Ack Receipt of 850326 Request for Action Under 10CFR2.206 for Order to Show Cause Why OL Should Not Be Suspended or Revoked Due to Qualification of Const & Operations QA Personnel
ML20127D917
Person / Time
Site: Callaway Ameren icon.png
Issue date: 05/10/1985
From: Taylor J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To: Nemes A
AFFILIATION NOT ASSIGNED
References
2.206, NUDOCS 8505170105
Download: ML20127D917 (4)


Text

f f

g.3 Ctco d f,, LIN1TED STATES E, (; g NUCLEAR REGULATORY COMMISSION 5 g,, g /Mj WASHINGTON. D. C. 20555 gg@'v f/a MAY l 01985..

Docket No. 50-483 (10 CFR 2.206)

Alan S. Nemes, Esq.

7541 Parkdale St. Louis, M0 63105

Dear Mr. Nemes:

This letter acknowledges receipt of the request for action under 10 CFR 2.206 dated March 25, 1985, which you submitted on behalf of the Missouri Coalition for the Environment and Kay Drey. The petition requested that an order be issued to the Union Electric Company to_show cause why the operating license for the Callaway Plant should not be suspended or revoked pending an investi-gation of the issues described in your petition. Those issues pertain to the qualification of construction and operattons quality assurance personnel. As stated in 10 CFR 2.206, appropriate action will be taken on your request witnin a reasonable time.

Enclosed for your information is a copy of the notice which will be sent to the Office of the Federal Register for publication.

Sincerely,

/

. Tay r, Director

. ,. ffice of spection and Enforcement

Enclosure:

Federal fegister Notice cc w/ enclosure:

Union Electric Company Thomas Baxter, Esq.,

Shaw, Pittman, Potts, and Trowbridge 8505170105 850510 PDR ADOCK 05000483 p PDR W. - - _ _ _

?

[7590-01]

UNITED STATES NUCLEAR REGULATORY COMMISSION

[DocketNo.50-483]

UNION ELECTRIC COMPANY (Callaway Plant, Unit 1)

RECEIPT OF REQUEST FOR ACTION UNDER 10 CFR 2.206 Notice is hereby~given that by Petition dated March 25, 1985, Alan S. Nemes, Esq., on behalf of Kay Drey and the Missouri Coalition for the Environment, requesting that an order be issued to the Union Electric Company to show cause why the operating license for the Callaway Plant should not be suspended or revoked pending an investigation of the issues described in the Petition, and why the other actions requested therein should not be taken. The issues raised in the petition pertain primarily to the qualification of construction and operations quality assurance personnel. The petition is being handled pursuant to 10 CFR 2.206 and accordingly, appropriace action will be taken on the Petition within a reasonable time.

Copies of the Petition are available for public inspection in the

mmission's Co public document room at 1717 H Street, N.W., Washington, DC, 20555 and in the local public docum ; for the Callaway Plant, located at the

, John M. Olin Library, Washingtun University, Skinker and Lindell Boulevards, St. Louis, M0, 63130.

Dated at Bethesda, Maryland, this day of May, 1985.

FOR THE NUCLEAR REGULATORY COMMISSION i

James M. Taylor, Director Office of Inspection and Enforcement

.. e Alan S. Nemes- Distribution:

-SECY OGC 60CS3' ED0 PDR LPDR.

G. H -Cunningham, ELD E. S. Christenbury, ELD J. Lieberman, ELD L.'N.-Cuoco, ELD J. G. Keppler, RIII B. A. Berson, RIII H.' R. Denton, NRR T. W. Alexion, NRR J. M. Taylor, IE J. A. Axelrad, IE.

B. K. Grimes, IE

.G.'T. Ankrum, IE W. D. Altman, IE

.M.-Malloy, IE L. J. Toms, IE QAB Reading DQAVT Reading (EDO #000523)

IE Action 85-165 b

g-QAB l a'//r' w %

B IE:DQAVT: IE T:QAB:C I: VT:D ELD MMalloy: c WDAltman GTAn mes JLeiberman 05/;L/85' 05/&-/85 05 05/,r/85 05/}/85 I . S- IE: IE:

J rad: R 1mer JMic o:

/ 5 03/ /85 05/6v85 6)[4k 4r L

(*

Alan S. Nemes Distribution:

SECY OGC DCS ED0 PDR LPDR G. H. Cunningham, ELO E. S. Christenbury, ELD J. Lieberman, ELD L. N. Cuoco, ELD J. G. Keppler, RIII B. A. Berson, RIII H. R. Denton, NRR T. W. Alexion, NRR J. M. Taylor, IE J. A. Axelrad, IE B. K. Grimes, IE G. T.'Ankrum, IE W. D. Altman, IE ,

M. Malloy, IE L. J. Toms, IE QAB Reading DQAVT Reading (EDO #000523)

IE Action 85-165 W

/

f& D E:D A AB IE:D B IE:MVT:QAB:C I. VT:D E MMalloy: c WDAltman GTAn m mes JLeiberman 05/4t/85 05/b/85 05 5 05/ } /85 05/,t/85 I . S- I- IE: l J rad R .

1mer JMTa lo

/ 5 05/ /85 05/(f '85

%{4%

C