Forwards Changes to Wolf Creek Generating Station Data Point Library.Emergency Response Data Sys Points Affected Are EJL0007 & EJL0008
ML20211M715
Person / Time
Site: Wolf Creek 
Issue date: 09/03/1999
From: Muench R
WOLF CREEK NUCLEAR OPERATING CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
ET-99-0038, NUDOCS 9909090186
Download: ML20211M715 (3)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

l

,a W6) NUCLEAR OPERATING C LF CREEK Richard A Muench vic. pr..w.ni engin ri"'

W 3 1999 ET 99-0038 U. S. Nuclear Regulatory Commission ATTN:

Document Control Desk Mail Station Pl-137 Washington, D. C.

20555

Subject:

Docket No. 50-482:

Changes to Wolf Creek Generating Station Radiological Emergency Response Data System Data Point Library Gentlemen:

Gentlemen':

In accordance with 10CFR50 Appendix E. VI.

3.a., this letter transmits changes to Wolf Creek Generating Station's (WCGS) Data Point Library (DPL).

The minimum instrument range for the containment recirculation was lowered by two percent in order to prevent the point from false alarming on the dynamic alarm display in the control room.

In addition, an editorial change was made to the zero point referenced for the containment sumps to indicate the use of the site elevation.

The Emergency Response Data System points affected are EJL0007 and EJL0008.

The changes are being transmitted as replacement pages to update the WCGS DPL.

These changes were implemented August 4, 1999.

If ycu have any questions concerning this matter, please contact me at (316) 364-4034, or Mr. Michael J. Angus at (316) 364-4077.

Very truly yours, 1

2 Nw O

Richard A. Muench

^^"2" a90023 l'

Attachment cc:

J. N. Donohew (NRC), w/a W. D. Johnson (NRC), w/a E. W. Merschoff (NRC), w/a Senior Resident Inspector (NRC), w/a 7909590186 990903 y

PDR ADOCK 05000482

- 0 F

PDR P.O. Box 411/ Burlington, KS 66839 / Phone: (316) 364 8831 l

An Equal Opporturury Employer M F HCVET l

m

Attachment to ET 99-0038 Page 1 of 2 ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8) 08/04/99 Reactor Unit: (3)

WC1 Data Feeder: (10)

N/A NRC ERDS Parameter: (12)

CTMNT SMP WR Point iD: (12)

EJL0007

)

Plant Spec Point Desc.: (40)

CTMT RECIRC SUMP A LEVEL l

l Generic /Cond Desc.: (32)

CTMT EMERGENCY RECIRC SUMP Analog / Digital: (1)

A l

Engr Units / Dig States: (12)

ELEV Engr Units Conversion: (40)

N/A Minimum Instr Range: (10) 1992.84 l

Maximum Instr Range: (10) 2006.1 Zero Point

Reference:

(6) 1993.10 Reference Point Notes: (40)

RELATIVE SITE ELEVATION t

l PROC or SENS: (1)

S i

Number of Sensors: (3) 1 l

How Processed: (40)

N/A l

Sensor Locations: (40)

INSIDE CTMT AT RECIRC SUMP A l

Alarm / Trip Set Points: (40)

N/A l

' NI Detector Power Supply Cut-off Power Level: (15)

N/A i

NI Detector Power Supply Turn-on Power Level: (15)

N/A instrument Failure Mode: (30)

LOW = LOP Temperature Compensation for l

DP Transmitters: (1)

N/A I

l Level Reference Leg: (3)

N/A Unique System Desc.: (100)

RECIRC SUMP LEVEL XMTR TRAIN A EJLIT0007 ZERO PT REF 5.5" ABV SUMP FLOOR l

l COMPUTER ALARMS MODE HI HC 2002.2 1

RF 2002.2 l

r-q l

Attachment to ET 99-0038 l

Page 2 of 2 I

ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8) 08/04/99 Reactor Unit: (3)

WC1 1

Data Feeder: (10)

N/A NRC ERDS Parameter: (12)

CTMNT SMP NR Point ID: (12)

EJL0008 Plant Spec Point Desc.: (40)

CTMT RECIRC SUMP B LEVEL Generic /Cond Desc.: (32)

CTMT EMERGENCY RECIRC SUMP Analog / Digital: (1)

A Engr Units / Dig States: (12)

ELEV Engr Units Ccaversion: (40)

N/A Minimum instr Range: (10) 1992.84 l

Maximum instr Range: (10) 2006.10 Zero Point

Reference:

(6) 1993.10 Reference Point Notes: (40)

RELATIVE SITE ELEVATION PROC or SENS: (1)

S Number of Sensors: (3) 1 How Processed: (40)

N/A Sensor Locations: (40)

INSIDE CTMT AT RECIRC SUMP B Alarm / Trip Set Points: (40)

N/A NI Detector Power Supply Cut-off Power Level: (15)

N/A NI Detector Power Supply Turn-on Power Level: (15)

N/A instrument Failure Mode: (30)

LOW = LOP Temperature Compensation for DP Transmitters: (1)

N/A Level Reference Leg: (3)

N/A Unique System Desc.: (100)

RECIRC SUMP LEVEL XMTR XMTR TRAIN B EJLIT0008 ZERO PT REF 5.5" ABV SUMP FLOOR l

COMPUTER ALARMS MODE Hi HC 2002.20 RF 2002.20 I