Similar Documents at Cook |
---|
Category:MONTHLY OPERATING ANALYSIS REPORT
MONTHYEARML17335A5621999-09-30030 September 1999 Monthly Operating Rept for Sept 1999 for DC Cook Nuclear Plant,Unit 2.With 991012 Ltr ML17335A5631999-09-30030 September 1999 Monthly Operating Rept for Sept 1999 for DC Cook Nuclear Plant,Unit 1.With 991012 Ltr ML17326A1201999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Cook Nuclear Plant, Unit 1.With 990915 Ltr ML17326A1211999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Cook Nuclear Plant, Unit 2.With 990915 Ltr ML17326A0861999-07-31031 July 1999 Monthly Operating Rept for July 1999 for DC Cook Nuclear Plant,Units 2.With 990812 Ltr ML17326A0871999-07-31031 July 1999 Monthly Operating Rept for July 1999 for DC Cook Nuclear Plant,Unit 1.With 990812 Ltr ML17326A0511999-06-30030 June 1999 Monthly Operating Rept for June 1999 for DC Cook Nuclear Plant,Unit 2.With 990709 Ltr ML17326A0501999-06-30030 June 1999 Monthly Operating Rept for June 1999 for DC Cook Nuclear Plant,Unit 1.With 990709 Ltr ML17326A0071999-05-31031 May 1999 Monthly Operating Rept for May 1999 for DC Cook Nuclear Plant,Unit 2.With 990609 Ltr ML17326A0061999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Dcp.With 990609 Ltr ML17335A5301999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for DC Cook Nuclear Plant,Unit 1.With 990508 Ltr ML17335A5291999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for DC Cook Nuclear Plant,Unit 2.With 990508 Ltr ML17325B5441999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for DC Cook Nuclear Plant,Unit 1.With 990408 Ltr ML17325B5491999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for DC Cook Nuclear Plant Unit 2.With 990408 Ltr ML17325B4631999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for DC Cook Nuclear Power Station,Unit 2.With 990308 Ltr ML17325B4621999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for DC Cook Nuclear Plant,Unit 1.With 990308 Ltr ML17335A5201999-01-31031 January 1999 Monthly Operating Rept for Jan 1999 for Dccnp Unit 1.With 990208 Ltr ML17335A5191999-01-31031 January 1999 Monthly Operating Rept for Jan 1999 for Dccnp,Unit 2.With 990208 Ltr ML17335A4831998-12-31031 December 1998 Monthly Operating Rept for Dec 1998 for DC Cook Nuclear Plant,Unit 2.With 990108 Ltr ML17335A4841998-12-31031 December 1998 Monthly Operating Rept for Dec 1998 for DC Cook Nuclear Plant,Unit 1.With 990108 Ltr ML17335A3951998-11-30030 November 1998 Monthly Operating Rept for Nov 1998 for DC Cook Nuclear Plant,Unit 2.With 981207 Ltr ML17335A3941998-11-30030 November 1998 Monthly Operating Rept for Nov 1998 for DC Cook Nuclear Plant,Unit 1.With 981207 Ltr ML17335A3331998-10-31031 October 1998 Monthly Operating Rept for Oct 1998 for DC Cook Nuclear Plant,Unit 1.With 981105 Ltr ML17335A3381998-10-31031 October 1998 Monthly Operating Rept for Oct 1998 for DC Cook Nuclear Power,Unit 2.With 981105 Ltr ML17335A2931998-09-30030 September 1998 Monthly Operating Rept for Sept 1998 for DC Cook Nuclear Plant,Unit 2.With 981005 Ltr ML17335A2941998-09-30030 September 1998 Monthly Operating Rept for Sept 1998 for DC Cook Nuclear Plant,Unit 1.With 981005 Ltr ML17335A2131998-08-31031 August 1998 Monthly Operating Rept for Aug 1998 for DC Cook Nuclear Plant,Unit 2.W/980903 Ltr ML17335A2151998-08-31031 August 1998 Monthly Operating Rept for Aug 1998 for DC Cook Nuclear Plant,Unit 1.W/980903 Ltr ML17335A1741998-07-31031 July 1998 Monthly Operating Rept for July 1998 for DC Cook Nuclear Plant Unit 2.W/980806 Ltr ML17335A1731998-07-31031 July 1998 Monthly Operating Rept for July 1998 for DC Cook Nuclear Plant Unit 1.W/980806 Ltr ML17334B8171998-06-30030 June 1998 Monthly Operating Rept for June 1998 for DC Cook Nuclear Plant Unit 2.W/980706 Ltr ML17334B8131998-06-30030 June 1998 Monthly Operating Rept for June 1998 for DC Cook Nuclear Station,Unit 1.W/980706 Ltr ML17334A7511998-05-31031 May 1998 Monthly Operating Rept for May 1998 for DC Cook Nuclear Plant,Unit 2.W/980609 ML17334A7521998-05-31031 May 1998 Monthly Operating Rept for May 1998 for DC Cook Nuclear Plant,Unit 1.W/980609 Ltr ML17334B7921998-04-30030 April 1998 Addendum to Monthly Operating Rept for Apr 1998 for DC Cook Nuclear Station,Unit 2 ML17334B7721998-04-30030 April 1998 Monthly Operating Rept for Apr 1998 for DC Cook Nuclear Plant,Unit 1.W/980506 Ltr ML17334B7911998-03-31031 March 1998 Addendum to Monthly Operating Rept for Mar 1998 for DC Cook Nuclear Plant,Unit 2 ML17334B7171998-03-31031 March 1998 Monthly Operating Rept for Mar 1998 for Donald C Cook Nuclear Plant,Unit 1.W/980407 Ltr ML17334B7181998-03-31031 March 1998 Monthly Operating Rept for Mar 1998 for Donald C Cook Nuclear Plant,Unit 2.W/980407 Ltr ML17334A6831998-02-28028 February 1998 Monthly Operating Rept for Feb 1998 for Donald C Cook Nuclear Plant,Unit 2.W/980309 Ltr ML17334A6811998-02-28028 February 1998 Monthly Operating Rept for Feb 1998 for Donald C Cook Nuclear Plant,Unit 1.W/980309 Ltr ML17334B7901998-02-28028 February 1998 Addendum to Monthly Operating Rept for Feb 1998 for DC Cook Nuclear Plant,Unit 2 ML17334A6481998-01-31031 January 1998 Monthly Operating Rept for Jan 1998 for DC Cook Nuclear Plant,Unit 2.W/980209 Ltr ML17334B7891998-01-31031 January 1998 Addendum to Monthly Operating Rept for Jan 1998 for DC Cook Nuclear Plant,Unit 2 ML17334A6051997-12-31031 December 1997 Monthly Operating Rept for Dec 1997 for Donald C Cook Nuclear Plant,Unit 2 ML17334A6021997-12-31031 December 1997 Monthly Operating Rept for Dec 1997 for Donald C Cook Nuclear Plant,Unit 1.W/980108 Ltr ML17334B6711997-11-30030 November 1997 Monthly Operating Rept for Nov 1997 for DC Cook Nuclear Plant,Unit 2.W/971208 Ltr ML17334A6061997-11-30030 November 1997 Revised Monthly Operating Rept for Nov 1997 for DC Cook Nuclear Station,Unit 2 ML17334B6651997-11-30030 November 1997 Monthly Operating Rept for Nov 1997 for DC Cook Nuclear Plant,Unit 1.W/971208 Ltr ML17333B1421997-10-31031 October 1997 Monthly Operating Rept for Oct 1997 for Donald C Cook Nuclear Plant,Unit 1.W/971110 Ltr 1999-09-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML17335A5641999-10-18018 October 1999 LER 99-024-00:on 990708,literal TS Requirements Were Not Met by Accumlator Valve Surveillance.Caused by Misjudgement Made in Conversion from Initial DC Cook TS to W Std Ts.Submitted License Amend Request.With 991018 Ltr ML17335A5531999-10-0707 October 1999 LER 99-023-00:on 990907,inadequate TS Surveillance Testing of ESW Pump ESF Response Time Noted.Caused by Inadequate Understanding of Plant Design Basis.Surveillance Tests Will Be Revised & Implemented ML17335A5631999-09-30030 September 1999 Monthly Operating Rept for Sept 1999 for DC Cook Nuclear Plant,Unit 1.With 991012 Ltr ML17335A5621999-09-30030 September 1999 Monthly Operating Rept for Sept 1999 for DC Cook Nuclear Plant,Unit 2.With 991012 Ltr ML17335A5481999-09-30030 September 1999 Non-proprietary DC Cook Nuclear Plant Units 1 & 2 Mods to Containment Sys W SE (Secl 99-076,Rev 3). ML17335A5451999-09-28028 September 1999 Rev 1 to Containment Sump Level Design Condition & Failure Effects Analysis for Potential Draindown Scenarios. ML17326A1291999-09-17017 September 1999 LER 99-022-00:on 990609,electrical Bus Degraded Voltage Setpoints Too Low for Safety Related Loads,Was Discovered. Caused by Lack of Understanding of Design of Plant.No Immediate Corrective Actions Necessary ML17326A1481999-09-17017 September 1999 Independent Review of Control Rod Insertion Following Cold Leg Lbloca,Dc Cook,Units 1 & 2. ML17326A1211999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Cook Nuclear Plant, Unit 2.With 990915 Ltr ML17326A1201999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Cook Nuclear Plant, Unit 1.With 990915 Ltr ML17326A1121999-08-27027 August 1999 LER 99-021-00:on 990728,determined That GL 96-01 Test Requirements Were Not Met in Surveillance Tests.Caused by Failure to Understand Full Extent of GL Requirements. Surveillance Procedures Will Be Revised or Developed ML17326A1011999-08-26026 August 1999 LER 99-020-00:on 990727,EDGs Were Declared Inoperable.Caused by Inadequate Protection of Air Intake,Exhaust & Room Ventilation Structures from Tornado Missile Hazards. Implemented Compensatory Measures in Form of ACs ML17326A0911999-08-16016 August 1999 LER 99-019-00:on 990716,noted Victoreen Containment Hrrms Not Environmentally Qualified to Withstand post-LOCA Conditions.Caused by Inadequate Design Control.Reviewing Options to Support Hrrms Operability in Modes 1-4 ML17326A0771999-08-0404 August 1999 LER 98-029-01:on 980422,noted That Fuel Handling Area Ventilation Sys Was Inoperable.Caused by Original Design Deficiency.Radiological Analysis for Spent Fuel Handling Accidents in Auxiliary Bldg Will Be Redone by 990830 ML17335A5461999-08-0202 August 1999 Rev 0 to Evaluation of Cook Recirculation Sump Level for Reduced Pump Flow Rates. ML17326A0871999-07-31031 July 1999 Monthly Operating Rept for July 1999 for DC Cook Nuclear Plant,Unit 1.With 990812 Ltr ML17326A0861999-07-31031 July 1999 Monthly Operating Rept for July 1999 for DC Cook Nuclear Plant,Units 2.With 990812 Ltr ML17326A0741999-07-29029 July 1999 LER 99-018-00:on 990629,determined That Valve Yokes May Yield Under Combined Stress of Seismic Event & Static,Valve Closed,Stem Thrust.Caused by Inadequate Design of Associated Movs.Operability Determinations Were Performed for Valves ML17326A0661999-07-26026 July 1999 LER 99-017-00:on 990625,noted That Improperly Installed Fuel Oil Return Relief Valve Rendered EDG Inoperable.Caused by Personnel Error.Fuel Oil Return Valve Was Replaced with Valve in Correct Orientation.With 990722 Ltr ML17326A0651999-07-22022 July 1999 LER 98-014-03:on 980310,noted That Response to high-high Containment Pressure Procedure Was Not Consistent with Analysis of Record.Caused by Inadequate Interface with W. FRZ-1 Will Be Revised to Be Consistent with New Analysis ML17326A0491999-07-13013 July 1999 LER 99-016-00:on 990615,TS Requirements for Source Range Neutron Flux Monitors Not Met.Caused by Failure to Understand Design Basis of Plant.Procedures Revised.With 990713 Ltr ML17326A0331999-07-0101 July 1999 LER 99-004-01:on 971030,failure to Perform TS Surveillance Analyses of Reactor Coolant Chemistry with Fuel Removed Was Noted.Caused by Ineffective Mgt of Tss.Chemistry Personnel Have Been Instructed on Requirement to Follow TS as Written ML17326A0511999-06-30030 June 1999 Monthly Operating Rept for June 1999 for DC Cook Nuclear Plant,Unit 2.With 990709 Ltr ML17326A0501999-06-30030 June 1999 Monthly Operating Rept for June 1999 for DC Cook Nuclear Plant,Unit 1.With 990709 Ltr ML17326A0151999-06-18018 June 1999 LER 99-014-00:on 990521,determined That Boron Injection Tank Manway Bolts Were Not Included in ISI Program,Creating Missed Exam for Previous ISI Interval.Caused by Programmatic Weakness.Isi Program & Associated ISI Database Modified ML17325B6421999-06-0101 June 1999 LER 99-013-00:on 990327,safety Injection & Centrifugal Charging Throttle Valve Cavitation During LOCA Could Have Led to ECCS Pump Failure.Caused by Inadequate Original Design Application of Si.Throttle Valves Will Be Developed ML17325B6311999-06-0101 June 1999 LER 99-S03-00:on 990430,vital Area Barrier Degradation Was Noted.Caused by Inadequate Insp & Maint of Vital Area Barrier.Repairs & Mods Were Made to Barriers to Eliminate Degraded & Nonconforming Conditions ML17326A0061999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Dcp.With 990609 Ltr ML17326A0071999-05-31031 May 1999 Monthly Operating Rept for May 1999 for DC Cook Nuclear Plant,Unit 2.With 990609 Ltr ML17325B6351999-05-28028 May 1999 LER 99-S02-00:on 990428,vulnerability in Safeguard Sys That Could Allow Unauthorized Access to Protected Area Was Noted. Caused by Inadequate Original Plant Design.Mods Were Made to Wall Opening to Eliminate Nonconforming Conditions ML17265A8231999-05-24024 May 1999 LER 98-037-01:on 990422,determined That Ice Condenser Bypass Leakage Exceeds Design Basis Limit.Caused by Pressure Seal Required by Revised W Design Not Incorporated Into Aep Design.Numerous Matl Condition Walkdowns & Assessments Made ML17325B6001999-05-20020 May 1999 LER 99-012-00:on 990420,concluded That Auxiliary Bldg ESF Ventilation Sys Not Capable of Maintaining ESF Room Temps post-accident.Caused by Inadequate Control of Sys Design Inputs.Comprehensive Action Plan Being Developed ML17325B5861999-05-10010 May 1999 LER 99-002-00:on 990415,discovered That TS 4.0.5 Requirements Were Not Met Due to Improperly Performed Test. Caused by Incorrect Interpretation of ASME Code.App J Testing Will Be Completed & Procedures Will Be Revised ML17325B5811999-05-0404 May 1999 LER 99-011-00:on 990407,air Sys for EDG Will Not Support Long Operability.Caused by Original Design Error.Temporary Mod to Supply Makeup Air Capability in Modes 5 & 6 Was Prepared ML17325B5771999-05-0303 May 1999 LER 99-010-00:on 990401,RCS Leak Detection Sys Sensitivity Not in Accordance with Design Requirements Occurred.Caused by Inadequate Original Design of Containment Sump Level. Evaluation Will Be Performed to Clearly Define Design ML17335A5301999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for DC Cook Nuclear Plant,Unit 1.With 990508 Ltr ML17335A5291999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for DC Cook Nuclear Plant,Unit 2.With 990508 Ltr ML17325B5581999-04-16016 April 1999 LER 99-006-00:on 990115,personnel Identified Discrepancy Between TS 3.9.7 Impact Energy Limit & Procedure 12 Ohp 4030.STP.046.Caused by Lack of Design Basis Control.Placed Procedure 12 Ohp 4030.STP.046 on Administrative Hold ML17325B5471999-04-12012 April 1999 LER 99-009-00:on 990304,as-found RHR Safety Relief Valve Lift Setpoint Greater than TS Limit Occurred.Cause Investigation for Condition Has Not Been Completed.Update to LER Will Be Submitted,Upon Completion of Investigation ML17325B5321999-04-0707 April 1999 LER 99-S01-00:on 990308,discovered That Lock for Vital Gate Leading to Plant 4KV Switchgear Area Was Nonconforming & Vulnerable to Unauthorized Access.Caused by Inadequate Gate Design & Inadequate Procedures.Mods Are Being Made to Gate ML17325B5161999-04-0101 April 1999 LER 99-007-00:on 981020,calculations Showed That Divider Barrier Between Upper & Lower Containment Vols Were Overstressed.Engineers Are Currently Working on Analyses of Loads & Stress on Enclosures ML17325B5491999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for DC Cook Nuclear Plant Unit 2.With 990408 Ltr ML17325B5441999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for DC Cook Nuclear Plant,Unit 1.With 990408 Ltr ML17325B5221999-03-29029 March 1999 LER 99-001-00:on 960610,degraded Component Cooling Water Flow to Containment Main Steam Line Penetrations,Identified on 990226.Caused by Inadequate Understanding of Design Basis.Additional Investigations Ongoing ML17325B4801999-03-18018 March 1999 LER 99-004-00:on 971030,failure to Perform TS Surveillance Analyses of Rc Chemistry with Fuel Removed Was Noted.Cause of Event Is Under Investigation.Corrected Written Job Order Activities Used to Control SD Chemistry Sampling ML17325B4741999-03-18018 March 1999 LER 99-005-00:on 940512,determined That Rt Breaker Manual Actuations During Rod Drop Testing Were Not Previously Reported.Caused by Lack of Training.Addl Corrective Actions,Including Preventative Actions May Be Developed ML17325B5671999-03-0202 March 1999 Summary of Unit 1 Steam Generator Layup Chemistry from 980101 to 990218. ML17325B4631999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for DC Cook Nuclear Power Station,Unit 2.With 990308 Ltr ML17325B4621999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for DC Cook Nuclear Plant,Unit 1.With 990308 Ltr ML17325B4571999-02-24024 February 1999 LER 99-003-00:on 990107,CR Pressurization Sys Surveillance Test Did Not Test Sys in Normal Operating Condition.Caused by Failure to Recognize Door 12DR-AUX415 as Part of CR Pressure Boundary.Performed Walkdown of Other Doors 1999-09-30
[Table view] |
Text
4,C CElZ RATED DISTR( BUTION DEMONS 4,TION SYSTEM REGULATE ZNFORMATZON DT/STRZSUTZO SYSTEM (RZDS) 8((</(I ACCESSION NBR:8811180051 DOC.DATE: ~La4 NOTARIZED: NO DOCKET FACIAL:50-315 Donald C. Cook Nuclear Power Plant, Unit 1, Indiana & 05000315 AUTH. NAME AUTHOR AFFILIATION GILES,H. Indiana Michigan Power Co. (formerly Indiana & Michigan Ele HARNERFJ.W. Indiana Michigan Power Co. (formerly Indiana & Michigan Ele SMITHFW.G. Indiana Michigan Power Co. (formerly Indiana & Michigan Ele RECIP.NAME RECIPIENT AFFILIATION
SUBJECT:
Monthly operating rept for Oct 1988. /881107 1 r.
DISTRIBUTION CODE: IE24D COPIES RECEIVED:LTR Nl SIZE:
TITLE: Monthly Operating Report (per Tech Specs)
NOTES:
RECIPIENT COPIES REC1PIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD3-1 LA 1 0 PD3-1 PD 5 5 SCOTT,W 1 0 INTERNAL: AEOD/DOA 1 1 AEOD/DSP/TPAB 1 1 ARM TECH ADV 2 2 NRR/DLPQ/PEB 11 1 1 NRR/DOEA/EAB 11 1 1 NRRJ3RE PB 10 1 1 NUDOCS-ABSTRACT 1 1 ~ G FILE 01 1 1 RGN3 1 1 EXTERNAL EG&G S IMPSON F F 1 1 EG&G WILLIAMSFS 1 1 LPDR 1 1 NRC PDR 1 1 NSIC 1 1 R
I D
NOZE I0 ALL 'RIDS" RECIPIENTS:
S PLEASE HEH? US TO REDUCE WASTEl (XMRCT 'IHE DOCUMEPZ COPQRL DESK RQGN Pl-37 (EZT. 20079) KO EIZMZNATE KKR NAME PRCH DISTRIBUTION LISTS MR DOVIMEÃIS HXJ DGNFT NEED)
TOTAL NUMBER OF COPIES REQUIRED:. LTTR 22 ENCL 20
N.R.C. OPERATING DATA REPORT DOCKET NO. 50-315 DATE 01-NOV-88 COMPLETED BY H. Giles TELEPHONE 616-465-5901 OPERATING STATUS
- 1. Unit Name D. C. Cook Unit '1
- 2. Reporting Period OCT 88 ',notes
- 3. Licensed Thermal Power (MWt) 3250
- 4. Name Plate Rating (Gross MWe) 1152
- 5. Design Electrical Rating (Net MWe) 1030 'i
- 6. Maximum Dependable Capacity (GROSS MWe) 1056
- 7. Maximum Dependable Capacity (Net MWe) 1020
- 8. If Changes Occur in Capacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons
- 9. Power Level To Which Restricted.
If If Any (Net MWe)
- 10. Reasons For Restrictions. Any:
This Mo. Yr. to Date Cumm.
- 11. Hours in Reporting Period 745.0 7320.0 -.121272.0
- 12. No. of Hrs. Reactor Was Critical 672 8 ~ 6997 ' 88835.3
- 13. Reactor Reserve Shutdown Hours 0.0 0.0 463.0
- 14. Hours Generator on Line 660.0 6961.9 . 87199.4
- 15. Unit Reserve Shutdown Hours 0.0 0.0 321.0
- 16. Gross Therm. Energy Gen. (MWH) 1854946 20101392 253100390
- 17. Gross Elect. Energy Gen. (MWH) 589160 64S5680 82610350
- 18. Net Elect. Energy Gen. (MWH), 564727 6211779 79442777
- 19. Unit Service Factor 88.6 95.1 73.1
- 20. Unit Availability Factor 88. 6 95.1 73.1
- 21. Unit Capacity Factor (MDC Net) 74. 3 83.2 65.3
- 22. Unit Capacity Factor (DER Net) 73. 6 82.4 63.3
- 23. Unit Forced Outage Rate 11.4 4 4 8.1
- 24. Shutdowns Scheduled over Next Six Months (Type, Date,and Duration)-
Unit 1 C cle 10-11 Refuel 'n MJLCXRIlf Februar 15 1989.
- 25. If Shut Down At End of Report Period, Estimated Date of Startup:
- 26. Units in Test Status (Prior to Commercial Operation)-
Forcast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION 88i 18005f PDR i ADO~< 881031' 05000315 PblU gE~9 I
i//
AVERAGE DAILY POWER LEVEL (MWe-Neh)
DOCKET NO. 50-315 UNIT ONE DATE 01-NOV-88 COMPLETED BY H. Giles TELEPHONE 616-465-5901 MONTH OCT 88 AVERAGE DAILY AVERAGE DAILY DAY POWER LEVEL DAY POWER LEVEL 1 896 17 898 2 899 18 899 3 899 19 539 4 900 20 231 5 898 21 829 6 896 22 902 7 897 23 901 8 897 24 899 9 899 25 900 10 896 26 899 11 564 27 903 12 0 28 903 13 0 29 903 14 61 30 903 15 616 31 902 16 900
50-3 V UNIT SIIIITI)()IVNSANI) PO)VI!lt l(EI)U('TIONS I)0(:K ET N().
UNIT Nhh(E l)ATE
~~ok 11-07-88 Unit 1
(:OhfPI.ETI:I) IlY It Ei'0(t I'lii)NTII ~raaEII Paelof2 pi<<l C<<
C I I.ILc<<scc Ew 8, g 0+ ( a<<sc A ('i>>ieLllvc l)vlc 4 I:Ye<<i Ul Q O
40 Ai:Iii<<I I il I- Itcpiifl ll III' Cg O I lcvcnl ltcL'<<Ill'nl.'c O
Cl 273 881011 68.1 . H 88-010-00 CJ XXXXXX The unit was shutdown as a precau-tionary measure due to concerns with the enviromental qualifications of the reactor vessel head vent and the Ipressurizer steam space vent solenoid valves conduit installatio being less than optimum.- A design change was implemented'to correct the conduit installation to meet enviromental qualification require-lie ments. The unit was returned to service 10-14-88 at 1748 hrs and reached 90X power (administrative power limit) on 10-15-88.
I". I'I>>LcLI Iteason: hiclh<<il' I:xhlhil (i hlsll<<clliins S: SLheililleil A hl<<iplnenl I'nih<<c (f:xplcin) hfQ<<<<QI fill I fepli<<Ih<<i.ail I)'lid I) hl<<i<<icninlce i>i 'I'esl 2'Mill<<lillSCIL<<l. I:Iilly Sliccls ii<< I.ILcnsi'.c
('. Itc(<<clhii) .'I.holi><<lniic Scl'>>ll. Iivcill I I.I'lI I'ilc (Nl litI'.(i I) Itcl;<<41<<Iy lti.slficii<<n ~ I ()lhcl (Iixplai<<) I) I hi )
I'.Opcl<<l<<l I llhlhlti4 license I:xll<<hlalh<<I I'lln)inlsll:llivc (I ()pcIQlhlnxl I II<>) I xhlhil I S.>><<c Si>>>>ic
(')I >7 ) II ()ihcl (I'.xplahI)
I)0(:KET NO. 50-3a UNIT SIIU fl)()IYNS ANI) POI>tilt It I I)II( 1'IONS UNIT NAhlE
~D ~njs Unit LLOiJM-(:Oh(PI.ETI:.I) ltY it(.:I'AltT hIII)N'fII~ZPZZB
.Page 2 of 2 Ch ~ 6 g J l.ice<<see Ew O 0
(>>nsc tt> ( I>>rcclivc.
Ni>. Ibte )!vent ~
Ul Q I> Acti>>n I>>
ltep<<rl It Il>' L- v I'reve<n>>renee Cr A
274 881019 16. 9 .A 3 88-0 1 1-00 lA A reactor trip occurred, .caused by a spurious reactor coolant pump breaker open indication (k trip coincidence) that was induced by a failed power available bulb on a solid state protection system cabinet. After repairs the unit was returned to service on 10-20-88 at 0820 hours0.00949 days <br />0.228 hours <br />0.00136 weeks <br />3.1201e-4 months <br /> and reached 90% power (administrative power limit) on 10-21-88.
I': I>r>>cc>I lte>>s<<rl: hlcthn>l: I xhil>il () ~ lost t<<eth>ns S: Sche>h>le>l A I:II<<lplncnt I'>>ih>te {Expbin) I hl>>n<<>>I fi>r I>lcp>>>>: thn>>>I') >to I) hblntcn>>nee <><<<<>>I Ser>>nl. I:ntlg Shccls fn> I.icellscc
('.Itef<<cih>II .I A<<I<<n>>>lic SI;Ii>n>. I'.vent ltcp(<<l II.I'.ll)I'ii>> IN) litli(>~
I) Itc)I<<l>>t<<>y ftcslrlclinn ~ l.()lh>>> (Iixpbin) III(> I )
I: Ope>>>tl>I I'l>>inh>IIX I)cense I:x>>><<In>>th<<>
I'>ln>inirtt>>live (I ()pcr>>ii>><I I:Il>>l (I:xl>linn) Txh>lilt I Ii>n'>>>>>><<l>L II ()lhct Ilixpbin)
DOCKET NO: 50-315 UNIT NAME: D. C. Cook Unit 1 COMPLETED BY: J. W. Harner TELEPHONE: (616) 465-5901 DATE: Nov. 7, 1988 PAGE: lof 2 MONTHLY OPERATING ACTIVITIES - OCTOBER 1988 H
HIGHLIGHTS:
The unit entered the reporting period at the administrative power limit of 90Ã. On October 10, 1988 the unit was shut down as a precautionary measure due to concerns with the environmental qualifications of the reactor vessel head vent and the pressurizer steam space vent solenoid valves conduit installation being less than optimum. A design change was implemented to correct the conduit installation to meet environmental qualification requirements. The unit was returned to service 10-14-88 at 1748 hrs and reached 90K power (administrative power limit) on 10-15-88.
On October 19, 1988 a reactor trip occurred, caused by a spurious reactor coolant pump breaker open indication (1/4 trip coincidence) that was induced by a failed power available bulb on a solid state protection system cabinet.
After repairs the unit was returned to service on 10-20-88 at 0820 hours0.00949 days <br />0.228 hours <br />0.00136 weeks <br />3.1201e-4 months <br /> and reached 90% power (administrative power limit) on 10-21-88.
The reporting period ended with the unit operating at the 90% administrative power limit.
Gross electrical generation for the month of October, 1988 was 589,160 MWH.
DETAILS 10-11-88 1045 Started reactor shutdown due to environmental concerns with the reactor vessel head vent and pressurizer steam space vent solenoid valves conduit installation.
1048 During the shutdown the normal boration lines were found to be inoperable due to blockage.
1146 The questioned vent valves were tagged closed and de-energized to comply with the technical specification action statement.
2140 Turbine generator removed from parallel by manual turbine trip.
2208 RCS entered Mode 3.
4 10-12-88 0645 Reactor coolant system cooldown was stopped at approximately 360'F.
10-14-88 1046 Reactor critical.
1748 Unit paralleled to the grid.
10-15-88 2055 Reactor power at 905.
10-19-88 1522 Reactor trip occurred caused by a spurious reactor coolant pump breaker open indication.
10-20-88 0252 Reactor critical.
0820 Unit paralleled to the grid.
1720 Reactor power held at 485 for excessive quadrant power tilt ratio.
2223 Resumed reactor power ascension to 905.
10-21-88 1040 Reactor power at 90%.
10-24-88 1715 The incore flux detector thimble tube leak detection system started alarming (The thimble J-1 was determined to be leaking.
The tube was cut and capped on 10-25-88 which provided complete isolation of leak).
DOCKET NO. 50-315 UNIT NAME . Cook - Unit Mo. 1 DATE Nov. 7, 1988 COMPLETED BY TELEPHONE 616 465-5901 PAGE 1 o 1 MAJOR SAFETY-RELATED MAINTENANCE OCTOBER 1988 The secondary side manway cover of the No. 4 steam generator was leaking. Leak repair was successfully performed by Furmanite injection.
Leak on incore flux detector thimble J-1 was repaired by cutting and capping the thimble tube.
724030: The 1CD-2 battery charger will not mainta'in load and voltage.
Found the current control module to be defective. Replaced module and adjusted the voltage.
735597: The quick exhaust valve on XRV-221 starting air valve on Unit 1AB diesel generator has a gasket leak.
Replaced with a new one.
735541: The 1CD diesel generator trip control cylinder is fully extended with no trip signal to energize.
Found regulator defective and replaced with a new one.
q4 Indiana Michigan Power Company Cook Nuclear Plant P.O. Box 458 Bridgrnn, Ml 49106 616 465 5901 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 November 7, 1988 Gentlemen:
e
~
~ q~ 'll Pursuant to the requirements of Donald'. Cook Nuclear Plant Unit 1 Technical Specification 6.9. 1. 10, the attached Monthly Operating Report for the month of October 1988 is submitted.
Sincerely, W. . mi Plant Manager WGS/jd CC: D. 'H; Williams, Jr.
M. P. Alexich C. A. Erikson J. J. Markowsky D. A. Timberlake R. F. Kroeger B. L. Jorgensen M. J. Parvin J. R. Sampson E. A. Smarrella Dolly Krieger T. R. Stephens D. S. Climer R. C. Callen D. W. Paul D. R. Hahn S. L. Hall INPO Records Center ANI Nuclear Engineering Department NRC Region III EPRI--Nuclear Safety Analysis Center