4 DUKE POWER COMPd Powen Dt;iw!NO 422 Sourn Gnuncu STHEET, CuAH OTTe, N. C. 202 52

D j ',

...'O.gu W I L LI AM O. PA R K E R,,J R.

vie r P cs' '"'

      • "'^""7 March 12, 1982 LT rane PaocuCYioM g,

373-4083 C

Mr. James P. O'Reilly, Regional Adn.inistrator b

E{c

\\-

c_

N-K U. S. Nuclear Regulatory Commission jj Region II C g.

/

' 9 5

dI%,,,,IOg.8.

101 Marietta Street, Suite 3100 Atlanta, Georgia 30303

'fp g

7 N

Re: Oconee Nuclear Station j3 Docket No. 50-287

,g \\

Dear Mr. O'Reilly:

On February 26, 1982 your office was informed that the 3A2 HPI normal makeup nozzle was found to have the thermal sleeve tack welds broken, and subsequent investigation revealed cracks in the safe end and upstream piping. This constitutes performance of components that requires remedial action to pre-vent operation in a manner less conservative than assumed in the accident analyses in the safety analysis report. Reportable Occurrence Report R0-287/

82-04 providing details of this incident was to have been submitted to you by March 12, 1982, pursuant to Technical Specification 6.6.2.1.a(9). However, the investigation of this incident and the preparation of a report are incom-plete at this time.

It is expected that the investigation and report will be completed, reviewed, and submitted to you no later than April 9, 1982.

Very truly yours,

)]ff ',] l N)fl 0.

UlCYJ'//

William O. Parker, Jr.

JFK/php cc: Director Records Center Office of Management & Program Analysis Institute of Nuclear Power Operations U. S. Nuclear Regulatory Commission 1820 Water Place Washington, D. C. 20555 Atlanta, Georgia 30339 Mr. W. T. Orders Mr. Philip C. Wagner NRC Resident Inspector Office of Nuclear Reactor Regulation Oconee Nuclear Station U. S. Nuclear Regulatory Commission Washington, D. C. 20555

' n' t'ICl A L COQ 9204020464 820312 1L PDR ADOCK 05000287 y

S PDR D

'