Forwards Program Description Re Reduction of Leakage from Sys Outside Containment That Would or Could Contain Highly Radioactive Fluids in post-accident Situation for Resolution of SER Confirmatory Issue B.28/III.D.1.1 (NUREG-0881)
ML20087N191
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 03/30/1984
From: Koester G
KANSAS GAS & ELECTRIC CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0881, RTR-NUREG-881, TASK-3.D.1.1, TASK-TM KMLNRC-84-046, KMLNRC-84-46, NUDOCS 8404030201
Download: ML20087N191 (4)


Text

KANSAS GAS AND ELECTRIC COMPANY THE ELECTAC COMPANY GLENN L MOESTER WCE PRESIDENT huCLEAR March 30, 1984 o

Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 KMLNRC 84-046 Re: Docket No. STN 50-482 Ref: NUREG-0881, Wolf Creek Safety Evaluation Report Subj: Confirmatory Issue B.28 (III.D.l.1)

Dear Mr. Dentons The Referenced document identified Confirmatory Item B.28/

III.D.l.1 (Integrity of Systems Outside Containment Likely to Contain Radioactive Material) which required additional information concerning a program to reduce leakage from systems outside containment that would or could contain highly radioactive fluids in a post-accident situation.

Transmitted herewith is a description of the program needed to resolve this issue. This information is hereby incorporated into the Wolf Creek Generating Station, Unit No.1, Operating License Application.

Yours very truly, h g M GLK:bb Attach cc: PO 'Connor ( 2)

WSchum 8404030201 840330 @

PDR ADOCK 05000482 E PDR  !

{

201 N. Market -Wictuta, Kansas - Mail Addr0ss:RO. 9:+. 208 I Wichita, Kansas 67201 - Telephone: Area Code (316) 261-6451

e OATH OF AFFIRMATION STATE OF KANSAS )

) SS:

, COUNTY OF SEDGWICK )

I, Glenn -L. Koester, of lawful age, being duly sworn upon oath, do depose, state and affim that I am Vice President - Nuclear of Kansas Gas and Electric Company, Wichita, Kansas, that I have signed the foregoing letter of transmittal, know the contents thereof, and that all statements contained therein are true.

KANSAS GAS AND ELECTRIC COMPANY ATTEST: ,. f .

'Glenn L.~ Kocstie'r Vice President - Nuclear E.D. Prothro, Assistant Secretary .

STATE OF KANSAS )

) SS:

COUNTY OF SEDGWICK )

BE IT REMEMBERED that on this 30th day of March. 1984 , before me, Evelyn L. Fry, a Notary, personally appeared Glenn L. Koester, Vice President - Nuclear of Kansas Gas and Electric Company, Wichita, Kansas, who is personally known to me and who executed the foregoing instrument, and he duly acknowledged the execution of the same for and on behalf of j and as the act and deed of said corporation.

IN WITNESS WHEREOF, I have hereunto set my hand and affixed my seal the

,,and year above written.

jry *

  • kVV', .f)..,

f fl'

,p l 'Y i ',>rij}n felyn [ Fry, Nota h

.: s  :' e,;

" : .T . *

" ? g Mf'. Commission expires on August 15, 1984.

1 s

.i n

  • WOLF CREEK GENERATING STATION

. PRIMARY COOLANT SOURCES OUTSIDE CONTAINMENT This-defines Kansas Gas and Electric's program to reduce leakage from those portions of systems outside containment that could contain

- highly radioactive fluids during a. serious transient or accident to as low as practical levels. This program is in support of NUREGs 0737,_0881, and 0830 and will fulfill the requirements of the Wolf Creek- Generating Station FSAR and Technical Specifications. .The systems considered include the recirculation portion of the Contain-i ment Spray- System, Safety Injection -System, Chemical and Volume Control System, Residual Heat Removal System c,d Nuclear Sampling System (PASS only). The program is as follows:

1. General ~ Practical Leak Reduction Measures The Operations Department will develop procedures which will govern the monitoring of specific systems to main-tain as low a leak rate as practical, and make periodic inspections of affected systems.

Maintenance as directed by W' o rk Requests, will perform repair / rework on all components as needed to correct leaks _ as they are detected.

2. Periodic Visual Inspection In' accordance with Wolf Creek Generating Station (WCGS)

Administrative - Procedures, the Operations Department is -

tasked with the responsibility of _ inspecting all the -

recirculation portions of the containment Spray System, Safety Injection System, Chemical and Volume Control System, Residual Heat' Removal System and Nuclear Sampling System (PASS'only) outside of containment. -Operation's Personnel will inspect the above named systems including vent valves, drain valves, relief-valves, sample valves and. flushing valves, as well as the in-line . valves, piping and pumps. The Operations Department will 'make this inspection prior to initial f uel load and once between each refueling. Leak rates will be determined and leaks reduced to as low a level as practical. Work requests will be generated by the Operations Department for maintenance / repair / rework to correct leaks as they are found. A one-time-report will. be submitted to the NRC prior to initial fuel load.

In addition, .the normal duties and responsibilities of the Operations Department as described in WCGS ADM 02-010 will include walkdown and visual inspection of accessible systems. Identification and correction of leakage is one of the criteria specified for these walkdowns.

WCGS Primary Coolant Sources Outside Containment Page 2 Housekeeping is also carried out by a WCGS Administrative

' Procedure 01-034 which requires a daily walkdown to check for cleanliness, leaks and spills. WCGS Administrative Procedure 01-034, Paragraph 6.1.3 directs that any spills be promptly contr olled and cleaned up. WCGS ADM 03-852 Paragraph 6.2 provides the guidelines for radioactive -

spills.

3 Additional Programs Resulting in Detection and Redaction of Leakage WCGS has an established Managed Maintenance Program which is documented by WCGS ADM 08-202. This progran includes generic preventive maintenance activities based on experience, engineering judgement, inspection , testing and replacement of items which have a specific lifetime such as weer rings, bearings, seals and packing.

WCGS is also committed to ASME Section XI Inservice Inspection Program using the ASME Code 1980 and winter 1981 Addition.