Jump to navigation Jump to search
Ro:On 810814,tritium Concentrations in Downstream Water Samples Exceeded Tech Spec Control Level for Second Quarter of 1981.Analysis of Max Dose Estimates Concluded That Concentrations Will Not Adversely Affect Public Health
ML20038C817
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 08/25/1981
From: Parker W
DUKE POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 8112140164
Download: ML20038C817 (2)


Text

_ _ _ _ _ _ _ . . . _ _ _ _ _ _ . _ _ _ _ _ _ . _ - - - . . - - _ - . - . . . _ _ . . ,_. . . . _-- .-

't DUKE POWER COMPANY ,

PowsH 13citurso 420 SOUTIl CHURCH STREET, CILAHt.OTTE. N. C. 08242

'c r h- 1 WI L LI AM O. PA R M E R. J R.

I (CF PEES.DrNT TEL EPwCN C' ARC A 704

) sm a mc m August 25, 1981

~' "'

1

! Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Commission ,' i i Region II ]~f ' '

f l

i 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 t[' _

l

!Y {l[.b" < '

l i Re: Oconee Nuclear Station 'c' Docket Nos. 50-269 -270, -287 DEC10 % , - !

7 o> ,

1 j

Dear Mr. O'Reilly:

[.

! .e> s j In accordance with the requirements of Oconee Nuclear Station, Technical ,

Specificatien 6.6.2.2.d, this report is submitted describing-ajcondition in which measured levels of radioactivity exceeded the control level by greater than 50 times (Location 000.7) and 10 times (Locatien 005.2).

On August 14, 1981, analytical results of surface water samples collected l

during the second quarter of 1981 were reviewed. A summary of pertinent l analytical results is given below:  !

l i

! Sample Locatio_n_ Date Collected Tritium Concentration 000.3 Hwy. 183 Bridge N. of 04/07-06/02/81 1.40 E2  ;

site. Lake Keowee (Control) 000.7 Hwy. 183 Bridge S. of 04/07-06/02/81 9.13 E3 site. Lake Hartwell  !

005.2 Hwy. 27 Bridge - Lake 04/07-06/02/81 1.98 E3 Hartwell Tritium concentrations in downstream water samples are dependent upon the ,

tritium concentrations of liquid effluent released from the station. For the period of April 1 to June 30, 1981, a total of 170.1 curies of tritium were released from the station in liquid effluents in accordance with Tech-nical Specification release requirements. Based on this release information, it is calculated that the activity released in the Keowee Hydro Station Tailrace was 1.16 E3 pCi/l during the second quarter of 1981.

l If an individual was to drink 730 1/yr of water at Location 000.7 (the closest i drinking water intake is more than 10 Km downstream), containing 9.13 E3 pCi/l of tritium, the maximum dose estimate would be 0.7 mR/yr. The maximum dose .

i MFFICIALCOJ?Y "'~ ~ ' '

I 8112140164 810825 hcTv PDR ADOCK 05000269 p a, c S PDR 3 g- 33_0 fA -

7_ .

I i -

Mr. James P. O'Reilly, Director August 25, 1981 Page 2 l

i

estimate of an individual drinking water from Location 005.2 (1.98 E3 pCi/1 of tritium) would be 0.15 mR/yr. Therefore, it is concluded that the observed anomalous tritium concentrations do not adversely affect public health and safety.

i Ver truly yours, ,

i s. ,

! /

, N M- $$- M G , .,

i William O. Parker, Jr.

l t

! JLJ/php  ;

i ie I

i I

h I l

. E I

i -

i l i

1

)

Je

._