F R AM ATOM E TECHNOLOGlES hkee 50-M3 Integrated Nuclear Services September 15,1999 Mr. Jack N Donohew Senior Project Manager, Section 2 Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation United States Nuclear Regulatory Cornmistion Washington, D.C. 20555-0001

Subject:

Review of Technical Letter Report for Proprietary Information

References:

1.

Letter to Robert Schomaker from Jack N. Donohew, June 30, 1999. Request for Review of Technical Letter Report for Proprietary information (TAC NO. MA3954), (From Dwight R.

Diercks) Dated July 1,1999.

2. Public Meeting on Research Related to the Integrity Of Degraded Steam Generator Tubes and Electrosleeve-Repaired Tubes Under Severe Accident Conditions, Held at Argonne National Laboratory,9700 South Cass Avenue, Argonne Illinois, July 15, 1999
3. Letter to James Galford from Dwight R. Diercks, (A corrected version of Saurin Majumdar's July 15,1999 handout), July 28, 1999.

I

4. Docket No. 50-483 Dear Mr. Donohew l

This letter is a formal documentation of the reviews and discussions identified in O

Reference 1. The review of Reference 1 was discussed in telephone conference calls and documented via e-mail messages. The following is a summary of the telephone call conversations as documented on July 8,'1999.

With the intent to make the technical information contained in Reference 1 g

available for public reference in the most useful form, FTl held a conference P

call with J. Muscara and Dwight R. Diercks on July 7,1999.

9910100021 990915 PDR ADOCK 05000483~

P PDR 1#

166 Mill Hloge Road, Lynchburg, VA 24502-4341 Telephone: 804 832-3700 Fax: 804 832-0622

,t' Mr.-Jack Donohew Page 2 of 3 Review of Technical Letter Report for Proprietary information 9/15/99 l

FTl requested a general change of " repair" or " repaired" tube description to simply state the reference sample. The dimensions used should either be l

noted as nominal or reference in several places a reference to test data l

' reported by Westmoreland Laboratories was noted.

It was suggested that this reference be changed to "FTl Low temperature"

' or "FTl high temperature" data as determined to be appropriate. With these p

minor comments, the report may be denoted as Non-Proprietary or may in fact not have any notation as Non-Proprietary, which inould Indicate there is a proprietary version which would not be the case.

Outside the issue of Proprietary information FTl commented that the information in the FTl " White paper" on severe accident burst testing needs to be supplemented with additional NDE and destructive examination results.

Preliminary review indicated location of sample R.5.2 may change in Figure 17 of ANL's report. This would improve the interpretation of the data for consistency.

A revised data report was transmitted to ANL (e-mail Transmitted July 12,1999).

l I

A fax was sent to Dwight Diercks on July 11,1999 with additional details I

of FTI's testing. (FTi Document 51-5004960-00)

I j.

Please note there were some changes in the data relative to the results presented in the white paper. The interpretation of failure temperature has l

been discussed with Dr. Muscara and S. Majumdar. The information l

presented in this fax represents the temperature of "significant leakage" versus an earlier value of indicated drop of pressure in the tube. One could argue for either but when comparing modeling results the significant leakage appears to be critical.

The handouts provided in support of Reference 2 contained no designation of FTI-Proprietary information The discussion and dialog was also very open relative to details of the Electrosleeve. The presentation by Mr. Majumdar included revised FTl data, as discussed above.

A revised handout of Mr. Majumdar's presentation was forwarded per Reference

3. This information was discussed in the Report identified in Reference 1, and will change some of the figures.

2 i

Mr. Jack Donohew Page 3 of 3 i

Review of Technical Letter Report for Proprietary Information 9/15/99 l

i 1

i

SUMMARY

i i

Based on'the conference calls, e-mail messages, public meeting, and ANL revised evaluation, the report identified in Reference 1 is most certainly being revised by l

ANL. The technicalinformation relative to sever-accident conditions is judged to

- be non-proprietary. It is anticipated that additional repair evaluations will also be documented in the public domain.

i James E Galford i

Manager, Sleeving Project Team

)