1

-

,

  1. "4r

UNITED STATES

O

t

NUCLEAR REGULATORY COMMISSION

.

4

3

E

j

REGloN IV

b,

[

611 RYAN PLAZA DRIVE, SUITE 400

ARLINGTON, TEXAS 76011-8064

,, g

September 10,1999

Garry L. Randolph, Vice President and

Chief Nuclear Officer

Union Electric Company

P.O. Box 620

Fulton, Missouri 65251

SUBJECT: NRC INSPECTION REPORT NO. 50-483/99-07

Dear Mr. Randolph:

This ret

to the inspection conducted on August 9 to 13,1999, at the Callaway Plant facility.

The enclosed report presents the results of this inspection.

The purpose of this inspection was primarily to evaluate the effectiveness of the licensed

operators' requalification program. The inspectors used the annual licensed operator

requalification examinations to assess licensed operator performance. The inspectors also

evaluated the operations training staff in the development, administration, and evaluation of the

biennial requalification examination. Overall, we observed improved licensed operator

communications during the inspection. The operations training staff developed, and

administered, the requalification examinations professionally and accurately.

We are concerned about the performance of operating crews in the simulator portion of the

operating test. The two crews observed during the inspection both failed to implement timely

corrective actions. We will continue to monitor crew performance indicators and your licensed

operator continuing, training program,

in accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter and its

enclosure will be placed in the NRC Public Document Room (PDR).

Should you have any questions concerning this inspection, we will be pleased to discuss them

with you.

Sincerely,

/{,(e h

W

M John L. Pellet, Chief

'

Operations Branch

Division of Reactor Safety

Docket No.:

50-483

License No.: NPF-30

'

9909200001 990910

.

PDR

ADOCK 05000483

'

G

PDR

.. .. .

.

.

_ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

.

.

Union Electric Company

-2-

Enclosure:

NRC Inspection Report No.

50-483/99-07

cc w/ enclosure:

Gary Czeschin, Training Manager

Union Electric Company

P.O. Box 620

Fulton, Missouri 65251

Professional Nuclear Consulting, Inc.

19041 Raines Drive

Derwood, Maryland 20855

John O'Neill, Esq.

Shaw, Pittman, Potts & Trowbridge

2300 N. Street, N.W.

Washington, D.C. 20037

H. D. Bono, Supervising Engineer

Quality Assurance Regulatory Support

Union Electric Company

P.O. Box 620

,

Fulton, Missouri 65251

Manager - Electric Department

Missouri Public Service Commission

301 W. High

P.O. Box 360

Jefferson City, Missouri 65102

Ronald A. Kucera, Director

of Intergovernmental Cooperation

P.O. Box 176

Jefferson City, Missouri 65102

.

Otto L. Maynard, President and

Chief Executive Officer

i

Wolf Creek Nuclear Operating Corporation

l

P.O. Box 411

Burlington, Kansas 66839

Dan I. Bolef, President

Kay Drey, Representative

Board of Directors Coalite,

for the Environment

6267 Delmar Boulevard

University City, Missouri 63130

. . .

_ _ _ _ _ _ - _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

O

e

Union Electric Company

-3-

Lee Fritz, Presiding Commissioner

Callaway County Court House

10 East Fifth Street

Fulton, Missouri 65151

Alan C. Passwater, Manager

Licensing and Fuels

AmerenUE

One Ameren Plaza

1901 Chouteau Avenue

P.O. Box 66149

St. Louis, Missouri 63166-6149

J. V. Laux, Manager

Quality Assurance

Union Electric Company

P.O. Box 620

Fulton, Missouri 65251

Jerry Uhlmann, Director

State Emergency Management Agency

P.O. Box 116

Jefferson City, Missouri 65101

l

l

l

!

-

_-- -

r -.

..

.

Union Electric Company

4

E-Mail report to T. Frye (TJF)

E-Mail report to D. Lange (DJL)

E-Mail report to NRR Event Tracking System (IPAS)

E-Mail report to Document Control Desk (DOCDESK)

bec to DCD (IE01)

bec distrib. by RIV:

Regional Administrator

Resident inspector

DRP Director

RIV File

DRS Director

RITS Coordinator

Branch Chief (DRP/B)

Project Engineer (DRP/B)

Branch Chief (DRP/TSS)

1

,

l

'

.

i

DOCUMENT NAME: R:\\._CW\\cw907rp.gwj.wpd

To receive copy of document, indicate in box: "C" = Copv without enclosures 'E' = s pMth enclosures "N" = No copy

RIV:3RE:OB

_

RI:PBB

- (! C:OB

M

C:PBBD

C:OB

GWJohnston/imb &

JHanna ths .# JLPelletGWBib WJohnddn

JLPelletv[9

09/q/99

09/?/99 1f6

09#8/99 ' /

09/1999

09/4/99' Y

'

OFFICIAL RECORD COPY

u

7

i ,-

.

Union Electric Company

-4-

l

- E-Mail report to T. Frye (TJF)

.

E-Mail report to D. Lange (DJL)

E-Mail report to NRR Event Tracking System (IPAS)

E-Mail report to Document Control Desk (DOCDESK)

'bec to DCD (IE01) .

bec distrib. by RIV:

Regional Administrator

Resident inspector

'

DRP Director

RIV Filo

DRS Director

RITS Coordinator

Branch Chief (DRP/B)

Project Engineer (DRP/B)

Branch Chief (DRP/TSS)

DOCUMENT NAME: R:\\_CW\\cw907rp.gwj.wpd

To receive copy of document, indicate in box: "C" = Copy without enclosures *E" = CopyMth enclosures *N" = No copy

RIV:SRE:OB

_

RI:PBB

C:OB

M

C:PBB ()

C:OB

GWJohnston/imb bi

JHanna V

/ JLPelletGj@

WJohnsIdn

JLPellet. , d

09/q/99

09/ f/99 ' < '

09/ts/99 ' /-

09/1999

09/4/99'

'I

'

OFFICIAL RECORD COPY