IR 05000400/1989002
| ML20246N241 | |
| Person / Time | |
|---|---|
| Site: | Harris |
| Issue date: | 03/16/1989 |
| From: | Masnyk O, Mcguire D NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | |
| Shared Package | |
| ML20246N223 | List: |
| References | |
| 50-400-89-02, 50-400-89-2, NUDOCS 8903270331 | |
| Download: ML20246N241 (1) | |
Text
--
,m
.
~ SAFEGUARQSMQFMATKi
. c.
/.
o, NUCLEAR REGULATORY COMMISSION -
L ~ ~.[
'
T.,
REGION il
.
.
g--
j 101 MARIETTA STREET, N.W.
q
ATLANTA, GEORot A 30323
'
>
'+9.:....
l
!
Report No.:
50-400/89-02 Licensee:
Carolina Power and Light Company P. O. Box 1551 Raleigi., NC 27602 Docket No.:
50-400 License No.:
NPF-63 Facility Name:
Shearon Harris Nuclear Plant Inspection Conducted: January 30 - February 3, 1989 Inspector:
/A/2.A M N
3-IT-87 0. M. Masnyk/ Ph sical Security &Sp cialist Date Signed
. Approved by:
L>
J-/fd7
..
r David R. McGui r Chief'
Date Signe'd
'
Physical Secur Section
. '
Nuclear Material Safety and Safeguards Branch Division of Radiation Safety and Safeguards SUMMARY Scope:
This routine unannounced inspection was conducted in the area of the Core I.ispection Program.
Additionally, the inspector reviewed the progress on Inspector Follow-up Items 88-21-01 and 88-21-02 and closed out Violation 88-21-03 and Information Notice 88-1N-91.
Results:
In the areas inspected, one violation was identified.
Inadequate package search at the protected area barrier.
The licent.ee took immediate compensatory measures and started a review to
,
determine the extent of vulnerability in this area and to identify l
"
corrective measures.
I
!
8903270331 890316 PDR ADOCK 05000400 Q
%,% pm.mtred terewith m. nastve unciamf.ed s % CRT!iOfl. When $Pparated f!0m SAFEGUARDS INFORhih
" ' * ' " " " " " " * " ' " " " " "