MONTHYEARML15022A1652015-01-0909 January 2015 License Amendment Request for Areva Extended Flow Window Supplement to Respond to NRC Staff Questions Project stage: Supplement ML15030A0092015-01-28028 January 2015 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance Review for License Amendment Request Transition to Areva Extended Flow Window Methodology Project stage: Acceptance Review ML15195A4472015-08-0505 August 2015 Summary of Public Meeting with Xcel Energy and Areva to Discuss Changes to the Proposed Technical Specifications and COLR in Support of the Areva Extended Flow Window License Amendment Request Project stage: Meeting L-MT-15-057, License Amendment Request for Areva Extended Flow Window Supplement to Respond to NRC Staff Questions2015-08-26026 August 2015 License Amendment Request for Areva Extended Flow Window Supplement to Respond to NRC Staff Questions Project stage: Supplement ML15140A1242015-09-28028 September 2015 Request for Withholding Information from Public Disclosure from Areva Inc. Associated with the Areva Extended Flow Window License Amendment Request Project stage: Withholding Request Acceptance ML15140A1472015-09-28028 September 2015 Request for Withholding Information from Public Disclosure (GE-Hitachi LLC) Associated with the Areva Extended Flow Window License Amendment Request Project stage: Withholding Request Acceptance ML15274A4732015-09-29029 September 2015 License Amendment Request for Areva Extended Flow Window Supplement to Respond to NRC Staff Questions Project stage: Supplement L-MT-15-065, Enclosure 8, Areva Report ANP-3424NP, Revision 1 to Areva Responses to RAI from Scvb on MNGP EFW LAR (Non-Proprietary) and Enclosure 9, Areva Affidavits2015-09-29029 September 2015 Enclosure 8, Areva Report ANP-3424NP, Revision 1 to Areva Responses to RAI from Scvb on MNGP EFW LAR (Non-Proprietary) and Enclosure 9, Areva Affidavits Project stage: Response to RAI ML15274A4752015-09-29029 September 2015 Enclosure 6, Areva Report ANP-3435NP, Revision 0 to Are VA Responses to RAI-8 and RAI-32 from Srxb and Snpb on MNGP EFW LAR (Non-Proprietary) Project stage: Response to RAI ML15274A4742015-09-29029 September 2015 Enclosure 4, Engineering Evaluation, EC 25987, Calculation Framework for the Extended Flow Window Stability (Efws) Setpoints Project stage: Other L-MT-15-081, ANP-3435NP, Revision 1, Areva Responses to RAI-8 and RAI-32 from Srxb and Snpb on MNGP EFW Lar.2015-12-0808 December 2015 ANP-3435NP, Revision 1, Areva Responses to RAI-8 and RAI-32 from Srxb and Snpb on MNGP EFW Lar. Project stage: Response to RAI ML15345A4072015-12-0808 December 2015 License Amendment Request for Areva Extended Flow Window, Supplement to Provide Revised Analysis of Anticipated Transient Without Scram Instability Project stage: Supplement ML16063A0332016-02-29029 February 2016 License Amendment Request for Areva Extended Flow Window Supplement to Disposition Changes to Non-Limiting Transient Analyses Project stage: Supplement L-MT-16-017, Revised Commitment to Reconcile Analysis of Bypass Voiding for Transition to Areva Analysis Methodology2016-04-29029 April 2016 Revised Commitment to Reconcile Analysis of Bypass Voiding for Transition to Areva Analysis Methodology Project stage: Other ML16221A2742016-07-31031 July 2016 ANP-3435NP, Revision 2, Areva Responses to RAI-8 and RAI-32 from Srxb and Snpb on MNGP EFW Lar. Project stage: Response to RAI L-MT-16-037, ANP-3284NP, Revision 1, Results of Analysis and Benchmarking of Methods for Monticello ATWS-I.2016-07-31031 July 2016 ANP-3284NP, Revision 1, Results of Analysis and Benchmarking of Methods for Monticello ATWS-I. Project stage: Other ML16221A2752016-07-31031 July 2016 ANP-3274NP, Revision 2, Analytical Methods for Monticello ATWS-I. Project stage: Other ML16221A2732016-08-0404 August 2016 License Amendment Request for Areva Extended Flow Window Supplement to Provide Revised Analysis of Anticipated Transient Without Scram Instability Project stage: Supplement L-MT-16-041, License Amendment Request for Areva Extended Flow Window Supplement to Address Power Distribution Uncertainties2016-09-14014 September 2016 License Amendment Request for Areva Extended Flow Window Supplement to Address Power Distribution Uncertainties Project stage: Supplement L-MT-16-049, License Amendment Request for Areva Extended Flow Window Supplement to Revise the Applicability of a Topical Report Limitation2016-09-28028 September 2016 License Amendment Request for Areva Extended Flow Window Supplement to Revise the Applicability of a Topical Report Limitation Project stage: Supplement 2015-09-29
[Table View] |
|
---|
Category:Meeting Summary
MONTHYEARML23313A1592023-11-0909 November 2023 U.S. Nuclear Regulatory Commission Summary of the October 10, 2023, Public Meeting to Discuss Monticello'S Condensate Backwash Receiving Tank Fatigue Evaluation ML23275A0222023-10-0505 October 2023 Summary of September 21, 2023, Public Meeting with Northern States Power Company Regarding Proposed License Amendment Request to Revise the Pressure Temperature Limits Report ML23200A2602023-07-20020 July 2023 Summary of July 14, 2023, Public Meeting with Northern States Power Company Regarding Proposed Alternative to Defer Periodic Verification Testing of Reactor Water Clean-Up Inboard Isolation Valve ML23157A0432023-06-0808 June 2023 Summary of Public Outreach to Discuss the NRC 2022 End-Of-Cycle Plant Performance Assessment of Monticello Nuclear Generating Plant ML23110A0142023-05-0101 May 2023 Memo March 22, 2023, Monticello Unit 1, Subsequent License Renewal Application Public Environmental Scoping Meeting ML23110A0152023-05-0101 May 2023 Summary March 22, 2023, Monticello Units 1 Subsequent License Renewal Application Public Environmental Scoping Meeting ML23115A4382023-05-0101 May 2023 March 29, 2023, Meeting Summary for Environmental Review of Subsequent License Renewal Application for Monticello Nuclear Generating Plant, Unit 1 ML23115A4642023-05-0101 May 2023 Summary, March 29, 2023, Monticello Units 1 Subsequent License Renewal Application Public Environmental Scoping Meeting ML23074A1212023-04-0303 April 2023 March 8, 2023, Summary of Public Meeting with Northern States Power Company Regarding Monticello Nuclear Generating Plant Alternative Request PR-08 to Defer Quarterly Testing of Components of High Pressure Coolant Injection System ML22292A0122022-10-24024 October 2022 Meeting Summary for Environmental Pre Submittal Meeting for Subsequent License Renewal Application, on September 13, 2022 ML22208A2192022-08-0303 August 2022 Summary of July 25, 2022, Meeting with Northern States Power Company, Doing Business as Xcel Energy, Related to the Amendment to Adopt Advanced Framatome Inc. Methodology for Determining Core Operating Limits for Monticello Plant ML22208A1952022-08-0303 August 2022 Summary of July 26, 2022, Meeting with Northern States Power Company, Doing Business as Xcel Energy, Related to the Alternative Request for Excess Flow Check Valves at Monticello Nuclear Generating Plant ML22130A7172022-05-10010 May 2022 Summary of the May 3, 2022, Public Outreach to Discuss the NRC 2021 End-Of-Cycle Plant Performance Assessment of Monticello and Prairie Island Nuclear Generating Plant, Units 1 and 2 ML22084A3852022-03-31031 March 2022 Meeting Summary for Environmental Pre Submittal Meeting for Subsequent License Renewal Application on March 15, 2022 ML22032A0112022-02-0303 February 2022 Summary of January 27, 2022, Meeting with Northern States Power Company, Doing Business as Xcel Energy, Related to a Planned Relief Request to Test Excess Flow Check Valve ML21285A0312021-10-15015 October 2021 Summary of Meeting with Northern States Power Company, Doing Business as Xcel Energy, Related to Planned License Amendment to Extend Allowed Outage Time for Fuel Oil Storage Tank for Monticello Nuclear Plant ML21167A1842021-06-16016 June 2021 Summary of the June 9, 2021, Public Outreach to Discuss the NRC 2020 End-Of-Cycle Plant Performance Assessment of Monticello Nuclear Generating Plant and Prairie Island Nuclear Generating Plant, Units 1 and 2 ML21098A0742021-04-13013 April 2021 Summary of March 25, 2021, Meeting with Northern States Power Company, Doing Business as Xcel Energy, Related to a Planned License Amendment to Adopt Advanced Framatome Methods ML21040A4612021-02-11011 February 2021 Summary of February 3, 2021, Meeting with Northern States Power Company, Doing Business as Xcel Energy, Related to a Planned License Amendment to Combine the Emergency Plans and Create a Common Emergency Operations Facility ML20281A5092020-10-16016 October 2020 Summary of October 2, 2020, Meeting with Northern States Power Company, Doing Business as Xcel Energy, on Potential Amendment to Revise the Safety Limit Minimum Critical Power Ratio for Monticello Nuclear Generating Plant ML20218A4462020-08-0505 August 2020 Summary of the July 16, 2020 Public Outreach to Discuss the NRC 2019 End-of-Cycle Plant Performance Assessment of Monticello Nuclear Generating Plant ML20077L8312020-03-20020 March 2020 Summary of February 27, 2020, Meeting with Northern States Power Company, Doing Business as Xcel Energy, on Potential License Amendment to Adopt TSTF-505 Provide Risk-Informed Completion Times - RITSTF Initiative 4b ML19130A1672019-05-14014 May 2019 May 8, 2019 Summary of Teleconference with Northern States Power Company, Doing Business as Xcel Energy, to Discuss a Response to a Request for Additional Information Related to the License Amendment Request to Adopt 10 CFR 50.69 ML18046B2072018-02-26026 February 2018 Summary of February 8, 2018, Meeting with Northern States Power Company, Doing Business as Xcel Energy, on Potential Exemption from Fire Protection Requirements at Monticello Nuclear Generating Plant Units 1 and 2 ML17353A0242018-01-0202 January 2018 Summary of December 12, 2017, Teleconference with Northern States Power Company, Doing Business as Xcel Energy, on Potential License Amendment Request to Adopt TSTF-425 ML17341A1292017-12-11011 December 2017 Summary of Meeting with Northern States Power Company, Doing Business as Xcel Energy, on Changes to the Security Plans at the Monticello Nuclear Generating Plant and Prairie Island Nuclear Generating Plant, Units 1 and 2 ML17300A0362017-10-31031 October 2017 Summary of Meeting with Northern States Power Company, Doing Business as Xcel Energy, on Potential License Amendment Request Related to Emergency Diesel Generator Technical Specifications ML17270A0072017-09-29029 September 2017 Summary of Teleconference with Northern States Power Company, Doing Business as Xcel Energy, on Potential License Amendment Request to Adopt TSTF-542 Reactor Pressure Vessel Water Inventory Control ML17235B1542017-08-23023 August 2017 July 11, 2017,Summary of the Open House to Discuss the 2016 End-Of-Cycle Plant Performance Assessment of Monticello ML17090A2442017-04-0606 April 2017 Summary of February 28, 2017, Meeting with Northern States Power Company, Doing Business as Xcel Energy, on the Integrated Leak Rate Test License Amendment Request for Monticello Nuclear Generating Plant CAC No. MF7359) ML17034A1202017-02-0909 February 2017 Summary of January 24, 2017, Meeting with Northern States Power Company, Doing Business as Xcel Energy, on Potential Revision to the Emergency Action Level ML16334A0112016-12-0606 December 2016 Summary of Meeting with Northern States Power Company, Doing Business as Xcel Energy, on Potential Exemption Request from Fire Protection Requirements ML16172A0662016-06-20020 June 2016 Summary of the May 26, 2016, Monticello Public Meeting ML15271A2072015-10-0202 October 2015 July 9, 2015 Summary of Closed Meeting Between Representatives of the U.S. Army Corps of Engineers, U.S, Nuclear Regulatory Commission and Northern States Power Company- Minnesota to Discuss Flood Analysis Associated with Monticello Nuclear ML15195A4472015-08-0505 August 2015 Summary of Public Meeting with Xcel Energy and Areva to Discuss Changes to the Proposed Technical Specifications and COLR in Support of the Areva Extended Flow Window License Amendment Request ML15093A2342015-04-0303 April 2015 Summary of Monticello Public Meeting ML14297A1272014-10-31031 October 2014 Summary of October 1, 2014, Public Meeting with NSPM and Areva to Discuss Areva Fuel Transition License Amendment Request and Future License Amendment Application Regarding Use of Areva Atrium 10XM Fuel in Extended Flow Window Domain ML14220A2832014-09-0808 September 2014 Summary of August 5, 2014, Closed Meeting Between Representatives of the U.S. Army Corps of Engineers, NRC, and Northern States Power Company - Minnesota to Discuss Flooding Analysis Associated with Monticello and Prairie Island Nuclear Gen ML14153A0252014-06-20020 June 2014 Meeting Summary - Public Meeting on May 16, 2014, to Discuss Xcel Energy'S Flood Hazard Reevaluation Extension Request for the Monticello and Prairie Island Nuclear Generating Plants ML14168A0182014-05-16016 May 2014 Xcel Energy Responses to NRC Questions Regarding Flood Hazard Reevaluation Report Extension Requests ML14111A0352014-04-21021 April 2014 Summary of Monticello Public Meeting to Discuss the 2013 Annual Assessment Results ML13351A3422013-12-30030 December 2013 December 4, 2013 Summary of Public Meeting with Northern States Power Company of Minnesota to Discuss the Future License Amendment Application Regarding the Use of Areva Atrium 10XM Fuel in Extended Flow Window Operating Domain ML13171A1522013-06-24024 June 2013 April 24, 2013, Summary of Public Meeting in City of Kewaunee to Make Post-Shutdown Decommissioning of Activities Report (PSDAR) Available for Public Comment ML13169A0352013-06-14014 June 2013 Email Miller to Wilson Summary of Call with Monticello Flooding Audit ML13135A0312013-05-31031 May 2013 Summary of May 3,2013, Conference Call with Northern States Power Company - Minnesota (NSPM) to Discuss Application of 10 CFR 26.205(d)(6) During the Current Refueling Outage ML12338A0062012-12-13013 December 2012 November 20, 2012, Summary of Public Meeting with Northern States Power Company of Minnesota to Discuss the Extended Power Uprate Gap Analysis ML12188A2582012-07-20020 July 2012 Summary of Meeting with Monticello Regarding a Future Amendment to Approve Use of Areva Atrium 10XM Fuel ML12093A4772012-05-0101 May 2012 April 2, 2012, Summary of Meeting with NSPM to Discuss Issue Related to Containment Accident Pressure Credit for Extended Power Uprate Operation ML12017A0852012-02-10010 February 2012 1/17/12 Summary of Meeting with Monticello a Future Application for Amendment Concerning Stored Fuel Criticality Analysis ML11292A1612011-10-20020 October 2011 Summary of Meeting with Beyond Nuclear Regarding Their 10 CFR 2.206 Petition to Suspend Operating Licenses of General Electric Mark I Boiling Water Reactors 2023-07-20
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 August 5, 2015 LICENSEE: Xcel Energy FACILITY: Monticello Nuclear Generating Plant
SUBJECT:
SUMMARY
OF THE JULY 7, 2015, PUBLIC MEETING WITH XCEL ENERGY AND AREVA TO DISCUSS CHANGES TO THE PROPOSED TECHNICAL SPECIFICATIONS AND CORE OPERATING LIMITS REPORT IN SUPPORT OF THE AREVA EXTENDED FLOW WINDOW LICENSE AMENDMENT REQUEST REVIEW (TAC NO. MF5002)
On July 7, 2015, the U.S. Nuclear Regulatory Commission (NRC) staff held a Category 1 public meeting with representatives of Northern States Power Company - Minnesota, doing business as Xcel Energy (the licensee), and AREVA, at NRC headquarters. The purpose of the meeting was for the licensee to discuss potential changes to the Technical Specifications (TSs) and Bases, and Core Operating limits Report (COLR), supporting the AREVA Extended Flow Window (EFW) license amendment request (LAR) for the Monticello Nuclear Generating Plant (Monticello) dated October 3, 2014 (Agencywide Documents Access and Management System (ADAMS) Accession No. Ml 14283A119), that is currently under NRC staff review. The proposed changes would, in part, allow Xcel Energy to better implement the Reactor Protection System features that enforce Enhanced Option Ill (E0-111) long-term stability.
The licensee's presentation followed handout material provided during the meeting and is available at ADAMS Accession No. ML15196A019. The licensee indicated during the meeting that the information provided in its presentation may be made publicly available.
Xcel Energy described the background for this meeting as a follow-up to the NRC staff's audit at the AREVA facilities in Richland, Washington, during the week of June 13, 2015. During the audit, the staff had some questions regarding the proposed TSs in support of its review of the October 3, 2014, LAR.
Xcel Energy presented a series of flow charts (ADAMS Accession No. ML15196A019, first four pages) that explained the regulatory bases and precedent to support the TS revisions proposed in the LAR. The supporting regulatory bases include the Boiling Water Reactor Owners Group (BWROG) Option Ill licensing topical report (LTR) NED0-31960-A and AREVA LTR ANP-10262-P-A for E0-111. The licensee further described how the TSs would be implemented, including the means to "initiate alternate methods" (in TS Required Action 1.1), and stated that these methods are further described by the TS Bases and procedures, employing the same methods that have been widely used by those implementing Option Ill long-term stability solution (including Monticello prior to implementation of MELLLA+ [Maximum Extended Load line limit Analysis Plus]).
Meeting points of discussion and comments are summarized below:
- Xcel Energy briefly discussed that the phrase to "Exit Region 1 Immediately" (page 2 of flow charts) customarily means to initiate the action promptly (e.g., do not delay initiating action for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />).
- Xcel Energy discussed what the "backup solution" as described in the E0-111 LTR means and how Monticello was intending to implement it. The licensee noted that the E0-111 LTR provided an example only. As specified in the E0-111 SER, any specific proposed backup solution needed NRC approval on a plant-specific basis.
- Xcel Energy discussed the E0-111 SER requirement to provide automatic protection in the event of a Two Recirculation Pump Trip (2RPT) when operating in the EFW domain.
The licensee expanded its explanation that 2RPT protection is provided by the Extended Flow Window Stability (EFWS) trip ("the red line"), which provides a scram during the course of the power-flow trajectory for a 2RPT.
- Xcel Energy explained that the EFWS trip would be armed in the EFW region and the MELLLA region with the same setpoints, even though the E0-111 SER does not require the EFWS trip to be armed outside the EFWS region.
- Xcel Energy discussed the control board indication for the EFWS trip setpoint being "on" or "armed". The current indication consists of backlighting a small "ABSP [Automatic Backup Stability Protection]" on the top line of the PRNM [power range neutron monitor]
NUMAC [Nuclear Measurement Analysis and Control] C-05 display. The licensee acknowledged that this indication could be difficult to see and stated that it would take an action to explore whether the addition of a computer alarm or point would enhance this indication for plant operators.
A similar question was raised regarding indication that the EFWS trip was being approached. After discussion, there appeared to be agreement that the corresponding Rod Block would serve as an adequate alarm and be enforced by the RMCS [reactor manual control system].
- There was discussion regarding how much of the Natural Circulation Line (NCL) should be protected. The NRC staff suggested that it should be protected to at least the intersection of the NCL and Region-I (the Immediate Scram Region), to be consistent with the intent of original Intermediate Corrective Actions. AREVA provided assurance that the methodology provides such coverage.
- In TS Table 3.3.1.1-1, Function 2.g, there appeared to be agreement that enforcement of EFWS trip was better when the stated region of applicability was "above the MELLLA line" rather than "within the EFW region".
- The NRC staff indicated an interest in adding an action such as "confirm EFWS/ABSP is on" whenever the Oscillation Power Range Monitors (OPRMs) are inoperable. The staff noted that inoperable OPRMs should now be a rare occurrence, unlike earlier days when problems with the calculation models were sometimes discovered.
- The NRC staff expressed concern that the requirement for turning "on" or "arming" the EFWS trip above and below the MELLLA line could result in a distraction to plant operators if it was being switched on/off as the plant was maneuvered around this line.
The staff discussed the possibility of an arrangement such that the EFWS trip would be left "on" above some constant power level that would bound the MELLLA line, but that would not be so high as to routinely be crossed during plant maneuvering. The licensee explained that if it is "on" at a power that is too low, then startup maneuvering is severely challenged due to the intersection with the "ARTS [Average Power Range Monitor/Rod Block Monitor/Technical Specifications]" region, the NCL, and the feedwater flow interlock.
It was further noted by the licensee that plant operators would typically want a margin to a requirement, so that, for example, if this requirement was established at 50 percent RTP [rated thermal power], then plant operators would typically implement it at 40 percent RTP.
The licensee provided a markup of draft TS pages (refer to ADAMS Accession No. ML15196A019, last 11 pages) to describe the incremental changes to TS 5.6.3 to restore the Backup Stability Protection (BSP) Regions I and II to the power-flow map in the COLR. The licensee explained that these regions were mistakenly removed in the LAR marked-up pages.
Xcel Energy described the inclusion of a new, yet-unreleased, document reference to TS 5.6.3 that would describe the methodology used to develop the EFWS trip setpoints. The NRC staff recommended that any such document be docketed and include the necessary "calculational framework." Xcel Energy explained that the "calculational framework" document would describe the drive flow I core flow correlation method, any uncertainties, the method for combining uncertainties, and inclusion of the BSP region. The licensee also suggested that the Technical Requirements Manual could be supplemented to describe the General Electric setpoint methodology.
Specific points of discussion:
- 1. NRC was amenable to the proposed addition of Reference 6 under TS 5.6.3.b. The staff understood the argument for a document that would not have frequent revision updates.
- 2. Xcel Energy suggested that TS 5.6.3.c provided sufficient constraint to ensure that the most conservative Operating Limits (i.e., OPRM setpoints) for either the Option Ill or the E0-111 calculations are established. However, NRC staff was not convinced and asked if the AREVA method could be shown to bound the other method.
The licensee indicated it had clarification questions for the NRC staff in the Containment and Ventilation Branch and Instrumentation & Controls Branch regarding requests for additional information. It was suggested that a telephone conference be scheduled with the NRC staff at a later date to discuss the questions. A conference call was subsequently held on July 21, 2015.
The Enclosure to this meeting summary contains the list of participants.
Before the meeting adjourned, all meeting participants were given the opportunity to comment on any aspects of the meeting.
Mr. Marvin Lewis, a member of the public participating via the teleconference conference bridge, expressed a concern regarding the meaning and applicability of a Completion Time of "Immediately" identified within the Monticello Technical Specifications. Mr. Lewis also questioned the accessibility of these TS documents to other parties, if these documents were only available to Monticello, and how others would know to take the actions "immediately" if the TS documents were only available at Monticello. The NRC staff responded to Mr. Lewis's concerns in an e-mail dated July 8, 2015 (ADAMS Accession No. ML15196A011 ).
No regulatory decisions or commitments were made during the meeting. There were no members of the public in attendance at the meeting at NRC headquarters. There were three participants on the telephone conference line. The NRC staff received no meeting feedback forms.
Please direct any inquiries to me at 301-415-3049 or e-mail Terry.Beltz@nrc.gov.
/
Terry A. Beltz, Senior Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No.: 50-263
Enclosure:
List of Participants cc w/encl: Distribution via ListServ
LIST OF PARTICIPANTS U.S. NUCLEAR REGULATORY COMMISSION (NRC) PUBLIC MEETING WITH XCEL ENERGY AND AREVA TO DISCUSS THE LICENSE AMENDMENT REQUEST REGARDING AREVA EXTENDED FLOW WINDOW MONTICELLO NUCLEAR GENERATING PLANT NAME ORGANIZATION Glenn Adams Xcel Energy Terry Beltz NRC/NRR/DORL/LPL3-1 1 Josh Borromeo NRC/NRR/DSS/SRXB2 Margaret Chernoff NRC/NRR/DSS/STSB3 Christopher Jackson NRC/NRR/DSS/SRXB2 Tamara Malaney Xcel Energy Jose March-Leuba Oak Ridge National Laboratory (NRC consultant)
Alan Meginnis AREVA Mathew Panicker NRC/NRR/DSS/SNPB4 Harold Paustian Xcel Energy David Pelton NRC/NRR/DORL/LPL3-1 1 Diego Saenz NRC/NRR/DSS/SRXB 2 Ahsan Sallman NRC/NRR/DSS/SRXB5 Rick Stadtlander Xcel Energy George Thomas NRC/NRR/DSS/SRXB2 Dan Tinkler AREVA The following individuals participated by telephone:
John Elam Duke Energy Guy Jacks Duke Energy Marvin Lewis Member of Public Harold Scott NRC/RES/DSA/FSCB6 1
Office of Nuclear Reactor Regulation, Division of Operating Reactor Licensing, Plant Licensing Branch 111-1 2
Office of Nuclear Reactor Regulation, Division of Safety Systems, Reactor Systems Branch 3
Office of Nuclear Reactor Regulation, Division of Safety Systems, Technical Specifications Branch 4 Office of Nuclear Reactor Regulation, Division of Safety Systems, Nuclear Performance and Code Review Branch 5 Office of Nuclear Reactor Regulation, Division of Safety Systems, Containment and Ventilation Branch 6 Office of Nuclear Regulatory Research, Division of Systems Analysis, Fuel and Source Term Code Development Branch Enclosure
ML15196A011).
No regulatory decisions or commitments were made during the meeting. There were no members of the public in attendance at the meeting at NRC headquarters. There were three participants on the telephone conference line. The NRC staff received no meeting feedback forms.
Please direct any inquiries to me at 301-415-3049 or e-mail Terry.Beltz@nrc.gov.
IRA/
Terry A. Beltz, Senior Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No.: 50-263
Enclosure:
List of Participants cc w/encl: Distribution via ListServ DISTRIBUTION:
PUBLIC RidsNrrLAKGoldstein Resource D. Saenz, NRR LPL3-1 R/F RidsNrrMHenderson Resource G. Thomas, NRR RidsAcrsAcnw_MailCTR Resource RidsNrrPMMonticello Resource J. Borromeo, NRR RidsNrrDeEicb Resouirce RidsRgn3MailCenter Resource M. Chernoff, NRR RidsNrrDorllpl3-1 Resource RidsOpaMailCenter Resource M. Panicker, NRR RidsNrrDssSnpb Resource M. Waters, EDO RIV R. Stattel, NRR RidsNrrDssSrxb Resource T. Wertz, NRR RidsNrrDssStsb Resource A. Sallman, NRR ADAMS Accession Numbers: Package: ML15195A450; Meeting Notice: ML15176A336; Meeting Summary: ML15195A447; Licensee Meeting Handouts: ML15196A019 Response to Public Comment: ML15196A011
- concurrence prov1"d ed via
. e-ma1*1 OFFICE DORL/LPL3-1/PM DORL/LPL3-1/LA DSS/SRXB/BC DSS/SNPB/BC NAME TBeltz (JBurkhardt for) KGoldstein CJackson JDean DATE 7/23/2015 7/22/2015 7/28/2015 7/28/2015 OFFICE DSS/STSB/BC DE/EICB/BC DORL/LPL3-1 /BC DORL/LPL3-1/PM NAME RElliott * (ORahn for) JThorp DPelton TBeltz DATE 7/24/2015 7/31/2015 8/04/2015 8/05/2015