to the best of his knowledge, information and belief.

d . F. L & -