Category:INSPECTION REPORT
MONTHYEARIR 05000400/19990091999-04-0909 April 1999 Partially Withheld Insp Rept 50-400/99-09 on 990308-12 (Ref 10CFR73.21).No Violations Identified.Major Areas Inspected: Aspects of Licensee Plant Support Re Physical Security Program for Power Reactors ML20058P5341993-10-15015 October 1993 Partially Withheld Insp Rept 50-440/93-20 on 930913-17 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans,Protected & Vital Area Barriers,Detection Aids & Assessment Aids & Power Supply IR 05000400/19900251991-01-16016 January 1991 Insp Rept 50-400/90-25 on 901217-19.No Violations Noted. Major Areas Inspected:Simulator Exam Techniques,As Used in Licensed Operator Training Program IR 05000400/19890201989-09-28028 September 1989 Partially Withheld Insp Rept 50-400/89-20 on 890905-06 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Matl Control & Accountability of SNM Possessed & in Operation Under NRC License IR 05000400/19890111989-06-28028 June 1989 Partially Withheld Insp Rept 50-400/89-11 on 890515-19 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program & Vital Area Barriers.Noncited Violation Confirmed IR 05000400/19890011989-05-30030 May 1989 Errata to Insp Rept 50-400/89-01,consisting of Confirmatory Measurements Comparison & Criteria for Comparisons of Analytical Measurements IR 05000400/19890021989-03-16016 March 1989 Partially Withheld Insp Rept 50-400/89-02 on 890130-0203 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Inadequate Package Search at Protected Area Barrier.Major Areas Inspected:Core Insp Program & Followup Items IR 05000400/19880371988-10-0707 October 1988 Partially Withheld Insp Rept 50-400/88-37 on 880926-30 (Ref 10CFR2.790(d) & 73.21).Violations Noted.Major Areas Inspected:Physical Barriers - Vital Areas,Access Control Packages & Vehicles & Safeguards Contingency Plan ML20151M4751988-03-21021 March 1988 Partially Withheld Physical Security Insp Rept 50-400/88-05 on 880229-0304.Violation Noted.Major Areas Inspected: Security Plan & Implementing Procedures & Mgt Effectiveness. Details Withheld (Ref 10CFR2.790 & 73.21) ML20236B8851987-10-20020 October 1987 Performance Appraisal Nrc/State Contracts for Environ Monitoring on 871005-06.State Fulfilled All Requirements W/ Few Exceptions.Major Areas Inspected:Repts,Correspondence, day-to-day Contacts & Promptness in Resolution of Problems IR 05000400/19870331987-09-22022 September 1987 Partially Withheld Insp Rept 50-400/87-33 on 870831-0904 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Physical Security,Including Mgt Effectiveness Security Program,Records & Repts & Testing & Maint IR 05000400/19870171987-04-27027 April 1987 Partially Withheld Physical Security Insp Rept 50-400/87-17 on 870413-17 (Ref 10CFR2.790 & 73.21).No Violations Noted. Major Areas Inspected:Previous Enforcement Matters,Follow Up Items,Lers & Security Organization IR 05000400/19860941987-03-24024 March 1987 Insp Rept 50-400/86-94 on 861220-870120.No Violations Noted. Major Areas Inspected:Status of TMI Action Items,Const Matl Testing,Precritical Testing,Initial Criticality & Low Power Testing IR 05000400/19870081987-03-23023 March 1987 Partially Withheld Physical Security Insp Rept 50-400/87-08 on 870209-13 (Ref 10CFR2.790 & 73.21).Violation Noted: Failure to Implement Compensatory Measures IR 05000400/19870111987-03-11011 March 1987 Insp Rept 50-400/87-11 on 870226-0301.No Violations or Deviations Noted.Major Areas Inspected:Key Emergency Organizational Functions & Locations During Full Participation Emergency Preparedness Exercise IR 05000400/19870061987-03-10010 March 1987 Insp Rept 50-400/87-06 on 870120-0220.Violation Noted: Failure to Analyze Pump Test Data within Required Time Period IR 05000400/19870021987-02-19019 February 1987 Insp Rept 50-400/87-02 on 870107-29.No Violations or Deviations Noted.Major Areas Inspected:Startup Test Evaluation & Review,Witnessing of Loss of Offsite Power & Shutdown from Outside Control Room Tests IR 05000400/19860931987-02-18018 February 1987 Insp Rept 50-400/86-93 on 861215-17.Violation Noted:Failure to Adequately Review Procedure MST-I0322 Which Caused Improper Implementation of Procedure AP-20,in Violation of Tech Spec 6.8.1 IR 05000400/19870011987-02-12012 February 1987 Insp Rept 50-400/87-01 on 861203-870123.No Violations or Deviations Noted.Major Areas Inspected:Concerns Identified by Former Employee in Intervenor 861017 2.206 Petition IR 05000400/19870071987-02-11011 February 1987 Partially Withheld Insp Rept 50-400/87-07 on 870127-28 (Ref 10CFR2.790 & 73.21).Violation Noted:Failure to Provide Adequate Vital Area Barrier IR 05000400/19870031987-02-0505 February 1987 Insp Rept 50-400/87-03 on 870113-14.No Violation or Deviation Noted.Major Areas Inspected:Preoperational Insp of Radioactive Liquid & Gaseous Effluent Treatment Sys & Radiological Effluent Monitoring Sys IR 05000400/19860961987-01-29029 January 1987 Insp Rept 50-400/86-96 on 861230-870106.Violation Noted: Inadequate Test & Surveillance Procedures for Determination of RCS Leakage IR 05000400/19860951987-01-15015 January 1987 Partially Withheld Insp Rept 50-400/86-95 on 861230-31 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Uncompensated Vital Area Breach IR 05000400/19860911987-01-13013 January 1987 Insp Rept 50-400/86-91 on 861120-1220.No Violation or Deviation Noted.Major Areas Inspected:Status of TMI Action Items,Licensee Action on Previous Enforcement Matters, Unresolved Items & Tech Specs Verification ML20207J2671986-12-24024 December 1986 Insp Rept 50-400/86-76 on 860922-26,1006-10 & 1103-07. Violation Noted:Failure to Check Required Operating Parameters Prior to Securing Emergency Diesel Generator ML20207P9851986-12-22022 December 1986 Partially Withheld Security Insp Rept 50-400/86-92 on 861201-05 (Ref 10CFR2.790 & 73.21).Two Violations Noted. Major Areas Inspected:Plan/Procedures,Records/Repts, Barriers,Illumination,Access Controls & Detection Aids ML20207J4711986-12-22022 December 1986 Insp Rept 50-400/86-87 on 861020-1120.Violation Noted: Failure to Follow Procedure While Performing Tech Spec Verification.Unresolved Item Re Clearance Tagging of Safety Injection Sys Identified IR 05000400/19860921986-12-22022 December 1986 Partially Withheld Security Insp Rept 50-400/86-92 on 861201-05 (Ref 10CFR2.790 & 73.21).Two Violations Noted. Major Areas Inspected:Plan/Procedures,Records/Repts, Barriers,Illumination,Access Controls & Detection Aids ML20207K9281986-12-12012 December 1986 Insp Rept 50-400/86-89 on 861117-21.Violation Noted: Inadequate Housekeeping Controls Around Reactor Vessel During Initial Fuel Loading IR 05000400/19860891986-12-12012 December 1986 Insp Rept 50-400/86-89 on 861117-21.Violation Noted: Inadequate Housekeeping Controls Around Reactor Vessel During Initial Fuel Loading IR 05000400/19860901986-12-11011 December 1986 Partially Withheld Insp Rept 50-400/86-90 on 861112-13 (Ref 10CFR2.790 & 73.21).Violations Noted:Inadequate Compensatory Measures & Inadequate Documentation IR 05000400/19860231986-10-28028 October 1986 Partially Withheld Insp Rept 50-400/86-23 on 861007-09,16-17 & 19-21 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Locks & Keys,Detection Aids & Alarm Stations IR 05000400/19860681986-10-14014 October 1986 Insp Rept 50-400/86-68 on 860820-0920.Violations Noted:Qa Personnel Failed to Identify Necessary QC Hold Points on Wr&A 86-AUAK1 & QA Personnel Failed to Provide Adequate Review of Completed Wr&As 86-ABXA1,86-ABXA2 & 86-ABXA3 IR 05000400/19860641986-09-25025 September 1986 Partially Withheld Insp Rept 50-400/86-64 on 860818-22 (Ref 10CFR2.790(d) & 73.21).Major Areas Inspected:Assessment Aids,Locks,Keys & Combinations,Access Control of Personnel & Alarm Stations IR 05000400/19860671986-09-18018 September 1986 Insp Rept 50-400/86-67 on 860902-05.No Violation or Deviation Noted.Major Areas Inspected:Licensee Action on Previously Identified Insp Findings IR 05000400/19860571986-09-15015 September 1986 Insp Rept 50-400/86-57 on 860714-18.No Violations or Deviations Noted.Major Areas Inspected:Tech Spec Surveillance Requirements & Implementing Surveillance Test Procedures IR 05000400/19860621986-08-21021 August 1986 Insp Rept 50-400/86-62 on 860707-25.No Violation or Deviation Noted.Major Areas Inspected:Electrical Separation, Licensee Actions on Previous Enforcement Items & Licensee Identified Items IR 05000400/19860551986-08-0707 August 1986 Insp Rept 50-400/86-55 on 860620-0720.No Violations or Deviations Noted.Major Areas Inspected:Status of TMI Action Items,Ser Review & Followup,Emergency Svc Water Sys Status, Preoperational Testing & Previously Identified Items ML20202J7531986-07-11011 July 1986 Partially Withheld Preoperational Security Insp Rept 50-400/ 86-52 on 860618-19 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Security Program ML20203B9271986-07-0808 July 1986 Insp Rept 50-400/86-46 on 860520-0620.Violation Noted: Failure to Follow Administrative Procedure AP-X-02 & Housekeeping Procedures Re Trash & Debris.Deviation Noted: Failure to Review Shift Notes IR 05000400/19860361986-05-27027 May 1986 Partially Withheld Preoperational Security Insp Rept 50-400/86-36 on 860505-09 (Ref 10CFR2.790 & 73.21).No Violation or Deviation Noted.Major Areas Inspected:Lighting, Alarm Stations,Training & Safeguards Info IR 05000400/19860131986-04-0404 April 1986 Preoperational Insp Rept 50-400/86-13 on 860310-13.No Violation or Deviation Noted.Major Areas Inspected:Security Program & Organization,Security Audit & Physical Barriers. Details Withheld (Ref 10CFR2.790(d) & 73.21) IR 05000400/19860121986-03-10010 March 1986 Insp Rept 50-400/86-12 on 860221-24.No Violations or Deviations Noted.Major Areas Inspected:Reactor Containment Bldg Structural Integrity Test & Quality Records Pertaining to Pipe Vibration Tests IR 05000400/19840481985-09-25025 September 1985 Suppl 1 to Integrated Design Insp Rept 50-400/84-48 on 850722-24 at Ebasco Svcs,Inc.Potential Findings:Failure to Detect Use of Incorrect Assumptions in Calculations That Established Allowable Voltage Drop in Switchgear Circuits IR 05000401/20080091985-09-17017 September 1985 Insp Rept 50-458/85-29 on 850401-0809.Violation Noted: Failure to Assure Conformance of safety-related Structural Steel Welds W/Requirements of Aws D1.1-75 Structural Steel Welding Code IR 05000402/20060251985-08-0202 August 1985 Insp Rept 50-424/85-28 on 850402-0625.Deficiency Noted: Purchase of Superplasticizer as non-Q Matl,Problems Re Filing & Retrievability of Records & Lack of Timeliness in Issuing Deficiency Rept for Tensile Failures IR 05000400/19850231985-06-12012 June 1985 Insp Rept 50-400/85-23 on 850528-30.No Noncompliance Noted. Major Areas Inspected:Physical Security Plan Implementing Procedures,Security Organization & Physical Barriers.Details Withheld (Ref 10CFR2.790 & 73.21) IR 05000261/19850161985-05-24024 May 1985 Insp Repts 50-261/85-16,50-324/85-13,50-325/85-13 & 50-400/85-17 on 850506-09.No Violations or Deviations Noted. Major Areas Inspected:Preoperational Radiological Environ Monitoring Program at Shearon Harris & QA at Harris Lab IR 05000401/20060211985-01-28028 January 1985 Insp Repts 50-445/85-07 & 50-446/85-05 on 850401-0621. Violation Noted:Failure to Promptly Correct Identified Problem w/RTE-delta Potential Transformer Tiltout Subassemblies IR 05000400/19820201982-07-13013 July 1982 IE Insp Repts 50-400/82-20 & 50-401/82-20 on 820622-25.No Noncompliance Noted.Major Areas Inspected:Licensee Identified Items,Ie Bulletins & Circulars,Electrical Components & Sys & Inspector Followup Items 1999-04-09
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000400/19990091999-04-0909 April 1999 Partially Withheld Insp Rept 50-400/99-09 on 990308-12 (Ref 10CFR73.21).No Violations Identified.Major Areas Inspected: Aspects of Licensee Plant Support Re Physical Security Program for Power Reactors ML20058P5341993-10-15015 October 1993 Partially Withheld Insp Rept 50-440/93-20 on 930913-17 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans,Protected & Vital Area Barriers,Detection Aids & Assessment Aids & Power Supply IR 05000400/19900251991-01-16016 January 1991 Insp Rept 50-400/90-25 on 901217-19.No Violations Noted. Major Areas Inspected:Simulator Exam Techniques,As Used in Licensed Operator Training Program IR 05000400/19890201989-09-28028 September 1989 Partially Withheld Insp Rept 50-400/89-20 on 890905-06 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Matl Control & Accountability of SNM Possessed & in Operation Under NRC License IR 05000400/19890111989-06-28028 June 1989 Partially Withheld Insp Rept 50-400/89-11 on 890515-19 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program & Vital Area Barriers.Noncited Violation Confirmed IR 05000400/19890011989-05-30030 May 1989 Errata to Insp Rept 50-400/89-01,consisting of Confirmatory Measurements Comparison & Criteria for Comparisons of Analytical Measurements IR 05000400/19890021989-03-16016 March 1989 Partially Withheld Insp Rept 50-400/89-02 on 890130-0203 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Inadequate Package Search at Protected Area Barrier.Major Areas Inspected:Core Insp Program & Followup Items IR 05000400/19880371988-10-0707 October 1988 Partially Withheld Insp Rept 50-400/88-37 on 880926-30 (Ref 10CFR2.790(d) & 73.21).Violations Noted.Major Areas Inspected:Physical Barriers - Vital Areas,Access Control Packages & Vehicles & Safeguards Contingency Plan ML20151M4751988-03-21021 March 1988 Partially Withheld Physical Security Insp Rept 50-400/88-05 on 880229-0304.Violation Noted.Major Areas Inspected: Security Plan & Implementing Procedures & Mgt Effectiveness. Details Withheld (Ref 10CFR2.790 & 73.21) ML20236B8851987-10-20020 October 1987 Performance Appraisal Nrc/State Contracts for Environ Monitoring on 871005-06.State Fulfilled All Requirements W/ Few Exceptions.Major Areas Inspected:Repts,Correspondence, day-to-day Contacts & Promptness in Resolution of Problems IR 05000400/19870331987-09-22022 September 1987 Partially Withheld Insp Rept 50-400/87-33 on 870831-0904 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Physical Security,Including Mgt Effectiveness Security Program,Records & Repts & Testing & Maint IR 05000400/19870171987-04-27027 April 1987 Partially Withheld Physical Security Insp Rept 50-400/87-17 on 870413-17 (Ref 10CFR2.790 & 73.21).No Violations Noted. Major Areas Inspected:Previous Enforcement Matters,Follow Up Items,Lers & Security Organization IR 05000400/19860941987-03-24024 March 1987 Insp Rept 50-400/86-94 on 861220-870120.No Violations Noted. Major Areas Inspected:Status of TMI Action Items,Const Matl Testing,Precritical Testing,Initial Criticality & Low Power Testing IR 05000400/19870081987-03-23023 March 1987 Partially Withheld Physical Security Insp Rept 50-400/87-08 on 870209-13 (Ref 10CFR2.790 & 73.21).Violation Noted: Failure to Implement Compensatory Measures IR 05000400/19870111987-03-11011 March 1987 Insp Rept 50-400/87-11 on 870226-0301.No Violations or Deviations Noted.Major Areas Inspected:Key Emergency Organizational Functions & Locations During Full Participation Emergency Preparedness Exercise IR 05000400/19870061987-03-10010 March 1987 Insp Rept 50-400/87-06 on 870120-0220.Violation Noted: Failure to Analyze Pump Test Data within Required Time Period IR 05000400/19870021987-02-19019 February 1987 Insp Rept 50-400/87-02 on 870107-29.No Violations or Deviations Noted.Major Areas Inspected:Startup Test Evaluation & Review,Witnessing of Loss of Offsite Power & Shutdown from Outside Control Room Tests IR 05000400/19860931987-02-18018 February 1987 Insp Rept 50-400/86-93 on 861215-17.Violation Noted:Failure to Adequately Review Procedure MST-I0322 Which Caused Improper Implementation of Procedure AP-20,in Violation of Tech Spec 6.8.1 IR 05000400/19870011987-02-12012 February 1987 Insp Rept 50-400/87-01 on 861203-870123.No Violations or Deviations Noted.Major Areas Inspected:Concerns Identified by Former Employee in Intervenor 861017 2.206 Petition IR 05000400/19870071987-02-11011 February 1987 Partially Withheld Insp Rept 50-400/87-07 on 870127-28 (Ref 10CFR2.790 & 73.21).Violation Noted:Failure to Provide Adequate Vital Area Barrier IR 05000400/19870031987-02-0505 February 1987 Insp Rept 50-400/87-03 on 870113-14.No Violation or Deviation Noted.Major Areas Inspected:Preoperational Insp of Radioactive Liquid & Gaseous Effluent Treatment Sys & Radiological Effluent Monitoring Sys IR 05000400/19860961987-01-29029 January 1987 Insp Rept 50-400/86-96 on 861230-870106.Violation Noted: Inadequate Test & Surveillance Procedures for Determination of RCS Leakage IR 05000400/19860951987-01-15015 January 1987 Partially Withheld Insp Rept 50-400/86-95 on 861230-31 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Uncompensated Vital Area Breach IR 05000400/19860911987-01-13013 January 1987 Insp Rept 50-400/86-91 on 861120-1220.No Violation or Deviation Noted.Major Areas Inspected:Status of TMI Action Items,Licensee Action on Previous Enforcement Matters, Unresolved Items & Tech Specs Verification ML20207J2671986-12-24024 December 1986 Insp Rept 50-400/86-76 on 860922-26,1006-10 & 1103-07. Violation Noted:Failure to Check Required Operating Parameters Prior to Securing Emergency Diesel Generator ML20207P9851986-12-22022 December 1986 Partially Withheld Security Insp Rept 50-400/86-92 on 861201-05 (Ref 10CFR2.790 & 73.21).Two Violations Noted. Major Areas Inspected:Plan/Procedures,Records/Repts, Barriers,Illumination,Access Controls & Detection Aids ML20207J4711986-12-22022 December 1986 Insp Rept 50-400/86-87 on 861020-1120.Violation Noted: Failure to Follow Procedure While Performing Tech Spec Verification.Unresolved Item Re Clearance Tagging of Safety Injection Sys Identified IR 05000400/19860921986-12-22022 December 1986 Partially Withheld Security Insp Rept 50-400/86-92 on 861201-05 (Ref 10CFR2.790 & 73.21).Two Violations Noted. Major Areas Inspected:Plan/Procedures,Records/Repts, Barriers,Illumination,Access Controls & Detection Aids ML20207K9281986-12-12012 December 1986 Insp Rept 50-400/86-89 on 861117-21.Violation Noted: Inadequate Housekeeping Controls Around Reactor Vessel During Initial Fuel Loading IR 05000400/19860891986-12-12012 December 1986 Insp Rept 50-400/86-89 on 861117-21.Violation Noted: Inadequate Housekeeping Controls Around Reactor Vessel During Initial Fuel Loading IR 05000400/19860901986-12-11011 December 1986 Partially Withheld Insp Rept 50-400/86-90 on 861112-13 (Ref 10CFR2.790 & 73.21).Violations Noted:Inadequate Compensatory Measures & Inadequate Documentation IR 05000400/19860231986-10-28028 October 1986 Partially Withheld Insp Rept 50-400/86-23 on 861007-09,16-17 & 19-21 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Locks & Keys,Detection Aids & Alarm Stations IR 05000400/19860681986-10-14014 October 1986 Insp Rept 50-400/86-68 on 860820-0920.Violations Noted:Qa Personnel Failed to Identify Necessary QC Hold Points on Wr&A 86-AUAK1 & QA Personnel Failed to Provide Adequate Review of Completed Wr&As 86-ABXA1,86-ABXA2 & 86-ABXA3 IR 05000400/19860641986-09-25025 September 1986 Partially Withheld Insp Rept 50-400/86-64 on 860818-22 (Ref 10CFR2.790(d) & 73.21).Major Areas Inspected:Assessment Aids,Locks,Keys & Combinations,Access Control of Personnel & Alarm Stations IR 05000400/19860671986-09-18018 September 1986 Insp Rept 50-400/86-67 on 860902-05.No Violation or Deviation Noted.Major Areas Inspected:Licensee Action on Previously Identified Insp Findings IR 05000400/19860571986-09-15015 September 1986 Insp Rept 50-400/86-57 on 860714-18.No Violations or Deviations Noted.Major Areas Inspected:Tech Spec Surveillance Requirements & Implementing Surveillance Test Procedures IR 05000400/19860621986-08-21021 August 1986 Insp Rept 50-400/86-62 on 860707-25.No Violation or Deviation Noted.Major Areas Inspected:Electrical Separation, Licensee Actions on Previous Enforcement Items & Licensee Identified Items IR 05000400/19860551986-08-0707 August 1986 Insp Rept 50-400/86-55 on 860620-0720.No Violations or Deviations Noted.Major Areas Inspected:Status of TMI Action Items,Ser Review & Followup,Emergency Svc Water Sys Status, Preoperational Testing & Previously Identified Items ML20202J7531986-07-11011 July 1986 Partially Withheld Preoperational Security Insp Rept 50-400/ 86-52 on 860618-19 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Security Program ML20203B9271986-07-0808 July 1986 Insp Rept 50-400/86-46 on 860520-0620.Violation Noted: Failure to Follow Administrative Procedure AP-X-02 & Housekeeping Procedures Re Trash & Debris.Deviation Noted: Failure to Review Shift Notes IR 05000400/19860361986-05-27027 May 1986 Partially Withheld Preoperational Security Insp Rept 50-400/86-36 on 860505-09 (Ref 10CFR2.790 & 73.21).No Violation or Deviation Noted.Major Areas Inspected:Lighting, Alarm Stations,Training & Safeguards Info IR 05000400/19860131986-04-0404 April 1986 Preoperational Insp Rept 50-400/86-13 on 860310-13.No Violation or Deviation Noted.Major Areas Inspected:Security Program & Organization,Security Audit & Physical Barriers. Details Withheld (Ref 10CFR2.790(d) & 73.21) IR 05000400/19860121986-03-10010 March 1986 Insp Rept 50-400/86-12 on 860221-24.No Violations or Deviations Noted.Major Areas Inspected:Reactor Containment Bldg Structural Integrity Test & Quality Records Pertaining to Pipe Vibration Tests IR 05000400/19840481985-09-25025 September 1985 Suppl 1 to Integrated Design Insp Rept 50-400/84-48 on 850722-24 at Ebasco Svcs,Inc.Potential Findings:Failure to Detect Use of Incorrect Assumptions in Calculations That Established Allowable Voltage Drop in Switchgear Circuits IR 05000401/20080091985-09-17017 September 1985 Insp Rept 50-458/85-29 on 850401-0809.Violation Noted: Failure to Assure Conformance of safety-related Structural Steel Welds W/Requirements of Aws D1.1-75 Structural Steel Welding Code IR 05000402/20060251985-08-0202 August 1985 Insp Rept 50-424/85-28 on 850402-0625.Deficiency Noted: Purchase of Superplasticizer as non-Q Matl,Problems Re Filing & Retrievability of Records & Lack of Timeliness in Issuing Deficiency Rept for Tensile Failures IR 05000400/19850231985-06-12012 June 1985 Insp Rept 50-400/85-23 on 850528-30.No Noncompliance Noted. Major Areas Inspected:Physical Security Plan Implementing Procedures,Security Organization & Physical Barriers.Details Withheld (Ref 10CFR2.790 & 73.21) IR 05000261/19850161985-05-24024 May 1985 Insp Repts 50-261/85-16,50-324/85-13,50-325/85-13 & 50-400/85-17 on 850506-09.No Violations or Deviations Noted. Major Areas Inspected:Preoperational Radiological Environ Monitoring Program at Shearon Harris & QA at Harris Lab IR 05000401/20060211985-01-28028 January 1985 Insp Repts 50-445/85-07 & 50-446/85-05 on 850401-0621. Violation Noted:Failure to Promptly Correct Identified Problem w/RTE-delta Potential Transformer Tiltout Subassemblies IR 05000400/19820201982-07-13013 July 1982 IE Insp Repts 50-400/82-20 & 50-401/82-20 on 820622-25.No Noncompliance Noted.Major Areas Inspected:Licensee Identified Items,Ie Bulletins & Circulars,Electrical Components & Sys & Inspector Followup Items 1999-04-09
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000400/19990091999-04-0909 April 1999 Partially Withheld Insp Rept 50-400/99-09 on 990308-12 (Ref 10CFR73.21).No Violations Identified.Major Areas Inspected: Aspects of Licensee Plant Support Re Physical Security Program for Power Reactors ML20058P5341993-10-15015 October 1993 Partially Withheld Insp Rept 50-440/93-20 on 930913-17 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans,Protected & Vital Area Barriers,Detection Aids & Assessment Aids & Power Supply IR 05000400/19900251991-01-16016 January 1991 Insp Rept 50-400/90-25 on 901217-19.No Violations Noted. Major Areas Inspected:Simulator Exam Techniques,As Used in Licensed Operator Training Program IR 05000400/19890201989-09-28028 September 1989 Partially Withheld Insp Rept 50-400/89-20 on 890905-06 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Matl Control & Accountability of SNM Possessed & in Operation Under NRC License IR 05000400/19890111989-06-28028 June 1989 Partially Withheld Insp Rept 50-400/89-11 on 890515-19 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program & Vital Area Barriers.Noncited Violation Confirmed IR 05000400/19890011989-05-30030 May 1989 Errata to Insp Rept 50-400/89-01,consisting of Confirmatory Measurements Comparison & Criteria for Comparisons of Analytical Measurements IR 05000400/19890021989-03-16016 March 1989 Partially Withheld Insp Rept 50-400/89-02 on 890130-0203 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Inadequate Package Search at Protected Area Barrier.Major Areas Inspected:Core Insp Program & Followup Items IR 05000400/19880371988-10-0707 October 1988 Partially Withheld Insp Rept 50-400/88-37 on 880926-30 (Ref 10CFR2.790(d) & 73.21).Violations Noted.Major Areas Inspected:Physical Barriers - Vital Areas,Access Control Packages & Vehicles & Safeguards Contingency Plan ML20151M4751988-03-21021 March 1988 Partially Withheld Physical Security Insp Rept 50-400/88-05 on 880229-0304.Violation Noted.Major Areas Inspected: Security Plan & Implementing Procedures & Mgt Effectiveness. Details Withheld (Ref 10CFR2.790 & 73.21) ML20236B8851987-10-20020 October 1987 Performance Appraisal Nrc/State Contracts for Environ Monitoring on 871005-06.State Fulfilled All Requirements W/ Few Exceptions.Major Areas Inspected:Repts,Correspondence, day-to-day Contacts & Promptness in Resolution of Problems IR 05000400/19870331987-09-22022 September 1987 Partially Withheld Insp Rept 50-400/87-33 on 870831-0904 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Physical Security,Including Mgt Effectiveness Security Program,Records & Repts & Testing & Maint IR 05000400/19870171987-04-27027 April 1987 Partially Withheld Physical Security Insp Rept 50-400/87-17 on 870413-17 (Ref 10CFR2.790 & 73.21).No Violations Noted. Major Areas Inspected:Previous Enforcement Matters,Follow Up Items,Lers & Security Organization IR 05000400/19860941987-03-24024 March 1987 Insp Rept 50-400/86-94 on 861220-870120.No Violations Noted. Major Areas Inspected:Status of TMI Action Items,Const Matl Testing,Precritical Testing,Initial Criticality & Low Power Testing IR 05000400/19870081987-03-23023 March 1987 Partially Withheld Physical Security Insp Rept 50-400/87-08 on 870209-13 (Ref 10CFR2.790 & 73.21).Violation Noted: Failure to Implement Compensatory Measures IR 05000400/19870111987-03-11011 March 1987 Insp Rept 50-400/87-11 on 870226-0301.No Violations or Deviations Noted.Major Areas Inspected:Key Emergency Organizational Functions & Locations During Full Participation Emergency Preparedness Exercise IR 05000400/19870061987-03-10010 March 1987 Insp Rept 50-400/87-06 on 870120-0220.Violation Noted: Failure to Analyze Pump Test Data within Required Time Period IR 05000400/19870021987-02-19019 February 1987 Insp Rept 50-400/87-02 on 870107-29.No Violations or Deviations Noted.Major Areas Inspected:Startup Test Evaluation & Review,Witnessing of Loss of Offsite Power & Shutdown from Outside Control Room Tests IR 05000400/19860931987-02-18018 February 1987 Insp Rept 50-400/86-93 on 861215-17.Violation Noted:Failure to Adequately Review Procedure MST-I0322 Which Caused Improper Implementation of Procedure AP-20,in Violation of Tech Spec 6.8.1 IR 05000400/19870011987-02-12012 February 1987 Insp Rept 50-400/87-01 on 861203-870123.No Violations or Deviations Noted.Major Areas Inspected:Concerns Identified by Former Employee in Intervenor 861017 2.206 Petition IR 05000400/19870071987-02-11011 February 1987 Partially Withheld Insp Rept 50-400/87-07 on 870127-28 (Ref 10CFR2.790 & 73.21).Violation Noted:Failure to Provide Adequate Vital Area Barrier IR 05000400/19870031987-02-0505 February 1987 Insp Rept 50-400/87-03 on 870113-14.No Violation or Deviation Noted.Major Areas Inspected:Preoperational Insp of Radioactive Liquid & Gaseous Effluent Treatment Sys & Radiological Effluent Monitoring Sys IR 05000400/19860961987-01-29029 January 1987 Insp Rept 50-400/86-96 on 861230-870106.Violation Noted: Inadequate Test & Surveillance Procedures for Determination of RCS Leakage IR 05000400/19860951987-01-15015 January 1987 Partially Withheld Insp Rept 50-400/86-95 on 861230-31 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Uncompensated Vital Area Breach IR 05000400/19860911987-01-13013 January 1987 Insp Rept 50-400/86-91 on 861120-1220.No Violation or Deviation Noted.Major Areas Inspected:Status of TMI Action Items,Licensee Action on Previous Enforcement Matters, Unresolved Items & Tech Specs Verification ML20207J2671986-12-24024 December 1986 Insp Rept 50-400/86-76 on 860922-26,1006-10 & 1103-07. Violation Noted:Failure to Check Required Operating Parameters Prior to Securing Emergency Diesel Generator ML20207P9851986-12-22022 December 1986 Partially Withheld Security Insp Rept 50-400/86-92 on 861201-05 (Ref 10CFR2.790 & 73.21).Two Violations Noted. Major Areas Inspected:Plan/Procedures,Records/Repts, Barriers,Illumination,Access Controls & Detection Aids ML20207J4711986-12-22022 December 1986 Insp Rept 50-400/86-87 on 861020-1120.Violation Noted: Failure to Follow Procedure While Performing Tech Spec Verification.Unresolved Item Re Clearance Tagging of Safety Injection Sys Identified IR 05000400/19860921986-12-22022 December 1986 Partially Withheld Security Insp Rept 50-400/86-92 on 861201-05 (Ref 10CFR2.790 & 73.21).Two Violations Noted. Major Areas Inspected:Plan/Procedures,Records/Repts, Barriers,Illumination,Access Controls & Detection Aids ML20207K9281986-12-12012 December 1986 Insp Rept 50-400/86-89 on 861117-21.Violation Noted: Inadequate Housekeeping Controls Around Reactor Vessel During Initial Fuel Loading IR 05000400/19860891986-12-12012 December 1986 Insp Rept 50-400/86-89 on 861117-21.Violation Noted: Inadequate Housekeeping Controls Around Reactor Vessel During Initial Fuel Loading IR 05000400/19860901986-12-11011 December 1986 Partially Withheld Insp Rept 50-400/86-90 on 861112-13 (Ref 10CFR2.790 & 73.21).Violations Noted:Inadequate Compensatory Measures & Inadequate Documentation IR 05000400/19860231986-10-28028 October 1986 Partially Withheld Insp Rept 50-400/86-23 on 861007-09,16-17 & 19-21 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Locks & Keys,Detection Aids & Alarm Stations IR 05000400/19860681986-10-14014 October 1986 Insp Rept 50-400/86-68 on 860820-0920.Violations Noted:Qa Personnel Failed to Identify Necessary QC Hold Points on Wr&A 86-AUAK1 & QA Personnel Failed to Provide Adequate Review of Completed Wr&As 86-ABXA1,86-ABXA2 & 86-ABXA3 IR 05000400/19860641986-09-25025 September 1986 Partially Withheld Insp Rept 50-400/86-64 on 860818-22 (Ref 10CFR2.790(d) & 73.21).Major Areas Inspected:Assessment Aids,Locks,Keys & Combinations,Access Control of Personnel & Alarm Stations IR 05000400/19860671986-09-18018 September 1986 Insp Rept 50-400/86-67 on 860902-05.No Violation or Deviation Noted.Major Areas Inspected:Licensee Action on Previously Identified Insp Findings IR 05000400/19860571986-09-15015 September 1986 Insp Rept 50-400/86-57 on 860714-18.No Violations or Deviations Noted.Major Areas Inspected:Tech Spec Surveillance Requirements & Implementing Surveillance Test Procedures IR 05000400/19860621986-08-21021 August 1986 Insp Rept 50-400/86-62 on 860707-25.No Violation or Deviation Noted.Major Areas Inspected:Electrical Separation, Licensee Actions on Previous Enforcement Items & Licensee Identified Items IR 05000400/19860551986-08-0707 August 1986 Insp Rept 50-400/86-55 on 860620-0720.No Violations or Deviations Noted.Major Areas Inspected:Status of TMI Action Items,Ser Review & Followup,Emergency Svc Water Sys Status, Preoperational Testing & Previously Identified Items ML20202J7531986-07-11011 July 1986 Partially Withheld Preoperational Security Insp Rept 50-400/ 86-52 on 860618-19 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Security Program ML20203B9271986-07-0808 July 1986 Insp Rept 50-400/86-46 on 860520-0620.Violation Noted: Failure to Follow Administrative Procedure AP-X-02 & Housekeeping Procedures Re Trash & Debris.Deviation Noted: Failure to Review Shift Notes IR 05000400/19860361986-05-27027 May 1986 Partially Withheld Preoperational Security Insp Rept 50-400/86-36 on 860505-09 (Ref 10CFR2.790 & 73.21).No Violation or Deviation Noted.Major Areas Inspected:Lighting, Alarm Stations,Training & Safeguards Info IR 05000400/19860131986-04-0404 April 1986 Preoperational Insp Rept 50-400/86-13 on 860310-13.No Violation or Deviation Noted.Major Areas Inspected:Security Program & Organization,Security Audit & Physical Barriers. Details Withheld (Ref 10CFR2.790(d) & 73.21) IR 05000400/19860121986-03-10010 March 1986 Insp Rept 50-400/86-12 on 860221-24.No Violations or Deviations Noted.Major Areas Inspected:Reactor Containment Bldg Structural Integrity Test & Quality Records Pertaining to Pipe Vibration Tests IR 05000400/19840481985-09-25025 September 1985 Suppl 1 to Integrated Design Insp Rept 50-400/84-48 on 850722-24 at Ebasco Svcs,Inc.Potential Findings:Failure to Detect Use of Incorrect Assumptions in Calculations That Established Allowable Voltage Drop in Switchgear Circuits IR 05000401/20080091985-09-17017 September 1985 Insp Rept 50-458/85-29 on 850401-0809.Violation Noted: Failure to Assure Conformance of safety-related Structural Steel Welds W/Requirements of Aws D1.1-75 Structural Steel Welding Code IR 05000402/20060251985-08-0202 August 1985 Insp Rept 50-424/85-28 on 850402-0625.Deficiency Noted: Purchase of Superplasticizer as non-Q Matl,Problems Re Filing & Retrievability of Records & Lack of Timeliness in Issuing Deficiency Rept for Tensile Failures IR 05000400/19850231985-06-12012 June 1985 Insp Rept 50-400/85-23 on 850528-30.No Noncompliance Noted. Major Areas Inspected:Physical Security Plan Implementing Procedures,Security Organization & Physical Barriers.Details Withheld (Ref 10CFR2.790 & 73.21) IR 05000261/19850161985-05-24024 May 1985 Insp Repts 50-261/85-16,50-324/85-13,50-325/85-13 & 50-400/85-17 on 850506-09.No Violations or Deviations Noted. Major Areas Inspected:Preoperational Radiological Environ Monitoring Program at Shearon Harris & QA at Harris Lab IR 05000401/20060211985-01-28028 January 1985 Insp Repts 50-445/85-07 & 50-446/85-05 on 850401-0621. Violation Noted:Failure to Promptly Correct Identified Problem w/RTE-delta Potential Transformer Tiltout Subassemblies IR 05000400/19820201982-07-13013 July 1982 IE Insp Repts 50-400/82-20 & 50-401/82-20 on 820622-25.No Noncompliance Noted.Major Areas Inspected:Licensee Identified Items,Ie Bulletins & Circulars,Electrical Components & Sys & Inspector Followup Items 1999-04-09
[Table view] Category:UTILITY
MONTHYEARIR 05000400/19890201989-09-28028 September 1989 Partially Withheld Insp Rept 50-400/89-20 on 890905-06 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Matl Control & Accountability of SNM Possessed & in Operation Under NRC License IR 05000400/19890111989-06-28028 June 1989 Partially Withheld Insp Rept 50-400/89-11 on 890515-19 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program & Vital Area Barriers.Noncited Violation Confirmed IR 05000400/19890011989-05-30030 May 1989 Errata to Insp Rept 50-400/89-01,consisting of Confirmatory Measurements Comparison & Criteria for Comparisons of Analytical Measurements IR 05000400/19890021989-03-16016 March 1989 Partially Withheld Insp Rept 50-400/89-02 on 890130-0203 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Inadequate Package Search at Protected Area Barrier.Major Areas Inspected:Core Insp Program & Followup Items IR 05000400/19880371988-10-0707 October 1988 Partially Withheld Insp Rept 50-400/88-37 on 880926-30 (Ref 10CFR2.790(d) & 73.21).Violations Noted.Major Areas Inspected:Physical Barriers - Vital Areas,Access Control Packages & Vehicles & Safeguards Contingency Plan ML20151M4751988-03-21021 March 1988 Partially Withheld Physical Security Insp Rept 50-400/88-05 on 880229-0304.Violation Noted.Major Areas Inspected: Security Plan & Implementing Procedures & Mgt Effectiveness. Details Withheld (Ref 10CFR2.790 & 73.21) IR 05000400/19870331987-09-22022 September 1987 Partially Withheld Insp Rept 50-400/87-33 on 870831-0904 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Physical Security,Including Mgt Effectiveness Security Program,Records & Repts & Testing & Maint IR 05000400/19870171987-04-27027 April 1987 Partially Withheld Physical Security Insp Rept 50-400/87-17 on 870413-17 (Ref 10CFR2.790 & 73.21).No Violations Noted. Major Areas Inspected:Previous Enforcement Matters,Follow Up Items,Lers & Security Organization IR 05000400/19860941987-03-24024 March 1987 Insp Rept 50-400/86-94 on 861220-870120.No Violations Noted. Major Areas Inspected:Status of TMI Action Items,Const Matl Testing,Precritical Testing,Initial Criticality & Low Power Testing IR 05000400/19870081987-03-23023 March 1987 Partially Withheld Physical Security Insp Rept 50-400/87-08 on 870209-13 (Ref 10CFR2.790 & 73.21).Violation Noted: Failure to Implement Compensatory Measures IR 05000400/19870111987-03-11011 March 1987 Insp Rept 50-400/87-11 on 870226-0301.No Violations or Deviations Noted.Major Areas Inspected:Key Emergency Organizational Functions & Locations During Full Participation Emergency Preparedness Exercise IR 05000400/19870061987-03-10010 March 1987 Insp Rept 50-400/87-06 on 870120-0220.Violation Noted: Failure to Analyze Pump Test Data within Required Time Period IR 05000400/19870021987-02-19019 February 1987 Insp Rept 50-400/87-02 on 870107-29.No Violations or Deviations Noted.Major Areas Inspected:Startup Test Evaluation & Review,Witnessing of Loss of Offsite Power & Shutdown from Outside Control Room Tests IR 05000400/19860931987-02-18018 February 1987 Insp Rept 50-400/86-93 on 861215-17.Violation Noted:Failure to Adequately Review Procedure MST-I0322 Which Caused Improper Implementation of Procedure AP-20,in Violation of Tech Spec 6.8.1 IR 05000400/19870011987-02-12012 February 1987 Insp Rept 50-400/87-01 on 861203-870123.No Violations or Deviations Noted.Major Areas Inspected:Concerns Identified by Former Employee in Intervenor 861017 2.206 Petition IR 05000400/19870071987-02-11011 February 1987 Partially Withheld Insp Rept 50-400/87-07 on 870127-28 (Ref 10CFR2.790 & 73.21).Violation Noted:Failure to Provide Adequate Vital Area Barrier IR 05000400/19870031987-02-0505 February 1987 Insp Rept 50-400/87-03 on 870113-14.No Violation or Deviation Noted.Major Areas Inspected:Preoperational Insp of Radioactive Liquid & Gaseous Effluent Treatment Sys & Radiological Effluent Monitoring Sys IR 05000400/19860961987-01-29029 January 1987 Insp Rept 50-400/86-96 on 861230-870106.Violation Noted: Inadequate Test & Surveillance Procedures for Determination of RCS Leakage IR 05000400/19860951987-01-15015 January 1987 Partially Withheld Insp Rept 50-400/86-95 on 861230-31 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Uncompensated Vital Area Breach IR 05000400/19860911987-01-13013 January 1987 Insp Rept 50-400/86-91 on 861120-1220.No Violation or Deviation Noted.Major Areas Inspected:Status of TMI Action Items,Licensee Action on Previous Enforcement Matters, Unresolved Items & Tech Specs Verification ML20207J2671986-12-24024 December 1986 Insp Rept 50-400/86-76 on 860922-26,1006-10 & 1103-07. Violation Noted:Failure to Check Required Operating Parameters Prior to Securing Emergency Diesel Generator ML20207J4711986-12-22022 December 1986 Insp Rept 50-400/86-87 on 861020-1120.Violation Noted: Failure to Follow Procedure While Performing Tech Spec Verification.Unresolved Item Re Clearance Tagging of Safety Injection Sys Identified IR 05000400/19860921986-12-22022 December 1986 Partially Withheld Security Insp Rept 50-400/86-92 on 861201-05 (Ref 10CFR2.790 & 73.21).Two Violations Noted. Major Areas Inspected:Plan/Procedures,Records/Repts, Barriers,Illumination,Access Controls & Detection Aids ML20207P9851986-12-22022 December 1986 Partially Withheld Security Insp Rept 50-400/86-92 on 861201-05 (Ref 10CFR2.790 & 73.21).Two Violations Noted. Major Areas Inspected:Plan/Procedures,Records/Repts, Barriers,Illumination,Access Controls & Detection Aids ML20207K9281986-12-12012 December 1986 Insp Rept 50-400/86-89 on 861117-21.Violation Noted: Inadequate Housekeeping Controls Around Reactor Vessel During Initial Fuel Loading IR 05000400/19860891986-12-12012 December 1986 Insp Rept 50-400/86-89 on 861117-21.Violation Noted: Inadequate Housekeeping Controls Around Reactor Vessel During Initial Fuel Loading IR 05000400/19860901986-12-11011 December 1986 Partially Withheld Insp Rept 50-400/86-90 on 861112-13 (Ref 10CFR2.790 & 73.21).Violations Noted:Inadequate Compensatory Measures & Inadequate Documentation IR 05000400/19860231986-10-28028 October 1986 Partially Withheld Insp Rept 50-400/86-23 on 861007-09,16-17 & 19-21 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Locks & Keys,Detection Aids & Alarm Stations IR 05000400/19860681986-10-14014 October 1986 Insp Rept 50-400/86-68 on 860820-0920.Violations Noted:Qa Personnel Failed to Identify Necessary QC Hold Points on Wr&A 86-AUAK1 & QA Personnel Failed to Provide Adequate Review of Completed Wr&As 86-ABXA1,86-ABXA2 & 86-ABXA3 IR 05000400/19860641986-09-25025 September 1986 Partially Withheld Insp Rept 50-400/86-64 on 860818-22 (Ref 10CFR2.790(d) & 73.21).Major Areas Inspected:Assessment Aids,Locks,Keys & Combinations,Access Control of Personnel & Alarm Stations IR 05000400/19860671986-09-18018 September 1986 Insp Rept 50-400/86-67 on 860902-05.No Violation or Deviation Noted.Major Areas Inspected:Licensee Action on Previously Identified Insp Findings IR 05000400/19860571986-09-15015 September 1986 Insp Rept 50-400/86-57 on 860714-18.No Violations or Deviations Noted.Major Areas Inspected:Tech Spec Surveillance Requirements & Implementing Surveillance Test Procedures IR 05000400/19860621986-08-21021 August 1986 Insp Rept 50-400/86-62 on 860707-25.No Violation or Deviation Noted.Major Areas Inspected:Electrical Separation, Licensee Actions on Previous Enforcement Items & Licensee Identified Items IR 05000400/19860551986-08-0707 August 1986 Insp Rept 50-400/86-55 on 860620-0720.No Violations or Deviations Noted.Major Areas Inspected:Status of TMI Action Items,Ser Review & Followup,Emergency Svc Water Sys Status, Preoperational Testing & Previously Identified Items ML20202J7531986-07-11011 July 1986 Partially Withheld Preoperational Security Insp Rept 50-400/ 86-52 on 860618-19 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Security Program ML20203B9271986-07-0808 July 1986 Insp Rept 50-400/86-46 on 860520-0620.Violation Noted: Failure to Follow Administrative Procedure AP-X-02 & Housekeeping Procedures Re Trash & Debris.Deviation Noted: Failure to Review Shift Notes IR 05000400/19860361986-05-27027 May 1986 Partially Withheld Preoperational Security Insp Rept 50-400/86-36 on 860505-09 (Ref 10CFR2.790 & 73.21).No Violation or Deviation Noted.Major Areas Inspected:Lighting, Alarm Stations,Training & Safeguards Info IR 05000400/19860131986-04-0404 April 1986 Preoperational Insp Rept 50-400/86-13 on 860310-13.No Violation or Deviation Noted.Major Areas Inspected:Security Program & Organization,Security Audit & Physical Barriers. Details Withheld (Ref 10CFR2.790(d) & 73.21) IR 05000400/19860121986-03-10010 March 1986 Insp Rept 50-400/86-12 on 860221-24.No Violations or Deviations Noted.Major Areas Inspected:Reactor Containment Bldg Structural Integrity Test & Quality Records Pertaining to Pipe Vibration Tests IR 05000401/20080091985-09-17017 September 1985 Insp Rept 50-458/85-29 on 850401-0809.Violation Noted: Failure to Assure Conformance of safety-related Structural Steel Welds W/Requirements of Aws D1.1-75 Structural Steel Welding Code IR 05000402/20060251985-08-0202 August 1985 Insp Rept 50-424/85-28 on 850402-0625.Deficiency Noted: Purchase of Superplasticizer as non-Q Matl,Problems Re Filing & Retrievability of Records & Lack of Timeliness in Issuing Deficiency Rept for Tensile Failures IR 05000400/19850231985-06-12012 June 1985 Insp Rept 50-400/85-23 on 850528-30.No Noncompliance Noted. Major Areas Inspected:Physical Security Plan Implementing Procedures,Security Organization & Physical Barriers.Details Withheld (Ref 10CFR2.790 & 73.21) IR 05000261/19850161985-05-24024 May 1985 Insp Repts 50-261/85-16,50-324/85-13,50-325/85-13 & 50-400/85-17 on 850506-09.No Violations or Deviations Noted. Major Areas Inspected:Preoperational Radiological Environ Monitoring Program at Shearon Harris & QA at Harris Lab IR 05000401/20060211985-01-28028 January 1985 Insp Repts 50-445/85-07 & 50-446/85-05 on 850401-0621. Violation Noted:Failure to Promptly Correct Identified Problem w/RTE-delta Potential Transformer Tiltout Subassemblies IR 05000400/19820201982-07-13013 July 1982 IE Insp Repts 50-400/82-20 & 50-401/82-20 on 820622-25.No Noncompliance Noted.Major Areas Inspected:Licensee Identified Items,Ie Bulletins & Circulars,Electrical Components & Sys & Inspector Followup Items IR 05000400/19820191982-07-0808 July 1982 IE Insp Repts 50-400/82-19 & 50-401/82-19 on 820614-17.No Noncompliance Noted.Major Areas Inspected:Ie Bulletins,Qa Manual & Implementing Procedures for RCPB & safety-related Piping & Components & Licensee Action on Previous Findings IR 05000400/19820181982-06-14014 June 1982 IE Insp Repts 50-400/82-18,50-401/82-18,50-402/82-03 & 50-403/82-02 on 820525-28.No Noncompliance Noted.Major Areas Inspected:Const Progress,Inspector Followup & Licensee Identified Items & Reactor Vessel Installation IR 05000400/19820151982-06-0303 June 1982 IE Insp Repts 50-400/82-15 & 50-401/82-15 on 820510-13.No Noncompliance Noted.Major Areas Inspected:Work & Insp Procedures,Qa/Qc Organization,Cable Tray Installation, Conduit Installation & Storage of Electrical Equipment IR 05000400/19820161982-05-28028 May 1982 IE Insp Repts 50-400/82-16 & 50-401/82-16 on 820510-13. Noncompliance Noted:Improper Field Curing of Concrete Test Cylinders IR 05000400/19820101982-05-0505 May 1982 IE Insp Repts 50-400/82-10 & 50-401/82-10 on 820413-16. Noncompliance Noted:Improper Storage & Inadequate Maint on Fire Protection Sys Components 1989-09-28
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000400/19990091999-04-0909 April 1999 Partially Withheld Insp Rept 50-400/99-09 on 990308-12 (Ref 10CFR73.21).No Violations Identified.Major Areas Inspected: Aspects of Licensee Plant Support Re Physical Security Program for Power Reactors ML20155G9991998-10-23023 October 1998 Notice of Violation from Insp on 980816-0926.Violation Noted:License Failed to Promptly Identify Condition Adverse to Quality IAW Procedures ML20216H5161998-03-26026 March 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $55,000.Violation Noted:Licensee Did Not Follow Procedure SEC-NGGC-2101 ML20134J8551996-11-0707 November 1996 Notice of Violation from Insp on 960901-1012.Violations Noted:Operators & Shift Mgt Failed to Comply W/Direction in OMM-001 by Relying on Unreviewed & Unapproved List of Spare Breakers to Be Turned Off IR 05000400/19960991996-04-0303 April 1996 SALP Rept 50-400/96-99 for Harris Facility for Period of 940403-960316 ML20058P5341993-10-15015 October 1993 Partially Withheld Insp Rept 50-440/93-20 on 930913-17 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans,Protected & Vital Area Barriers,Detection Aids & Assessment Aids & Power Supply IR 05000400/19900251991-01-16016 January 1991 Insp Rept 50-400/90-25 on 901217-19.No Violations Noted. Major Areas Inspected:Simulator Exam Techniques,As Used in Licensed Operator Training Program IR 05000400/19890201989-09-28028 September 1989 Partially Withheld Insp Rept 50-400/89-20 on 890905-06 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Matl Control & Accountability of SNM Possessed & in Operation Under NRC License PNO-II-89-066A, updates Status of Hurricane Hugo for Nuclear Facilities in Southeast.Manning of Incident Response Ctr by Region II Continuing1989-09-21021 September 1989 PNO-II-89-066A:updates Status of Hurricane Hugo for Nuclear Facilities in Southeast.Manning of Incident Response Ctr by Region II Continuing IR 05000400/19890111989-06-28028 June 1989 Partially Withheld Insp Rept 50-400/89-11 on 890515-19 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program & Vital Area Barriers.Noncited Violation Confirmed IR 05000400/19890011989-05-30030 May 1989 Errata to Insp Rept 50-400/89-01,consisting of Confirmatory Measurements Comparison & Criteria for Comparisons of Analytical Measurements IR 05000400/19890021989-03-16016 March 1989 Partially Withheld Insp Rept 50-400/89-02 on 890130-0203 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Inadequate Package Search at Protected Area Barrier.Major Areas Inspected:Core Insp Program & Followup Items IR 05000400/19880371988-10-0707 October 1988 Partially Withheld Insp Rept 50-400/88-37 on 880926-30 (Ref 10CFR2.790(d) & 73.21).Violations Noted.Major Areas Inspected:Physical Barriers - Vital Areas,Access Control Packages & Vehicles & Safeguards Contingency Plan ML20151M4751988-03-21021 March 1988 Partially Withheld Physical Security Insp Rept 50-400/88-05 on 880229-0304.Violation Noted.Major Areas Inspected: Security Plan & Implementing Procedures & Mgt Effectiveness. Details Withheld (Ref 10CFR2.790 & 73.21) PNO-II-87-081, on 871221,evacuation Alarm Sirens Initiated Inadvertently.Caused by Wake County Personnel Error.Licensee Notified State & Local Officials & Responded to Media Interest1987-12-22022 December 1987 PNO-II-87-081:on 871221,evacuation Alarm Sirens Initiated Inadvertently.Caused by Wake County Personnel Error.Licensee Notified State & Local Officials & Responded to Media Interest ML20236B8851987-10-20020 October 1987 Performance Appraisal Nrc/State Contracts for Environ Monitoring on 871005-06.State Fulfilled All Requirements W/ Few Exceptions.Major Areas Inspected:Repts,Correspondence, day-to-day Contacts & Promptness in Resolution of Problems IR 05000401/20050301987-10-15015 October 1987 Notice of Violation from Insp on 870903.Violation Noted: Medical Isotopes Committee Did Not Meet Between 850401-0530, Failure to Maintain Written Records of Medical Isotopes Committee Meeting & Failure to Record Surveys IR 05000400/19870241987-09-23023 September 1987 SALP Rept 50-400/87-24 for Aug 1986 - June 1987 IR 05000400/19870331987-09-22022 September 1987 Partially Withheld Insp Rept 50-400/87-33 on 870831-0904 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Physical Security,Including Mgt Effectiveness Security Program,Records & Repts & Testing & Maint ML20237H3311987-08-27027 August 1987 Exam Rept 50-400/OL-87-02 on 870804-05.Exam Results:All Three Candidates Administered Operating Tests Passed & All Two Licensed Personnel Administered Integrated Plant Operation Exams Passed IR 05000400/19870171987-04-27027 April 1987 Partially Withheld Physical Security Insp Rept 50-400/87-17 on 870413-17 (Ref 10CFR2.790 & 73.21).No Violations Noted. Major Areas Inspected:Previous Enforcement Matters,Follow Up Items,Lers & Security Organization ML20209C7071987-03-30030 March 1987 Exam Rept 50-400/OL-87-01 on 870223-27.Exam results:9 of 12 Candidates Passed Simulator Exams & 1 of 2 Candidates Passed Group II Retakes IR 05000400/19860941987-03-24024 March 1987 Insp Rept 50-400/86-94 on 861220-870120.No Violations Noted. Major Areas Inspected:Status of TMI Action Items,Const Matl Testing,Precritical Testing,Initial Criticality & Low Power Testing IR 05000400/19870081987-03-23023 March 1987 Partially Withheld Physical Security Insp Rept 50-400/87-08 on 870209-13 (Ref 10CFR2.790 & 73.21).Violation Noted: Failure to Implement Compensatory Measures ML20207T5091987-03-12012 March 1987 Notice of Violation from Insp on 861215-17 ML20207T5481987-03-12012 March 1987 Notice of Violation from Insp on 870120-0220 IR 05000400/19870111987-03-11011 March 1987 Insp Rept 50-400/87-11 on 870226-0301.No Violations or Deviations Noted.Major Areas Inspected:Key Emergency Organizational Functions & Locations During Full Participation Emergency Preparedness Exercise IR 05000400/19870061987-03-10010 March 1987 Insp Rept 50-400/87-06 on 870120-0220.Violation Noted: Failure to Analyze Pump Test Data within Required Time Period IR 05000400/19870021987-02-19019 February 1987 Insp Rept 50-400/87-02 on 870107-29.No Violations or Deviations Noted.Major Areas Inspected:Startup Test Evaluation & Review,Witnessing of Loss of Offsite Power & Shutdown from Outside Control Room Tests IR 05000400/19860931987-02-18018 February 1987 Insp Rept 50-400/86-93 on 861215-17.Violation Noted:Failure to Adequately Review Procedure MST-I0322 Which Caused Improper Implementation of Procedure AP-20,in Violation of Tech Spec 6.8.1 IR 05000400/19870011987-02-12012 February 1987 Insp Rept 50-400/87-01 on 861203-870123.No Violations or Deviations Noted.Major Areas Inspected:Concerns Identified by Former Employee in Intervenor 861017 2.206 Petition IR 05000400/19870071987-02-11011 February 1987 Partially Withheld Insp Rept 50-400/87-07 on 870127-28 (Ref 10CFR2.790 & 73.21).Violation Noted:Failure to Provide Adequate Vital Area Barrier IR 05000400/19870031987-02-0505 February 1987 Insp Rept 50-400/87-03 on 870113-14.No Violation or Deviation Noted.Major Areas Inspected:Preoperational Insp of Radioactive Liquid & Gaseous Effluent Treatment Sys & Radiological Effluent Monitoring Sys ML20210T9331987-02-0303 February 1987 Notice of Violation from Insp on 861230-870106 IR 05000400/19860961987-01-29029 January 1987 Insp Rept 50-400/86-96 on 861230-870106.Violation Noted: Inadequate Test & Surveillance Procedures for Determination of RCS Leakage ML20210U8911987-01-15015 January 1987 Exam Rept 50-400/OL-86-04 on 871104-06.Exam Results:Seven Simulator Exam Candidates Passed & Four of Seven Candidates Passed Simulator Reexam IR 05000400/19860951987-01-15015 January 1987 Partially Withheld Insp Rept 50-400/86-95 on 861230-31 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Uncompensated Vital Area Breach IR 05000400/19860911987-01-13013 January 1987 Insp Rept 50-400/86-91 on 861120-1220.No Violation or Deviation Noted.Major Areas Inspected:Status of TMI Action Items,Licensee Action on Previous Enforcement Matters, Unresolved Items & Tech Specs Verification ML20207J2531986-12-29029 December 1986 Notice of Violation from Insp on 861103-07 ML20207K9051986-12-24024 December 1986 Notice of Violation from Insp on 861117-21 ML20207J2671986-12-24024 December 1986 Insp Rept 50-400/86-76 on 860922-26,1006-10 & 1103-07. Violation Noted:Failure to Check Required Operating Parameters Prior to Securing Emergency Diesel Generator ML20207J4331986-12-23023 December 1986 Notice of Violation from Insp on 861020-1120 ML20207J4711986-12-22022 December 1986 Insp Rept 50-400/86-87 on 861020-1120.Violation Noted: Failure to Follow Procedure While Performing Tech Spec Verification.Unresolved Item Re Clearance Tagging of Safety Injection Sys Identified IR 05000400/19860921986-12-22022 December 1986 Partially Withheld Security Insp Rept 50-400/86-92 on 861201-05 (Ref 10CFR2.790 & 73.21).Two Violations Noted. Major Areas Inspected:Plan/Procedures,Records/Repts, Barriers,Illumination,Access Controls & Detection Aids ML20207P9851986-12-22022 December 1986 Partially Withheld Security Insp Rept 50-400/86-92 on 861201-05 (Ref 10CFR2.790 & 73.21).Two Violations Noted. Major Areas Inspected:Plan/Procedures,Records/Repts, Barriers,Illumination,Access Controls & Detection Aids ML20207K9281986-12-12012 December 1986 Insp Rept 50-400/86-89 on 861117-21.Violation Noted: Inadequate Housekeeping Controls Around Reactor Vessel During Initial Fuel Loading IR 05000400/19860891986-12-12012 December 1986 Insp Rept 50-400/86-89 on 861117-21.Violation Noted: Inadequate Housekeeping Controls Around Reactor Vessel During Initial Fuel Loading IR 05000400/19860901986-12-11011 December 1986 Partially Withheld Insp Rept 50-400/86-90 on 861112-13 (Ref 10CFR2.790 & 73.21).Violations Noted:Inadequate Compensatory Measures & Inadequate Documentation ML20214K7061986-11-0707 November 1986 Exam Rept 50-400/OL-86-02 on 860224 & 0519-28.Exam Results: 9 of 11 Reactor Operators (Ros) Passed Written Exams & 14 of 24 Senior ROs Passed Oral Exams.Util Requested Mods to 43 Questions,Resulting in 13 Changes Due to Inaccurate Matls IR 05000400/19860231986-10-28028 October 1986 Partially Withheld Insp Rept 50-400/86-23 on 861007-09,16-17 & 19-21 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Locks & Keys,Detection Aids & Alarm Stations 1999-04-09
[Table view] |
Inspection Report - Harris - 1982019 |
---|
|
|
Text
- UNITED STATES 8 4*f, NUCLEAR REGULATORY COMMISSION t a REGION il 101 MARIETT A ST., N.W., SUITE 3100 s ATLANTA, GEORGIA 3o303
/
s Report Nos. 50-400/82-19 and 50-401/82-19 Licensee: Carolina Power and Light Company 411 Fayetteville Street Raleigh, NC 27602 Facility Name: Harri s Docket Nos. 50-400 and 50-401, License Nos. CPPR-158 and CPPR-159 Inspection at Harris site near Raleigh, Inspector: A E. H. Girard 7 -
Date Signed Approved' by: Mhmzw N. Econ'omoh Abting Section Chief
'7////V
,0ats Signed Engineering Inspection Branch Division of Engineering and Technical Programs SUMMARY Inspection on June 14-17, 1982 Areas Inspected This routine, unannounced inspection involved 30 inspector-hours on site in the areas of licensee action on previous inspection findings (Unit 1), status of IE Bulletins (Units 1 and 2), quality assurance manual (Units 1 and 2), quality assurance implementing procedures for reactor coolant pressure boundary and other safety-related piping (Units I and 2), and quality assurance implementing procedures for safety-related components (Units 1 and 2).
Results No violations or deviations were identified.
8208160371 820719 PDR ADOCK 05000400 G PDR
- - - -
. s i
! REPORT DETAILS j
'
j Persons Contacted Licensee Employees
- R. M. Parsons , Site Manager
- G. L. Forehand, Director QA/QC l *A. M. Lucas, Senior Resident Engineer
.
<
- D. C. Whitehead, QA Supervisor A. H. Hall, Lead Auditor
'
K. Douglas, QA/QA Tech 1 J. Harold, QA Inpsector i E. Betz, Senior QA Specialist, NDE NRC Resident Inspector
- * Attended exit interview i
l Exit Interview i
. The inspection scope and findings were summarized on June 18, 1982, with t those persons indicated in paragraph I above. The inspector's findings were presented by the NRC resident inspector. The following item, identified as
) a result of this inspection, was described during the interview:
) (0 pen) Inspector Follow-up Item (400/82-19-01): Qualifications of Auditors,
'
paragraph 6.
f Licensee Action on Previous Inspection Findings
{ (Closed) Unresolved Item (400/81-07-01): Audit !
!' This item was previously opened to address the inspector's concern that the licensee's audits appeared to be directed entirely towards records
! rather than work and, therefore, they did not appear to adequately I address the proficiency of personnel in the peformance of special
'
processe In the current inspection the inspector reviewed the checklists used by the licensee for performance of audits QAA 81-16 (May 1981). QAA 170-7 (January 1982) and QAA 170-8 (February 1982). In reviewing these audits the inspector found that actual work and work performance had been examined, including that of personnel performing certain special processes. The inspector considers this item close .
.. . .. .. . - .
. ,
T
-
i i
4. Unresolved Items j Unresolved items were not identified during this inspection.
5. Status of IE Bulletins (IEB's).(Units 1 and 2)
(Closed) IEB 400, 401/80-80-21: Valve Yokes Supplied by Malcolm Foundry
,
Company, Inc.
I
!
'
! The licensee submitted the initial response to this bulletin in a letter dated January 5, 1981. The response indicated that they had in storage for-installation in Units 1 and 2, four active safety-related valves containing yokes manufactured by Malcolm Foundry. In addition, the letter stated that
'
they had 40 active safety-related valves with hand wheels manufactured by Malcolm Foundr j The inspector discussed this item with the QA Supervisor and reviewed the i licensee's actions relative to the item as documented in their Deficiency (
,
and Disposition Report (DDR) 516 and their Corrective Action Report (CAR)
12-1-81. The disposition reported and verified in the documentation was to
- replace the yokes manufactured by Malcolm Foundry with acceptable yoke *
The CAR documented verification of yoke replacement on 11/23/81. Replace-j ment of hand wheels manufactured by Malcolm Foundry was deamed unnecessary i
'
- by the license Based on his review, the inspector considers this item closed.
,
6. Review of QA Manual (Units 1 and 2)
.
- As referred to in the title above, the licensee's "QA Manual" is considered
! to be the aggregate collection of QA and QC related instructions, proce-
- dures, plans and schedules which are used to implement the QA program described in the facility SA The inspector reviewed the licensee's "QA
] Manual" to verify that instructions, procedures, plans and schedules, had ,
j been established to control and accomplish selected safety-related activi- ,
- ties in accordance with the approved QA program. The inspector's review was .
- limited to activities for reactor coolant pressure boundary and other l
! safety-related components and pipina being installed at the Harris facility '
! by contractor Daniel Construction Compan The specific activities addressed by the inspector in his review and the related QA program imple-menting documents established by the licensee to accomplish and control i
, these activities are as follows: :
I Activities
- (1) Organizational structure and QA personnel i (2) Audits
'
,
'
(3) Quality requirements (specified, reviewed, controlled documented, i records maintained, identification, and control of items included) .
(4) Work and quality inspection procedures '
,
(5) Control of material i
! I
j h
,
. . . , _ . . _ _ _ .
____.______m... _ _ _ _ _ _ . _ . _ _ _ _ _ , _ . _ , _ _ . _ _ . _ _ . _ _
. .
(6) Control of processes (7) Corrective action (8) Document review (9) Test control and control of test equipment (10) Quality records Implementing Documents for Above Activities (1) Corporate Quality Assurance Program, Revision 3 (2) Corporate Quality Assurance Department, Engineering and Con-struction Quality Assurance / Quality Control Section (a) QA Instructions Number Title Revision QAI- QA/QC Personnal Qualification Requirements 8 QAI-12.1 Mechanical Installation Monitoring Guide for Safety-Related Piping, Valves & Components 0 QAI-12.2 Mechanical Installation Monitoring Guide for Safety-Related (Seismic Class I) Pipe Hangers 0 QAI-12.3 Mechanical Installation Monitoring Guide for Installation Mechanical Equipment & Components 1 (b) QA Procedures Number Title Revision COA-1 Personnel Training and Qualification 9 CQA-2 QA Document Control 2 CQA-4 QA Records O CQA-5 Document Reviews 0 CQA-8 Material Issue Surveillance O CQA-12 Mechanical Equipment Installation Monitoring 0 COA-21 Storage Control Surveillance O COA-24 Procurement Control 1
. .
CQA-26 Hoisting and Lifting Equipment Surveillance 0 (c) QC Procedures Number Title Revision CQC-1 Tool and Measuring Device Control 1 CQC-2 Nonconformance Control 4 CQC-6 Receiving Inspection 0 CQC-7 Marking and Tagging 0 CQC-12 Inspection of Code Valve Installation, Disassembly and Assembly 2 CQC-22 Hydrostatic Test Inspections 2-(3) EBASCO Specification - General Power Piping, CAR-SH-M-30 R14 (4) Site Specification 30 R6, Field Fabrication and Erection of Power Piping (5) Site Specification 34 R8, Nondestructive Examination, Visual Inspection and Testing Requirements for Code Class 1, 2, 3, MC, Seismic and Non Seismic Structure (6) Construction Procedures Manual Administrative Procedures Number Title Revision AP-IV-03 Preparation Approval Control of Procedures 28 AP-IX-02 Document Distribution and Control 15 AP-IX-05 Field Change Request (FCR) 25 AP-IX-06 Handling of Nonconformances 12 AP-IX-10 Specification for Site Procurement Use 17 AP-IX-16 SHNPP Site Processing of Deficiencies in Accordance with 10CFR50.55(e) and 10CFR21 3 AP-XIII-02 Material and Equipment Receiving 3
. .
-AP-XIII-03 Receiving Identification and Inspection 11 AP-XIII-04 Receiving Discrepancy 4 AP-XIII-05 Material Storage 11 AP-XIII-06 Receiving Reports and Documentation 2 AP-XIII-07 In-Storage Inspections and Maintenance 14 AP-XIII-08 Material Issue 10 (7) Construction Procedures Manual (a) Technical Procedures Number Title Revision TP-04 Calibration of Controlled Tools 18 TP-17 Construction Inspection Non Conformance Control 7 TP-24 Mechanical Pipe Installation Inspection 6 TP-28 Inspection of Equipment Installation 5 TP-45 Inspection of the Installation and Repair of Valves and Speciality Items' 0 TP-53 Inspection of Piping Flanged Connections 0 (b) Work Procedures Number Title Revision WP-102 Installation of Piping 8
'
WP-106 Maintenance / Protection of Permanent Plant Equipment 8 i
'
WP-115 Hydrostatic Testing of Buried or Embedded Pressure Piping (Nuclear Safety Related) 3
.
l
,
WP-116 Piping Spool Fabrication and Modification 3
[~
WP-128 Installation and Repair of Valves and Speciality Items 0
'
WP-6 Inspection and Testing of Hoisting Equipment Rigging Used in WP-7 4
'
.
I
. .
-
WP-21 Inspection of Equipment and Rigging for General Lifting 4 (8) Corporate QA Department Nondestructive Examination Manual (9) Corporate Quality Assurance Department Quality Assurance Procedure Manual In examining the licensee's qualification requirements for auditors, as described in the Corporate Quality Assurance Department Quality Assurance Procedure Manual (procedure CQAS 80-2 RO), the inspector found that the requirements were general in nature. The inspector was concerned that the lack of detail might lead to the use of auditors without adequate knowledge of areas being audited, particularly in the area of special processes. The inspector informed the licensee that the qualifications of auditors would be examined further in a subsequent inspection. This concern was identified as inspector follow-up item 400/82-19-01, " Qualifications of Auditors".
Within the areas inspected no violations or deviations were identifie . Reactor Coolant Pressure Boundary (RCPB) and Other Safety-Related (SR)
Piping - Review of Quality Assurance Implementing Procedures (Units 1 and 2).
The inspector reviewed the licensee's QA related procedures and instructions applicable to RCPB and other SR piping activities (except welding) to determine whether they adequately established and implemented requirements and controls in comformance with the QA program described in the SAR. The code applicable to on site fabrication of this piping is ASME Section III (74W76). Earlier revisions of ASME Section III apply to procured piping material and fabrication, as stated in the SA The control and requirement areas that were addressed by the NRC inspector,.
and the procedures and instructions identified and reviewed relative to these areas are as follows: Control and Requirement Areas (1) Procurement (2) Receiving inspection (3) Storage and issue (4) Handling - including protection from damage and contamination (5) Inspection and work in installation of piping and appurtenances (6) Cleaning Procedures and Instructions (1) Corporate Quality Assurance Program, Revision 3 (2) Admistrative procedures i
!
!
I
. - ..
- _._.-__- .- - - - . , - - - - - _ - . - _ - .
r
. . .
Number Title Revision
,
AP-XII-01 The Requisitioning of Materials I
& Equipment 20
'
AP-XII-03 Receiving Identification and j Inspection 11 i
l AP-XII-05 Material Storage 11 l (3) General Power Piping (4) Site Specification 30 R6, Field Fabrication and Erection of Power
'
Piping
! (5) Site Specification 34 R8, Nondestructive Requirements for Code Class 1, 2, 3. MC, Seismic and Non Seismic Structures I (6) Work procedures l Number Title Revision WP-102 Installation of Piping 8
'
WP-106 Maintenance / Protection of Permanent
! Plant Equipment 8
! WP-112 Control of Materials and Equipment That
{ May Be Harmful to Stainless Steel 2
!
j WP-113 Cleaning and Cleanliness Maintenance of
- ASME SECTION III and all other Piping I Systems 4
WP-115 Hydrostatic Testing of Buried or Embedded Pressure Piping 3 WP-116 Piping Spool Fabrication and Modification 3 WP-129 Bolt Torquing for In-Line Power Piping Flanged Connections 2 (7) Technical procedure TP-24 R6 Mechanical Pipe Installation In-spection (8) Quality control procedures Number Title Revision CQC-6 Receiving Inspection 0 CQC-10 Cleanliness Control of Fluid Systems and Components 2 CQC-22 Hydrostatic Test Inspections 2
.
. . .=-. . . ~ . .. _ _ . ~ . .. .
'
8 ,
I i
!
! (9) Quality assurance procedures !
'
!
- Number Title Revision
CQA-8 Material Issue Surveillance 0 ,
r i
! CQA-21 Storage Control Surveillance 0
'
i f 4 r
,
Within the areas inspected, no violations or deviations were identified.
- ;
! Safety-Related Components-Review of Quality Assurance Implementing Proce- !
dures (Units 1 and 2)
The inspector reviewed the licensee's QA related procedures and instructions i applicable to on-site activites for safety-related components to determine
whether they adequately established and implemented requirements and con- ;
trols in conformance with the QA program described in the SAR. The proce-dures and instructions reviewed were limited to those covering work per-formed - by contractor Daniel Construction Compan The code applicable to this work is ASME Section III (74W76). [
The requirement and control areas addressed by the NRC inspector and the ;
procedures and instructions identified and reviewed relative to these areas-were as follows: ,
! Control and Requirement Areas i
(1) Receipt inspection
-
(2) Installation - including inspection and testing I (3) Lifting
- (4) Post installation cleaning, preservation and inspection Procedures and Instructions (1) Quality control procedure CQC-6 RO, Receiving Inspection i
(2) Quality Assurance procedure CQA-12 R0, Mechanical Equipment .
Installation Monitoring !
(3) Technical procedures l Number Title Revision ,
j TP-28 Inspection of Equipment Installation 5 i ?
- TP-45 Inspection of the Installation and Repair !
- of Valves and Specialty Items 0 ( i l (4) Work procedures l
!
!
!
I i l
.
.
- e--., , ,,--..--,..,,.,--..m-% ..v,.,--- -
-w --+ . - - . - --v, , - - , - - - - . - - , - - , - . - . . ~ - . . - . - . ,c,, --- --
.. .
Number Title Revision WP-6 Inspection and Testing of Hoisting and Rigging Equipment Used in WP-7 4 WP-105 Installation of Equipment 6 WP-113 Cleaning and Cleanliness Maintenance of ASME Section III and all other Piping Systems 4 WP-125 Polar Crane Settings 1 WP-128 Installation and Repair of Valves and
,
Specialty Items 0 WP-131 Setting Reactor Coolant Pumps 1 Within the areas inspected, no violations or deviations were identified.