MONTHYEARML20217G7951999-09-30030 September 1999 Monthly Operating Repts for Sept 1999 for McGuire Nuclear Station,Units 1 & 2 ML20217G8101999-08-31031 August 1999 Revised Monthly Operating Repts for Aug 1999 for McGuire Nuclear Station,Unit 1 & 2 ML20216E8851999-08-31031 August 1999 Monthly Operating Repts for Aug 1999 for McGuire Nuclear Station,Units 1 & 2 ML20210S2371999-07-31031 July 1999 Monthly Operating Repts for July 1999 for McGuire Nuclear Station,Units 1 & 2 ML20216E8951999-07-31031 July 1999 Revised Monthly Operating Repts for July 1999 for McGuire Nuclear Station,Units 1 & 2 ML20210S2491999-06-30030 June 1999 Revised Monthly Operating Rept for June 1999 for McGuire Nuclear Station,Units 1 & 2 ML20209H1631999-06-30030 June 1999 Monthly Operating Repts for June 1999 for McGuire Nuclear Station,Units 1 & 2 ML20195K3691999-05-31031 May 1999 Monthly Operating Repts for May 1999 for McGuire Nuclear Station,Units 1 & 2 ML20209H1731999-05-31031 May 1999 Revised Monthly Operating Rept for May 1999 for McGuire Nuclear Station,Units 1 & 2 ML20195K3761999-04-30030 April 1999 Revised MORs for Apr 1999 for McGuire Nuclear Station,Units 1 & 2 ML20206R0891999-04-30030 April 1999 Monthly Operating Repts for Apr 1999 for McGuire Nuclear Station,Units 1 & 2 ML20205P8991999-03-31031 March 1999 Monthly Operating Repts for Mar 1999 for McGuire Nuclear Station,Units 1 & 2 ML20206R0931999-03-31031 March 1999 Revised Monthly Repts for Mar 1999 for McGuire Nuclear Station,Units 1 & 2 ML20205P9021999-02-28028 February 1999 Revised Monthly Operating Repts for Feb 1999 for McGuire Nuclear Station,Units 1 & 2 ML20204C8911999-02-28028 February 1999 Monthly Operating Repts for Feb 1999 for McGuire Nuclear Station,Units 1 & 2 ML20204C8961999-01-31031 January 1999 Revised Monthly Operating Repts for Jan 1999 for McGuire Nuclear Station,Units 1 & 2 ML20199E0301998-12-31031 December 1998 Monthly Operating Repts for Dec 1998 for McGuire Nuclear Station,Units 1 & 2 ML20198D7561998-11-30030 November 1998 Monthly Operating Repts for Nov 1998 for McGuire Nuclear Station,Units 1 & 2 ML20199E0491998-11-30030 November 1998 Revised Monthly Operating Rept for Nov 1998 for McGuire Nuclear Station,Units 1 & 2 Re Personnel Exposure ML20198D7771998-10-31031 October 1998 Revised Monthly Operating Rept for Oct 1998 for McGuire Nuclear Station,Units 1 & 2 ML20195E5961998-10-31031 October 1998 Monthly Operating Repts for Oct 1998 for McGuire Nuclear Station,Units 1 & 2 ML20154L6251998-09-30030 September 1998 Monthly Operating Repts for Sept 1998 for McGuire Nuclear Station,Units 1 & 2 ML20195E6021998-09-30030 September 1998 Revised Monthly Operating Rept for Sept 1998 for McGuire Nuclear Station,Units 1 & 2 ML20154L6321998-08-31031 August 1998 Rev 1 to MOR for Aug 1998 for McGuire Nuclear Station,Unit 1 ML20153B3741998-08-31031 August 1998 Monthly Operating Repts for Aug 1998 for McGuire Nuclear Station,Units 1 & 2 ML20237B2381998-07-31031 July 1998 Monthly Operating Repts for July 1998 for McGuire Nuclear Station,Units 1 & 2 ML20153B3931998-07-31031 July 1998 Revised Monthly Operating Repts for Jul 1998 for McGuire Nuclear Station,Units 1 & 2 ML20237B2401998-06-30030 June 1998 Revised Monthly Operating Rept for June 1998 for McGuire Nuclear Station,Units 1 & 2 ML20236Q8201998-06-30030 June 1998 Monthly Operating Repts for June 1998 for McGuire Nuclear Station,Units 1 & 2 ML20236F0381998-05-31031 May 1998 Monthly Operating Repts for May 1998 for McGuire Nuclear Station,Units 1 & 2 ML20236Q8251998-05-31031 May 1998 Revised MOR for May 1998 for McGuire Nuclear Station,Units 1 & 2 ML20247K3851998-04-30030 April 1998 Narrative Summary Pages to Apr 1998 MOR for McGuire Nuclear Station ML20247L5981998-04-30030 April 1998 Monthly Operating Repts for Apr 1998 for McGuire Nuclear Station,Units 1 & 2 ML20217B0681998-03-31031 March 1998 Monthly Operating Repts for Mar 1998 for McGuire Nuclear Station,Units 1 & 2 ML20247L6181998-03-31031 March 1998 Revised Monthly Operating Rept for Mar 1998 for McGuire Nuclear Station,Units 1 & 2 ML20216E3991998-02-28028 February 1998 Monthly Operating Repts for Feb 1998 for McGuire Nuclear Station,Units 1 & 2 ML20217B0811998-02-28028 February 1998 Revised Monthly Operating Repts for Feb 1997 for McGuire Nuclear Station,Units 1 & 2 ML20202G7531998-01-31031 January 1998 Monthly Operating Repts for Jan 1998 for McGuire Nuclear Station,Units 1 & 2 ML20216E4111998-01-31031 January 1998 Rev 1 to Monthly Operating Repts for Jan 1998 for McGuire Nuclear Station,Units 1 & 2 ML20202G7741997-12-31031 December 1997 Revised Monthly Operating Repts for Dec 1997 for McGuire Nuclear Station,Units 1 & 2 ML20198P2521997-12-31031 December 1997 Monthly Operating Repts for Dec 1997 for McGuire Nuclear Station ML20203H6491997-11-30030 November 1997 Monthly Operating Repts for Nov 1997 for McGuire Nuclear Station,Units 1 & 2 ML20199D3221997-10-31031 October 1997 Monthly Operating Repts for Oct 1997 for McGuire Nuclear Station ML20203H6601997-10-31031 October 1997 Revised Monthly Operating Repts for Oct 1997 for McGuire Nuclear Station,Units 1 & 2 ML20211P9841997-09-30030 September 1997 Monthly Operating Repts for Sept 1997 for McGuire Nuclear Station ML20216K1301997-08-31031 August 1997 Monthly Operating Repts for Aug 1997 for McGuire Nuclear Station,Units 1 & 2 ML20216K1561997-07-31031 July 1997 Revised Monthly Operating Status Rept for Jul 1997 for McGuire Nuclear Station,Units 1 & 2 ML20210L0691997-07-31031 July 1997 Monthly Operating Repts for July 1997 for MNS ML20149F2421997-06-30030 June 1997 Monthly Operating Repts for June 1997 for McGuire Nuclear Station,Units 1 & 2 ML20140H1171997-05-31031 May 1997 Monthly Operating Repts for May 1997 for McGuire Nuclear Station,Units 1 & 2 1999-09-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217G7951999-09-30030 September 1999 Monthly Operating Repts for Sept 1999 for McGuire Nuclear Station,Units 1 & 2 ML20217F3661999-09-22022 September 1999 Rev 18 to McGuire Unit 1 Cycle 14 Colr ML20212D1911999-09-20020 September 1999 SER Accepting Exemption from Certain Requirements of 10CFR50,App A,General Design Criterion 57 Closed System Isolation Valves for McGuire Nuclear Station,Units 1 & 2 ML20216E8851999-08-31031 August 1999 Monthly Operating Repts for Aug 1999 for McGuire Nuclear Station,Units 1 & 2 ML20211B1281999-08-31031 August 1999 Dynamic Rod Worth Measurement Using Casmo/Simulate ML20217G8101999-08-31031 August 1999 Revised Monthly Operating Repts for Aug 1999 for McGuire Nuclear Station,Unit 1 & 2 ML20211G5261999-08-24024 August 1999 SER Accepting Approval of Second 10-year Interval Inservice Insp Program Plan Request for Relief 98-004 for Plant,Unit 1 ML20211F3441999-08-17017 August 1999 Updated non-proprietary Page 2-4 of TR DPC-NE-2009 ML20210S2371999-07-31031 July 1999 Monthly Operating Repts for July 1999 for McGuire Nuclear Station,Units 1 & 2 ML20216E8951999-07-31031 July 1999 Revised Monthly Operating Repts for July 1999 for McGuire Nuclear Station,Units 1 & 2 ML20209E4361999-07-0909 July 1999 SER Agreeing with Licensee General Interpretation of TS LCO 3.0.6,but Finds No Technical Basis or Guidance That Snubbers Could Be Treated as Exception to General Interpretation ML20196K6631999-07-0707 July 1999 Safety Evaluation Supporting Licensee 990520 Position Re Inoperable Snubbers ML20209H1631999-06-30030 June 1999 Monthly Operating Repts for June 1999 for McGuire Nuclear Station,Units 1 & 2 ML20210S2491999-06-30030 June 1999 Revised Monthly Operating Rept for June 1999 for McGuire Nuclear Station,Units 1 & 2 ML20209H1731999-05-31031 May 1999 Revised Monthly Operating Rept for May 1999 for McGuire Nuclear Station,Units 1 & 2 ML20206T4771999-05-31031 May 1999 Rev 3 to UFSAR Chapter 15 Sys Transient Analysis Methodology ML20196L1881999-05-31031 May 1999 Non-proprietary Rev 1 to DPC-NE-3004, Mass & Energy Release & Containment Response Methodology ML20195K3691999-05-31031 May 1999 Monthly Operating Repts for May 1999 for McGuire Nuclear Station,Units 1 & 2 ML20206N3511999-05-11011 May 1999 Safety Evaluation Accepting Licensee Response to GL 96-05, Periodic Verification of Design-Basis Capability of Safety- Related Movs ML20195K3761999-04-30030 April 1999 Revised MORs for Apr 1999 for McGuire Nuclear Station,Units 1 & 2 ML20206R0891999-04-30030 April 1999 Monthly Operating Repts for Apr 1999 for McGuire Nuclear Station,Units 1 & 2 ML20205L2341999-04-0505 April 1999 SFP Criticality Analysis ML20206R0931999-03-31031 March 1999 Revised Monthly Repts for Mar 1999 for McGuire Nuclear Station,Units 1 & 2 ML20205P8991999-03-31031 March 1999 Monthly Operating Repts for Mar 1999 for McGuire Nuclear Station,Units 1 & 2 ML20205C4171999-03-25025 March 1999 Special Rept 99-02:on 801027,Commission Approved for publication,10CFR50.48 & 10CFR50 App R Delineating Certain Fire Protection Provisions for Nuclear Power Plants Licensed to Operate Prior to 790101.Team Draft Findings Reviewed ML20207K2051999-03-0505 March 1999 Special Rept 99-01:on 990128,DG Tripped After 2 H of Operation During Loaded Operation for Monthly Test.Caused by Several Components That Were Degraded or Had Intermittent Problems.Parts Were Replaced & Initial Run Was Performed ML20204C8911999-02-28028 February 1999 Monthly Operating Repts for Feb 1999 for McGuire Nuclear Station,Units 1 & 2 ML20205P9021999-02-28028 February 1999 Revised Monthly Operating Repts for Feb 1999 for McGuire Nuclear Station,Units 1 & 2 ML20204C8961999-01-31031 January 1999 Revised Monthly Operating Repts for Jan 1999 for McGuire Nuclear Station,Units 1 & 2 ML20199E0301998-12-31031 December 1998 Monthly Operating Repts for Dec 1998 for McGuire Nuclear Station,Units 1 & 2 ML20216F9931998-12-31031 December 1998 Piedmont Municipal Power Agency 1998 Annual Rept ML20198A4481998-12-11011 December 1998 Safety Evaluation Concluding That for Relief Request 97-004, Parts 1 & 2,ASME Code Exam Requirements Are Impractical. Request for Relief & Alternative Imposed,Granted ML20198D7561998-11-30030 November 1998 Monthly Operating Repts for Nov 1998 for McGuire Nuclear Station,Units 1 & 2 ML20199E0491998-11-30030 November 1998 Revised Monthly Operating Rept for Nov 1998 for McGuire Nuclear Station,Units 1 & 2 Re Personnel Exposure ML20199E9651998-11-24024 November 1998 Rev 1 to ATI-98-012-T005, DPC Evaluation of McGuire Unit 1 Surveillance Weld Data Credibility ML20196D4171998-11-24024 November 1998 Special Rept 98-02:on 981112,failure to Implement Fire Watches in Rooms Containing Inoperable Fire Barrier Penetrations,Was Determined.Repair of Affected Fire Barriers in Progress ML20196G0581998-11-0606 November 1998 Rev 17 to COLR Cycle 13 for McGuire Unit 1 ML20196G0761998-11-0606 November 1998 Rev 15 to COLR Cycle 12 for McGuire Unit 2 ML20198D7771998-10-31031 October 1998 Revised Monthly Operating Rept for Oct 1998 for McGuire Nuclear Station,Units 1 & 2 ML20195E5961998-10-31031 October 1998 Monthly Operating Repts for Oct 1998 for McGuire Nuclear Station,Units 1 & 2 ML20154L6251998-09-30030 September 1998 Monthly Operating Repts for Sept 1998 for McGuire Nuclear Station,Units 1 & 2 ML20195E6021998-09-30030 September 1998 Revised Monthly Operating Rept for Sept 1998 for McGuire Nuclear Station,Units 1 & 2 ML20154B4131998-09-22022 September 1998 Rev 0 to ISI Rept for McGuire Nuclear Unit 1 Twelfth Refueling Outage ML20151W3521998-09-0808 September 1998 Special Rept 98-01:on 980819,maint Could Not Be Performed on FPS Due to Isolation Boundary Leakage.Caused by Inadequate Info Provided in Fire Impairment Plan.Isolated Portion of FPS Was Returned to Svc ML20154L6321998-08-31031 August 1998 Rev 1 to MOR for Aug 1998 for McGuire Nuclear Station,Unit 1 ML20153B3741998-08-31031 August 1998 Monthly Operating Repts for Aug 1998 for McGuire Nuclear Station,Units 1 & 2 ML20236U1601998-07-31031 July 1998 Non-proprietary DPC-NE-2009, DPC W Fuel Transition Rept ML20237B2381998-07-31031 July 1998 Monthly Operating Repts for July 1998 for McGuire Nuclear Station,Units 1 & 2 ML20153B3931998-07-31031 July 1998 Revised Monthly Operating Repts for Jul 1998 for McGuire Nuclear Station,Units 1 & 2 ML20236P0451998-07-0808 July 1998 Part 21 Rept Re non-conformance & Potential Defect in Component of Nordberg Model FS1316HSC Standby Dg.Caused by Outer Spring Valves Mfg from Matl That Did Not Meet Specifications.Will Furnish Written Rept within 60 Days 1999-09-30
[Table view] |
Text
_~ _- . . . - . - - - - -
a OTEFATINS IATA FIFORT 003fi WD _ 50-369 IATE9ttoter 15. 1991 0FEF4 TING STATUS COMPLEitD H l'A.W11111ti_
IILEPH0KE 7M 373 5987
- 1. Unit Nase: McGalte 1
- 2. fearting ferlot Septeater 1,1991 $epteober 30.1991 l
- 3. Licensed theras! Net (Uth 3411 '
- 4. Naseplate Rating (Bross Ne): 13058 Notes aNameplate Fating 5.DesignElettrica4 Rating (Net N e h 1100 16tess Mel calculated as !
- 6. Marious tependable Capacity 16 test N els 1171 1450.000 MA e .9) pcuer
- 7. Maxieus Depen;able Co acity (Net M e):
1129 factorperFageill, i B. If Char.ges Octur in Capacity Ratings (Iteas Nesber 3 Thrcugh 7) Sinte last N'JFEG-0020. 4 Report. Give Reason: ,
- 9. Pcmer Level To 6ibich Restricted, if Any (Net Meh 10.' Feason for Restrictiens, if any: .
This Mor.th Yr.-te-Date Ceeutettie .
!!. fleurs In Reporting ferted . 720.0 6551.0 86103.0
- 12. hur.ber Of knts Reactor Was Critical 463.0 5767.2 61433.1 -
- 13. Peacter Feservs Shutocan Hours --0-- --0-- - 0~
- 14. k rs Generatsr De-Lirie 412.6 5751.7 -607't.B
- 15. l) nit Resene Shutdown Hours - --0~ --0--
- 16. Ettas Thersal Energy Grt.erated (m) 1557266 19183999 185419561
- 17. Gross Electrical Energy Generated I M ) 525977 6605156 63827591 19 Net Electrical' Energy Benerated ( M ) 501910 6546104 60934292
- 19. Unit Service facter 64.3 67.9 70.5 20.UnitAvailabilityfactor 64.3 B7.8 - 70.5 21.~trlf Capacity factor (Using hDC het) 61.7 65.9 el.2
- 22. Unit Capacity fatter (Using PER Net) 59.1 32.1 59.9
- 23. Unit . Forced Cutage Rate 0.0 - B.6 12.5 124. Shutdown Scteduled Over Next 6 Menths (Type, Date, and Duration of f acM:
Currently Refueling -
25 -If Stut bn it End Of Peport Feriod. Estisated Date of Startup: November 29 7 91 .
- 26. Unitt in Test Status (Fript to Centercial Operatien)
- Forecast Achieved INITI AL CR111CRiiY j
Ih!TIALELECTRICliy j~ CO*aERCIAL CPERA110N b ;
i
~ 9110180231 91t015 9 PDR ftDOCK 0500 R-
e o .
, i DPERA11NG DATA FEFORI l I
4 DDCt[i ND 50-369 :
UNil Mc691re 1
- DATE Otteter 15. 1991 COMPLETEDBY R.Adilllees >
, TELifHONE 704 373 5997 i
MONfit Statenter. 1991 i
- (ii. .AVEEAGE DAILY F0eIR LEVEL M AVERAGE DAILY F0WER LEVEL (MWe-het) (Mwe-Net)
-! 1096 17 1110 2 1096 1B 1093 3- 1097 19 1661 3 4 _ _ _ --1100 20 54 i
5 1103 El 0 6 1100 22 ,
0 7 1098 23 0 ,
6- 1099 24 0 ,
.i
'9: 1114 25 0 10 1122 26 0~
i 11 112? 27 0 12 _
1120 2B 0 o
13 1120 29 0 14 !!!9 30 0 +
15 1117
~
16 1114
UNIT SHUTDOWNS AND POWER REDUCT2ONS DOCKET NO. 50-369 .
UNIT NAME Mwuixt 1 DATE A uf ruf s t REPORT MONTH September 1991 COMPLETED BY b. w. nudtx .
TELEPHONE t / v4 } -> e a-> / <>2 (1) 2) _
(4) (5) i E HOD T A OF LICENSE N Y S SHUT EVENT SYS- CAUSE AND COPJIECTIVE O P DURATION O DOWN REPORT TEM COMPONENT ACTION TO
. DATE E HOURS N R/X NO. CODE CODE PREVENT RECURRENCE S 91- 9-20 S 257.43 C 1 RC FUELXX END-OF-CYCLE '7' REFUELING OUTAGE i
(1) (2) (3) (4)
F Forced Reason- Method: Exhibit G - Instructions S Scheduled A-Equi ment Failure (Explain) 1-Manual for Preparation of, Data B-Main enance or test 2-Manual Scram Entry Sheets For Licensee C-Refueling 3-Automatic Scram Event Report (LER D-Regulatory Restriction , ,
4-Other (Explain) File (NUREG-Ol61))
- E-Operator Training & License Examination F-Administrative (5)
G-Operator Error (Explain) Exhibit I - Same Source H-Other (Explain) i i
l
DOCKET NO: 50 369 UNIT: McGuitc 1 DATE: 10/15/91 NARRATIVE
SUMMARY
MONTil: September 1991 McGuire Unit 1 began the rnonth of September operating at 100% full power. -
The unit operated at or near 100% full power until 2105 on 09/19/91, when a load reduction was conumenced to take the unit off-line for its end of cycle '7' refueling outage. The unit was taken off line at 0634 on 09/20/91. The unit retnained shut down as of the end of the nionth, i
Prepared by: S. W. Moser Telephone: 704 373 5762
l liONTilLY REFUELING INF_ORMATIOfL REOUEST i
- 1. Facility names McGuire. Unit 1
- 2. Schedulud next refueling shutdown: Sfptember 1991
- 3. Scheduled restart following refueling _ November 1991 Tile PROJECT MANAGER llAS DEEli ADVISED BY SEPARATE COMMUNICATION OF ANY T.S. Cl!ANGE OR LICENSE AMENDMENT. TilEREFORE, QUESTIONS 4 TilROUGli 6 WILL NO LONGER BF, MAINTAINED IN TilIS REPORT. 4
- 4. Will refueling or resumption of operation thoroafter require a technical specification chango or other licenso amendment?
If yes, what will those bo?
If no, has roload design and core configuration boon reviewed by Safoty Review Committoo regarding unrovioWod safoty questions?
- 5. Schedulod date(t ) for submitting propocod licensing action and supporting information:
- 6. Important licensin.,1 co7siderations (now or differont design or ;
supplier, unroviewed cr%ign or performance analysis methods, '
significant changes la design or now operating procedures). '
- 7. . Number of fuel assemblis1 (a) in the coros m ,
(b) in the spent fuel pool M *
- 8. Present licensed fuel pool capacity: .13.5 1 Size of roquested or planned increaso: ---
- 9. Projected date of last refuell.ig which can be accommodated by present licensed capacity: March 2006 DUKE POWER COMPANY DATE: October 15, 1991 Hame of
Contact:
J. A. Roavis Phone: 294-373-7567 i
l ll L _. _, , _ . _ . ,
OM Fall % LATA E[f7 T 10CIET C 'N70 I410 OttitiL15.1Mi 2[W!ht Sig LPFilif D IV F . A . b i l lim _
'(LIFONE 7M-373;Ui?_ _
! Urit Nase: McBa re 2
- 2. Reperting f eries !+ptester 1, iiil te; tester 30, 1991
- 3. Literted the: sal l'aer (Mat): 3411
- 6. hastplate Fatin; (Ert-ti FWeh 1754 holes *kaitplate fattt.g
- 5. Design Elt;trical Eatir; (Net neh 119? (Ertst rWe) talculated at
- 6. Maunt ie;nhble Ca;attty (Eress Weit !!71 1450.000 NA 1 90 p eer
- 7. " Angus te;endatle (netsty (htt %eh !!E9 fatter ter fige til, 9, if Char;es Otter in Carathty Fatir;s (ltens keter 3 itar.1;h 7) Eir4te Last NL*l6-N20.
Ettert. Este Featensi
- 9. Feuer Level 10 hhlth Pestricted, if Ary (het rath
- 10. Reance for Festrictitra, If any:
This Mcoth Yr, ted ate Cusalative
- 11. He. ,r s it f<eur tirt; f er tt d 720.0 6551.0 66479.0 lE. Later Of brs Seattcr Was Critical 196.5 64F3.3 51103.4
!?. Feattor Feserve E%tjen Hc rs -+- 14. %rs Etter ater CrLine 694.3 6479.1 502E0.9
- 15. Unit reserve Etatd.vn H m t - -+- - 16. Eress iternal Erergy Generatet 'NM 231t53$ 215t9326 164174617
- 17. Eress Electrical Ene ;y Generated (M.N 789721 7490959 5742 160 IB. f4et Ele:tfical Energy Benerated (m) 757647 7tl3Xl 55r77447
- 19. Uq t Service fatter %4 f 2.9 75.6
- 20. Unit h ailability Facter 96.6 SE.9 'd . 6
- 21. Urtt Capa: tty Fatter (Utin; KDC het) 93.2 97.! ,E.P E2. LNt Cap:lty f act;,r (Using IER Net: E9.2 43.3 70.2
- 23. lmt Ftrced Octage Eate 3.t 1.1 9.1 duled No t ! M 0
- 24. hthan RefueI SaIng Ove? January hmths199 f T[te,-hwee
? te, anks,ratit-n of Eachh
~
- 25. If At L:wn At Ere Of Feprt Ferttd. Estiested 0[te of Startupt _
- 26. Uritt in fest itates (Frh.t t: Ceseercial Operat e : Ferecast th itw ed IN!!!E Ek!T!:Eth __
, INiilAL ELEtiFIClif ,
1 9ERClat CFEFATICs l
i 1
OTIFAllM LA1A E(Prji 100f1 W3 M 370 Uhli Wite 2 I4IE [ @ lfl 1 19Y1 to Ittito ry 6, A. wijlait Till M NE 71. 6-:i?] 'dlL_
PNH NiuitfaJ."1 d
'1 n[FRE C41LY FUER L! VEL 'd] AVIF ACE I AILY l'00 LEVEL (Mit-Neu (Milt 4t U 1 1114 17 1117 2 1113 _ _ _ _
it 1101_
3 J1L4_ 19 _1116 4 fllt 00 IUJ.
3 1119 21 1))6 6 IllB El 1112 9 23 1111
_ 11)?
E 1116 24 'lP1 9 1116 Et .___
!?9 10 litt E6 46 11 1117 27 7U..
12 1115 28 1123 13 lijt 29 11.D 14 1099 30 !!E7 15 ._U 16
!! 1116 6
~
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-370 -
UNIT NAME richuixt, 2 DATE 1u/13/ y 1
- REPORT MONTH Septertber 1991 COMPLETED BY s. w. riv s t a TELEPHONE </us)-Jea-atoi (1) 2) (4) (5)
'l E HOD i T A OF LICENSE 1 N Y S SHUT EVENT SYS- CAUSE AND CORRECTIVE l j O P DURATION O DOWN REPORT TEM COMPONENT ACTION TO
! . DATE E HOURS N R/X NO. CODE CODE PREVENT FICURRENCE ;
2 91 9-25 F 25.73 A 2 CH VALVEX MANUAL REACTOR / TURBINE TRIP DUE TO FEEDWATER VALVE FAILED CIDSED
! 19-P 91- 9-26 F -
3 --
CG XXXXXX PRIMARY CHEMISTRY 20-P 91- 9-27 F --
A --
CH PUMPXX_ MAIN FEEDWATER PUMP 'A' PROBLEMS 21-P 91- 9-27 F --
B --
IA INSTRU NUCLEAR INSTRUMENTATION TESTING 1
3 I
I I
(1)F Forced (2)Reason (3)Method: (4)
- Exhibit G - Instructions S Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data '
B-Maintenance or test 2-Manual Scram Ent W Sheets For Licensee C-Refueling 3-Automatic Scram Event Report (LER D-Regulatory Restriction 4-Other (Explain) File (NUREG-0161)) ,
E-Opspator Training & License Examination F-Administrative (5)
G-Operator Errc. (Explain) Exhibit I - Same Source H-Other (Expla.., l i
l
D' 4 DOCKET NO: 50 370 UNII: McGuire 2 DATE: 10/15/91 NARRATIVE
SUMMARY
MONTil: September 1991 McGuire Unit 2 began the month of September operating at 1006 full power.
The unit operated at or near 100% full power until 1450 on 09/25/91, when feedwater containment isolation valve 'CP 26' failed closed due to an apparent grounded solenoid. The reactor was manually tripped before the automatic trip on low steam generator level. The unit was placed on line at'1635 on 09/26/91, and a power ecalation was commenced.
During the power increase the unit was held at 28% power from 1900 to 2104 on 09/26/91 for chemistry, at 356 power from 2231 on 09/26/91 to '
0251 on 09/27/91 for governor valve swing, at 40% power from 0322 to 0529 on 09/27/91 for main feedwater pump problems, and at 49% power from 0700 to 0841 on 09/27/91 for nuclear instrumentation calibration.
The unit reached 100% full power at 0157 on 09/28/91, and operated at 100% full power for the remainder of the month.
Prepared by: S. W. Moser.
Telephone: 704 373 5762
.. l MONTHLY REFUELil10 INFORMATION REOUEST
- 1. Facility name McGuire. Unit 2
-2. Scheduled next refueling shutdown: January 1992
- 3. Scheduled restart following refueling: March 1EER Ti!E PROJECT MANAGER !!AS BEEN ADVISED DY SEPARATE COMMUNICATION OF ANY T.S. CilANGE OR LICENSE AMENDMENT. THEREFORE, QUESTIONS 4 Ti!ROUGli 6 WILL NO LONGER DE MAINTAINED IN TilIS REPORT.
- 4. Will refueling or resumption of oporation thoroafter require a technical specification change or other license amendment?
If yes, what will those bo?
If no, has reload design and coro configuration boon reviewod by Safety Review Committoo regarding unroviewed safety questions?
- 5. ' Schedulod date(s) for submitting proposed licensing action and supporting information:
- 6. Important licensing considerations (now or different design or supplier, unreviewed design or performanco analysis methods, significant changes-in design or now operating procedures).
- 7. Number of fuoi assemblics (a) in the core: 122 (b) in the spent fuel pools 112
- 8. Present licensed fuel pool capacity: 1463
_ Size of requested or planned increaso: ---
. 9. Projected date o. last refueling which can be accommodated by
] present licensed capacity: December 2003 f
1 l
+ DUKE POWER COMPANY DATE: Qctober 15, 1991 Name of
Contact:
J. A. Roavig Phones 704-373-7567 1
!