_-..., - -

.y L

L v,W },

s k

%;. a r.1 OPERATINS DATA REPORT :

Mem -

g 4,

a(

' DOCKET 50-269' DATE W-14.

1:

0PERATil0 STATUS COMPLETED BY

- J.' A. Reavis -

V 2

it?UnitName:OCONEEl' TELEFHONE 704/373-7567 1

i U m 2.' Reporting Period: JULY 1,'1987-JULY 31,'1987 7 3l Licensed Thermal Peser-(MWtla

. 2568-

4.NaseplateRating(GrossMWel:.

934

l. Notes Year-to date and I;

15.DesignElectricalRatingjfHetMWel:

896-l cumulative Japacity factors i.

26; Maxinus Dependable Capacity (Gross-

'899' I are calculated using a weight-l

%7.LMaslausDependableCapacity(NetMWe):

. 860

1. ed average for maximus
l l - ( 8.'If Changes Occur in Capacity' Ratings'(Itess Nusber 3 Through 7) Since last i dependable capacity.

I

. Report Give Reasons:-

I l-

19. Power Level To Which Restricted, If Any (Net MWe): _,_,.._ _ _ __,,.. _ _.......__ ___.. _.,.. _.. _.._...
10. Reason for Restrictions,' If any..

t

.ThisMonth. Yr.-to-Date Cusulative a

A;

.11. Hsurs In' Reporting Period-744,0 5,$87.0

'123,076.0

?!2. Number Of' Hours Reactor Was Critical 744.0 4,761.7 91,156.6

13. Reactor Reserve Shutdown Hours' -

--0--

--0--

16 Hours Generator On-Onel 744.0 4,739.6

_87,741.7-S15.UnitReserveShutdownHours

--0--'

--0--

~--0--

~

~

310. 6 toss Thermal Energy Generated (MWHL.

1,663,4402 10,927,320

'211,653,425 17.' Gross Electrical Energy fenerated (MWH) 561,750 3,745,610 73,539,490

18. Het Electrical Energy Generated (MWH) 533,447 3,552,C86 69,735,630
19. Unit' Service' Factor.

100.0 93.2 71.3.

-20. Unit'AvallabilityFactor'.

100.0 93.2 71.3 E21. Unit Capacity Factor.(Using MDC Net) 83,4 21.2 65.7

22. Unit Capacity Factor (Using DER Net).

80,9 78.8 63.9 0.0 0.7 14.2

- 23. Unit Forced Outage Rate:

2N Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

..l...Rg f.g,e,U3lL,* Sp23,e.@,ey, 2 1987 - 9 weeks

23. If Shut Down At End Of Report Period. Estimatej Date of Startap;......,_. _ _.. _ _. ___ _._...... _

l26; Units'!n;TestStatus(PriortoCcesercialOperation):

Forecast Achieved i

INITIAL CRITICALITY i:

INITIAL ELECTRICITY K

COMMERCIALOPERATION p

L i

j a

4 3 '8708190274 870731' ('

[)

j-i.

PDR' -ADOCK 05000269_.

i k

R, PDR ?[

g].

l lG

V a

AVERAGE DAILY UNIT POWER LEVEL u

t DOCKET NO 50-269 UNIT Oconee 1

-_=...

DATE August 14,1987 COMPLETED J. A. Reavis TELEPHONE 704-373-7567 it0 NTH JULY,1987

-=

i DAY AVERA6E DAEY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWE-Net)

(MWE-Net) l 1

722 17 719

=....

2 722.

18 719 l

t I

i 3-722-19 719 i

l 4

721 20 719

...............=-

5 720 21 718 I

i 6

720 22 718 i.

............ =

=-.......

.7 719 23 718 8

719 24 718 1

9 718 25 717 10 719 26 717 j

I1 722 27 715 12 722 28 705 i

13 721 29 678 14 721 30 699 I

15 721 31 698

-=..........

I6 720

....=-

l l

1 h.-______._--..

O s o 6

_ ~ h2 I E AR noF(

l a

_ET h_3 E

NL R

P H

S R

I i O

S 9 E5 ~

V E

UO E

S G

S E

t st -

6 N7[)

I C

O T

TR I

O T

- at rG 2 O 3 [h 4 T

N GC A

I F H

L A

reoE

- C 0

C E

N W

NL W

GaepR I

7 0 O5[7 E

R I N UO T

O ph eU 0_

6h(

ROR LO G

O E

T G

t eSRN t

~ [ _

RTU OI NS GC S

NS i r

(

i M

N E

I O

C OT M

bPyt b

I EEVE CNE CC TE I N O

U TE rne i

i OMTDN OR E

AL LO T

D AL h rt el n

NAA O

DI GJ LB OI LB x onvi x

NDDH NTT NN UO OT N

N UO EfEEF E

)

)

T EP ACN I I CR CC O

O CR 4

5 ET T E AE D

RP E

I I

RP

(

(

KI E L E

V LE GJ T

T I

I CN L E S

E I R CE DN C

C CE OU P T U

R UU R

LI U

U R

D M

A P

BS RU B

D D

RU O

C S S ET E

E E

ET m)

C RE M

SA RR RR R

SA an OR E

NR OU E

M NR ri TP L

EE TS RT RU EJ mca C

B DP CS EI EU DP aSl AW O

NM AE WM WC NM r

p EO R

OE ER OI OA OE ccx RL P

CT RP PL PV CT SiE t

(

S l l a N

aamr O

T d uuoe I

N H

H H

X X

H onnt h T

E C

C C

X X

C h aaut

)

C 2

5 NE X

X X

X X

X t MMAO U

8 OD E

E E

X X

E e-(

D 9

P O T

T T

X X

T M1 234

)

E 1

MC H

H H

X X

H 3

R O

(

y C

R l

n E

u E

o W

J_

S MD B

F B

F H

F i

)

O 4

Y EO W

H W

H H

H t

P S TC a

(

n D

i N

m A

E a

S T

x S

NT R E

N EN O W

H CE PO e

)

O T

I V EN n

s D

N LE R i

n T

O a

e

?

U M

l c

n H

T N p

ni i

S T

TD U WX x

oL a

)

R 3EOFH O/

E i

l T

O MHOSDR

(

t t &

p

(

I P

s c

x N

E ee ig E

)

U R

2 A

D A

B A

D rt rn

(

REASON u

t i

)

(

l r snern io eivoi N

a R aira O

F e rt rl I S c

yT aE p TR t ngr r

x AU nanort rE RO enit cso(

UH mel at it D

pt el anar ninuurire ouif gemeh

)

sqaeepd pt TYPE F

F F

F F

F aEMRROAOO 1

e-(

RABCDEFGH

)

2 8

8 9

9 9

1

(

2 2

2 2

2 E

7 7

7 7

7 7

d T

e A

l D

7 7

7 7

7 7

d u 8

8 8

8 8

8 ed ce rh oc P

p p

p p

p FS NO 2

3 4

9 0

1 FS 1

1 1

)

1 1

1

(

l

DOCKET NO:

50-269 UNIT:

Oconee 1 DATE:

8/14/87 l

l NARRATIVE

SUMMARY

l f 'f 9 Month: July, 1987 l

Oconee Unit i began the month of July operating at 87%, limited by Reactor Building Cooling Units and Low Pressure Injection Cooler problems. The unit was l

reduced to 85% power on July 28 due to High Condenser Circulating Water temper-ature. At 1915 on July 29, the unit was reduced to 82% power due to a loss of The unit returned to 85% power the same day, where it operated for the vacuum.

remainder of the month.

l

\\

l

J i

L I

1 MONTHLY REFUELING INFORMATION REQUEST 1.

Facility name: Oconee, Unit 1 2.

Scheduled next refueling shutdown:

September, 1987 Sc!cduled restart following refueling: November, 1987 3.

i 4.

Will refueling or resumption of operation thereafter require a technical specification change or other license amendment? Yes If yes, what will these be?

Technical Specification Revision If no, has reload design and core configuration been reviewed by Safety Reviev Committee regarding unreviewed safety questions? N/A 5.

Scheduled date(s) for submitting proposed licensing action and supporting info rmation: -N/A 6.

Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).

7.

Number of fuel assemblies (a) in the core:

177 I

(b) in the spent fuel pool:

883*

8.

Present licensed fuel pool capacity:

1312 1

Siza of requested or planned increase:

9.

Projected date of last refueling which can be accommodated by present licensed capacity: August, 1991 o

DUKE POWER COMPANY DATE: August 14, 1987 Name of

Contact:

J. A. Reavis Phone:

704-373-7567

  • Represents the combined total for Units 1 and 2.

OPERATINS DATA REFORT s

DOCKET 50-270 DATE 8 14-87 OPERATih6 STATUS COMPLETED BY s

TELEPHONE 704/373-7567

1. Unit Name: OCONEE 2
2. Reporting Period: JULY 1, 1987-JULY 31, 1987
3. Licensed Thersal Power (MWth 2569
4. Naseplate Rating (Gross MWeh 934 i Notes Year-to date and I
5. Design Electrical Patirg (Net MWe):

896 I cumulativecapacityfactpf I

6. Maxisue Dependable Capacity (Gross 899 I arecalculatedusingaweight-l
7. Maxisua Dependable Capacity (Net MWeb 860

! ed average for maxieue 1

8. If Changes Occur in Capacity Ratings (Iteas Nuiter 3 Throcgh 7) Since Last I dependable capacity, i

Report 6iye Reasons:

l _,_,,,_............... __l

9. Power Leve! To Which Pestricted, If Any (Net MWeh............. _...............,__............ _. _.. _.._.._ _
10. Feason For Restrictions, If any:

-..n..................................................

i This Month Yr.-to-Date Cusu17tive

11. Hours In Reporting Period 744,0 5,087.9 113,016.0
12. Number Of Hours Reactor Was Critical 744.0 4,947,9 85,039.1
13. Reactor Feserve Shutdown Hours

- - -0---

14. Hours Generator On-Line 744.0 4,916.6 E3,642.5
15. Unit Feserve Shutdown Hours

--0--

--0--

--0--

16. Grcss Thermal Energy Generated (MWH) 1,650,504

!!,448,144 199,736,422

17. Gross Electrical Energy Generated MWH) 556,350 3,923,550 69,057,071 I
18. Het Electrical Energy 6erereted (MWH) 526,774 3,741,766 64,710,392 l'
18. Unit Service Factor 100.0 96.7 74.0 LO. Unit Availability Factor 100.0 96.7 74.0
21. Unit Capacity Factor (Using MEC Net) 62.5 E5.5 66.4
22. Unit Capacity Factor (Using DER Net) 60.2 03.0 64.6
23. Unit Forced Outage Rate 0.0 3.4 12.3 24, ShWewns SMled Over hext b sonths liype, Date, and Duration of Eachh l

... 3 9nc..............................

~................................................. -.......--..-- --......-...-.

l

.........................~............... -............. ~. ~... ~......-...--. -....-.-. -......-....---.-...-...

25. If Shut Down At End Of Recert Period. Estiaated Date of Stattus:..._.... _........__....._.,......_............ _

f

26. Units in Test Status (Prior to Couercial Operationh forecast Achieved l

l l

INITIAL CRITICALITY l

IMTIAL ELECTRICITY l

COMERCIAL OPERATION l

t l

l l

l l

l'

I.

1 i

I i

AVERAGE DAILY UNIT PCWER LEVEL i

1 l

DOCKET NO 50-27)

Udli Oconee 2 DATE August 14,1987 q

l CCMPLETED

3. L. R m is TELEPHONE 704-373-7567 j

liONTH JULY, 1987 2

DAY AVERAGE DAILY PDWER LEVEL DAY AVERAGE DAILY POWER LEVEL W E-Net)

W E-Net) 1 718 17 713 2

717 18 711 3

716 19 712 4

716 20 711 5

708 21 711 6

715 22 710 23 711 7

712 8

712 24 710 9

711 25 708 i

i li 704 20 707 11

?l4 27 707 1E 713 22 705 13 713 20 704 14 713 30 703 15 714 31 701 16 713 j

)

[ _ _

\\

s e

Il.

ll I

nas e

~ [ _ _

ot n c

~ [ _ _

iae r

~ [

_7 tDc u

~ ~ _

_6 R

R R

c i

o

~ [S5 O

O O

u ' L

's S

~ ~

_I 7 T

T C

T ro R

~ [V -

A A

I A

t rE1 e

2[A3 R

R R

D R

snoL6 m

~ [E7 E

E E

O E

noF(

1 a

E[ R_3 E

N H

N N

I i 0

S I

0E5 V

E E

C E

R E

t st -

7

]

.)

I C

G T

G E

E m

- at rG 2U[4 A_0 4

T N

A P

reoE l

U[/

C E

M P

M M

G a e pR I

0U[

7 E

R A

S A

T A

ph eU 5~

d_ J_ (

ROR E

I E

N E

t eSRN t

~

RTU T

D T

E T

ir

~

(

i O

C S

S M

S bPyt b

EEYE CNE R

E i

rne i

OMTBN OR E

V hrt el h

NAA O

DI B

P B

O B

xonvi x

NDDH NTT M

)

EfEEF E

)

T EP ACN N

4 5

ET TE AE N

O N

E N

(

(

KI EL E

V I

I I

V I

CN LE S

E T

L OU PT U

R L

C L

A L

D M

A P

E U

E V

E C

C V

D V

V m)

C E

E7 E

EG E

an.

L R3 L

NN L

ri I I mca H

DU H

BT H

aSl G

AQ G

RS C

r p

OE I

UE I

ccx I

H LR H

TT H

SiE t(

S l l a N

aamr O

T d uuoe I

N H

2 H

X H

onnt h T

E C

2 C

E C

,h aaut

)

C 7

5 NE X

2 X

V X

t MMAO U

8 OD C

2 E

L E

e-(

O 9

PO T

2 T

A T

M1 234

)

T 1

MC H

2 H

V H

3 R

O

(

y C

R l

n E

u E

o W

J_

SMD H

Z P

B H

i

)

O 4

YEO C

Z C

H C

t P

STC a

(

n D

i N

m A

E a

S T

x S

NTR E

N ENO W

H CEPO e

)

O T

I VEN n

s D

fj LER i

n T

O a

e

)

U M

l c

n P

TN p

ni i

TD UWX x

oL a

S T-

)

R 3EOFHO/

E i

l T

U MHOSDR

( t t&

p

(

P s

c x

I N

E ee ig E

)

U H

2 A

F A

B A

rt rn

(

REASON u

ti

)

(

l r snern i o eivoi N

a Raira O

Fe rt rl I S c

yT aEp TR t ngr r

x AU nanort rE RO enit oso(

UH mel ati t D

pt el anar ninuurire ouif gemeh sqaeepd pt

)

TYPE F

S F

5 F

aCMRROAOO 1

e-(

RABCDEFGH

)

2 5

5 0

0 1

(

1 1

E 7

7 7

7 7

d T

e A

l D

7 7

7 7

7 d e 8

8 8

8 8

ed ce rh

}

p p

p p

p oc FS NO 5

6 7

8 9

1 1

1 1

1

) FS 1

(

I!

il l

DOCKET NO:

50-270 UNII:

Oconee 2 DATE:

8/14/87 NARRATIVE SUle!ARY Month: July, 1987 Oconee Unit 2 began the month of July operating at 87%, limited by high levels

)

in the "B" Steam Generator. On July 5, at 0621, the unit reduced load to 80%

for approximately two hours, to assist the dispatcher in meeting minimum system load. On July 10, the unit reduced power to 79% to conduct a Control Valve Movement rest. The unit then returned to 87% power. The unit finished the month operating at 86%, increasingly limited by high levels in the "B" Steam i

Generator, f

)

e

MONTHLY REFUELING INFORMATION REQUEST i

1.

Facility name: Oconee, Unit 2 2..

Scheduled next refueling shutdown:

January, 1988 3.

Scheduled restart following refueling: April, 1988 4.

Will refueling or resumption of operation thereafter require a technical specification change or other license amendment? Yes If yes, what will these be?

Technical Specification Revision If no,'has ceload design and core configuration been reviewed by Safety Review t [A, Committee regarding unreviewed safety questions?

j 5.

Scheduleo date(s) for submitting proposed licensing action and supporting information: N/A 6.

Important licensing considerations (new or different design or supplier, i

unreviewed design or performance analysis methods, significant changes in I

design or new operating procedures).

i 7.

Number of fuel assemblies ta) in the core:

177 (b) in tho spent fuel pepl: 883*

8.

Present licensed fuel pool capacity:

1312

{

Size of requested or planned increase:

9.

Projected date of last refueling which can be accommodated by present licensed capacj.ty: August, 1991 l

{

~

DUKE POWER COMPANY DATE: August 14, 1987

)

Name of

Contact:

J. A. Reavis Phone:

704-373-7567 1 Represents the combined total for Units 1 and 2.

f

0PEFA11N3 DATA REPORT t

DOCKET 5F287 CATE 8-14-87 CFERATING STATUS CCF?LETED H J. A. Reavis TELEFHONE 70437c-l567

1. Unit Nau: OCONEE 3
2. Reporting Period: JULY 1, 1937-JULY 31, 1997
3. License 1 Theraal Power (MWt):

2566

4. Nasestate Rating (Gross MWe):

934

! Notes Year-to date and 1

5. Les)1n Electrical R;. ting (Net MWe):

896 I cuaulative capacity facters I

6. Maxieu Cependable C4pacity (Gross E99 I are calculated using a neight-1
7. Maximus Dependable C oacity (let MWe)!

860 i ed average for savieue l

B. If Changes Occur in Capacity Ratings (Itess Nuster 3 Through 7) Since Last i dependable capacity.

I Report. Give Reasons:

I I

9. Power level To Which Festricted, If Any (Net MWe):
10. Reason for Restrictions, If any:

e This Month Yr.-to-Cate Cueulative

11. Hours In Reporting Feried 744.0 5,097.0 110,663.0
12. N'taber Of Hours Reac*or Was Crit: cal 744.0 2,469.2 79,675.9
13. Reactor Reserve Shutdown Heurs

--0--

--0--

--0--

14. Hcurs Generator On-Line 7H.0 2,396.9 79,312.2
15. Unit f<eserve Shutdenn Hurs

~0-- - - 16. Scoss Thersal Energy SeaerateC (MWH) 1,911,816 6,020,808 191,467,918 17, Gross Electrical Ecergy Generated (MWH) 659,973 2,092,578 0973N2 l

18. Net Electrical Energy Generated (MWW 631,617 4,786,992 e2,330,645 l
19. Unit Service Factor 100.0 47.1 E8
20. Unit Availability Factor 104.0 67.1

'70.8

21. Unit Capacity Factor (Using MDC Net) 93.7 45.9 55.9
22. Unit Capacit/ Factor (Using CER Net) 95.?

44.1 64.1 23, Unit Forced Outage Fate 0.0 2.5 1?J l

24. Shut 4 ns Scheduled Over Next 6 Months (Type, Date, and hratict of Each):

l l

....Nona........-.............................................................................................

1

25. If Shut Down At End Of Report Feriod. Estimated Date of Startup:

I 36 taits In Test Status (Frior to Cosaercial Operation):

Ferecast Achie3ed INITIAL CRITICALITY IN!TIAL ELECTRICITY C0MERCIAL OFERATION l

t i.

(-

e i

s.

+

1 l

AVERASE DAILY UNIT P0iER LEVEL l

l..

DCCLET NO 50-287 UNIT Oconea 3 1

1) ATE - August 14, 1987 CONLETED J. i. Reavis T3EPHONE 704-373-7567 MONTH JULY,1987

......~.....................

f l

DAY AVERA62 DAILY POWEP LEVEL DAY AVERAGE DAILY POWER LEVEL (MWE-het)

-~

(MWE-Net) l 854 17 850 f

853 18 849

?

853 19 80 4

852 29 848 5

852 21 849 6

852 22 848

(

7 852 23 837 8

851 24 847 l

9

%51 25 847

...~...........................

10 650 26 846 11 651 27 846 12 851 28 846 13 850 29 845 14 649 30 845

.....,.............~.........

13 C50 31 845 16 849

7Ep R_3-V E

N t st -

8 N ]4 h_0

)

I C

O O

- at rG t

T N

VE reoE 2Q 1

C E

RV T

GaepR

- C /

0 Q8._ 7 E

R EL N

ph eU

_0 _ J_1_

ROR SA E

t eSRN 5

RTU V

M ir O

C O

E bPyt

.EEYE CNE TL C

i rn OMTBN OR O

A h rt el NAA O -

Dl ER L

xonvi EfEEF

.NDDH NTT UT P

)

T EP ACN DN)

E 4

ET TE AE OD R

(

KI EL E

V KCE CN LE S

E C

S E

OU PT U

R ANO V*

D M

A P

BOL L1 O

C N

C A'

m

!E t

V#

a C

RRE r

UV OE mc TLL VV aSl I I A RL r

NAV EA ccx UF(

SV SiE t

S l l a aamr N

O T

d uuoe I

N X

X onnt h E

E E

h aaut T

)

C 2

5 NE V

V tMMAO U

8 OD L

L e-(

M1 234 D

9 PO A

A

)

1 MC V

V 3

E O

(

y C

1 R

M E

E S MD B

B J_

W

)

4 Y EO H

H O

S TC P

(

D N

A E

S T

S NT R N

EN O W

H CE PO

)

O T

I V EN n

D N

LE R i

T O

a U

M l

H T N p

TD U WX x

S T

)

R 3EO FH O/

E

(

t T

O

(

MH CS DR I

P s

ee N

C l

U R

E A

B rt RE ASON u

(

l r io N

a O

Fe I S c

TR t ngr AU nanor RO enit UH mel at pt el D

ninuuri ouif geme sqaeepd p

)

1 TYPE F

F aCMRHO e-(

RABCDE

)

2 3

3 2

2 E

7 7

d T

e A

l D

7 7

d e 9

8 ed ce rh p

p oc FS 1

2 NO FS 1

1

)

1

(

1 DOCKET No:

50-287 UNIT:

Oconee 3 DATE:

8/14/87 1

NARRATIVE

SUMMARY

1 Month:

July, 1987 Oconee Unit 3 began the month at 100% power. At 0802 on July 23, the unit had a j

l runback to 95% power due to a Servo Valve failure on control Valve //1. The unit was subsequently reduced to 93% power to replace the failed Servo Valve. The unit returned to 100% at 1535 on July 23, where it operated for t.he remainder of the month.

\\

\\

HONTHLY REFUELING INFORMATION REQUEST

i. Facility name: Oconee, Unit 3 2.

Scheduled next refueling shutdown: August. 1988 3.

Scheduled restart following refueling:

October, 1988 4.

Will refueling or resumption of operation thereafter require a technical-specification change or other license zunendment? Yes If yes, what will these be?

Technical Specification Revision If no, has reload design and core configuration been reviewed by Safety Review l

Committee regarding unreviewed safety questions? N/A j

l 5.

Scheduled date(s) for submitting proposed licensing action and supporting information: N/A 6.

Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in-desi,7n or new operating procedures).

7.

Number of fuel assemblies (a) in the core:

177 (b) in the spent fuel pool:

528 8.

Present licensed fuel pool capacity:

875 Site of requested or planned increase:

9.

Projected date of last refueling which can be accouraodated by present licensed capac.t ty: hugust, 1991 1

J i

DUKE POWER COMPANY DATE: August 14, 1987 Name of

Contact:

J. A. Reavis Phone:

704-373-7567 1

1

)

J

'\\

OCONEE NUCLEAR STATION l

MONTHLY OPERATING STATUS REPORT 1.

personnel Exposure For the month of June, no individual (s) exceeded 10 percent of their allowable annual radiation dose limit.

2.

The total station liquid release for June has been compared with the I

Technical Specifications maximum annual dose commitment and was less than 10 percent of this limit.

The total station gaseous release for June has been compared with the Technical Specifications maximum annual dose commitment and was less than 10 percent of this limit.

l k

l l

l i

i i

i i

p l

1

?

3 3

ii i

I 3

l

l 1

)

I

]

Dtre Powen GOMRiNY I'f>. UUX CCtHD l

CILARLOTEF. N.C. 128242

)

IIAL 0 TilGiWR Tr t.ept. aNE va r rescuwwr (704} 373 450L nu LFU f*OUMMUFG

)

Angust 14,.1987 U. S. Nuclear Regulatory /; omission Attention:

Document Cort rol ' Desk Washington, L.

C.

20555 Re:

Oconee Nuclear Station Docket No. 50-169, - 17fi, -287

Dear Sir:

Please find atta aed informatim; concerning the performance and operating status of the Oconee Nuclear Scation for the nonta of July. 1987.

Very truly yours,

(

A

-c/

  • ,y Hal B. Tucker JAR /32/ son Attactunent xc:

Dr. J. Nelson Grace, Regional Administrator American Nuticar Insurers U. S. Nuclenr Regulatory Comission c/o Dott.in Sherman, ANI Library Region 11 The Exchange, Suite 245 101 Marietta Street, NW, Suite 2900 270 Farmington Avenue Atlanta, Georgia 3 G"$23 Farmington, CT 06032 Mr. Phil Ross INPO Records Center U. S. Naelear Regalatory Ccamission Suite 1500 MNBB-5715 1100 Circle 75 Parkway Washington, D. C.

20555 Atlanta. Georgia 30323 Ms. Helen Paatis, Project Manager Ma. Judy Dovers Office of Nuclear Reactor Regulation Nuclear Assurance Corporation U. S. Nuclear Regulatory Comission 5720 Peachtree Paikway Washington, D. C.

2055S Norcrosn 'leorgia 3n092 Mr. J. C. Eryant NRC Resident Inspector Oconee Nuclear Station I