Text

'

Y C:mm:nwalth Edb:n

~

)

1400 Opus Place C

C Downers Grove, Illinois 60515

\\

November 8, 1994 Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Attention:

Document Cor. trol Desk

Subject:

Fracture Mechanics Evaluation of Residual Heat Removal System Heat Exchanger Inlet and Outlet Nozzle to C_ hell Melds Byron Nuclear Power Station, Units 1 and 2 NPF-37/66; NRC Docket Nos. STN 50-454/455 Braidwood Nuclear Power Station, Units 1 and 2 NPF-72/77: NRC Docket Nos. STN 50-456/457

References:

1)

August 25, 1992 letter, T. W.

Simpkin to

)

T.

E. Murley, Byron /Braidwood Stations Flaw 1

Evaluation Methodology for RHR Heat Exchanger Nozzle to Shell Welds 2)

September 15, 1993 letter, J. A.

Bauer to T. E. Murley, Withdrawal of Request for NRC Review and Approval of Flaw Evaluation Methodology for RHR Heat Exchanger Nozzle to Shell Welds 3)

November 21, 1991 letter, R. M.

Pulsifer to T. J.

Kovach, Residual Heat Removal Heat Exchanger Nozzle to Shell Welds (TAC NO. M82087)

In Reference 1) Commonwealth Edison Company (Comed) transmitted Westinghouse Electric Corporation (Westinghouse)

Report WCAP 13454, " Fracture Mechanics Evaluation, Byron and Braidwood Unit 1 and 2, Residual Heat Exchanger Tube Side Inlet and Outlet Nozzles," dated August 1992 (Proprietary) to the Nuclear Regulatory Commission (NRC) Staff for their review and approval.

WCAP 13454 was submitted in order to obtain Staff approval of a methodology with which to disposition flaws in the Residual Heat Removal (RHR) System Heat Exchangers (HXs) which are classified as American Society of Mechanical Engineers (ASME)

Code Section III Class 2 components.

k onin\\brthJiwl3454.gfil 9411150538 941108

. \\

PDR ADOCK 05000454 L

P PDR

NRC Document Control Desk November 8, 1994 In Reference 2) Comed withdrew WCAP 13454 from further Staff consideration, agreeing with the Staff that since the methodology was not required for flaw disposition at that time it would be more appropriate for the methodology to receive applicable-ASME Code committee (s) review and approval prior to being submitted to the Staff for their review and approval.

Comed also stated that if, at any time in the future, this methodology was required for flaw disposition at either Byron or Braidwood Stations, that it would be resubmitted for an expedited Staff review and approval.

The current inspection of the Braidwood Unit 2 RHR HX inlet and outlet nozzle to shell welds requires use of this methodology for flaw disposition.

Therefore, Comed is resubmitting WCAP 13454, " Fracture Mechanics Evaluation, Byron and Braidwood Unit 1 and 2, Residual Heat Exchanger Tube Side Inlet and Outlet Nozzles," dated August 1992 (Proprietary) to the Staff for their expedited review and approval of the methodology contained therein.

Comed would like to clarify that Comed is not asking the Staff for their approval of the 90% acceptance criteria analyzed in WCAP 13454 at this time.

Comed will retain the 60% acceptance criteria documented in the Safety Evaluation transmitted in Reference 3).

Accordingly, attached you will find one copy of WCAP 13454,

" Fracture Mechanics Evaluation, Byron and Braidwood Unit 1 and 2, Residual Heat Exchanger Tube Side Inlet and Outlet Nozzles,"

dated August 1992 (Proprietary) and one copy of WCAP 13455,

" Fracture Mechanics Evaluation, Byron and Braidwood Unit 1 and 2, Residual Heat Exchanger Tube Side Inlet and Outlet Nozzles,"

dated August 1992 (Non-Proprietary).

As WCAP-13454 contains information proprietary to the Westinghouse Electric Corporation, it is respectfully requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with Title 10, Code of Federal Regulations, Part 2, Section 790 (10 CFR 2.790).

Due to the expedited nature of this submittal, WCAP 13454 is not currently supported by an affidavit signed by Westinghouse, the owner of the informal 1on.

Westinghouse will provide an affidavit which sets forth the basis upon which the information may be withheld from public

)

disclosure by the Commission and addresses with specificity the considerations listed in 10 CFR 2.790 (b) (4) as soon as pnesible.

Comed and Westinghouse regret any inconvenience that tha absence of this affidavit causes the Staff.

k;\\nla\\brdwd\\w13454,wpf\\2 1

NRC. Document Control Desk November 8, 1994 Correspondence with respect to the proprietary aspects of the

' items listed above should be addressed to N. J. Liparulo, Manager of Nuclear Safety & Regulatory Activities, Westinghouse Electric Corporation, P. O. Box 355, Pittsburgh, Pennsylvania 15230-0355.

Please address any questions or comments regarding this submittal to this office.

t Sincerely,

<(

/

l Harold D._fontious, Jr.

Nuclear Licensing Administrator :

WCAP 13454 j :

WCAP 13455 cc:

J.

B.

Martin, Regional Administrator - Region III G.

F.

Dick, Byron Project Manager - NRR R.

R. Assa, Braidwood Project Manager - NRR H.

Peterson, Senior Resident Inspector - Byron S. G.

DuPont, Senior Resident Inspector - Braidwood Office of Nuclear Facility Safety - IDNS I

l 1

k : \\ nla \\ br dwd\\w134 54.w;'t \\ 3

1 1

ATTACHMENT 1 l

WCAP 13454 (Proprietary)

FRACTURE IECHANICS EVALUATION BYRON AND BRAIDWOOD UNITS 1 AND 2 RESIDUAL HEAT EXCHANGER j

TUBE SIDE INLET AND OUTLET NOZZLES AUGUST 1992 t

k ; \\ nla \\ tirdwd\\w134 54, wp t \\ 4

l ATTACHMENT 2 WCAP 13455 (Non-Proprietary)

FRACTURE MECHANICS EVALUATION BYRON AND BRAIDWOOD UNITS 1 AND 2 RESIDUAL HEAT EXCHANGER TUBE SIDE INLET AND OUTLET NOZZLES AUGUST 1992 I

k:\\nla\\brdwd\\w13454.wpis5

m.

CLASS 3 WCAP 13455 FRACTURE MECHANICS-EVALUATION BYRON AND BRAIDWOOD UNITS 1 AND 2 RESIDUAL HEAT EXCHANGER TUBE SIDE INLET AND OUTLET N0ZZLES 9

August 1992 J

f W. H. Bamford H. Jambusaria Y. S. Lee J. P. Houstrup Reviewed by M W S. Tandon.

t Approved b D. C'T Adamonis, Manager Structural Mechanics Technology r

i I

WESTINGHOUSE ELECTRIC CORPORATION Nuclear and Advanced Technology Division P.O. Box 355 Pittsburgh, Pennsylvania 15230-355 C 1992 Westinghouse Electric Corp.

All Rights Reserved WPD480:IbO11792 Gn A cy m n-n f

J-Q U hJ l I "

V

d TABLE OF CONTENTS

1.0 INTRODUCTION

1.1 Code Acceptance Criteria: Class 1 Components 1.2 Acceptance Criteria for Class 2 Components 1.3 Geometry 2.0 LOADING CONDITIONS, FRACTURE ANALYSIS METHODS, AND MATERIAL PROPERTIES 2.1 Transients 2.2 Stress Intensity Factor Calculations 2.3 Fracture Toughness 2.4 Thermal Aging 2.5 Allowable Flaw Size Calculation 3.0 SUBCRITICAL CRACK GROWTH 3.1 Analysis Methodology 3.2 Crack Growth Rate Reference Curves 3.3 Residual Stresses 3.4 Stress Corrosion Cracking Susceptibility 4.0

SUMMARY

AND RESULTS 4.1 Flaw Evaluation Charts Construction 4.2 Conservatisms in the Flaw Evaluation

5.0 REFERENCES

APPENDIX A: Development of Unified Flaw Acceptance Criteria for Austenitic Piping APPENDIX B: Welding Procedures and Shop Travellers:

Byron and Braidwood Residual Heat Exchangers WPO453;1b!081492 i

-~

SECTION 1.0 INTRGDUCTION This fracture mechanics evaluation has been carried out to determine the largest size of indications which can be accepted for the residual heat exchanger-inlet and outler nozzles.

The results of this evaluation are presented in the form of flaw evaluation charts contained in Section 4.

The technical basis for these charts is contained in the remaining sections, and also in Appendix A.

1.1 Code Acceptance Criteria:

Class 1 Components The evaluation procedures and acceptance criteria for indications in Class I austenitic stainless piping are contained in paragraph IWB 3640 of the ASME Boiler and Pressure Vessel Code,Section XI.[1] The evaluation procedure is applicable to all the materials within a specified distance from the weld centerline, s/rt, where r - the pipe nominal outside radius and t is the nominal wall thickness.

For example, at the RHX nozzle, this distance is calculated to be 1.62 inches, which encompasses regions of the heat exchanger, as well as part of the RHR line. All the materials in this region are SA 240 Type 304 stainless steel, but these acceptance criteria are applicable for all grades of Types 304 and 316 stainless steels.

The evaluation process begins with a flaw growth analysis, with the requirement to consider growth due to both fatigue and stress corrosion cracking.

For pressurized water reactors only fatigue crack growth needs be considered, as discussed in Section 3.

The methodology for the fatigue crack growth analysis is described in detail in Section 3.

The calculated maximum flaw dimensions at the end of the evaluation period are then compared with the maximum allowable flaw dimensions for both normal operating conditions and emergency and faulted conditions, to determine acceptability for continued service.

Provisions are made for considering flaws projected both circumferentially and axially.

i l

WPO453:1bf081492 1-1

tr

_ne G

45-45-Ni

[g m 3......

442 a

WE Cw G-5 62 FCEES 6th M

2' M E' DwG-5 6 t S *0R E S "C'

\\Pa \\'

q, /4 ' \\

3 f3 r,/[ 6490 mo.g Q HLe o meCut ss 19Cf wa 7-C 90*

I

,b l e k* k

'Ja*E % CCA*ED NS (

f

.w' (8) na0LES 2 io A so

~ ZZ5 fD.

L kg "gh

~~

N A. 3(, ANCHOR 80L S T

h 0RIEff T-225~l I (#1 CrQ o SttSuic M Set b[g h

$ff CETAIL "A' CMQ 56Z31 ASut FJ O wo.

&

  • C o e tNO" 43 4

E F. (

WE W/t'/g*Qofo M

g,

??

e w

w

.glo.o i

/

%..... -,6

,f/}

.m c

e ms ssss I

N p

i e* --- l s

Y(

t' h

i t

E 3 SIDE VIEW i

2s

};,

w

~L

~

f:71' h,T.',Q g

W.

(.' 1 fI it il_/

W

-Y N

IS '

, j

='

j {nr hi -- ~ -_g-Ap s.

so-I h.

" ?'

T,

u~o meme see' scc Oc+. v o*' 5'24 o" w o*c mag emf.ee s,. <.u o l

Figure 1-1.

Geometry of the Residual Heat Exchanger i

WF0863/111191:10 1-3 t

WALL

__'IHlCKNESS t _

i i

6-l r

i

_. a s-TYPICAL EMBEDDED FLAW INDICATION l

WALL THICKNESS t l

l I

v ' 4 9

I

~

~a i

f TYPICAL SURFACE l

FLAW INDICATION Figure 1-3.

Typical Notation for Surface and Embedded Flaw Indications

~;1.Ib!081392 1-5

SECTION

1.0 INTRODUCTION

1 This fracture mcchinics evaluation has been carried out to determine the largest size of indications which can be accepted for the residual heat exchanger inlet ar.d outlet nozzles.

The results of this evaluation are presented in the 'orm of flaw evaluation charts contained in Section 4.

The these charts is contained in the remaining sections, and technical bas a

also in Appendix n.

1.1 Code Acceptance Criteria: Class 1 Components i

The evaluation procedures cceptance criteria for indications in Class I austenitic stainless piping are contained in paragraph IWB 3640 of the ASME Boiler and Pressure Vessel Code,Section XI.[1] The evaluation procedure is applicable t' all the materials within a specified distance from the weld l

o centerline, s/rt, where r - the pipe nominal outside radius and t is the i

nominal wall thickness.

For example, at the RHX nozzle, this distance is calculated to be 1.62 in -

, which encompasses regions of the heat exchanger, cs well as part of the RHR line. All the materials in this region are SA 240 l

Type 304 stainless steel, but these acceptance criteria are applicable for all grades of Types 304 and 316 stainless steels.

The evaluation process begins with a flaw growth analysis, with the requirement to consider growth due to both fatigue and stress corrosion cracking.

For pressurized water reactors only fatigue crack growth needs be considered, as discussed in Section 3.

The methodology for the fatigue crack growth analysis is described in detail in Section 3.

The calculated maximum flaw dimensions at the end of the evaluation period are then compared with the maximum allowable flaw dimensions for both normal operating conditions and emergency and faulted conditions, to determine acceptability for continued service.

Provisions are made for considering flaws projected both circumferential1y and axially.

i l

l WPO453:1b!081492 1-1

(

(

The allowable flaw sizes have been defined in the tables of IWB 3640 based on maintaining specified safety margins on the loads at failure. These margins are 2.77 for normal and upset conditions and 1.39 for emergency and faulted conditions. The calculated failure loads are different for the base metal and the flux welds as they have different fracture toughness values, as discussed in Section 2.

(Non-flux welds, such as gas tungsten arc welds, have the same properties as the base metal.) The failure loads, and consequently the allowable flaw sizes are larger for the base metal than for the welds.

Allowable flaw sizes for welds are contained in separate tables in IWB 3640.

1.2 Acceptance Criteria for Class 2 ComponentsSection XI in its present form contains no acceptance criteria specific to Class 2 components.

Instead, the user is referred to the criteria for Class I components, which have been described above. Work has been underway for some time in the Section XI committee to develop evaluation criteria for Class 2 and Class 3 components. This work has been used to develop a flaw evaluation chart specific to the Byron and Braidwood Residual Heat Exchangers. The detailed technical basis is contained in Appendix A of this report. This approach is consistent with the approach used for Class I components, and in fact allows one to reproduce the acceptance criteria for Class 1 systems.

The approach utilizes the original design criteria for the component and maintains this design margin in the presence of a flaw. The corrections for flux welds are exactly the same as those for Class I components.

1.3 Geometr_y The geometry of the residual heat exchanger is shown in Figure 1-1, the details of the inlet and outlet nozzles of the tube side is shown in Figure 1-2.

The tube side of the residual heater exchanger is designed to Class 2 criteria, while the shell side is designed as Class 3.

The notation used for surface and embedded flaws in this work is illustrated in Figure 1-3.

The fracture and fatigue crack growth evaluations carried out to develop the handbook charts have employed the recommended procedures and material properties for. stainless steel prescribed in paragraph IWB 3640 and Appendix C oi Section XI.

WPO453.1bl081692 1-2

s

  • s'

.. O*

c a

, 4s-N,

4.,, w gs,. o......

e-43* II DwG S t.2 5 ccE E S' E E b T -+++- E' DwG 5625 *04 E S -'C9 o \\ "s v

/e,,. N

}l'.

'i t **No o r e/

( WLMO. cole,.

m no.

e ig

,__2 I

,d:b::s i e '/g* k

\\ tainst Et,, JC A'*ED NS (,

I 8

TOP VIEW A'

+

(s).s0LES 2 ioia so k

SEPCC.$vstAcoJ (

190' ! 2 _ M

NMZ 5 C M.

ON49 f SC sost 2-A af. ANewou toLTS d ORistr 7-22G 7-1

'ai ore e i;

sciswic 4 see dy,'c"k-A see os'as 'A' D4 %E.3.b asnar r y o wo.

43%'oo.>gaca

-r WK w/ i k 'a e*. f

- I "aS i

o r.t.

p.

%.e-

.s g l..

t 5

/

%... n i

^

r o-c s. A

.m t

e N

i

.I e

6 Ie3

__. _ [

.i

(

w/

t r

E 4

r I

,e E

>O a

w

-c SIDE VIEW 4

=

-h fT*.

q

4,li yQw l

~

h

. e s

a j

(~ 71' b,'U:.3 m

L.'. t fit O

/

W i

y shy / n,-

N w-s e

/* \\

%,r1-w f

l

'h~,

r t

\\

=8NOwott SEE SEr DE* % 'u' D****'3" D' D*G-%23/h ELE V. * ?? 69 '(o met o t

l Figure 1-1.

Geometry of the Residual Heat Exchanger i

WPF0863/111191:10 1-3 I

I

o

.e l

i bb i

WALL REINFORCD E T i

)I

(

0.10" i' actual walli i

6 thickness 4 l

Jb k

N0ZZE Figure 1-2.

Geometry of the Tube Side Nozzles (Inlet and Outlet Nozzles are Identical)

WPO453:1bt080592 1-4

WALL

-_THlCKNESS t 6-1m 2

L a

s-TYPICAL EMBEDDED FLAW INDICATION WALL

__ THICKNESS t I

mr p

9 JL

  • -a l

TYPICAL SURFACE FLAW INDICATION Figure 1-3.

Typical Notation for Surface and Embedded Flaw Indications WPO453.1b/081392 1-5

SECTION 2.0 LOAD CONDITIONS, FRACTURE ANALYSIS METHODS AND MATERIAL PROPERTIES The loading conditions used in the analyses described herein were taken directly from the equipment specification. The latest fracture analysis technology has been employed in conducting this analysis. The material properties have been taken from the latest version of the Reference 1 ASME Code.

2.1 Transients and Load Conditions The design transients for the residual heat exchanger are very minimal, because this component operates only during plant shutdown conditions.

Therefore, the only transient conditions which it experiences are the startup and shutdown of the system. This coincides with the shutdown and startup of the plant, respectively. The appropriate limiting load conditions for the location of interest are discussed next.

The loading conditions which were evaluated include thermal expansion (normal and upset), pressure, deadweight and seismic (OBE and SSE) loadings.

The RHR piping forces and moments for each condition were obtained from the ASME Code Section III calculations performed by Sargent and Lundy and Westinghouse for Byron and Braidwood Units 1 and 2 in References 2 through 5.

These loads

[6] were found to be bounded by the equipment specification design loadings for the heat exchanger nozzles (G-679150 Rev. 1). Consequently, the evaluation performed using the design loadings is applicable to Byron and Braidwood Units 1 and 2.

Residual stresses were not used in this portion of the evaluation in compliance with the Code guidelines. A further discussion of residual stresses is contained in Section 3.2.

The stress intensity values were calculated using the following equations:

S I - P, + P, F

SI = - ' + 1 (M, + M, + M *]"

A Z-WPo453 lb!081492 2-1

where F, - axial force component (membrane)

M,,

M,, M, - moment components (bending)

A - cross-section area Z - section modulus The section properties A and Z at the weld location were determined based on the minimum pipe dimensions.

This is conservative since the measured wall thickness at the weld is generally larger.

i l

The following load combinations were used.

A.

Normal / Upset - Primary Stress Pressure + Deadweight + OBE B.

Emergency / Faulted - Primary Stress l

1 Pressure + Deadweight + SSE C.

Normal / Upset - Total Stress Pressure + Deadweight + OBE + Normal Thermal D.

Emergency / Faulted - Total Stress Pressure + Deadweight + SSE + Normal Thermal 2.2 Stress Intensity Factor Calculations One of the key elements of the fatigue crack growth calculations is the determination of the driving force inherent to the flaw, or stress intensity factor (K ).

This was done using expressions from available literature.

In y

all cases the stress intensity factor calculations utilized a representation of the actual stress profile rather than a linearization. This was necessary WPO453:1b!081492 2-2

5 1

to provide the most accurate determination possible.

The stress profile was j

represented by a cubic polynomial:

l o(x) = A, + A, 5 + A, !

+ A, E

(2-1) t t

t 5

where x

.is the coordinate distance into the wall wall thickness t

=

stress perpendicular to the plane of the crack o

=

coefficients of the cubic fit A,

For the surface flaw with length six times its depth, the stress intensity factor expression of [McGowan and Raymund [ ))"' was used. The stress intensity factor Kg ($) can be calculated anywhere along the crack front.

The point of maximum crack depth is represented by $ = 0.

The following expression is used for calculating Ky ($), where d is the angular location around the crack.

P o.s na si n 9)m( Ap, + _2 a (cos,

_a 2

2 K,($) =

z n t (2-2)

_A

. Q C

2 2

1a 3

  • g f, + 4 Ay,)

A

'I The magnification factors H ($), H,( ),H( ) and H,( ) are obtained by the o

2 procedure outlined in reference [8].

The stress intensity factor calculation for a semi-circular surface flaw, (aspect ratio 2:1) was carried out using the expressions developed by [

[ ))'".

Their expression utilizes the same cubic representation of the stress profile and gives precisely the same result as the expression of

[

]"' for the 6:1 aspect ratio flaw, and the form of the equation is similar to that of [

]"' above.

~

WPO453:1bl081692 2-3 i

The stress intensity factor expression used for a continuous surface flaw was that developed by [.

[ ] ]"'.

Again the stress profile is represented as a cubic polynomial, as shown above, and these coefficients as well as the magnification factors are combined in the expression for K, i

K, = vhia (2-3) where F, F ' f, F, are magnification factors, available in [9].

i 2

a 2.3 Fracture Toughness l

The residual heat exchanger is constructed of SA 240 stainless : teel, type 304. The weld at the nozzle was made by the shielded metal arc process as verified by the shop traveller and the weld procedure referenced therein.

The fracture toughness of the base metal has been found to be relatively very high, even at operating temperatures [10], where the J values have been found a

2 to be well over 2000 in-lb/in.

Fracture toughness values for weld materials have been found to display much more scatter, with the lowest reported values significantly lower than the base metal toughness. Although the J values u

reported have been lower, the slope of the J-R-curve is still large for these J cases.

Representative values for d were obtained from the results of u

u Landes, et. al. [11], and used in the development of the fracture evaluation methods.

[

jo This value of toughness was used in the original development of the flaw acceptance criteria, and has been shown to be extremely conservative relative to test results for larger specimens obtained since that time.

This subject is further discussed in Section 4.2.

WP0453:1bl081492 2-4

L -'

2.4 THERMAL AGING Thermal aging at operating temperatures of reactor primary piping can reduce the fracture toughness of cast stainless steels and, to a lesser degree, stainless steel weldments.

Because of the lower operating temperature (400*F) of the residual heat exchanger, and the fact that the materials are type 304 stainless (not cast), thermal aging in this component will be negligible.

2.5 Allowable Flaw Size Determination The critical flaw size is not directly calculated as part of the flaw evaluation process for stainless steels.

Instead, the failure mode and critical flaw size are' incorporated directly into the flaw evaluation technical basis, and therefore into the tables of " Allowable End-of-Evaluation Period Flaw Depth to Thickness Ratio," which are contained in paragraph IWB 3640. The same is true for the revised acceptance criteria for Class 2 components.

Rapid, nonductile failure is possible for ferritic materials at low temperatures, but is not applicable to stainless steels.

In stainless steel materials, the higher ductility leads to two possible modes of failure, plastic collapse or unstable ductile tearing. The second mechanism can occur when the applied J integral exceeds the J,, fracture toughness and some stable tearing occurs prior to failure.

If this mode of failure is dominant, the load carrying capacity is less than that predicted by the plastic collapse mechanism.

The allowable flaw sizes of paragraph IWB 3640 for the high toughness base materials were determined based on the assumption that plastic collapse would be achieved and would be the dominant mode of failure.

[

i b

] e.e.e WPO453:1bl081492 2-5

~

l SECTION 3.0 FATIGUE CRACK GROWTH j

In applying Code acceptance criteria as introduced in Section 1, the final flaw size a is defined as the flaw size to which the detected flaw is f

calculated to grow at the end of a specified period, or until the next inspection time. This section will examine each of the calculations, and provide the methodology used as well as the assumptions.

3.1 Anal _ysis Methodology The methods used in the crack growth analysis reported here are the same as those suggested by Section XI of the ASME Code. The analysis procedure involves postulating an initial flaw at specific regions and predicting the growth of that flaw due to an imposed series of loading transients.

The input required for a fatigue crack growth analysis is basically the information necessary to calculate the parameter AK which depends on crack and structure 7

geometry and the range of applied stresses in the area where the crack exists.

Once AK is calculated, the growth due to that particular stress cycle can be y

calculated by equations given in Section 2.2 and figure 3-1.

This increment of growth is then added to the original crack size, and the analysis proceeds to the next transient. The procedure is continued in this manner until all the transients known to occur in the period of evaluation have been analyzed.

The only transients considered in the analysis were the startup and shutdown of the RHR system.

These transients are spread equally over the design lifetime of the vessel.

Crack growth calculations were carried out for a range of flaw depths of three basic types.

The first two types were surface flaws, one with length equal to six times the depth and another with length equal to twice the depth. The third type was a continuous surface flaw which represents a worst case condition for surface flaws.

WPO4511bl081492 3-1

3.2 Crack Growth Rate Reference Curves The reference crack growth law used for the stainless steel was taken from that developed by the Metal Properties Council - Pressure Vessel Research Committee Task Force in Crack Propagation Technology.

The reference curve has the equation:

b = CFS AK" (3-7) dN where b = crack growth rate, inches per cycle dN Material coefficient (C = 2.0 x 10"I9)

C

=

frequency coefficient for loadings (F = 2.0)

F

=

R ratio correction coefficient (S = 1.0 - 0.502 R )-4.0 2

+

S

=

Material property slope (=3.0321) n Stress intensity factor range, psi j in AK

=

This equation appears in Section XI, Appendix C (1989 Addendum) for air environments and its basis is provided in reference [12], and shown in figure 3-1.

For water environments, an environmental factor of 2 was used, based on the crack growth tests in PWR environments reported by Bamford [13].

1 3.3 Residual Stresses Since the residual heat exchanger vessel-to-piping welds have not been stress-relieved, residual-stresses are likely present.

For fatigue crack growth analyses, these stresses are included directly.

In general, the distribution of residual stresses is strongly dependent on the i

degree of constraint of the structure.

The stiffer the structure, the higher the residual stresses.

[

).u

~

WPO453:1bl081492 3-2

\\

~

I

[

a,c.e

[

4,C.8 3.4 Stress Corrosion Cracking Susceptibility In evaluating flaws, all mechanisms of subcritical crack growth must be evaluated to ensure that proper safety margins are maintained during service.

Stress corrosion cracking has been observed to occur in stainless steel in operating BWR piping systems. The discussion presented here is the technical basis for not considering this mechanism in the present analysis.

The residual heat exchanger tube side nozzles are exposed to only primary coolant water.

For all Westinghouse plants, there is no history of cracking failure in the reactor coolant system loop piping.

For stress corrosion cracking (SCC) to occur in piping, the following three conditions must exist simultaneously:

high tensile stresses, a susceptible material, and a corrosive environment.

Since some residual stresses and some degree of material susceptibility exist in any stainless steel piping, the potential for stress corrosion is minimized by proper selection of a material immune to SCC as well as preventing the occurrence of a corrosive environment.

The material specifications have taken into consideration compatibility with the system's operating environment (both internal and external) as well as other materials in the system, applicable ASME Code rules, fracture toughness, welding, fabrication, and processing.

WP0453:1b!081432 3-3

1000

/

~

' Lineer inwrpolation is recom-

[

[

~

monded to account for rotio dependence of water environment curves, for 0.25 <A < 0.65 for N7 f

~

shallow slope:

p h

[

500 1B$

8 = (1.01 X 10'11020K

~

/

dN

& p

/

[

4

~

0 = 3.75 A + 0.06 4

2

$fl l

/

  1. =Km,n IKm, s

200

/

/

Subourfoce flaws

[

]

(air onwronment) e

{ 100

~

.f8. (0.0267 X 100) A K 3.726 g

'O

~

/

Determine the AK st which the

/

gy 50 5

new changes try calculation of j

g4 g

the intereaction of the two

/

'k

$/t/

j eg Surface flows

[

z (water toector f

20 environment)

G epplicable for j

b

'oas < f ',QI M

10 g.gmin /Kanom I

N l

C

\\

7 ari

/

p f

$]

  • Lineer interpolation is recommended 6

en.

to account for A retio dependens of water environment curves,for a

g f

(

0.25 < A < 0.65 for steep slope:

g

~

U.

g Od 8' = (1.02 X 104) Og AK.95 5

,l ou tit tit 0, - 26sA 5.,25 A*Krnin /# men I

/

i l

I I Ill lil l

1 I

I IIIi i

1 2

5 7

10 20 50 70 100 Stress intensity Factor Range (AKj ksi[.)

Figure 3-1.

Reference Crack Growth Rate Curves for Stainless Steel in Air Environments [12].

WPF1260J/032792:10 3-4

I I

1 1501 35 16 1

.40i 28 13 00i 21.00 14 l

(10)

PIECE NO.1 PIECE NO 2 7.03 I

l A

~

f(,

l

[

I 1

I

\\

f 1

l I

! lis I

I I

>l I

2%

W, I

i 1

4-30)

- 21.09

\\

\\\\

t-40)

- 28.13 k

r I

i" E FtLLET

-35 16 i-m

-42.19 I

t-701 1

9 l

t j

10 8 enJ to 6 en.)

10 4 en.1 to 2 ewi to 2 en.1 10 4 in.1 (0 6 in.1 2.032 1.524 cm 1.016 cm 0.600cm 0 608 cm 1.016 em 1.624 cm Figure 3-2.

Maximum Principal Surface Residual Stress for a 10 inch Schedule 160 Pipe [14]

WPF1260J/032792:10 3-5 l

..c..

1 i

i l

4 Figure 3-3.

Through Wall Distribution of Residual Stress in a 10 Inch, Schedule 160 Pipe, in a Cross Section Adjacent to the Weld Center Line (15]

WPF1260J/032792:10 3-6

,w

1 SECTION 4.0

SUMMARY

AND RESULTS 4.1 Flaw Evaluation Charts Construction The acceptance criteria for surface flaws have been described in Section I for both Class 1 and Class 2 components.

For flaw evaluation in stainless steels, only the fatigue crack growth results must be calculated.

The allowable flaw depths were determined directly from the tables in IWB 3640 and from tables developed specifically for Class 2 components, as detailed in Appendix A.

The first set of data required for surface flaw chart construction is the final flaw size a,.

As defined in IWB-3611 of ASME Code Section XI, a, is the l

flaw depth resulting from growth during a specific time period which can be the next scheduled inspection of the component or until the end of design lifetime. Therefore, the final depth, a,,

after a specific service period of time must be used as the basis for evaluation.

The final flaw size, a,, can be calculated by fatigue crack growth analysis, which has been performed covering a range of postulated flaw sizes, and flaw shapes.

The crack growth calculational methods have been discussed in Section 3.

The results of the crack growth calculation showed that growth for a complete range of crack sizes was inconsequential for the entire service life of 40 years.

This was expected, since the region experiences so few cycles.

The allowable flaw size for Class I stainless steel piping and components is obtained directly from tables in paragraph IWB 3640, so the evaluation process is straightforward. The allowable flaw size for Class 2 piping and components was obtained directly through use of Appendix A.

I The allowable flaw size is calculated based on the most limiting transient for all normal operating conditions.

Similarly, the allowable flaw size for

)

emergency and faulted conditions is also determined.

The theory and methodology for the calculation of the allowable flaw sizes have been provided in Section 2 and Reference 16 for Class I components, and in Appendix A for Class 2 components.

Allowable flaw sizes were calculated for a range of flaw shapes.

WPO453:1blo81692 4-1

i Two dimensionless parameters which fully address the characteristics of a surface flaw, have been used for the evaluation chart construction:

o Flaw Length divided by the circumference, f/c o

Flaw Depth parameter a/t

where, wall thickness, in.

t

=

flaw depth, in.

a flaw length, in.

1

=

pipe circumference, in.

c

=

The flaw evaluation chart for the residual heat exchanger inlet and outlet nozzles is shown in Figure 4-1.

The chart has the following characteristics.

[

3.u i

WP0453:1h/081492 4-2

A detailed example on the use of the charts for a surface flaw is precanted below:

Surface Flaw Example Now suppose an indication is to be evaluated using the charts.

For the circumferential orientation:

a = 0.10" l = 6.1" t = 0.40" c = 44.0" The flaw characterization parameters then become:

a/t = 0.250 f/c = 0.139 Plotting these parameters on the surface flaw evaluation chart of F4.gure 4-1, it is quickly seen that the indication is acceptable, for both the class 1 and class 2 curves.

Embedded Flaw Example The flaw evaluation charts are equally useful for embedded flaws.

Suppose an embedded indication were discovered with the following dimensions:

2a = 0.2" l = 7.0" S = 0.1" t = 0.4" c = 44.0" The indication would be characterized as an embedded flaw, because the S dimension exceeds 0.4a.

The flaw characterization parameters then become:

2a/t =.5 1/c = 0.160 Plotting these parameters on the flaw evaluation chart in Figure 4-1 shows that the indication is acceptable for both the Class 1 and Class 2 acceptance WPO453.Ib!D81492 4-3

criteria. Note that for embedded flaws, the t;Lul depth "2a" of the flaw is plotted on the chart.

4.2 Conservatisms in the Flaw Evaluation The stress and fracture analysis results presented herein have been structured to be conservative at each step to ensure conservatism in the final result.

The stresses applied to the heat exchanger nozzles were taken from the vessel equipment specification loads, which represent bounding loads for the structure.

The actual loads for the Byron and Braidwood Units 1 and 2 heat exchangers [6] are approximately 60 percent of the design loads.

[

3...

1 WP0453.1bl081492 4-4

l e.c.e i

I i

i i

1 l

i

.1 i

i 1

Figure 4-1 Flaw Evaluation Chart for Byron and Braidwood Units 1 and 2 Residual Heat Exchanger Tube Side Nozzles WPO453:1bl080592 4-5 i

e.e..

i 1

1 ir i

a i

i i

Figure 4-2 Comparison of Fracture Toughness Results for Different Specimen Sizes, Submerged Arc Weldments WPO453:Ibl080592 4-6

SECTION

5.0 REFERENCES

1.

ASME Code Section XI, " Rules for Inservice Inspection of Nuclear Power Plant Components," 1983 edition (used for updated code allowable limits); 1983 edition, Winter 1985 Addendum (used for flaw evaluation of austenitic stainless steel piping); 1989 edition (used for reference crack growth curve, stainless steel).

2.

Jambusaria, H., " Residual Heat Exchangers: Braidwood Unit 2,"

Westinghouse Report No. 031804 Rev. O, Jan. 24, 1986.

3.

Jambusaria, H., " Residual Heat Exchangers:

Byron Unit 1," Westinghouse Report No. 031805 Rev. O, 2/27/92.

4.

Jambusaria, H., " Residual Heat Exchangers:

Byron Unit 2," Westinghouse Report No. 031806 Rev. O, 2/27/92.

5.

Jambusaria, H., " Residual Heat Exchangers:

Braidwood Unit 1,"

Westinghouse Report No. 031803 Rev. O, 2/27/92.

6.

Letter # BPM #1577 from D. J. Skoza of Commonwealth Edison Company to Janet Bunecicky of Westinghouse Electric Corporation,

Subject:

RHR Heat Exchanger Nozzle Loads, dated 2/12/92.

7.

McGowan, J. J. and Raymund, M., " Stress Intensity Factor Solutions for Internal Longitudinal Semi-elliptic Surface Flaw in a cylinder Under Arbitrary Loading", ASTM STP 577, 1979, pp. 365-380.

8.

Newman, J. C. Jr. and Raju, I. S., " Stress Intensity Factors for Internal Surface Cracks in Cylindrical Pressure Vessels", ASME Trans.,

Journal of Pressure Vessel Technology, Vol. 102, 1980, pp. 342-346.

9.

Buchalet, C. B. and Bamford, W. H., " Stress Intensity Factor Solutions for Continuous Surface Flaws in Reactor Pressure Vessels", in Mechanics of Crack Growth, ASTM, STP 590, 1976, pp. 385-402.

WP0480,1b!081792 5-1

10.

Bamford, W. H. and Bush, A.

J., " Fracture of Stainless Steel," in Elastic Plastic Fracture, ASTM STP 668, 1979.

11.

Landes, J. D.,

and Norris, D. M., " Fracture Toughness of Stainless Steel Piping Weldments," presented at ASME Pressure Vessel Conference,1984, 12.

James, L.

A., and Jones, D. P., " Fatigue Crack growth Correlations for Austenitic Stainless Steel in Air," in Predictive Capabilities in Environmentally Assisted Crackina," ASME publication PVP-99, Dec.1985.

13.

Bamford, W. H., " Fatigue Crack Growth of Stainless Steel Piping in a Pressurized Water Reactor Environment," Trans ASME, Journal of Pressure vessel technology, Feb.1979.

14.

" Studies on AISI Types 304, 304L, and 347 Stainless Steels for BWR Application, April-June 1975," General Electric Report NED0-20985-1, September 1975.

15.

Rybicki, E.

F., McGuire, P. A., Merrick, E., and West, J., "The Effect of Pipe Wall Thickness on Residual Stresses Due to Girth Welds," Trans ASME, Journal of Pressure Vessel Technology, Vol 104, August 1982.

16.

" Evaluation of Flaws in Austenitic Steel Piping," Trans ASME, Journal of Pressure Vessel Technology, Vol. 108, Aug. 1986, pp. 352-366.

17.

Wilkowski, G. et. al., " Analysis of Experiments on Stainless Steel Flux Welds," Battelle Columbus labs report for USNRC, number NUREG/CR 4878, April 1987.

WPO480.1bl081792 5-2

. ~.

.M APPENDIX A DEVELOPMENT OF UNIFIED FLAW ACCEPTANCE CRITERIA FOR AUSTENITIC PIPING A.I.0 INTRODUCTION There are currently rules in the ASME B&PV Code,Section XI, (Ref.(A3), for the evaluation of flaws in austenitic piping when the discovered indications exceed the allowable acceptance standards. These rules are complex, use relatively arbitrary " safety factors", require the knowledge of a " flow.

stress" that is very difficult to determine, and have arbitrary limits on the maximum flaw depths allowed, with the result that the compounded conservatisms have produced very conservative results.

The approach taken in developing these rules is that austenitic piping is very ductile and a failure of a pipe, whether flawed or not, will be by plastic collapse of the pipe cross section and has been verified by numerous experiments. A solution for the collapse load of a flawed pipe was developed in terms of the applied primary loads and the flawed pipe geometry using limit load theory with the yield stress replaced by a flow stress. This collapse stress is divided by a fixed safety factor (2.77 for Level A and B loadings and 1.39 for Level C and D loadings) to establish allowable stresses in the flawed pipe and these were back calculated to establish the allowable flaw t

size. It should be noted that the collapse equations were developed for a thin walled tube (R > t), for this is the only practical solution, and again.is conservative for real pipes which have thicker cross sections.

These solutions of Ref. (A3) have several limitations:

a)

They are available for Class 1 piping only.

b)

The allowable design stresses of Ref. (A1) have different values for each of the loading categories (Levels A, B, C, and D) that are not always consistent with the safety factors used.

WPO480:Ib!081792 A-1

P c)

The accumulated conservatisms are such that, for many cases, a new unflawed pipe will fail the criteria of Ref. (A3).

d)

There is no limit on axial membrane stress.

Although the predominant failure mode in piping is by bending, there are cases such as a flaw in an end cap weld where the membrane stress governs.

[ ).u WPO480:1bl081792 A-2

f A.2.0 CRITERIA The criteria of-the ASME B&PV Code,Section III, " Nuclear Power Plant Components", (Ref. (A1)) for the design of new components is based upon the premise that the materials used will be ductile and the failure mode wiil be by plastic collapse. The resulting minimum safety margin is the ratio of the collapse load of the structure to the maximum permitted loads in the structure. The collapse load of the structure is conservatively defined in Section III using limit load theory with the collapse stress equal to the yield strength of the material. These criteria are discussed in " Criteria of Section III of the ASME Boiler and Pressure Vessel Code for Nuclear Vessels",

ASME, 1964 (Ref. (A2)). Figure A2.1 is a reproduction of Fig. 2 of Ref. (A2) that demonstrates the safety margins for a beam of rectangular cross-section for both longitudinal membrane and membrane plus bending stresses.

t 3...

WPG480:1b!081792 A-3

4 i

i.

=

COLLAP3E STRE3s IA Pm = TDastLE STatss P =SEMHNC sTAtss b

Sg

  • YlELD STRE33 I.2 I'0 o

<<<<<<<<s<<<<

f M

/

h DE31CW LlurT3 m c.8 O.

/

/

E

/

6

.8

/

C

/

/

/

CA -

/

/

c'2 -

j

/

/

l 0

t t

t t

/

O C.2 C.s os 0,g g,n P,3 su l

COLLAP3E STRESS FOR COMBINED TENSION AND. BENDING l

(RECTANGULAR 3ECTiON) 1 I

Figure A2.1 Reproduction of Figure 2 of Reference A2

[ ).....

l l

l l

l WPO480:1bl081792 A-4

--_________.m_

.. =-

+

Collapso Strecs Solid Rectangle

[ThinWalledTube 1.5 4/u i

1.2 1.0 ///////

/

/

i Design l

0.8 (Pm+P.)/sv Limits j

0.6

/

/

/

0.4

?

j

/

0.2

/

/

/

0 i/

i 0

0.2 0.4 0. '6 0.8 1.0 Pm/Sy Figure A2.2 Collapse curve for a thin walled tube for comparison with Fig. A2.1

[ Ja,c,e l

WPO480.1bl081792 A-5

~, -.

y

l

[ ju

-A.3.0 FLAW NOMENCLATURE FOR A CIRCUMFERENTIAL FLAW i

The nomenclature used in evaluating a pipe with a circumferential flaw is

{

illustrated in Figure A3.1 and defined specifically as:

the maximum measured flaw depth projected to the end of the a

=

evaluation period.

l the maximum measured half flaw length in radians projected to the 0

=

end of the evaluation period.

t angle in radians to the neutral axis.

l B

=

pipe wall thickness.

t

=

t R

mean radius of pipe.

=

inside radius of pipe.

I R,

=

outside radius of pipe.

I R

=

o t

flow stress at plastic collapse.

g, k

Flaw a

+or

\\

=

=

l e%

r

=

l R

\\.-

A

(

t

=

\\

B /

1 l

=

=

J t

Neutral Axis

-or Figure A3.1 cross section c, flawed pipe.

WPO480:1b!D81792 A-6

4 A.4.0 FLAW EVALUATION DEVELOPMENT A.4.1 Limit On Membrane Plus Bending Stress

[)u

(

3...

I WPo4so:1blos1792 A-7 i

r r

, [ ]e.u t

i i

t' i

l 4

i i

i

}

t t

J r

r i

l l

l i

i i

1 l

l 1

l 2

~

WPO480:1bl081782 A-8

[ j u,

[ j o, FLAW DEPTH FLAW LENGTH O/ir RATIO 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 g

0.1

.984

.970

.958

.950

.947

.947

.947

.947

.947

.947 0.2

.969

.939

.915

.897

.888

.886

.886

.886

.886

.886 0.3

.953

.907

.869

.840

.822

.818

.818

.818

.818

.818 0.4

.936

.875

.82)

.778

.751

.740

.739

.739

.739

.739 0.5

.920

.841

.770

.713

.674

.653

.650

.650

.650

.650 0.6

.903

.806

.718

.644

.591

.559

.547

.547

.547

.547 0.7

.886

.770

.663

.572

.503

.457

.435

.431

.431

.431 0.8

.869

.734

.606

.496

.409

.349

.314

.301

.300

.300 0.9

.851

.696

.547

.416

.310

.233

.185

.161

.155

.155 Table A4.2 Calculated values of the flaw reduction factors in equations (7a) and (Ba), primary membrane plus bending stresses in a pipe with a circumferential flaw.

A.4.2 Limit on Membrane Stress

[ j u,

[ jo, WPO480.1b!081792 A-9

FLAW DEPTH FLAW LENGTH e/n RATIO 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0.1 0.99 0.98 0.97 0.96 0.95 0.94 0.93 0.92 0.91 0.90 0.2 0.98 0.96 0.94 0.92 0.90 0.88 0.86 0.84 0.82 0.80 0.3 0.97 0.94 0.91 0.88 0.85 0.82 0.79 0.76 0.73 0.70 0.4 0.96 0.92 0.88 0.84 0.80 0.76 0.72 0.68 0.64 0.60 0.5 0.95 0.90 0.85 0.80 0.75 0.70 0.65 0.60 0.55 0.50 0.6 0.94 0.88 0.82 0.76 0.70 0.64 0.58 0.52 0.46 0.40 0.7 0.93 0.86 0.79 0.72 0.65 0.58 0.51 0.44 0.37 0.30 0.8 0.92 0.84 0.76 0.68 0.60 0.52 0.44 0.36 0.28 0.20 0.9 0.91 0.82 0.73 0.64 0.55 0.46 0.37 0.28 0.19 0.10 Table A4.3 Calculated values of the flaw reduction factors in equation (9),

primary membrane stress in piping with a circumferential flaw.

I WP0480.1bl081792 A-10 I

A.5.0 DEVELOPMENT OF ACCEPTANCE CRITERIA FOR THE RESIDUAL HEAT EXCHANGER N0ZZLES l

[

]"'

The loads from Section 4 and appropriate class 2 allowable stresses are listed below:

Loading Case P, + P, ( ks i )

Z Allowable Stress i

o,(ksi)

Level A 12.3 1.449 1.5 S, = 24.3 Level B 12.3 1.449

1. 8 S, - M. 2 Level C 16.8 1.449 2.25 S, - 36.45 I

Level D 16.8 1.449 2.0 S, - 40.7 l

1 l

l

)

i I

1 WPO480:1b!081792 A-11

a/t O/tr Level A Level B Level C Level D 0.1 1.0 1.0 1.0 1.0 0.2 1.0 1.0 1.0 1.0 0.3 1.0 1.0 1.0 1.0 0.4 1.0 1.0 1.0 1.0 0.5 0.365 1.0 0.529 1.0 0.6 0.283 0.462 0.368 0.509 0.7 0.235 0.357 0.295 0.382 0.8 0.201 0.296 0.252 0.316 0.9 0.176 0.257 0.219 0.272

[ j u.

WPO480:1b!082092 A-13

S a

J.,

e

-7)o

+

r i

e i

F 1

1 l

I i

WPO480:1bl081792 A-12

P a.c.e Figure A5.1 Flaw Evaluation Chart for Residual Heat Exchanger Tube Side Inlet and Outlet Nozzles WPO480:1bl081792 A-14 I

e 4

A.

6.0 REFERENCES

(A1) ASME Boiler and Pressure Vessel Code,Section III, " Nuclear Power Plant Components".

1989 Edition with the 1991 Addenda used for specific references.

(A2) " Criteria of Section III of the ASME Boiler and Pressure Vessel Code for Nuclear Vessels", ASME, 1964.

(A3) ASME Boiler and Pressure Vessel Code,Section XI, " Rules for Inservice Inspection of Nuclear Power Plant Components".

1989 Edition with the 1991 Addenda used for specific references.

(A4)

J. P. Houstrup; Presentation to the ASME Section XI Task Group on Pipe Flaw Evaluation, in minutes, Nov.1988.

(A5) EPRI Report No. NP-4690SR, " Evaluation of Flaws in Austenitic Steel Piping", July, 1986.

i 1

i WPM 80:1blD81792 A-15

\\

4 m

APPENDIX B WELDING PROCEDURES AND SHOP TRAVELLERS BYRON AND BRAIDWOOD RESIDUAL HEAT EXCHANGERS WF0480.1bt081792 g.}

-9/14/76 Rev. 1) e '.,.c.. oa...c.o m p o r t.i s o s

.osEPH r

I' ape 1 of 4

-,n.-.........

WFLDING PP.0CEDURE 'sPECir t CATION VPS-9 SHIFLDED METAL-ARC WELDING STAlHLESS STEEL T0_STAlHLESS STEEL, Welding Frocess:

A.

All weldinn shall be done by the Shielded Metal-Arc Welding process (S."AU) in a cordance with ASME Section IX.

Base Metals:

A.

Each basa metal shell conform to a specification lis*.ed in Section IX groun P-B.

Filler l'etels and E!ectrodes:

A.

The electode shall conform to ASME specification number SFA 5.4, group F-5 and Weld Metal Analysis A-8 as indicated in Table A.

Shic1d1nc.0-es and Backino Rings:

A.

Shielding gas shall not be used.

B.

Gas backing, nonmetallic retalt.ers, or nonfusing metal retainers shall not be used.

Base Metal Thickness:

A.

This procedure covers groove welding of material thicknesses from 3/16" to j

1-1/2" and all size fillet wr.1ds on any materici thickness, 11 Preparailon of Base fiaterial:

A.

The edges or surfaces of the parts to be welded may be cut by machining, grinding, sawing, abrasive disc, plasma, or are cutting to conform essentially with Figure 1 and shall be cleaned by wire brushing or grinding as necessary.

B.

When plasma or are cutting is used, s11 oxides and scale shall be reinoved by machining or grinding away 1/16" cf material.

C.

Prior to welding, the surface shall be free of o11, grease and excessive amounts of scale or' rust.

Position:

A.

The welding may be done in the flat () G, IF), horizontal (2G, 2F), vertical (3G, 3F), overhead (4G, AF), or multiple (SG, 6G) position.

i 6

JOSEPH DAT CORPOR ATION

,8 $ - 3 cas wicas e =ne=s t ne a esea c,'os s Rev. 11

" ' " =

' ~ - ~ ' * "

  • Page 2 of 4 i

The vield progression for posi tions 3G, 3F, SG, and 6G shall be vpward.

B.

Preheat and Postheat Treatment:

A.

Preheat temperature - 50 F minimum.

B.

Interpass temperature - 350 F maximum.

C.

No postweld heat treatment requi.ed.

Electrical Characteristics:

A.

All welding shall be done with direct current, reversed polarity (base rnetal on negative side of line).

Joi nt Weld !,n,,q P rocedure:

i A.

The current and voltage shall be essentially as indicated in Table B.

B.

The wel ing sequence shall be essentially as shown in Figure I using stringer beads. The width of the bead shall not exceed 2-1/2 times the electrode diameter.

C.

Prior to welding the underside or second side of a groove, this side shall be Le dgivuyed to cleen metal by grinding, chipping, or arc gouging.

11 Arc gouging shall be followed by grinding away 1/16" of material.

D.

Starts and stops which show excess reinforcement or excessive depressions rhall be ground out prior to depositing next pass.

Cleanina:

A.

All slag or flux remaining on any bead of welding shall be removed before laying down the next successive bead of welding.

Interpass cleaning shall be by wire brushing, grinding, or sleg gun as necessary.

Defects:

A.

Any defects such as cracks, porosity, etc., which appear on the surface of any weld bead shall be removed by grinding, chippire, or are gouging prior to the deposition of the next successive weld bead.

Arc gouging shall be followed by grinding away 1/16" of material.

]

B.

Peening is prohibited.

Prepared by:

Reviewed by:

?, L i, d}a.-e. - P%L Jay hurphy l

Engineering Quality Control Manager

WPS-9 Rev.

11 JOSEPH DAT CORP 0 A Af t0N Page 3 of 4 O'," C.**,"c' C ' M

  • 1 ' L TABLE A The following material - electrode combinations may be used unless specified l

otherwise on the shop drawings.

l l

I BASE MATERIAL ELECTRODE For Group P-8 materials of the fol'owing types:

304 to 30h E308-15, E308-16 304L to 304L, 304 E308L-15, E308L-16 316 to 316, 304 E316-15, E316-16 316L to 316L, 316 E316L-15, E316L-16 317 to 317 E317-15, E317-16 317L to 317L, 317L E317L-15.

E317L-16 309 to 309 E309-15.

E309-16 l

l TABLE B MIN. TRAVEL ELECTRODE SIZE VOLTAGE RANGE AMPERAGE AANGE SPEED * (IPM) 3/32" 18-20 40-80 2-4 1/8" 20-22 80-120 4-7 5/32" 20-24 100-150 5-9 3/16" 20-24 130-190 6-11

  • As voltage and amperage are Jncreased, the minimum travel speed shall be increased through the range indicated.

9 0

t e

VPS-9 s s wic.6 e asias s a.POR ATION.

JOSEPH OAT COR Rev. Il

......e.io

~# ~ ' ~ **

Page 4 of 4 FlGURE 1 i

RECOM.MCtlDED JOINT CONFI GURATIONS AND WELDING BEAD SEQUENCES

  • A.

Material thicknesses of 3/8" and less :

)

60* w

~

1 iM O-M6" D

l i

. Material thicknesses greater than 3/8":

B.

GO*

O-Hs" q f

08/8*

60*

C.

All thicknesses for any size fillet:

e D

( l 4

/

g

  • 0ther configurations acceptable upon Engineering approval.

Ow 483 PROCEDURE QUALIFICAllDN RECORD tPOR)

(Sec OW 201.2.Section IX.1974 ASME Boiler and Pressure Vessel Code)

_ _ _ _ Company Name JOSEPH OAT CORPORATION Procedure Ovalification Record No.

PQR-g Date 1/11/77 WPS No.

9:

welding Process (es)

SMAW Types Mnual (Manual. Autorriatic Semi Aut.)

JOINTS (QW402)

BASE METALS (QW-403) 60 Material Spec.

SA-240

-304 Type or Grade 1

0

~

P No.

o P No.

O v-o '/e*

Thickness 3/4" go Diameter Groove Design Used Other FILLER METALS (QW404)

POSITION (QW405)

Weld Metal Analysis A No.

8 Position of Groove F1at 1C Sire of Electrode 5/32" weld progression Forehand Fillcr Metal F No.

5 (Uphill. Downhi!D SFA Specifiestion SFA 5.4 Other AWS Classification E-308-16 Other PREHEAT (QW406)

O "rchest Temp.

8iO F 0

Interpass Temp.

M 0 F ma x.

Other POSTWELD HEAT TREATMENT (QW407)

GAS (QW408)

Temperature None Type of Gas or Cases unn.

Time Composition of Gas Mixture

~~~

Other Other ELECTRICAL CHARACTERISTICS (QW409)

TECHNIQUE (QW410)

Current Direct String or Weave send Strinoer Polarity Reversed Oscillation Amps.

130

voit, 22-24 Multipan or Single Pass Multleass Travel Speed 10 lom (per side)

Other

  • ~-

Singic or Multiple Electrodes Sinole 7/74 Tow s to.m 49.a 7 4 mov he 04ptdened teens tese # s6st ordwe r>vut.. M S L. 4 7 si.. Na* vi ea. %v. tout?

PQR-9 02 483 (Back)

Shott 2 1/11/77 TENSILE TEST (QW 150)

I ULTIMATE ULTIMATE CHARACTER OF SPECIMEN TOTAL LOAD UNIT STRESS F AILURE i.

N O.

WIDTH THICKNESS AREA L B.

PSI LOCATION 9TI 1.569 0.731 1.147 97,250 84.790 Base Me ta l - liro ;c 9T2 1.569 0.724 1.136 96,000 84,510 Base Metal-Iko m 1

I i

GUIDED BEND TESTS (QW 160)

TYPE AND TYPE AND FIGU3E NO.

RESULT FIGURE NO.

RESULT QW-.6 2. ? (a.)

s i g _ g n r 4, 5 2,.,. n..

ne_ u o 9m

_ Side-Satisfarrnr" OW-462.2(a)

Side-Saricf artnev 0W459, m )

Ride-Satie'aerom TOUGHNESS : ESTS (QW 170)

SPECIMEN NOTCH NOTCH TEST IMPACT L ATER AL EXP.

DROP WElGHT NO.

LOCATION TYPE TEMP. VALUES

% SNE AR MILS BREAK NO BREAK j

Type of Test Deposit Analysis Other __

FILLET WELD TEST (QW 180)

Re. ult - Satisfactory Penetration into Parent Metal Yes. No Yes. No Type and Character of Failure

. Macro-Results' Welder's Narae John F.

Bnver Clock No.

72 Stamp No.

Tests conducted by:

PItt5. Te5t Lab Laboratory Test No.

Al2676 R.

D. Eavey per:

We certify that the statements in this record are correct and that the test welds were prepared. welded and tested in ascordance with the requirements of Section IX of the ASME Code.

Joseph Oa_, Corporation t

Signed (Manufacturer) l lI Date By

  • L M7v. dl~,

(Detail of record of tests are illustrative only and may be modif ed tb confo to e type and num-ber of tests required by the Code.)

Joseph Oat Corporation Job No.

J-2267 p 3-INITIAL DATE IllITI AL DATE Customer PE S T i tte.IlotlSE P.

O, i __546-AAZ(21515kDtiP O.C.

hO 3////f A.I.

E Ted['i Item No.

Dwg. No.

I EtJ G.

PPOD.

Code A5ftE lit Class 2 Tube Side 3 Shell Side Sheet I

of 7 W-Denotes Ucstinghouse llold Polnt.

130TE: Initials indicate acceptance.

Al= Denotes Code lloid Point.

HELD PROC.

I!OLD NDT PROC.

OAT INSP.

CUST.INSP.AUTII INSP ITEP DESCRIPTION Humber nov Number llev Sign Date Sign Date Sion Date i

NATERIAL RECEIPT I.

Shells 2.

lleads 3.

Norzles 4.

Tubes 5.

Tube Sheett' 6.

Itiscellaneous 11 SitELL FADRICATION l.

Cut and roll shell plates to Owg.

Dimension (1nspect).

2.

Veld shell long scams inside 22 background.

(LPT) 35 Al QC 100 3

Complete welding shell seams 22 (LPT)

(INSPECT) 35 QC 100 4.

Fit-up shell sections.

i Al

b i

  • Joli No. J-7267 Item No.

Sheet 2

of 7

6-3-75 Revision I WELD PROC.

IlOLD NDT PROC.

OAT INSP CUST INSP AUTH IllSP

^

ITEP DESCRIPTION Number Rev PT. Numher Rev Sign Date Sign Date Sign Date il SHELL FAB. (Continued) 5 Fit-up shell head and shell flange (Inspect) gg 6.

Weld all girths inside, backgrind 22 (LPT) 35 QC 100 i

l m

i 7.

Complete welding on girths 22 i

LPT Final welds then spot RT 35 QC 100

-QC 215

(

8.

Layout shell for nozzles i

l l

9 Fit-up nozzles to shell 10.

Weld nozzles to shell inside 22 II.- Cut holes for nozzles a Grind flush j

Inside - Backgrind outside - LPT QC 100 Al 12.

Complete welding nozzles outside -

LPT final nozzle welds,

QC 100

13. Fit-up and weld nozzle reinforcement pads (LPT) 22

-QC 100

14. Spot MT shell welds At 5f E RADI OGRAPF IC W

QC 215 READER St EET Fr R ACCFPTANCE l

i 15 Layout shell for seismic lugs -

Fit-up then weld (Inspect) LPT 22 QC 100 i

I L

Joli No. J-2267 Item No.

Sheet 1 of J l

6-3-75 Revision I INSP!

MELD PDOC.

IIOLD N DT P ROC.

OAT It!SP CUST INSP AUTil 3TEP DESCRIPTION Number Rev PT.

Number Rev Sion Date Sion Date Sion Date lIl CHANNEL ASSEMBLY 1.

Cut shell then roll to Dwg.

dimension - tack scam (Inspect) 2.

Weld seam inside 9

Backgrind (LPT) 40 QC 100 3

Complete Welding seam 9

(LPT) 30 QC 100 4

4.

Radiograph seam 100%

Al SEE RAD 101,RAPHl(

REA0! R W

QC 200 SHEl T FOR ACCEPl ANCE.

5.

Fit-up head and flange (Inspect)

At 6.

Weld Inside - backgrind - LPT 4

QC 100 7

Complete h5ad and flange welds (LPT) 4f QC 100 Al SEE RADi( GRAPHIC REAR ER 8.

Radiograph 100% head and flange W

QC 200 5t EET Ff R ACCE PTANCE 9

Layout channel for nozzles and couplings (Inspect) 10.

Fit-up nozzles weld inside then cut holes and grind flush (LPT) 9 Al QC 100

11. -Backgrind outside (LPT)

QC 100 12.

Co'mplete outside nozzle welds then LPT 9

QC 100

,_m.

..-+mm m-

- - ~

  • ~ *

. Job No. J-2267 Item No.

Sheet le of 7 6-1-74 Revisinn

IlOLD N DT P ROC.

DAT Itis P CUST INSP AUTil It:SP iTEP DESCRIPTION Number nov PT.

Number Rev Sion Date Sign Date Sion Date til CHANNEL ASSEMBLY 13 Fit-up and weld reinforcement pads (LPT) 9 QC 100 li. Fit-up pass partition plate and t

l Internal pipe support insp - weld 9

QC 100

15. Fit-up baseplate to skirt 22 Insp - weld - LPT

,,3 5 QC 100 l

16. Overlay skirt edge with S/S filler 19 17 Fit-up skirt to channel head Insp then weld - (LPT)

QC 100

18. Fit-up (Inspect) then weld elbows for channel drain (LPT) 9 QC 100 p

l S

l

\\

l

- Job' Ho. J-7767 Item No.

Sheet 5

of 7

<-1-7c Revision 1 WELD PROC.

IlOLD NDT PROC.

DAT IrlSP CUST IllSP AUTil Ills P iTEP DESCRIPTION Number Rev PT.

Number Rev Sion Date Sion Date Sion Date IV TUBE BUNDLE ASSEMBLY l

201 l.

Overlay tubesheet 202 2.

Nachine tubesheet to Dwg. Dim (LPT)

QC-100

.s.

i 3.

Layout for tube holes drill (Insp) 3 Layout and drill baf fles (Inspect) 1 5.

Deburr baffles and tubesheet 6.

Clean tubesheet, baffles, tie rods, and spacers.

QC-700 7.

Assemble tube bundle and Insert tubes 8.

Set tubes flush with tubesheet then weld 305

9. -Clean entire assembly QC-700 d

, Job No. J-2267 Item No.

Sheet 6 of 7

6-3-75 Revision 1 WELD PilOC.

IIOLD NDT PROC.

OAT INSP CUST INSP AUTH INSP STEP DESCRIPTION Number Rev PT. Number bev Sign Date Sion Date Sion Date V

FINAL ASSEMBLY I.

Take completed shell and clean QC-700 2.

Inspect shell Internal Al l

3.

Clean tube bundle QC-700 e

4.

Insert clean tube bundle in shell W

5.

Bolt up tubesheet to shell 6.

Diank off shcIl connections 7

Air test tu~be welds

/

Cage No.

W QC-500 8.

Drop air pressure and roll tubes IP-305 9.. Clean tube sheet and tubes QC-700 10.

Hydro shell per dwg. req's Al pressure observed.....

Gage No.

W QC-600 II.

LpT tube to tubesheet welds W

QC-Il0 1

12.

Clean tubes & tubesheet after i

penetrant exam QC-700 l

s

-- I i

i

Job No. J-nra Item No.

Sheet _ 7 of 7

Revision 1 6-1-75 WELD PROC.

IlOLD NDT PROC.

OAT INSP CUST INSP AUTil INSP STEP DESCRIPTION Number Rev PT. Number Rev Sign Date Sign Date Sign Date i

V FINAL ASSEMBLY (Continued)

13. Clean channel (Bonnet)

QC-700 t

i 14.

Inspect internal Sonnet Al w

i 6

15 soit up honnet to tubesheet l-16.

Blank off connections

17. Hydro tubeside Pressure observed....

Cage No.

QC-600

18. Dralt tube side and clean and I

dry shell s tubeside i

QC-700 19 Paint shell per drasing req's.

20.

Apply nameplate 21.

Skid 22.

Final Q.C. release w

Al t

9 I

_