Category:CORRESPONDENCE-LETTERS
MONTHYEARML20217K1051999-10-19019 October 1999 Ack Receipt of Ltr Dtd 990707,which Transmitted Rev 29 to Callaway Plant Physical Security Plan,Under Provisions of 10CFR50.54(p).Based on Determination That Changes Do Not Decrease Effectiveness of Plan,No NRC Approval Required ML20217G2071999-10-14014 October 1999 Forwards Insp Rept 50-483/99-10 on 990913-16.No Violations Noted.Insp Was to Review Emergency Plan & Procedures During Biennial Emergency Preparedness Exercise ML20217B5901999-10-0505 October 1999 Informs That Staff Concludes That Licensee Responses to GL 97-06 Provides Reasonable Assurance That Condition of Util SG Internals in Compliance with Current Licensing Bases for Callaway Plant,Unit 1 ML20217B5711999-10-0505 October 1999 Discusses GL 98-01 Issued by NRC on 980511 & Uec Responses for Callaway NPP Unit 1 ,990224 & 990628.Informs That Staff Reviewed Responses & Concluded That All Requested Info for GL 98-01 Provided ML20212G0221999-09-22022 September 1999 Forwards Insp Rept 50-483/99-11 on 990812-20.No Violations Noted.Team Found,Weakness in flow-accelerated Corrosion Monitoring Program Resulted in No Previous Insp of Pipe Segment Which Failed ML20212D9341999-09-16016 September 1999 Informs That on 990818,NRC Completed Midcycle PPR of Callaway Plant.In Area of Ep,C/As Taken in Response to Problems Identified During Previous Exercises Warrant More in-dept Review.Details of Insp Plan Through March 2000 Encl ML20217D5791999-09-15015 September 1999 Provides Formal Documentation of Reviews & Discussions Re Technical Ltr Rept for Proprietary Info.Review of Ltr Was Discussed in Telcon & Via e-mail Messages. Summary of Telcons as Documented on 990708,included ML20212A4921999-09-13013 September 1999 Forwards Insp Rept 50-483/99-08 on 990725-0904.Two Severity Level IV Violations of NRC Requirements Identified & Being Treated as Noncited Violations Consistent with App C of Enforcement Policy ML20212A4701999-09-10010 September 1999 Rssponds to NRC 990709 RAI Re Util Relief Request to Allow Use of 1998 Edition of ASME Section Xi,Subsection Iwe. Acceptance Criteria for Liner Plate Pressure Boundary Thickness Will Be Limited to 10% Nominal Thinning ML20212B1521999-09-10010 September 1999 Forwards Insp Rept 50-483/99-07 on 990809-13.No Violations Noted.Inspectors Used Annual Licensed Operator Requalification Exams to Assess Licensed Operator Performance ML20211N0321999-09-0202 September 1999 Forwards SE Concluding That Util Adequately Addressed Actions Requested in GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves ML20211B0241999-08-18018 August 1999 Ack Receipt of Ltr Dtd 990714,transmitting Scenario for Licensee Upcoming Biennial Exercise.Based on Review,Nrc Determined That Exercise Scenario Sufficient to Meet Emergency Plan Requirements & Exercise Objectives ML20210T9121999-08-13013 August 1999 Forwards Insp Rept 50-483/99-06 on 990613-0724.One Severity Level 4 Violation Occurred & Being Treated as Ncv,Consistent with App C of Enforcement Policy ML20210R7241999-08-12012 August 1999 Forwards semi-annual Fitness for Duty Program Performance Data Rept for Callaway Nuclear Plant for 990101-990630,IAW 10CFR26.71(d) ML20211A9501999-08-12012 August 1999 Discusses 990720-21 Workshop Conducted in Region IV Ofc,Re Exchange of Info in Area of Use of Risk Insights in Regulatory Activities.List of Attendees,Summary of Topic & Issues,Agenda & Copies of Handouts Encl ULNRC-04085, Forwards Rev 4 to Callaway Plant Cycle 10 COLR, Per TS 6.9.1.9.COLR Has Been Revised to Update Rod Bank Insertion (Ril) Limits,As Function of Rated Thermal Power1999-08-11011 August 1999 Forwards Rev 4 to Callaway Plant Cycle 10 COLR, Per TS 6.9.1.9.COLR Has Been Revised to Update Rod Bank Insertion (Ril) Limits,As Function of Rated Thermal Power ML20210P0371999-08-10010 August 1999 Forwards SE Granting Licensee 980710 Requests for Relief (ISI-13 - ISI-18) from Requirements of Section XI of 1989 Edition of ASME B&PV Code for Second 10-year Interval ISI at Plant,Unit 1 ML20210L1461999-08-0303 August 1999 Informs That NRC Plans to Administer Gfes of Written Operator Licensing Exam on 991006.Requests Submittal of Ltr Identifying Individuals Taking Exam,Personnel Allowed Access to Exams & Mailing Address for Exams ULNRC-04079, Forwards 180-day Response to NRC GL 99-02, Lab Testing of Nuclear-Grade Activated Charcoal1999-08-0202 August 1999 Forwards 180-day Response to NRC GL 99-02, Lab Testing of Nuclear-Grade Activated Charcoal ML20210H6381999-07-30030 July 1999 Forwards SE Accepting Relief Request for Approval for Use of Alternate Exam Requirement for Plant Inservice Insp Program A93443, Forwards Addl Info as Committed to in Telcon Between Amerenue & NRC Personnel on 990616,re GL 95-07, Pressure Locking & Thermal Binding of MOV Gate Valves1999-07-28028 July 1999 Forwards Addl Info as Committed to in Telcon Between Amerenue & NRC Personnel on 990616,re GL 95-07, Pressure Locking & Thermal Binding of MOV Gate Valves ULNRC-04075, Forwards Response to NRC 990618 RAI Re GL 96-05, Periodic Verification of Design-Basis Capability of SR Motor-Operated Valves1999-07-28028 July 1999 Forwards Response to NRC 990618 RAI Re GL 96-05, Periodic Verification of Design-Basis Capability of SR Motor-Operated Valves ULNRC-04076, Informs of Implementation of Amend 131 to License NPF-30, Revising OL to Reflect Requirement in TS 3/4.7.1.7 for Four Operable ASD Lines & Associated Revs,Rather than Three Operable ASDs1999-07-28028 July 1999 Informs of Implementation of Amend 131 to License NPF-30, Revising OL to Reflect Requirement in TS 3/4.7.1.7 for Four Operable ASD Lines & Associated Revs,Rather than Three Operable ASDs ULNRC-04070, Forwards Rev 3 to Callaway Plant Cycle 10 COLR, IAW TS 6.9.1.9.COLR Has Been Revised to Update RAOC Axial Flux Difference (Afd) Limits,As Function of Rated Thermal Power1999-07-27027 July 1999 Forwards Rev 3 to Callaway Plant Cycle 10 COLR, IAW TS 6.9.1.9.COLR Has Been Revised to Update RAOC Axial Flux Difference (Afd) Limits,As Function of Rated Thermal Power 05000483/LER-1998-008, Forwards Amended Response to GL 81-07, Control of Heavy Loads, to Address Corrective Action Described in LER 98-008-00.Discrepancy Between Earlier Submittals of Snupps Rept on Control of Heavy Loads & TS Re RHR Sys,Resolved1999-07-27027 July 1999 Forwards Amended Response to GL 81-07, Control of Heavy Loads, to Address Corrective Action Described in LER 98-008-00.Discrepancy Between Earlier Submittals of Snupps Rept on Control of Heavy Loads & TS Re RHR Sys,Resolved ULNRC-04071, Informs That Util Anticipates Approx Ten Licensing Actions That Could Occur During Fys 2000 & 2001,in Response to Administrative Ltr 99-021999-07-27027 July 1999 Informs That Util Anticipates Approx Ten Licensing Actions That Could Occur During Fys 2000 & 2001,in Response to Administrative Ltr 99-02 ML20210B5611999-07-20020 July 1999 Forwards Review of Ltr & Encl Objectives for Plant,Unit 1,1999 Emergency Plan Exercise Scheduled for 990914 ML20210B4021999-07-19019 July 1999 Ack Receipt of Facility Emergency Plan Implementing Procedure EIP-ZZ-00101, Classification of Emergencies, Rev 23,issued on 990513,under Provisions of 10CFR50,App E, Section V ML20210B4401999-07-19019 July 1999 Ack Receipt of Revs to Facility Radiological Emergency Response Plan,Chapters 8.0 & 4.0,issued Respectively on 990512-14,under Provisions of 10CFR50,App E,Section V ML20212A3291999-07-15015 July 1999 Forwards Scenario Manual Containing Description of Callaway Plant 1999 Biennial Emergency Response Plan Exercise to Be Conducted 990914.Correspondence to Satisfy 60-day Submittal Requirement ML20209F3471999-07-0909 July 1999 Forwards Response to NRC 990624 RAI to Complete NRC Review of Relief Request to Allow Use of 1998 Edition of ASME Section Xi,Subsection IWE ML20209E5591999-07-0808 July 1999 Informs That as Result of NRC Review of Util Responses to GL 92-01,rev 1,suppl 1 & Suppl 1 Rai,Staff Revised Info in Reactor Vessel Integrity Database & Releasing Database as Rvid Version 2.TAC MA0531 Closed ML20209H2471999-07-0707 July 1999 Forwards Rev 29 to Physical Security Plan,Per 10CFR50.54(p). Rev Withheld,Per 10CFR73.21 ML20196J9501999-07-0202 July 1999 Ack Receipt of Plant Ep,Rev 22,received on 981207 & Submitted Under Provision of 10CFR50,App E,Section V.Changes Does Not Decrease Effectiveness of EP & Continues to Meet Stds of 10CFR50.47(b).NRC Approval Not Required ML20209B6851999-06-28028 June 1999 Responds to GL 98-01,Suppl 1, Y2K Readiness of Computer Systems at Nuclear Power Plants. Disclosure Rept Encl ML20209C0171999-06-28028 June 1999 Forwards Special Rept 99-01 Re Fifteenth Year Inservice Containment Bldg Tendon Surveillance Failure.Observed Voids in Sheathing Filler Grease Do Not Indicate Degradation of post-tensioning Sys,Based on Encl Evaluation ML20196F8101999-06-25025 June 1999 Informs That J Donohew Will Assume Project Manager Responsibilities,Effective 990621 ML20196H2521999-06-25025 June 1999 Forwards Insp Rept 50-483/99-05 on 990502-0612.Two Violations Occurred & Being Treated as Noncited Violations, Consistent with App C of Enforcement Policy ML20196F8181999-06-24024 June 1999 Forwards RAI Re 990111 Request for Relief from Certain ASME Code ISI Requirements for Containment Liners.Response Requested within 30 Days from Date of Agreement ML20196G5621999-06-21021 June 1999 Informs NRC of Implementation of Amend 132 to Callaway License NPF-30 to Allows Installation of Electrosleeves for Steam Generator Tube Repair for Two Cycles Following Installation of First Electrosleeve IR 05000483/19990041999-06-18018 June 1999 Refers to GL 96-05 Issued by NRC on 960918,UE Responses & 970313 & NRC Insp Rept 50-483/99-04,dtd 990427. Forwards Request for Addl Info Re GL 96-05 Program at Callaway Plant,Unit 1 ML20212J2441999-06-18018 June 1999 Submits Request for Alternate Exam Requirements for Plant Re ISI Program Plan.Plant Does Not Torque Bolted Connections to Stress Values Greater than 100 Ksi ML20195H0971999-06-14014 June 1999 Discusses Une 990407 Request That Proprietary Document Entitled, Thermal Stability Assessment - Electrosleeved Tubes, Be Withheld from Public Disclosure.Determined Info to Be Proprietary & Will Be Withheld from Public Disclosure ML20207H3751999-06-14014 June 1999 Discusses 990407 Une Request That Proprietary Version of Document Entitled, Evaluation of Severe Accident Simulation, Dtd April 1999,be Withheld from Public Disclosure.Determined Info Proprietary & Will Be Withheld ML20195H9731999-06-11011 June 1999 Forwards Requested Addl Info Related to Relief Request ISI-16,encountered During Refuel 9 ML20195J9301999-06-0808 June 1999 Informs That Refuel 9 OAR-1 Owners Data Rept for ISI & Summary Rept for Interval 2 Was Submitted with Typographical Error,In That Commercial Service Date Should Be 841219,vice 941219.Please Substitute Encl Corrected Document ML20207G3201999-06-0707 June 1999 Ack Receipt of Change Notice 98-008 Dtd 980918,which Transmitted Changes to Callaway Plant Ep,Rev 21,under Provisions of 10CFR50,App E,Section V.No NRC Approval Required.No Violations Identified ML20207G3151999-06-0707 June 1999 Ack Receipt of Callaway Plant EP Implementing Procedure EIP-ZZ-001001M,Classification of Emergencies,Rev 22,issued on 981222 Under 10CFR50,App E,Section V Provisions.No Violations Identified ML20195C5131999-05-28028 May 1999 Forwards Revs to Sections 3.9 & 5.6 of Its,Based on Resolution Telcons Held Between NRC Staff & Util on 990526 & 27 A98803, Forwards Certified ITS & ITS Bases for Callaway Plant,In Response to NRC 990402 Draft SE for License Amend to Convert TSs to Format & Expanded Bases of ITS1999-05-27027 May 1999 Forwards Certified ITS & ITS Bases for Callaway Plant,In Response to NRC 990402 Draft SE for License Amend to Convert TSs to Format & Expanded Bases of ITS 1999-09-22
[Table view] Category:INCOMING CORRESPONDENCE
MONTHYEARML20217D5791999-09-15015 September 1999 Provides Formal Documentation of Reviews & Discussions Re Technical Ltr Rept for Proprietary Info.Review of Ltr Was Discussed in Telcon & Via e-mail Messages. Summary of Telcons as Documented on 990708,included ML20212A4701999-09-10010 September 1999 Rssponds to NRC 990709 RAI Re Util Relief Request to Allow Use of 1998 Edition of ASME Section Xi,Subsection Iwe. Acceptance Criteria for Liner Plate Pressure Boundary Thickness Will Be Limited to 10% Nominal Thinning ML20210R7241999-08-12012 August 1999 Forwards semi-annual Fitness for Duty Program Performance Data Rept for Callaway Nuclear Plant for 990101-990630,IAW 10CFR26.71(d) ULNRC-04085, Forwards Rev 4 to Callaway Plant Cycle 10 COLR, Per TS 6.9.1.9.COLR Has Been Revised to Update Rod Bank Insertion (Ril) Limits,As Function of Rated Thermal Power1999-08-11011 August 1999 Forwards Rev 4 to Callaway Plant Cycle 10 COLR, Per TS 6.9.1.9.COLR Has Been Revised to Update Rod Bank Insertion (Ril) Limits,As Function of Rated Thermal Power ULNRC-04079, Forwards 180-day Response to NRC GL 99-02, Lab Testing of Nuclear-Grade Activated Charcoal1999-08-0202 August 1999 Forwards 180-day Response to NRC GL 99-02, Lab Testing of Nuclear-Grade Activated Charcoal ULNRC-04075, Forwards Response to NRC 990618 RAI Re GL 96-05, Periodic Verification of Design-Basis Capability of SR Motor-Operated Valves1999-07-28028 July 1999 Forwards Response to NRC 990618 RAI Re GL 96-05, Periodic Verification of Design-Basis Capability of SR Motor-Operated Valves A93443, Forwards Addl Info as Committed to in Telcon Between Amerenue & NRC Personnel on 990616,re GL 95-07, Pressure Locking & Thermal Binding of MOV Gate Valves1999-07-28028 July 1999 Forwards Addl Info as Committed to in Telcon Between Amerenue & NRC Personnel on 990616,re GL 95-07, Pressure Locking & Thermal Binding of MOV Gate Valves ULNRC-04076, Informs of Implementation of Amend 131 to License NPF-30, Revising OL to Reflect Requirement in TS 3/4.7.1.7 for Four Operable ASD Lines & Associated Revs,Rather than Three Operable ASDs1999-07-28028 July 1999 Informs of Implementation of Amend 131 to License NPF-30, Revising OL to Reflect Requirement in TS 3/4.7.1.7 for Four Operable ASD Lines & Associated Revs,Rather than Three Operable ASDs 05000483/LER-1998-008, Forwards Amended Response to GL 81-07, Control of Heavy Loads, to Address Corrective Action Described in LER 98-008-00.Discrepancy Between Earlier Submittals of Snupps Rept on Control of Heavy Loads & TS Re RHR Sys,Resolved1999-07-27027 July 1999 Forwards Amended Response to GL 81-07, Control of Heavy Loads, to Address Corrective Action Described in LER 98-008-00.Discrepancy Between Earlier Submittals of Snupps Rept on Control of Heavy Loads & TS Re RHR Sys,Resolved ULNRC-04070, Forwards Rev 3 to Callaway Plant Cycle 10 COLR, IAW TS 6.9.1.9.COLR Has Been Revised to Update RAOC Axial Flux Difference (Afd) Limits,As Function of Rated Thermal Power1999-07-27027 July 1999 Forwards Rev 3 to Callaway Plant Cycle 10 COLR, IAW TS 6.9.1.9.COLR Has Been Revised to Update RAOC Axial Flux Difference (Afd) Limits,As Function of Rated Thermal Power ULNRC-04071, Informs That Util Anticipates Approx Ten Licensing Actions That Could Occur During Fys 2000 & 2001,in Response to Administrative Ltr 99-021999-07-27027 July 1999 Informs That Util Anticipates Approx Ten Licensing Actions That Could Occur During Fys 2000 & 2001,in Response to Administrative Ltr 99-02 ML20212A3291999-07-15015 July 1999 Forwards Scenario Manual Containing Description of Callaway Plant 1999 Biennial Emergency Response Plan Exercise to Be Conducted 990914.Correspondence to Satisfy 60-day Submittal Requirement ML20209F3471999-07-0909 July 1999 Forwards Response to NRC 990624 RAI to Complete NRC Review of Relief Request to Allow Use of 1998 Edition of ASME Section Xi,Subsection IWE ML20209H2471999-07-0707 July 1999 Forwards Rev 29 to Physical Security Plan,Per 10CFR50.54(p). Rev Withheld,Per 10CFR73.21 ML20209C0171999-06-28028 June 1999 Forwards Special Rept 99-01 Re Fifteenth Year Inservice Containment Bldg Tendon Surveillance Failure.Observed Voids in Sheathing Filler Grease Do Not Indicate Degradation of post-tensioning Sys,Based on Encl Evaluation ML20209B6851999-06-28028 June 1999 Responds to GL 98-01,Suppl 1, Y2K Readiness of Computer Systems at Nuclear Power Plants. Disclosure Rept Encl ML20196G5621999-06-21021 June 1999 Informs NRC of Implementation of Amend 132 to Callaway License NPF-30 to Allows Installation of Electrosleeves for Steam Generator Tube Repair for Two Cycles Following Installation of First Electrosleeve ML20212J2441999-06-18018 June 1999 Submits Request for Alternate Exam Requirements for Plant Re ISI Program Plan.Plant Does Not Torque Bolted Connections to Stress Values Greater than 100 Ksi ML20195H9731999-06-11011 June 1999 Forwards Requested Addl Info Related to Relief Request ISI-16,encountered During Refuel 9 ML20195J9301999-06-0808 June 1999 Informs That Refuel 9 OAR-1 Owners Data Rept for ISI & Summary Rept for Interval 2 Was Submitted with Typographical Error,In That Commercial Service Date Should Be 841219,vice 941219.Please Substitute Encl Corrected Document ML20195C5131999-05-28028 May 1999 Forwards Revs to Sections 3.9 & 5.6 of Its,Based on Resolution Telcons Held Between NRC Staff & Util on 990526 & 27 A98803, Forwards Certified ITS & ITS Bases for Callaway Plant,In Response to NRC 990402 Draft SE for License Amend to Convert TSs to Format & Expanded Bases of ITS1999-05-27027 May 1999 Forwards Certified ITS & ITS Bases for Callaway Plant,In Response to NRC 990402 Draft SE for License Amend to Convert TSs to Format & Expanded Bases of ITS ML20196L2911999-05-19019 May 1999 Forwards Responses to NRC 990315 RAI Concerning GL 95-07, Pressure Locking & Thermal Binding of MOV Gate Valves A36791, Forwards Response to NRC 990510 RAI Re GL 96-06 with Respect to Analysis of Water Hammer & two-phase Flow Issues. Supporting Calculation Also Encl1999-05-17017 May 1999 Forwards Response to NRC 990510 RAI Re GL 96-06 with Respect to Analysis of Water Hammer & two-phase Flow Issues. Supporting Calculation Also Encl ULNRC-04034, Forwards Amerenues Risk Evaluation Summary & Provides Listing of Other Documents Which Have Been Previously Provided to Support Evaluation of Electrosleeves at High Temp Severe Accident Conditions1999-05-17017 May 1999 Forwards Amerenues Risk Evaluation Summary & Provides Listing of Other Documents Which Have Been Previously Provided to Support Evaluation of Electrosleeves at High Temp Severe Accident Conditions 05000483/LER-1998-003, Forwards LER 98-003-01 Re Inadvertent Actuation of ESFAS Due to 'A' SG High Level During Refuel 9.Rept Is Submitted to Report Change in C/A from That Reported in Original Rept1999-05-12012 May 1999 Forwards LER 98-003-01 Re Inadvertent Actuation of ESFAS Due to 'A' SG High Level During Refuel 9.Rept Is Submitted to Report Change in C/A from That Reported in Original Rept ML20206Q9551999-05-12012 May 1999 Responds to NRC Re Violations Noted in Insp Rept 50-483/99-04.Corrective Actions:Une Commits to Make Available for NRC Review,Action Plan Outlining Scope & Completion Dates of Project ULNRC-04027, Forwards Comments on Draft SE Re Proposed Conversion to Improved Tss.Copy of ITS & ITS Bases Will Be Provided by 990524,to Support Issuance of License Amend on or About 9905281999-05-0404 May 1999 Forwards Comments on Draft SE Re Proposed Conversion to Improved Tss.Copy of ITS & ITS Bases Will Be Provided by 990524,to Support Issuance of License Amend on or About 990528 ML20206E3211999-04-28028 April 1999 Forwards Special Rept 98-03 Re Inservice Insp of CP Sgs,Per Plant TS 4.4.5.5.b.Insp Was Performed in Apr 1998 During Plant Ninth Refueling Outage.Rept Is Being Resubmitted Due to Typos in Original Rept ML20206E5781999-04-23023 April 1999 Informs That R Schukai Is No Longer Employed with Amerenue & Info Sent Is No Longer Required.Name Should Be Removed from Mailing Lists.Mailing Label Used by Company Which May Assist in Matter,Submitted ULNRC-04018, Submits follow-up Items Re Proposed Conversion to ITS Sections 1.0,3.3,3.4,3.6,3.7 & 3.9.Suppl to Ltr Will Be Submitted at Later Date1999-04-21021 April 1999 Submits follow-up Items Re Proposed Conversion to ITS Sections 1.0,3.3,3.4,3.6,3.7 & 3.9.Suppl to Ltr Will Be Submitted at Later Date ML20205Q7751999-04-16016 April 1999 Forwards Special Rept 98-03 Concerning ISI of Callaway SGs Performed in Apr 1998 During Callaway Plants Ninth Ro. Rept Documents Final SG Insp Results ULNRC-04015, Forwards Cash Flow Projection & Certification to Satisfy Guarantee of Payment of Retrospective Premiums,Per 10CFR140.211999-04-15015 April 1999 Forwards Cash Flow Projection & Certification to Satisfy Guarantee of Payment of Retrospective Premiums,Per 10CFR140.21 ULNRC-04005, Forwards Proprietary & non-proprietary White Paper Entitled, Evaluation of Severe Accident Simulation, as Addl Info to Facilitate Approval of Requested Amend to Revise TS to Use Repair SG Tubes.Proprietary Info Withheld,Per 10CFR2.7901999-04-0707 April 1999 Forwards Proprietary & non-proprietary White Paper Entitled, Evaluation of Severe Accident Simulation, as Addl Info to Facilitate Approval of Requested Amend to Revise TS to Use Repair SG Tubes.Proprietary Info Withheld,Per 10CFR2.790 ULNRC-04004, Forwards Proprietary Thermal Stability Background Data Along with Time/Temp Graph Requested in 990402 Telcon with NRC & Contractor,Argonne Natl Lab.Proprietary Info Withheld1999-04-0707 April 1999 Forwards Proprietary Thermal Stability Background Data Along with Time/Temp Graph Requested in 990402 Telcon with NRC & Contractor,Argonne Natl Lab.Proprietary Info Withheld ULNRC-04007, Submits follow-up Items Related to Proposed Conversion to ITSs Sections 3.3,3.4,3.6 & 3.7.Encl Includes mark-ups of ITS Sections 3.5,3.6 & 3.8.Suppl to Ltr Will Be Provided at Later Date1999-04-0707 April 1999 Submits follow-up Items Related to Proposed Conversion to ITSs Sections 3.3,3.4,3.6 & 3.7.Encl Includes mark-ups of ITS Sections 3.5,3.6 & 3.8.Suppl to Ltr Will Be Provided at Later Date ULNRC-04000, Forwards Rept Re Present Level of Insurance & Sources of Insurance Applicable to Callaway Plant,Per 10CFR50.54(w)1999-04-0101 April 1999 Forwards Rept Re Present Level of Insurance & Sources of Insurance Applicable to Callaway Plant,Per 10CFR50.54(w) ULNRC-03998, Forwards Required Financial Info Re Decommissioning Callaway Nuclear Plant,Per 10CFR50.751999-03-30030 March 1999 Forwards Required Financial Info Re Decommissioning Callaway Nuclear Plant,Per 10CFR50.75 ML20205G2211999-03-25025 March 1999 Submits Rev 28A to Callaway Plant Physical Security Plan, Incorporating Addendum Re Security Sys Replacement Transition Plan,Per 10CFR50.54(p).Encl Withheld,Per 10CFR73.21 ML20205R5251999-03-25025 March 1999 Forwards Special Rept 98-03 Re Results of Tenth SG Tube Inservice Insp,Per Requirements of Plant TS 4.4.5.5.b.Insp Was Performed in Apr 1998 During Plant Ninth Refueling Outage ULNRC-03988, Requests Approval of Alternative Exam ISI-12A Per 10CFR50.55a(a)(3)(i) & (II) for 1989 Edition of ASME Section IX,IWA-5242(a) for Class I Bolted Connections Inside Bioshield for RFO 101999-03-19019 March 1999 Requests Approval of Alternative Exam ISI-12A Per 10CFR50.55a(a)(3)(i) & (II) for 1989 Edition of ASME Section IX,IWA-5242(a) for Class I Bolted Connections Inside Bioshield for RFO 10 ULNRC-03991, Forwards 1998 Annual Rept of Individual Monitoring Results, Per 10CFR20.2206.Rept Provided in Electronic Format on Diskette IAW Gudiance of Reg Guide 8.7.Without Diskette1999-03-19019 March 1999 Forwards 1998 Annual Rept of Individual Monitoring Results, Per 10CFR20.2206.Rept Provided in Electronic Format on Diskette IAW Gudiance of Reg Guide 8.7.Without Diskette ML20204F7211999-03-17017 March 1999 Forwards Amended Fitness for Duty Program Performance Data for Six Month Period Beginning Jul-Dec 1998 ML20204E1331999-03-17017 March 1999 Responds to NRC Re Violations Noted in Insp Rept 50-483/99-02 on 990208-12.Corrective Actions:Will Revise Security Plan to Increase Min Staffing by Three Armed Security Force Response Personnel Per Shift ML20207C3631999-03-12012 March 1999 Forwards Exam Matl & Associated QA Checklist for Written Exam to Support Plant RO Retake Exam Scheduled for 990423. Exam Matls Requested to Be Withheld from Public Disclosure Until After Exam Completion 05000483/LER-1998-001, Forwards LER 98-001-01,being Submitted to Clarify Scope of Original Reviews Performed for Corrective Action Number 3 in LER 98-001-00.Reviews Have Identified Case of Failure to Properly Establish Equipment Operability1999-03-10010 March 1999 Forwards LER 98-001-01,being Submitted to Clarify Scope of Original Reviews Performed for Corrective Action Number 3 in LER 98-001-00.Reviews Have Identified Case of Failure to Properly Establish Equipment Operability ULNRC-03979, Submits follow-up Items Related to Proposed Conversion to ITSs Sections 3.3,3.4,3.6,3.7,3.8,3.9 & 5.0.Suppl to Ltr Dtd 970515,will Be Provided at Later Date1999-03-0909 March 1999 Submits follow-up Items Related to Proposed Conversion to ITSs Sections 3.3,3.4,3.6,3.7,3.8,3.9 & 5.0.Suppl to Ltr Dtd 970515,will Be Provided at Later Date ULNRC-03975, Informs of No Reportable ECCS Evaluation Model Revs for Callaway During Time Period from Mar 1998 to Mar 1999,IAW 10CFR50.46.ECCS Evaluation Model Margin Assessment Encl1999-03-0505 March 1999 Informs of No Reportable ECCS Evaluation Model Revs for Callaway During Time Period from Mar 1998 to Mar 1999,IAW 10CFR50.46.ECCS Evaluation Model Margin Assessment Encl ULNRC-03971, Forwards Annual Personnel Exposure & Monitoring Rept for 1998, Per TS Sections 6.9.1.4 & 6.9.1.5.Rept Includes One Incident of Specific Activity Analysis of RCS in Which Limits of TS 3.4.8 Were Exceeded1999-02-26026 February 1999 Forwards Annual Personnel Exposure & Monitoring Rept for 1998, Per TS Sections 6.9.1.4 & 6.9.1.5.Rept Includes One Incident of Specific Activity Analysis of RCS in Which Limits of TS 3.4.8 Were Exceeded ML20207A4311999-02-17017 February 1999 Forwards semi-annual Fitness for Duty Program Performance Data Rept for Callaway Nuclear Plant for Period of 980701-981231 1999-09-15
[Table view] |
LER-2098-008, Forwards Amended Response to GL 81-07, Control of Heavy Loads, to Address Corrective Action Described in LER 98-008-00.Discrepancy Between Earlier Submittals of Snupps Rept on Control of Heavy Loads & TS Re RHR Sys,Resolved |
Event date: |
|
---|
Report date: |
|
---|
4832098008R00 - NRC Website |
|
text
, - - _ _ _ ___ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ - _ - _ _ .
Union Eltctric Po Box 620
- Callaway ftant Fulton, MO 65251 July 27,1999 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop Pl-137 Washington, DC 20555-0001 ULNRC-4056 Gentlemen:
$l.
'ilygg DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UE UNION EttCTRiC CO.
FACILITY OPERATING LICENSE NPF-30 AMENDED RESPONSE TO GENERIC LETTER 81-07," CONTROL OF HEAVY LOADS"
References:
- 1) Generic Letter 81-07, " Control of Heavy Loads", dated December 22, 1980, along v.ith NUREG-0612 enclosure
- 2) SLNRC 31-48, SNUPPS Response to Generic Letter 81-07 (Phase I),
dated June 22,1981
- 3) SLNRC 82-33, Final SNUPPS Response to Generic Letter 81-07
" Control of Heavy Loads", dated August 4,1983
- 4) SLNRC 84-08, Revision 1 to SNUPPS Report on " Control of Heavy Loads", dated January 27,1984
- 5) SLNRC 84-56, Revision 2 to SNUPPS Report on " Control of Heavy Loads", dated March 28,1984
- 6) SLNRC 85-19, Revision 3 to SNUPPS Report on " Control of Heavy Loads", dated June 12,1985
- 7) NUREG-0830, Supplement No. 3, " Safety Evaluation Report related to the operation of Callaway Plant, Unit No.1", dated May 1984 y
- 8) ULNRC-3894," Licensee Event Report 98-008-00", dated September 14, U 1998 Attachment I provides an amended response to Generic Letter 81-07, " Control of Heavy Loads", to address corrective action described in Licensee Event Report 98- \
008-00 which was submitted to the ~NRC via Reference 8 above. The attachment U O
resolves a discrepancy between earlier submittats of the "SNUPPS Report on the Control of Heavy Loads" and Callaway Plant Technical Specifications regarding Residual Heat Removal (RHR) system operability and protection during Cold Shutdown (Mode 5) and Refueling (Mode 6). The changes to Callaway's response 9908110160 990727 PDR ADOCK 05000483 P PDR o subsidiary of Amoren Corporation L_..._.......
n:-
ULNRC-4056 Page 2 are consistent with the guidance of Reference 1 above, and provide assurance that decay heat removal capability will be maintained in the event of a dropped heavy load.
Please contact Mr. Rick L. Rice at (573) 676 8495 ifyou have any questions.
)
M. E. Tay r Manager, 'uclear Engineering MET S LB/RLR/kkm Enclosure i
l
, Attachment I to ULNRC-4056 Page1 of6 AMENDED RESPONSE TO GENERIC LETTER 81-07 Introduction NRC Generic Letter (GL) 81-07 was issued on December 22,1980 along with enclosure NUREG-0612, " Control of Heavy Loak at Nuclear Power Plants" Guidance for a Phase I (6-month) response and a Phase II (9-month) response was provided. The Callaway Plant 6-month response (Phase I) was submitted to the NRC under the cover of SLNRC 81-48 dated June 22,1981 (Reference 2). The Callaway Plant 9-month response (Phase II) was submitted to the NRC under the cover of SLNRC 82-33 dated August 4,1983 (Reference 3). The Phase II response was re-submitted with additional information in letters SLNRC 84-08 (Reference 4), SLNRC 84-56 (Reference 5) and SLNRC 85-19 (Reference 6).
The NRC reviewed the Callaway Phase I and II responses and found them to be acceptable, as documented in Appendix G and H of Supplement 3 to NUREG-0830 (Reference 7). Callaway was one of five plant sites selected by the NRC to have the Phase II response fully reviewed under a pilot program. Subsequently, Generic Letter (GL) 85-11 informed licensees that, based upon the improvements in heavy loads handling after the implementation of NUREG-0612 (Phase I), further action was not required to reduce the risks associated with the handling of heavy loads. The NRC determined that a detailed Phase II review of heavy loads was not necessary for any additional plants.
Summary of Channes to Callaway's Response With this submittal, Callaway Plant is providing a change to our Phase Il response submitted via SLNRC 82-33, and subsequent revisions, as described above. The change corrects a statement in Section 2.4.1 of the "SNUPPS Report on the Control of Heavy Loads" regarding Residual Heat Removal (RHR) system operability in Modes 5 and 6.
The amended response provides clarification that, per Technical Specifications, only one train of RHR is required to be operable during certain conditions in Modes 5 and 6.
Information is provided to demonstrate that decay heat removal will be maintained in the event of a dropped heavy load inside the Reactor Building (containment), using the guidance provided in NUREG-0612.
The original Phase II response given in Section 2.4.1 (Specific Analyses in the Reactor Building) regarding the polar crane use during cold shutdown stated that "The plant conditions and operable systems are assumed to be in accordance with the Technical Specifications which require both RHR trains to be operable during Mode 5." Later discussion regarding polar crane use during refueling stated that "Should a heavy load drop impact an operating RHR line or a Class I branch line, the effects would be no more severe than the cases discussed above for the cold shutdown mode" Per Callaway Plant approved Technical Specifications, only one train of RHR is required to be operable in Mode 5 with steam generator primary loops filled and a specified minimum secondary side
1 L, Attachment I to ULNRC-4056 Page 2 of 6 l
. water level. Likewise, only one train ofRHR is required to be operable in Mode 6 with greater than 23 feet ofwater above the reactor vessel flange. Per this attachment, Section i 2.4.1 is revised as shown below to clarify RHR system operability requirements and to describe features which ensure that decay heat removal capability will be mahtained per )
the criteria ofNUREG-0612. 4 4
Callaway Plant staff has e auated the effects of a heavy load drop on the plant with only )
one RHR train opuoli a Modes 5 and 6. Piping and building structure layout drawings !
ht ce been reviued acag with normal and off-normal procedures involving RHR systein operation. Although intervening floor and wall structures (3 floor levels) would 11ely prevent most heavy load liAs from causing damage to RCS or RHR piping systems in the !
lower part of the Reactor Building, no formal analyses have been performed and the floors l l were all assumed to fait per the original A/E design firm (Bechtel). Some heavy loads of a larger magnitude (reactor coolant pump motor, pump internals, concrete slabs, etc.) will also be lifted throughout the life of the plant and will be carefully planned and executed.
However, the same floor failure assumption is utilized as that which was used in the i original submittal. Any break of RHR, RCS or other Class I branch piping would result in
, . a non-flashing fluid loss to the containment floor and sumps. Although motor-operated isolation valves in RHR return piping and check valves in RHR supply piping may provide isolation 'of any fluid leak path for a damaged RHR train, the availability of these i componenta depends on the location of the dropped load. As described below, decay heat removal capability could be lost in Modes 5 and 6 when only one train of RHR is maintained operable and in service. Therefore, administrative controle will be implemented to exch6 lifting of heavy loads over piping for a single operable RHR train in the Reactor Builig (i.e. safe load paths will be added) except as described later for specially controlled lifts. Manual re-alignment of the suction source for the single eperable RHR train may be required to maintain long-term decay heat removal. The
. RWST or containment recirculation sumps will be available to provide the necessary suction sources if needed, and will be utilized via off-normal operating procedures. The change to Callaway Plant response for the " Control of Heavy Loads" is consistent with the guidance of GL 81-07 and NUREG-0612 (Reference 1).
Amended Section 2.4.1. "SNUPPS Report.en_the Control of Heavy Loads" 2.4.1 ANALYSSS OF THE REACTOR BUILDING The heavy loads drop analyses for decay heat removal and maintenance of cold shutdcwn conditions inside the reactor building were performed and resulted in no design changes to the plant. The l
following discussions describe the analyses of each crane and load drop inside the reactor building.
Polar Crane Durinn Cold Shutdown - The polar crane could be used during cold shutdown to lift any load not directly associated with the reactor coolant pressure boundary inside the containment. The plant conditions and operable systems are assumed to be in accordance with the Technical Specifications which require both RHR trains to be operable during Mode 5 with steam generator primary loops not filled. Only one operable RHR train is required if the loops are fLd and at least two i-LU
Attachment I to ULNRC-4056 Page 3 of 6
' steam generators contain a secondary side water level specified in the Technical Specifications. The RHR system is the operating system normally irged for the maintenance of cold shutdown conditions. The accumulators have been isolated. The primary system has been cooled to less than 200 F, and the pressure boundary is intact before the postulated drop occurs. Therefore, pipe rupture due to a postulated load drop during cold shutdown will result in non-flashing break flow.
Polar crane heavy bad drops outside of the secondary shield wall could damage either of two redundant RHR pipmg systems, but not both due to physical separation between trains. If both trains of RHR are operable, the damaged train could be secured and the redundant RHR train would be available. For a rupture of the RHR supply line (RCS loop injection), check valves inside the secondary shield wall will restrict alternate train flow through the break location. For a rupture of the RHR eturn line (RCS loop return), remote isolation of the break could occur via motor-operated valves inside the secondary shield wall if the "B" train power supply is available. Otherwise, RCS fluid would discharge to the containment floor and recirculation sumps. However, decay heat removal capability would still be available since the alternate RHR train would be started and force flow through the reactor vessel core (core barrel design routes inlet flow down the outside and up through the core before exiting the hot leg break location). RHR suction would be aligned to the RWST or recirculation sump via off-normal plant procedures to provide long-term cooling. If only one train of RHR is operable, and in operation, a rupture ofits associated supply or return line could result in loss of normal decay heat removal. Although alternate sources of cooling would be available via the ECCS, administrative measures will be taken to exclude lining of heavy loads over the operable RHR train piping in containment, except as follows. Specially controlled heavy load lias (i.e. reactor coolant pump motor, pump internals, etc.) may travel over supply piping for the only operable RHR train, so long as the RHR return piping is excluded from the liR area and provided an alternate ret supply / injection path is identified and available. Protection of the RHR return line will provide adequate tune for securing the operating RHR pump if cavitation were to occur due to line breaks in other containment locations. For a break in the supply piping of the only operable RHR train, identification of alternate RHR supply / injection flowpaths will allow for re-alignment of the operable RHR pump discharge piping to the RCS for maintenance of decay heat removal. Therefore, decay heat removal capability will be rmintained similar to that described above when both trains of RHR are operable.
Heavy load drops inside of the secondary shield walls could potentially impact RCS loop piping or a Class I branch line, including RHR system piping. If both trains of RHR are operable, the damaged train could be secured and the redundant train RHR would be available. For a rupture of the RHR supply line, check. valves inside the secondary shield wall will restrict alternate train flow through the break location unless the break occurs between the RCS piping and the check valve. For a rupture of the RHR return line, . l remote isolation of the break could occur via motor-operated valves inside the second ry i shield wall if the "B" train power supply is available and if the break occurs downstream of the isolation valves. Otherwise, RCS fluid would discharge to the containment floor and recirculation sumps. However, decay heat removal capability would still be available since '
the alternate RHR train would be started and force flow through the reactor vessel core (core barrel design routes inlet flow down the outside and up through the core before exiting the hot leg break location, and cold leg break location is above the top of the RCS loop piping). RHR suction would be aligned to the RWST or recirculation sump via off-1 sw
F .., ,
Attichment I to ULNRC-4056 Page 4 of 6 I i r.ormal plant procedures to provide long-term cooling. If only one train of RHR is j
. operable, and in operation, a rupture ofits associated supply or return line could result in X
loss of normal decay heat removal. Although alternate sources of cooling would be available via the ECCS, ' administrative measures will be taken to exclude lining of heavy loads over the operable RHR train piping in containment, except for specially controlled loads as described above for load drop evaluation outside of the secondary shield walls.
- Therefore, decay heat removal capability will be maintained similar to that described above l when both trains ofRHR are operable.
In summary, a postulated heavy load drop onto RHR' supply or return piping inside containment, and with a single train of RHR operable, could cause the loss of normal decay heat removal. Alternate lineups and core cooling sources would be available to l maintain decay heat removal. However, administrative measures will be taken to exclude L liRing of heavy loads over the operable RHR train piping in containment, except as i described above.
i l
During reduced inventory con 6 pas (RCS water level less than 3 feet below the reactor vessel flange), heavy load lifts u t r RHR piping in containment will be allowed only when both RHR trains are operable and a single RHR train is in service. This will ensure that both RHR pumps do not fait due to cavitation during a rapid drain down of the RCS.
Since both trains of RHR will be operable during reduced inventory conditions, one train l will always be available to supply decay heat removal once its suction source has been re-
- aligned. l l
Each reactor coolant pump motor and pump internals assembly will be replaced during the life of the
! plant. The replacement of a pump motor or pump internals assembly will also require removal, storage and re-installation of the concrete access hatch covers over the associated pump. These lias will involve weights that are much more significant than the typical refueling loads (excluding the reactor vessel head) moved around containment. Heavy load lifts of this nature will be carefully planned and executed, since a drop from the maximum lift height required could cause a significant impact on the RCS components and RHR piping below the operating floor level. Although the consequences of a load drop for any of these heavy load lifts are bounded by the analyses in the preceding paragraphs, lighter loads which are typically lifted in containment are more likely to be stopped by intervening floor and/or wall structures if dropped. In all cases, decay heat removal capability will be maintained.
Polar Crane During Refueling - During refueling, the polar crane is utilized to remove the reactor vessel head. Refer to Section 2.3 above. Should a heavy load drop impact an operating RHR line, RCS loop piping or other Class I branch line, the effects would be no more severe than the cases discussed above for the cold shutdown mode.
For the same reasons described above for the cold shutdown mode, lifting of heavy loads i over the operable RHR train piping in containment, when only one train is operable, will be prevented by administrative procedure except for the specially controlled lifts i oreviously described. Likewise, during reduced inventory conditions, heavy load liRs over
- JIR piping in containment will be allowed only when both RHR trains are oper61e and a 1
._ j
p
, Attachmtnt I to ULNRC-4056 Page 5 of 6 previously described. Likewise, during reduced inventory conditions, heavy load lifts over RHR piping in containment will be allowed only when both RHR trains are operable and a single RHR train is in service. Since both trains cf RHR will be operable during reduced inventory conditions, one train will always be available to supply decay heat removal once its suction source has been re-aligned.
Pajar Crane During Hot Standby and Hot Shutdown - The polar crane will be used during
. Int standby and hot shutdown (Modes 3 and 4) to minimize critical path outage times for cold shutdowns and refuelings, and to assist with maintenance that can be performed in a hot plant condition. Planned usage includes activities such as crane inspections, operability checks, and movement of tools and equipment required for the cold shutdown / refueling outage. It is anticipated that most lifts during Modes 3 and 4 will be oflight loads and will allow unrestricted movement.
The lining of heavy loads during Modes 3 and 4 is expected to be infrequent. The significance of the operation and the importance of proper rigging and restricted load movement will be stressed to those involved with heavy load lias. Both the main and auxiliary hooks are provided with independent and redundant limit switches which precluded the possibility of a two-blocking event. Minimum practical lift heights will be used throughout the load movement process, Certain anticipated heavy load movements have been analyzed, and restricted areas and safe load paths have been defined. These include but are not limited to the hydrogen mixing fans, excess letdown exchanger and reactor coolant drain tank heat exchanger hatches. However, all specific loads and load paths cannot be dermed. For these cases, safe load path considerations will be based on comparin with analyzed cases, previcusly defined safe movement areas, and previously defined restricted areas. For example, since integrity of the primary side pressure boundary is important during Modes 3 and 4, the area inside the secondary shield wall will .
be avoided if practical. In addition, when in Mode 4, if only one train of RHR is operable, the movement of any heavy load over that operable RHR train piping will be prohibited unless previously evaluated.
During Modes 3 and 4, containment integrity will be maintained in accordance with plant Technical Specifications, which allow various combinations of RCS loops and ECCS/RHR trains to be operable. A breach of either the primary or secondary side pressure boundaries will not result in radioactivity releases that are a significant portion of 10 CFR 100 limits. The time of use of the polar crane during these modes is a small percentage of total plant operation time. The time for lifting heavy loads is a still smaller percentage.
Postulated load dropa would result in consequences that are economic rather than public safety concerns. Therefore, the relative small risk involved, coupled with load path considerations and procedures and training, justifies the use of the polar crane during Modes 3 and 4.
Containment Jib Cranes (HKF03 A-D) Duing all Modes - The containment jib cranes (3-ton capacity) are utilized to remove the hydrogen mixing fans from their bottom skirts.
The hydrogen mixing fans are located directly above the reactor coolent pumps on slabs
C
, Attachment I to ULNRC-4056 Page 6 of 6 which are removable for access to the reactor coolant pumps. An analysis has been performed to ensure that the removable slabs would not fail. Refer to Appendix A for the worst-case analysis. Jib crane use for the fan or any other load within thejib crane capacity would be enveloped by the preceding discussion for use of the polar crane.
The removable slabs which support the hydrogen mixing fans can only be removed by the polar crane during Modes 5 and 6 under conditions previously discussed in this section.
The consequences of a drop of any of the slabs are enveloped by the preceding discussions ofpolar crane use during cold shutdown.
Secondary Shield Wall Area Jib Crane (HKF05) During Cold Shutdown And Refueling-Thejib crane (3-ton capacity) located near the pressurizer will be used during cold shutdown and refueling to handle components located in the pressurizer compartments.
The discussions of cold shutdown operation of the polar crane are also applicable to this jib crane. Rupturing of the reactor coolant pressure boundary at the pressurizer during cold shutdown would be no more severe than potential ruptures caused by polar crane drops. Core cooling would not be interrupted. During refueling, the water level of the reactor coolant system is below the pressurizer normal level, and there would be no effect on decay heat removal should a drop breach the pressurizer boundary.
Containment Equipment Hatch Hoist (HKF04A AND B) During Cold Shutdown - The equipment hatch hoist is used to handle the equipment hatch during Modes 5 and 6. A drop of the hatch will not affect safe shutdown or decay heat removal. As required by the technical specifications, the equipment hatch must be secured in place during fuel movement or core alterations.
Containment Building Elevator Auxiliary Monorail and Hoist (HKF31)- This monorail and hoist is shown on Figure 3 between approximately azimuths of 32 and 42 degrees, at Elevation 2023. It may be used during all modes to handle miscellaneous equipment which, if dropped, would not affect safe shutdown or decay heat removal.
I l
p
|
---|
|
|
| | Reporting criterion |
---|
05000483/LER-1998-001, Forwards LER 98-001-01,being Submitted to Clarify Scope of Original Reviews Performed for Corrective Action Number 3 in LER 98-001-00.Reviews Have Identified Case of Failure to Properly Establish Equipment Operability | Forwards LER 98-001-01,being Submitted to Clarify Scope of Original Reviews Performed for Corrective Action Number 3 in LER 98-001-00.Reviews Have Identified Case of Failure to Properly Establish Equipment Operability | | 05000483/LER-1998-003, Forwards LER 98-003-01 Re Inadvertent Actuation of ESFAS Due to 'A' SG High Level During Refuel 9.Rept Is Submitted to Report Change in C/A from That Reported in Original Rept | Forwards LER 98-003-01 Re Inadvertent Actuation of ESFAS Due to 'A' SG High Level During Refuel 9.Rept Is Submitted to Report Change in C/A from That Reported in Original Rept | | 05000483/LER-1998-008, Forwards Amended Response to GL 81-07, Control of Heavy Loads, to Address Corrective Action Described in LER 98-008-00.Discrepancy Between Earlier Submittals of Snupps Rept on Control of Heavy Loads & TS Re RHR Sys,Resolved | Forwards Amended Response to GL 81-07, Control of Heavy Loads, to Address Corrective Action Described in LER 98-008-00.Discrepancy Between Earlier Submittals of Snupps Rept on Control of Heavy Loads & TS Re RHR Sys,Resolved | |
|