ENCLOSURE 1 EXAMINATION REPORT 400/0L-86-04 Facility Licensee:
Carolins Power and Light Company P. O. Box 1551 Raleigh, North Carolina 27602 Facility Name:
Shearon Harris Facility Docket No.:
50-400 Simulator examinations were administered at Shearon Harris near New Hill, North Carolina.
Chief Examiner:
h.-
m(
/ - / 2
,P ')
C. Gast F '
Date Signed Approvedby:hg 2[
4/v'/
(dbX
/
T Y d6hn F. Munro, Section Chief Date Signed Sumary:
Examinations on November 4-6, 1986.
Simulator examinations were administered to seven candidates; seven of whom passed.
Simulator re-examinations were administered to seven candidates; four of whom passed. One candidate has subsequently terminated employment with the facility and no longer requires a license.
a
&2.m REPORT DETAILS 1.
Facility Employees Contacted:
- W. Giese, Project Specialist i
- A.';Tollison, Manager, Nuclear Training Section:
t
- W. Powell, Director. Training HTU -
- J. Hudson, Senior Training Specialist
- C. Bethea, Director, Training, Robinson
- Attended Exit Meeting 2.
Examiners:
]
- C. Casto, W. Dean, L. Lawyer, J. I!unro, G. Maxwell (SRI) 4
- Chief Examiner 3.
Exit Meeting
)
At the conclusion of the site visit the examiners met with representatives l
of the plant staff to discuss the results of the examination.
There was one generic weakness noted during the simulator examination.
The area of below normal performance was in candidate understanding of system response. One simulator problem was noted in that there were no low power Initial Conditions (ICs) working properly.
The licensee did not identify as proprietary any of the material provided to or reviewed by the examiners.
i t
i 4
I
. - -