ML20040H111

From kanterella
Jump to navigation Jump to search
Forwards Allis Chalmers Engineering Rept ER-8102,Revision 1, Critical Crack Sizes of Comanche Peak Low Pressure Turbine Disks. Revision Replaces Rept Transmitted in Response to NRC Question 124.1
ML20040H111
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 02/10/1982
From: Schmidt H
TEXAS UTILITIES SERVICES, INC.
To: Burwell S
Office of Nuclear Reactor Regulation
Shared Package
ML20040H112 List:
References
TXX-3474, NUDOCS 8202170198
Download: ML20040H111 (1)


Text

- .. -- --------- - - - - - - - - - - - - - -

I l 4 TEXAS UTILITIES SERVICES INC. Log #T$-3474 un nny.w rowen. o4uu.rsx.w mm File # 910.2 February 10, 1982 g g o A 3 _ C M W SF BM Burwells. C g' g:f"3 g

" ~ Licirisin~ " Project" g Manager Z} FEB1g ggggt, ,

U. S. Nuclear Regulatory Comission - -

Office of Nuclear Reactor Regulation i u g % T M ,an .)

Washington, D.C. 20555 ,

mc s t-in s'

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION ALLIS-CHALMERS POWER SYSTEM INC. ENGINEERING REPORT ER-8102 REVISION 1

Dear Mr. Burwell:

Enclosed is one copy of Allis-Chalmers Power System Inc. Engineering Report, ER-8102 Revision 1 titled, " Critical Crack Sizes of '

Comanche Peak LP Turbine Disks". This revision replaces the original report previously transmitted by our letter TXX-3404 in response to NRC Question 124.1.

As with the original transmittal, the contents of Revision 1 may be handled as non-proprietary information.

Should you have questions concerning this report, please do not hesitate to contact me directly.

Sincerely, H. C. Schmidt BSD:tls cc: B. R. Clements - 1L R. A. Jones - 1L R. D. Calder - 1L John Enders - ACPSI - IL

$OO'i s,

///

8202170198 820210 PDR ADOCK 05000445 A PDR J