ML20106A151
| ML20106A151 | |
| Person / Time | |
|---|---|
| Site: | 05000000, Satsop |
| Issue date: | 11/25/1983 |
| From: | Slemmons D SLEMMONS, D.B. |
| To: | Rolonda Jackson Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML20105B554 | List: |
| References | |
| FOIA-84-462 NUDOCS 8407180059 | |
| Download: ML20106A151 (5) | |
Text
3; s....
L DAvrobURTON SLEMMONS CONetJLTING 08014088T 7
9996 OOLDEN VALLEY ROAD RENO. NEVADA 80806 mm November 25,1983 Dr. Robert E. Jackson, Chief Geosciences Branch Division of Engineering U. S. Nuclear Regulatory Commission Washington, D.C. 20555
Dear Dr. Jackson:
This letter responds to your request that I prepare a preliminary and independent assessment of fault capability and maximum earth-quake parameters for the Washington Public Power Supply System's Nuclear Power Project No.
3, near Gatsop, Washington.
My review of the local and regional relations that affect seismic design at the site includes local and regional study of reports, responses to questions, and the relevant geological, seismological and geophysical data.
r If you require further information, please request additional comments by letter or telephone.
Sincerely yours, ode. Ln.4 D. Burton Slemmons Consulting Geologist e
a
i
.c,..
4 y
/
m t
t.
f
._,m. :.:...
g,,.
1 INTRODUCTION
'" e
~
1.1 Purpose of Study
~
This report was' requested by Dr.
Robert
.E.
- Jackson, Chief, Geosciences Branch, Division of Engineering, U.
S.
Nuclear Regulatory Commission.
The statements and conclusions are preliminary comments that are based on a partly incomplete data base.
The appraisal of regional and site-specific geological, seismological and geophysical information are summarized and important remaining major issues are listed.
1.2 Scope of Work This report is based on a site visit and study of reports on the geological, seismological and geophysical information on the local and regional geology.
My previous work in the Pacific Northwest includes study of regional seismicity, evaluation of the 1872 Pacific Northwest earthquake, evaluation of data on active or capable faults, compilation of faults and lineaments from various scales of topographic maps and several types of imagery.
My investigations included the determinations of fault capability and earthquake parameters for the U.S.
Corps of Engineers at six dams along parts of the Columbia and Snake Rivers and for the U.S.
Nuclear Regulatory Commission in the Columbia Plateau at the U.S.
Nuclear Project No.
2, the Skagit/Hanford Nuclear Project, Units 1 and 2, and the BWIP high level waste repositories.
2 GE0 LOGICAL FEATURES The following are comments regarding the geological and tectonic setting for the site and surrounding region:
1.
None of the mapped and trenched faults at the site show any evidence for activity.
This is suggested by the unfaulted older soils and terraces, and the accordant ridgelines that are about 2 million years old.
I see no need for further active fault investigations at the site.
2.
The Olympic Mountains are the nearest major structure that may be active tectonically.
This is an area of slow uplift (Gable and Hatton, 1983).
The eastern periphery of the Olympic Mountains has at least one short segment with Holocene offsets (Carlson, 1979;
- Vilson, and others, 1979).
Similar appearing structures have capable faults along parts of their boundary zones or on radiating structures.
The tectonic deformation of the border zone of the Olympic Mountains should be assessed in relation to the effects on faults that are near the WNP-3 site.
One
- zone, that may be of this type, needs further evaluation.
This zone of possible Quaternary deformation, the Humptulips-Wynocchee-Melbourne
- zone, is discussed in the main text of this report.
This zone may extend about 12 km west of the site and 2
,s
(
V
.w
/
L.
.o
..g report.
This zone hay ~ extend about 12 km west of the site and needs to be investigated ^for structural continuity or noncontinu-
- ity, fault capability and seismogenic potential.
New
- imagery, remote sensing data and shoreline deformation needs to be evaluated for the site region and major geologic structures.
3 The Olympic lineament is mainly identified from its gravity gradients.
It is postulated to be a potential source of a
magnitude (Ms) 7-1 /2 shallow-focus crustal earthquake.
The closest approach of this lineament is 22 mi (35 km).
There is no evidence for activity along this zone, although the Pleistocene erosion and deposition could obscure evidence fer activity for faults with recurrence intervals of over about 11,000 years.
The latest worldwide data would suggest the following magnitudes for a 2/3 rupture length:
The assumed normal-slip mechanism, using the formulation of Slemmons (1982) the magnitude is:
Ms = 0.809 + 1 341 log 59,000 = 7 2 For,an assumed reverse-slip mechanism, using the formulation of Slemmons (1982) the magnitude is:
Me = 2.021 + 1.142 log 59,000 = 7 5 For an assumed normal-oblique-slip mechanism, using the formula-tion of Slemmons (1982) the magnitude is:
Ma = 0.875 + 1 348 los 59,000 = 7 3 For an assumed reverse-oblique-slip mechanism, usir.g the formula-tion of Slemmons (1982) the magnitude is:
Ms = 1.199 + 1.271 log 59,000 = 7 3 If the structure is a capable reverse-slip fault, or a normal-slip
- fault, the use of 2/3 rupture length may. require reevalua-tion, since the worldwide demonstration of fractional lengths for magnitude estimates is not documented, and the specific fraction has not been carefully assessed.
There is no specific data on the type of fault that may control the Olympic lineament.
The interrelationship of this feature with other faults of similar orientation toward the southeast requires more detailed investi-gations for possibic capability and tectonic connection to the Dalles area (U.S.
Army Corps of Engineers, 1982) or to Mt.
St.
Helens (Carlson, 1979; Wilson and others, 1979).
In addition, this feature has not been assessed for relationship to regional stress axes or possible conjugate relationships.
Several questions remain unresolved; these include:
Is this a capable fault?
- What, if
- any, are the interconnections to the southeast?
3
.3
,k s
h*
~
6.
.....Z l...
,...... g
.g
... ~ _
What is the probable type of fault shown by direct or conjugate relationships?
The data for estimating the magnitude, taken from Slemmons (1977 and 1962), give Ms magnitudes that are somewhat 6reater than 7 3, but answers to the above qu'estions are more important issues.
3 SEISM 0 LOGICAL SETTING 3.1 General Statement The WNP-3 site appears to be in a tectonically stable region for shallow focus earthquakesas as is shown by the historical record of seismicity and the record of known active or capable faults of the region.
- However, the cross section of the site seismicity and the evidence cited by Heaton and Kanamori (1983) suggest that subduction in the northwestern part of United S ates is seismic that a great earthquake could occur in this regicn.
Two possible maximum earthquakes should be considered for this site, shallow focus and deeper Benioff or subduction zone earthquakes.
32 Shallow Focus Earthquakes The number of shallow focus earthquakes is relatively low L
the site area and no capable faults are defined by current seismic-ity.
Seismicity patterns do not resolve the issue of whether or not the Olympic lineament or structures near the Olympic Mountains are capable.
Focal mechanism studies are useful for defining the orientations of conjugate faults.
The limited data that is available for the site-area suggest that most of the faults are reverse-slip faults, although strike-slip components are common.
The activity at Mt.
St. Helens appears to be right-slip on a north-south fault zone (Weaver and Smith, 1981).
The seismologic evaluation of the site area should be reevaluated with the cross sections for narrower belts of seismicity, so that the vertical display of focal depths is more representative of local distributions.
33 Deeper' Shallow Focus Earthquakes The most critical single issue that needs to be resolved for the seismic design for the nuclear power generator is the question of whether or not the underlying Benioff zone or subduction plate boundary is seismogenic or aseismic.
The volcanic activity of the Cascade volcanoes, and the known motions between the North American and Juan de Fuca plates clearly show that there is subduction with a relative movement between the plates of from 2 to 4 cm/yr.
The seismological debate on whether or not this zone is seismic or aseismic has not been resolved and this
- issue, along with a
maximum earthquake magnitude
- value, if it is
- seismic, must be addressed on the basis of newer analyses that were present at the time of preparation of the FSAR.
4
4 l' tv M.
...g
. y.... 7..
,...m...
.i y.
John Adams (oral communi6ation, J1983) has suggested that geolog-ical studies could be made of both continental lacustrine and marine sediments to determine whether or not liquefaction and landslide. events are recorded at the base of bodies..of._ water.
Coring and dredging methods have shown the effects of paleoseis-mic activity.
This method may provide a geological measure of whether earthquakes occur in the northwestern United States or the movement between the plates is aseismic.
4 GEOPHYSICAL SETTING The geophysical studies of the region and for the site area are mostly
- adequate, but they should be reexamined to determine if any of the-geophysical (e.g.
intratelluric, seimic reflection
- profiles, etc.) methods can be expanded with new data to resolve the issue of whether or not the boundary between the North Ameri-can and Juan de Fuca plates is seismic or aseismic.
5 CONCLUSIONS 1.
The most important single issue is the question of whether or not the Benioff zone beneath the site is capable of a
large earthquake that should be considered in the design at WNP-3 This issue has not been resolved.
2.
Two possible shallower focus earthquakes may need to be considered for seismic design at WNP-3 The seismic motion at the site may have a different spectral content and the distance to the site may be closer than for.1, above.
This should include a reassessmentoof the Olympic lineament, to determine if it is a capable
- fault, and to examine structures around and near the Olympic Mountains to determine capability.
The latter should include an evaluation of the Hamptulips-Wynocchee-Melbourne zone.
3 Site faults are older, inactive faults that show no. evidence for current activity.
The old upland surfaces with their accordant ridgelines show no evidence for faults with vertical components of displacement during the past 2 or 3 million years.
Subsurface exploration at the site does not appear to be warranted.
The most important single issue is the question of whether or not the Benioff zone beneath the site is' capable of an earthquake that should be considered in the design of vital structures at the Satsop site.
I believe that until this issue is resolved, no specific earthquake magnitudes should be estimated for this type of earthquake.
5 a%