ML20210E215

From kanterella
Jump to navigation Jump to search
Forwards Byron Unit 1 B1R09 ISI Summary Rept Spring 1999 Outage,980309-990424, in Compliance with Requirements of Article IWA-6000, Records & Repts of Section XI of ASME & P&PV,1989 Edition
ML20210E215
Person / Time
Site: Byron 
Issue date: 07/23/1999
From: Levis W
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20210E219 List:
References
BYRON-99-5074, NUDOCS 9907280160
Download: ML20210E215 (1)


Text

Comrnonwcahh lihwn Company li)ron Gracrating Stauon 4450 North German Church Road flyron, IL 61010 979 i Tel 815-244 54 41 July 23,1999 LTR: BYRON 99-5074 FILE: 3.11.0321 l

U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Byron Nuclear Power Station, Unit 1 Facility Operating License No. NPF-37 NRC Docket No. STN 50-454

SUBJECT:

Byron Station Unit 1 Inservice Inspection Report for Interval 2, Period 1, Outage 2 (81R09)

Please find attached a report for the Byron Station Unit 1 inservice inspections performed during Cycle 9 refueling outage B1R09 during March - April 1999. This report is being submitted in compliance with the requirements of Article IWA-6000,

" Records and Reports" of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code,1989 Edition.

If there are any questions conceming this correspondence, please contact Mr. B. J. Adams, Regulatory Assurance Manager, at (815) 234-5441, extension 2280.

s William Levis i l

Site Vice President

<I Byron Station,

WL/WGK/cb Attachment t.

0 cc:

Regional Administrator-NRC Region 111 NRC Senior Resident inspector-Byron Station OOhnnA 9907290160 990723 PDR ADOCK 05000454 G

PDR 1

ptegassurWW5074. doc A linicom Company