Rev 2 to Procedure QI-QP-11.0-15, Verification of Base Plates for Grouting
ML20137J067
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 09/20/1983
From: Warner M
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
Shared Package
ML17198A292 List: ... further results
References
FOIA-85-59 QI-QP-11.0-15, NUDOCS 8512020540
Download: ML20137J067 (5)


Text

.

(

INSTRUCTCN ISSUE TEXAS UTILITIES GENERATING CO.

NUMBER t

DATE PAOI REVISION CPSES l

i

!QI-QP-11.0-15 :

2 1 of 5 l

SEP 2 01953 i

I l

{ PREPARED BY: # -

- -p 7-e*C-d 3 VERIFICATION OF

~

C/ ~;

OUT APPROVED BY: I'k W

9

!f I

/Qf '

'[>

APPROVED BY:

/,.

1

/[ j DATE I

1.0 REFERENCES

I l-A Gibbs and Hill Specification 2323-55-9, " Concrete" 1-B CP-QP-18.0, " Inspection Reports" 1-C CEI-25, " Grouting Pi pe Support Wall and Ceiling Plates" g

l 1-D QI-QP-11.0-6, "pnggipn of Grouting" t

ra.

1-E CP-QP-15.0, "T[gging Sy(temi :,.

l i

%W &

l*..,

-,- pa l

2.0 PURPOSE AND SCOPE L

~-

g.g The purpoce of this instruction is to provide the cMteria to be-used when performing verification of seismic wall and ceiling mounted component support base plates located in j

Seismic Category I Buildings for grouting in accordance with the requi rements of Reference 1-A.

Floor mounted base plates receiving dry pack material or grout do not fa M

i within the scope of this instruction.

1.

3.0 INSTRUCTION l

1 3.1 BASE PLATE GROUTING AND SHIMMING i

Component support base plates mounted to concrete surfaces I

shall not exceed a 1/16" gap between the base plate and concrete for a minimum of 80% of the base plate area. The gap between the base plate and concrete for a maximum of 20". may exceed 1/16" but at no point shall the gap exceed 1/2".

The gap shall be measured from the periphery of the l

baseplate (See Attachment 1).

l Shim material may consist of steel shim plates or washers of a size necessary to allow proper Hilti bolt torquing without base plate deformation.

The grout fill holes shall be 1/4" diamater and shall not be drilled within 1 inch of a O

concrete anchor.

Additionally, the grout fill holes shall C) be located outside the bolt hole pattern, i

~

' coa eM2020S40 BM FOIA ppa PDR GARDEBS-59

(

INSTRUCTION ISSUE REVISION PAGE NUMBER DATE TEXAS UTILITIES GENERATING CO.

I

(

SES QI-QP-11.0-15 2

2 of 5 SEP 2 0 1993 j

i i

l i

NOTE:

Floor mounted component supports that are not l

flush mounted requi re shimming and grouting and i

shall be verified by Quality Control inspectors per Reference 1-0, 3.2 DOCUMENTATION j

Inspections shall be recorded on an Inspection Report in i

accordance with Reference 1-B.

This Inspection Report may be included as attributes on an Inspection Report generic to a specific hanger inspection instruction (i.e., Class 5 pi pe suppo rts, condui t supports) as outli ned in that i

specific instruction.

l Hangers inspected by the craft as required per Reference 1-C do not require a Bearing Inspection Report (Attachment 2) written for grout placement purposes.

I All unsatisfactory conditions shall be documented on an IR and/or a NCR per Reference 1-B.

IR's shall be processed O

as directed by the QA/QC Supervisor.

A reject tag may be applied to "unsat" items per Reference 1-E.

During Room Turnover activities, QC inspectors may complete I'

a "walkdown" of base plates to veri fy adequate support bearing and document on Attachment 3.

?

l V&

Pennsee.1 MMM

...J

~

L-

(

1 4

! INSTRUCTION REVtSICN ISSUE

! TEXAS UTILmES GENERATING CO. l PAGE CPSES

{SEP 2 0 1983 QI-qP-11.0-15, 2

3 of 5 r

ATTACHMENT 1 EXAMPLE: BASE PLATE 10" x 10"

\\

h

%n

%v n.

w' M

s K e xxxxxxxxxxxxx%

l 2

i Base Plate 100 inches i

807, 1/16" gap I

Cross-hatched area may be up to 5" gap as long as

~

t total area does not exceed 20 sq. inches.

D!

TUGCC CA

.. ~ - -

~,

--_n,

.. -. ~... -,, - -,,,,,,,.. - -, - -

(;

INSTRUCTION ISSUE r

REVISION PAGE O.

NUMBER DATE I TEXAS UTluTIES GENERATING CO.

l CPSES l

01-0P-il.0-15 2

SEP 2 0 1983 4g s I

ATTACHMENT 2

cw.nco,e atu s Esu issc~asc sizzcu
s. m

-r INSPECTION REPORT an ITEM CasGJtipT.CM

]GL% rmT.64 30 3T57EM / ITNuGTym [ MEhaT:GN r

?.

4 sas:..sc.

. ac..

2 323-SS-9

,I g v e.c coc. a arv. a enames so.

a msamma Gn rm couin..oc T. mo.

se 01 0p.11.0 15 Rev.

a CI"asE!b'c*m CPagfyrTa Ogitpet

&,g'yerio, C P*t&,

rroa ma p. ensui. s b iNSPEC*fCN COMPLETEo, AL&. aP86;Ca4LE ITEMS saftsFaCTCAT C insatCnon comutto, unsariwactont iTtmo usito.estow oc ins y ;rcA art

'C INSPECTION ATTRIBUTES ca?t a,

1.

I Gac does not exceed 4" at any coint betwea-ha'episte I

I l

1. d es,,e

+.,,,<.,..

o...

, 1.

I I

I i

l l i 1

2.

!Gao coes not exceed 1/16" for 80% or more of baseplate l' l l l

l bearino surface Pan. 3.1.

l i I l

4 l

l Il l

L i(Mas iastalled.

Dan. 1.1 l

l I

I I

Ii i

l l l l

I I i l i

I I

l l

i i

t i f I

s i i l

i I l l

t i ! i l

I I I i i

l i I i i

i l i l I

l l Ii l

l I

e ii f

I l l i l

nemaans (chras, sacs,tTeJ 1

"4 3 l 1.R. CLOSC ME n

i isieh m e i

=

8 i

oc wtSPt:*C4 g

N aman mm

  • ~. *

.-,.-w*---

i 7

i i

I i

l 1 INSTRUCTION I l

ISSUE

{ USD DATE PAGE TEXAS UTILITIES GENERATING CO. j NUMBER CPSES SEP 2 0 1983 OI-QP-ll.0-15 2

1 5 of 5 i

ATTACHMENT 3

MmNCNE AEAK STEAM E6E;7hc STAOCN W

M g'

f lNSPECT10N REPORT le

.rtm ot.cmiet.o=

czarmc41.c=

  • purgw e sr=wcmat xs.c. arc.

e 1.

M 3PWM e nEV W R OOC. 4 agv e gnan(.E go setasunt gm rg5T gswap.ccigT,gg.

sl s!

Of-OP-11.0-15 Rev s

t l

Oi,,;;g>A avs;;3sr=- aegg-gg a r:so, O P"f;&,

i asp. nean.ts I

C asn: rom ::erres au. escasu irtus sansn: rent O sm:no= co-ario. w eariseacto v irs = unrio sc.o=

.c g,g,",y,g INSPECTION ATTRIOUTES a;

3 cart 5

3

=

2

.i l

ll I

l 1.

ISEISMIC SUPPORTS IN ABOVE REFERENCED AREA SATISFY lI!

I IBEARING REQUIREMENTS PER PARAGDAPW 3.1.

I !i I

I II I

3 i

i l

ll I

i li I

I ii i

{

l I

Ii l

l II e

i li I

l I I I

i

'l I

l l-1i li i

iI j

I I

'I I

I i ! i i

f I

l i li l

l i

i l l l t

i I

IlI i

I i i l i

I i l l I

a=

is. m es.e m 1

(

    • All inspectors performing room verification to sign this IR.