Entergy Nuclear Northeast Entergy Nucear Operatic-s. Ic.
i- Entergy indian Pcint Energy Ccntcr 295 Broadway. Suite 1 P.O. Box 2-9 Buchanan. NY 10511-0249 February 19, 2002 Re: Indian Point Unit No. 1 and No. 2 Docket No.50-003 and No. 50-247 NL-02-020 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Station O-Pl-17 Washington, DC 20555-0001
SUBJECT:
Revision to Emergency Plan Procedures
Dear Sir:
In accordance with 10 CFR 50.54(q) and 10 CFR 50.4(b)(5), Entergy Nuclear Operations, Inc., submits herewith a controlled copy of changes to the Emergency Plan procedures for Indian Point Units Nos. 1 and 2. These changes do not reduce the effectiveness of the Emergency Plan and the Emergency Plan as a whole continues to meet the standard of 50.47(b) and the requirements of Appendix E to 10 CFR 50.
There are no commitments contained in this letter. Should you or your staff have any questions, please contact Mr. Frank Inzirillo, Manager, Emergency Planning, (914) 271-7418.
Sincerely, Fred Dacimo Vice President - Operations Indian Point 2 Enclosure cc: Next page A yq5
NL-02-020 Page 2 of 2 Enclosure as noted:
cc: Mr. Hubert J. Miller (enclosure - 2 copies)
Regional Administrator - Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1498 Mr. Patrick D. Milano, Senior Project Manager (without enclosure)
Project Directorate 1-1 Division of Licensing Project Management U.S. Nuclear Regulatory Commission Mail Stop 0-8-C-2 Washington, DC 20555 Senior Resident Inspector (without enclosure)
U.S. Nuclear Regulatory Commission Indian Point Unit 2 PO Box 38 Buchanan, NY 10511
TO: Emergency Planning Document Controlled Copy # 14 Holder/Location NRC Document ControlDesk (Washington)
Document Holder Organization FROM: Emergency Planning Document Custodian
SUBJECT:
Emergency Planning Document Update Please update your controlled copy of the documents listed below as specified with the copy(s) attached. It is requested that the update be completed within 3 days of the effective date shown on the document cover page.
Please sign this memo indicating that you have completed the update as specified and return to:
Entergy Nuclear Northeast Indian Point Energy Center Emergency Planning Department Buchanan Service Center Broadway & Bleakley Aves.
Buchanan, NY 10511 Attn: Document Custodian Document # Document Name New Rev.
- / Date Old Rev.
- 1Date Instructions Plan Title Page 01-02a 01-02 Replace Page 10/18/01 Plan Table of Contents (Blue Page)01-02a N/A Place 01-02a page in front Plan______ Section ____________________ _______ _______ of TOc page Plan ISection 5 01-02a 101-02 1Replace whole section 4- 4. 4- +
Update completed as specified:
Signature of Controlled Copy Holder Date
CONSOLIDATED EDISON COMPANY OF NEW YORK, INC.
DOCKET NOS. 50-3, 50-247 EMERGENCY PLAN FOR INDIAN POINT UNIT NOS. 1 AND 2 Revision 01-02a CONTROLLED COPY SNSC Review: Date: . d- a Approved By: // I. Date: f/a.
Effective Date:
Emergency Plan for Idian .. Table of Contents Point Unit Nos. & 2 The following minor changes have been made to Revision 01-02 of this document.
Revision 01-02a Pages 5-12, 5-13, 5-20, 5-21, 5-23, 5-24, 5-33, 5-34, 5-35 have been revised, revision bars mark changed wording. Entire section replaced with the new pages which are designated as Revision 01-02a Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies 5.0 ORGANIZATIONAL CONTROL OF EMERGENCIES Using the normal shift operating organization as a base, this section of the Plan describes the Emergency Response Organization that may be activated onsite and augmented with Entergy personnel and offsite forces when necessary.
Authorities and responsibilities of key individuals and groups are delineated. The communication links for notifying, alerting and mobilizing emergency personnel are identified.
5.1 NORMAL PLANT ORGANIZATION The normal watch organization for the Station (Figure 5-1) functions twenty four (24) hours per day, seven (7) days per week and consists of the following qualified individuals:
One (1) Shift Manager, who holds a Senior Reactor Operator's license and is in charge of operating personnel during his/her shift and is responsible for assuring that all operations are conducted in accordance with approved procedures and the limitations set forth in Unit Technical Specifications; One (1) Control Room Supervisor, who holds a Senior Reactor Operator's license and is responsible for safe operation of the unit within the requirements of the Technical Specifications.
Two (2) Control Room Operators, who both hold a Reactor Operator's license, are responsible for manipulating controls in the Control Room including taking the immediate operator action required as stipulated by written procedures necessary to maintain or bring the plant to a safe condition during abnormal and/or emergency conditions; One (1) Watch Engineer who performs two main functions in an advisory capacity to the Shift Manager;
- Accident Assessment
- Operational review from a safety perspective; Two (2) Nuclear Plant Operators who perform plant operations and monitoring under the direction of the Control Room 5-1 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies Supervisor. One Nuclear Plant Operator is assigned to the conventional, the other to the nuclear portion of the plant.
Two (2) additional Nuclear Plant Operators function as rovers; Two (2) Health Physics Technicians (one from Unit 3) and one (1) Chemistry Technician perform radiation monitoring; surveillance, decontamination, water chemistry or counting as necessary; One (1) Field Support Supervisor who reports to the Shift Manager and supervises (1) Nuclear Plant Operator normally assigned to Unit 1.
The watch organization is augmented during normal working hours Monday through Friday by the Indian Point Management and Operations Staff which is organized to lend expertise to the watch force. Figure 5-2, shows the normal station organization functional areas and reporting chains.
The Shift Manager and the Control Room Supervisor have the responsibility and authority to declare an emergency, initiate the appropriate immediate action in accordance with written procedures, mitigate the consequences of the emergency, activate the Onsite Emergency Organization and notify offsite support and government agencies.
5.2 ONSITE EMERGENCY RESPONSE ORGANIZATION The Onsite Emergency Response Organization is established to assure that a sufficient number of appropriately qualified personnel are available each day, 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> a day to deal with any situation. This organization consists of three (3) staffing levels.
During an event or emergency at Indian Point Unit 2, the first phase of the response is conducted by normal watch personnel onsite (Staffing level I).
Staffing level II requires activation of the minimum Onsite Emergency Response Organization which includes an augmented normal watch. The Onsite Emergency Response Organization is capable of performing those near-term activities necessary to (1) maintain and/or regain control of the plant and mitigate the consequences of the emergency, (2) conduct accident assessment and analysis to determine the full scope and 5-2 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies impact of the situation, and (3) establish and maintain communications with authorities responsible for implementing offsite emergency measures.
Staffing level III occurs at the declaration of a Site Area Emergency and gives the Emergency Director full access to the resources of the Company. The Emergency Operations Facility, Technical Support Center and Operational Support Center are fully staffed. The Corporate Response Center is activated at Corporate Headquarters.
Table 5-1 presents, in tabular form, the minimum staffing requirements of NUREG-0654 on-shift personnel and the additional personnel required within 60 minutes of declaring a Site Area Emergency. The Watch Force, identified as Staffing Level I and depicted in Figure 5-1 satisfies the NUREG-0654 requirements for on-shift personnel.
Personnel required to augment the Watch Force within 60 minutes of the declaration of an emergency, plus the Watch Force, are identified as Staffing Level II. These personnel are immediately available during normal working hours or are contacted by a page "beeper" system during non-working hours.
The pager system is backed up with an automated telephone notification system. The additional personnel that may be contacted to supplement the minimum staffing requirements depicted in Figure 5-1 are listed in the Emergency Telephone Directory.
Figure 5-3 presents an organizational chart of the Emergency Response Organization, showing the major onsite functional areas and the relationships to offsite groups. Until the arrival of the Emergency Director and the start of the staffing level III organization, overall control of the onsite emergency organization will be exercised by the Emergency Plant Manager.
Figure 5-4 shows the full Emergency Response Organization (staffing Level III). Table 5-2 provides descriptions of the roles and responsibilities for each of the positions identified in Figure 5-4.
5-3 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies 5.2.1 Direction and Coordination The Shift Manager (or the Control Room Supervisor in the event that the Shift Manager is unavailable) has the authority to declare an emergency and immediately takes charge of the emergency response effort. In the event of an Alert, Site Area or General Emergency, he/she activates the Onsite Emergency Response Organization and functions as the Emergency Director directing the emergency response until the arrival of management personnel who relieve him/her of the duties of Emergency Plant Manager and Emergency Director.
The Emergency Plant Manager takes charge of the overall emergency response, thus freeing the Shift Manager to direct his/her attention towards the mitigation of the accident using the emergency operating procedures.
Until the arrival of the Emergency Director, overall control of the Onsite Emergency Organization will be exercised by the Emergency Plant Manager.
The following positions have responsibilities for command and control of the Emergency Response Organization:
5.2.1.1 Emergency Director The Emergency Director is responsible for directing and coordinating the integrated emergency response effort of all Company activities during the emergency including those which originate from Corporate Headquarters. Personnel trained in accordance with this plan and qualified as Emergency Directors are designated in the Emergency Telephone Directory. The Emergency Director is stationed in the Emergency Operations Facility during Alert, Site Area and General Emergencies and is the interface between the onsite and offsite authorities. He/she has the responsibility and authority to provide protective action recommendations to the authorities responsible for implementing offsite emergency measures.
The Shift Manager (or Control Room Supervisor if the Shift Manager is not present) becomes the Emergency Director upon declaration of an emergency. The Emergency Plant Manager will assume the role of 5-4 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. & 2 Emergencies Emergency Director upon his/her arrival at the Central Control Room until a Emergency Director is ready to assume the position at the Emergency Operations Facility. Specific responsibilities of the Emergency Director include:
- Declare the emergency and upgrade/downgrade conditions as warranted and initiates recovery phase when appropriate, this responsibility can not be delegated;
- Review and approve initial notifications to the State and local authorities, this responsibility can not be delegated;
- Recommend protective actions to offsite authorities, this responsibility can not be delegated;
- Authorizing Entergy personnel outside the Protected Area Fence to exceed normal radiation exposure limits, this responsibility can not be delegated;
- Establish communications with the Technical Support Center and obtain information on the diagnosis and prognosis of the accident condition;
- Review all radiological, meteorological and operational data and update the offsite authorities and the Joint News Center;
- Receive designated responding representatives from offsite emergency agencies and assist in their information and communication needs;
- Arrange for and dispatch any special assistance or service requested (e.g., radiological measurement or protection equipment, onsite medical treatment);
- Coordinate offsite radiological evaluation with the State, Counties and U.S. Department of Energy.
- Relate all of these actions to the remainder of the emergency response organizations.
5-5 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies The Emergency Director is assisted in these activities by personnel in the Emergency Operations Facility and in the field. Although the Emergency Director may delegate most of these responsibilities, he/she may not delegate the responsibility for the decision to notify and recommend protective actions.
5.2.1.2 Emergency Plant Manager The Emergency Plant Manager directs and coordinates the operational aspects of the In-Plant Emergency Organization. He/she assures proper coordination and direction of the efforts of each element of the In-Plant Emergency Organization in returning the plant to and maintaining it in a safe and stable condition.
The Emergency Plant Manager is normally located in the Technical Support Center, he/she may go to the Central Control Room to receive briefings from the Shift Manager and review plant data. Specific responsibilities of the Emergency Plant Manager include:
- Initially relieving the Shift Manager of the Emergency Director responsibilities and continue to act as Emergency Director until an Emergency Director is ready to assume the position in the Emergency Operations Facility.
- Directing actions to mitigate the accident.
Directing the in-plant radiological monitoring.
- Authorizing Entergy personnel within the Protected Area to exceed normal radiation exposure limits, this responsibility can not be delegated;
- Authorizing the mobilization of search and rescue teams.
- Directing re-assembly within the protected area fence.
- Assuring that all emergency personnel within the protected area fence take adequate protective measures.
5-6 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies 5.2.1.3 Emergency Operations Facility Manager The Emergency Operations Facility Manager is located in the Emergency Operations Facility and reports to the Emergency Director. He/she directs and coordinates the activities of the Emergency Operations Facility. He/she assures proper staffing and operations of the Emergency Operations Facility to assist the Emergency Director in completion of his/her responsibilities. Specific responsibilities of the Emergency Operations Facility Manager include:
- Direct and coordinate the activities of the Emergency Operations Facility;
- Assist the Emergency Director with interactions with offsite authorities.
5.2.1.4 Offsite Radiological Assessment Director The Offsite Radiological Assessment Director reports directly to the Emergency Operations Facility Manager.
Specific Responsibilities of the Offsite Radiological Assessment Director include:
- Directing and coordinating the activities of the offsite and onsite (outside the protected area fence) radiological monitoring teams;
- Interpreting radiological and meteorological data and updating the Emergency Director with the result in the terms of both real-time measurements and projected radiological exposures;
- Providing radiological evaluation and protection at the Emergency Operations Facility;
- Having estimates of offsite population dose performed;
- Initiating post-accident environmental surveys.
5-7 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies 5.2.1.5 Technical Support Center Manager The Technical Support Center Manager is responsible for directing coordination of the Technical Support Center as the central facility for the accumulation and re-transmittal of plant parameters. The Technical Support Center Manager is stationed in the Technical Support Center and reports to the Emergency Plant Manager.
Specific responsibilities of the Technical Support Center Manager and Staff include:
- Analyzing and developing plans and procedures in direct support of Plant Operations personnel;
- Analyzing and resolving core physics, thermodynamic, hydraulic, mechanical, electrical and instrument problems.
- Designing and coordinating short term modification to plant systems.
- Keeping the Emergency Plant Manager appraised of plant conditions.
- Interfacing with NRC personnel in the Technical Support Center.
5.2.1.6 Operations Support Center Manager The Operations Support Center Manager is responsible for directing coordination of the Operations Support Center as the central facility for the planning and dispatch of operations and repair teams into the plant. The Operations Support Center Manager is stationed in the Technical Support Center, next to the Operations Support Center and reports to the Emergency Plant Manager.
Specific responsibilities of the Operations Support Center Manager and Staff include:
5-8 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies
- Maintaining continuous accountability of all personnel within the Protected Area when it is called for.
- Planning and/or coordination of field activities, such as search and rescue, investigations, equipment operation, surveys or repairs
- Developing relief staffing rosters to ensure 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> manning of Emergency Response Facilities.
5.2.2 Plant Staff Emergency Assignments In addition to the direction and coordination of the emergency response effort just discussed, other major functional areas of responsibility are identified as necessary to deal with emergency situations.
Assignments made for these functional areas are discussed below. The interfaces between these functional areas is shown in Figure 5-4.
5.2.2.1 Plant Operations and Assessment of Operational Aspects While overall direction of in-plant activities is the responsibility of the Emergency Plant Manager, responsibility for plant systems operations remains with the Control Room Operators and the Nuclear Plant Operators under the direction of the Shift Manager and Control Room Supervisor.
5.2.2.2 Notification/Communication The Control Room communication links with offsite authorities are manned each day 24-hours a day by Control Room personnel. The initial notification of offsite authorities and emergency response organization personnel is initiated by the Shift Manager and the Control Room Communicator. Communications with offsite authorities are maintained from the Control Room until the Emergency Director takes over the responsibility at the Emergency Operations Facility. A "Communicator" is designated at the Emergency Operations Facility to establish/maintain communication links.
5-9 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies 5.2.2.3 In-Plant Radiological Accident Assessment In-plant radiological monitoring and chemical/
radiochemical analysis is provided by the Watch Health Physics Technician and Chemistry Technician, respectively, under the direction of the Shift Manager and by other responding personnel under the direction of the Emergency Plant Manager.
5.2.2.4 Offsite Radiological Accident Assessment The expertise for evaluating the radiological consequence of the accident is provided by the Dose Assessment Health Physicist and the Survey Team Health Physicist who function directly under authority of the Offsite Radiological Assessment Director. These individuals assure that sufficient monitoring activities are instituted, evaluate and assess the results, and apprise the Offsite Radiological Assessment Director of all activities, results and recommendations. Until the EOF is activated, the Shift Manager shall be responsible for the performance of offsite radiological accident assessments. Onsite, out-of-plant radiological monitoring will be provided for by responding Radiation Protection Personnel.
Offsite monitoring is performed by Radiation Protection and other qualified personnel from Indian Point.
5.2.2.5 Plant System Engineering The Watch Engineer supplies plant technical assistance to the Shift Manager during the initial stages of an emergency. Personnel who assemble in the Technical Support Center include selected members of the plant staff who are knowledgeable in one or more specific disciplines or functional areas at Indian Point. These individuals perform operational accident assessment activities in support of the watch personnel handling the in-plant accident conditions.
5.2.2.6 Repair and Corrective Actions The Shift Manager and Nuclear Plant Operators perform emergency repairs if necessary, within the first 60 5-10 Revision 01-02a
I-mergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies minutes. Other Station maintenance personnel are not immediately available.
Maintenance mechanics and operations personnel (NPO) who respond to the Operations Support Center perform repair and corrective actions directed by the Operations Support Center Manager.
5.2.2.7 Protective Actions (In-Plant)
The Watch Health Physics Technician is normally responsible for radiation protection in-plant. The Field Support Supervisor and the Unit No. 2 Watch Health Physics Technician are immediately available for radiation protection under the direction of the Shift Manager during the first 60 minutes. Later, Health Physics personnel under the direction of the Operations Support Center Manager are responsible for radiation protection.
5.2.2.8 Firefighting Fire fighting is the responsibility of the Fire Brigade as defined in the Indian Point Station Fire Protection Program Plan. The Fire Brigade consists of at least five members who are trained in fire fighting techniques and are on duty 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> a day. A local fire department may be called if necessary.
5.2.2.9 Rescue Operations and First Aid Search and rescue jurisdiction during an emergency is divided between the in-plant area (inside the protected area fence), which is handled by the Shift Manager or Emergency Plant Manager, and the rest of the onsite area which is handled by the Emergency Director. Search and rescue operations would initially be directed during the first 60 minutes by the Shift Manager using available personnel onsite.
There is at least one individual on duty 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> a day (exclusive of the Shift Manager) who is trained in first-aid techniques. Additional medical support can be called as necessary.
5-11 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies 5.2.2.10 Site Access Control and Accountability Plant security and site access control are the responsibility of the Security, Supervisor and the Security Force, with backup assistance available from the Buchanan Police Department and other police departments in Westchester County as the situation demands, in accordance with a County Mutual Assistance Plan and the New York State police.
Initial personnel accountability during an Alert, Site Area Emergency or a General Emergency is the responsibility of the Shift Manager and Shift Security Supervisor. Procedures in the Emergency Plan Implementing Procedures are used to account for all personnel within the Protected Area. If necessary, Security Personnel will be dispatched to warn employees, visitors, contractors and construction personnel who may be within the exclusion area but outside the Protected Area.
Continuous accountability will be maintained during events classified as a Site Area or General Emergency.
The Emergency Plant Manager may suspend accountability requirements at the Alert level.
5.2.3 Information Dissemination To assure that only factual and consistent information is released statements concerning the emergency are the responsibility of the Indian Point Communications. A Indian Point Communications Representative is on call 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> a day and is responsible for interfacing with the news media for release of any public statements concerning any declared emergency. For events classified at an Alert or higher, a Joint News Center Director responds to the pre-designated Joint News Center.
The Joint News Center Director will be responsible for providing accurate and timely information to the public through the news media and coordinating with Federal, State and local public information officials to assure timely exchange and release of information. Both the Indian Point Communications Representative and the Joint News Center Director have access to all necessary 5-12 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies information, either directly available to them or available through the Emergency Plant Manager/Emergency Director. An Information Liaison at the Emergency Operation Facility reports to the plant with the initial augmentation of the watch force to facilitate information flow between the plant personnel and the Indian Point Communications Representative and/or the Joint News Center Director.
5.3 AUGMENTATION OF EMERGENCY ORGANIZATION This section describes the offsite support available from three (3) sources: Corporate Headquarters, local services, and private sector organizations. The need for this augmentation will be evaluated by the Emergency Plant Manager, Technical Support Center Manager and the Emergency Director. The names and phone numbers of the offsite support contacts are listed in the Emergency Telephone Directory which is maintained in the Unit 2 Control Room, Technical Support Center and in the Emergency Operations Facility.
Figure 5-3 illustrates the interface between the Onsite Emergency Organization and the offsite support groups.
5.3.1 Corporate Support Company personnel augment the onsite staff in the performance of certain functions required to cope with an emergency. The corporate support is integrated into the Emergency Response Organization at Staffing Level III (refer to figure 5-4). With the activation of Staffing Level III, Entergy is capable of continuous (24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />) operations for a protracted period. The Emergency Director will assure the continuity of resources(technical, administrative and logistics) to support the emergency response.
5.3.2 Local Services Support The availability of local services support to assist the emergency forces has been ascertained and agreement letters from each organization in this section have been solicited. These letters are contained in Section 10, Appendix A.
5-13 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies 5.3.2.1 Ambulance Service Twenty-four (24) hour ambulance service is provided by the Verplanck Fire Department Ambulance with mutual aid backup from other ambulance services such as the Cortlandt Volunteer Ambulance Corps. and the Peekskill Volunteer Ambulance Corps. The Emergency Plan Implementing Procedures contain procedures which cover the call for assistance and the handling of the ambulance service personnel. Radio communications exists between the ambulance and local hospitals and the site can communicate with the ambulance through this link.
5.3.2.2 Medical Local physicians, under contract to the Entergy Medical Department, are available. The Emergency Plan Implementing Procedures cover the request for medical assistance and the handling of patients. In the event that a patient should receive a massive radiation exposure, an expert medical consultant on the management of radiation injuries would be available. A written agreement is contained in Section 10, Appendix A.
5.3.2.3 Hospital The Hudson Valley Hospital Center at Peekskill/Cortlandt has agreed to accept patients from the Indian Point Site who have been injured, contaminated or irradiated. This is a modern hospital with facilities such as an emergency room, a laboratory, a radiology department and a nuclear medicine department.
The Phelps Memorial Hospital Center, Tarrytown, New York has agreed to serve as the backup hospital. A written agreement is contained in Section 10, Appendix A.
5-14 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. & 2 l Emergencies 5.3.2.4 Police When notified that assistance is required, the Village of Buchanan Police Department will respond immediately.
Timely reinforcement can be provided by adjacent police departments to include, eventually, all police departments in Westchester County as the situation demands in accordance with a County Mutual Assistance Plan, and the New York State Police. The handling of security matters for the Indian Point site is covered in the Security Plan.
5.3.4 Private Sector Organizations 5.3.4.1 Laboratory Services The availability of laboratory/analytical services has been ascertained and an agreement letter is contained in Section 10, Appendix A.
5.3.4.2 Additional Technical Assistance If the need for additional technical assistance is identified, this may be obtained by the Technical Support Center Manager and the Emergency Director.
Assistance of this type would include that from the NSSS Supplier (Westinghouse), architect engineer and consultants. A copy of the letter of agreement with Westinghouse is contained in Section 10, Appendix A.
The Institute for Nuclear Power Operations (INPO) may be called upon, by the Emergency Director, to act as the agent to arrange for and coordinate emergency support using the information in the INPO Emergency Resources Manual. The manual contains information on;
- Equipment that is available from other utilities
- Equipment that can be supplied by vendors
- Service Companies and available personnel
- A/E & NSSS Contacts
- Technical experts and their specialties
- Telephone directory for other utilities 5-15 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies 5.4 COORDINATION WITH PARTICIPATING GOVERNMENT AGENCIES
-. In the event of an emergency, as defined in Section 4.1, various Federal, State, and County organizations must be notified. This section identifies the principal State agency and other government agencies having planning and/or action responsibilities for emergencies, in the Westchester, Orange, Putnam and Rockland County areas of New York State.
5.4.1 New York State The agency responsible for emergency planning is the State Emergency Management Office. The Chairman of the Disaster Preparedness Commission will assume the direction and coordination of the State response activities. The specific tasks and responsibilities assigned to various departments and agencies of the State are delineated in New York State's Radiological Emergency Preparedness Plan. Notification to the State of emergency conditions would be as indicated in Section 6.1.
5.4.2 U.S. Department of Energy The U.S. Department of Energy operates a Radiological Assistance Plan from its regional office at Brookhaven, Long Island. The Radiological Assistance Plan, which specializes in radiation safety and medicine, will provide assistance to the Nuclear Facility Operator, the State or the county request. This assistance, which includes monitoring of the environment surrounding the site, is available twenty-four (24) hours a day by calling the contact phone number listed in the Emergency Telephone Directory. The expected l time of arrival is approximately 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br />. The Emergency Director is authorized to request this assistance in the event it is necessary. Westchester County Airport, located approximately 30 minutes by automobile from the site, can supply facilities for air transportation. An agreement letter which addresses this assistance can be found in Section 10, Appendix A.
5.4.3 U.S. Coast Guard During a radiation incident which could have offsite radiological consequences, the U.S. Coast Guard will 5-16 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies assist by maintaining traffic control on the Hudson River. Coast Guard assistance is requested by and coordinated through New York State, the appropriate county, or FEMA.
5.4.4 County Offices of Disaster and Emergency Services/Civil Defense The four(4) counties which are involved in emergency response activities at the Indian Point Site include Westchester, Rockland, Orange and Putnam. Westchester, the County in which the Indian Point is located; Rockland County on west side of the Hudson River across from Indian Point; and Orange and Putnam Counties the closest boundaries of which are approximately four (4) miles from Indian Point. Each county has an Office of Disaster and Emergency Services or Civil Defense. The Director of each of these offices, or their designee, will act as the County Emergency Operations Director in the County Emergency Operations Center and direct and coordinate the County's response, under the authority of the Chief Executive of the County, for natural and man-made disasters. Notifications to the Counties of an Unusual Event, Alert, Site Area or General Emergency at Indian Point would be as described in Section 6.1.
5.4.5 New York State Emergency Management Office, Southern District During an emergency, New York State can utilize the facilities at the Emergency Management Office, Southern District which has an 8,700 square foot underground EOC equipped with statewide communications capability.
5-17 Revision 01-02a
Emergency Plan for Indian Section 5.0 Organization Control of Point Unit Nos. 1 & 2 Emergencies Figure 5-1 Normal Watch Organization N...
- One Health Physics Technician is onshift at Indian Point 3 and is available to respond to an emergency at Indian Point 2.
5-18 Revision 01-02al
(
Emergency Plan for Indian Point Unit Nos. 1 & 2 -I Section 5.0 Organization Control of Emergencies Figure 5-2 Normal Station Organization Functional Areas Senior VP and Chief Operating Officer
- U I
I Director Human Senior VP and Site Director Emergency VP Engineering Resources Nuclear Executive Planning I I I I
( Section Manager P2 Human Resources Manager P2 Employee Concerns I Vice President Operations IP1 & P2 Section Manager P2 Emergency Planning Director Engineering IP2 a I T
-I- . . I -- I Department Manager General Manger P2 Plant Manager 1P2 General Manager P2 Nuclear Power Manager P2 IP2 Nuclear Training Business Services Nuclear Quality Generation Communications Assurance Manager Corrective Action 5-19 Revision 01-02a
1.
I I I Emergency Plan for Indian Point Unit Nos. 1 & 2 Section 5.0 Organization Control of Emergencies Figure 5-3 Onsite-Offsite Organization Interfaces Note 1: Overall control of the Entergy Unit 2 ERO Offsile emergency response Is the responsibility Response Federal Agencies of the Emergency Director Organizations NRC Note 2: After the initial notifications from Emergency Note: 2 FEMA the CCR the EOF Is the central location Director Etc.
of offsite communications, with the Note 1 exception of technical data which goes In EOF and out of the TSC I NYS Emergency I I I Operations Center -
Emergency Plant Joint News Center Manager Director 4 Co. Emergency L TSC / CCRj JNC Operations Centers l
Media Relations Public Information Rumor Control Offsito Radiological Assessment Offisle Communications Corporate Support I
Public Inquiry Overall Entergy Contractors Coordination Consultants ETC.
I OSC Manager I
TSC INPO Security Manager Supervisor OSC / TSC Immediate Response TSC CGH Organizations I
Fire Site Protective Police Actions & Engineering Site Ambulance Corrective Actions Support Security Hospital 5-20 Revision 01-02a
! ( (
IEmergency Plan for Indian Point Unit Nos. 1 & 2 Section 5.0 Organization Control of Emergencies Figure 5-4 (Sheet 1 of 4)
Indian Point Unit 2 Emergency Response Organization Overall coordination of Entergy Emergency C ompany emergency response. Director Spo kesperson lI Emergency Emergency Joint News Plant Operations Facility Center Manager Manager Director I
l EI I See Onsite See Public See Offsite Organization Organization Information Sheet 2 Sheet 3 Organization Sheet 4
- Coordination of Entergy onsite
- Coordination of Entergy offsite
- Overall coordination of Entergy response response Public Information Response
- Plant Operations
- Notifications and
- Coordinate public information
- Engineering Assessment communications with State and with the State and Local
- Corrective Actions Local authorities. Response Organizations
- Onsite Radiological
- Offsite Radiological
- Interface with the Media Assessment Assessment
- Rumor Control
- Safety of onsite Entergy
- Safety of ofisite Entergy
- Public Inquiry Emergency Responders Emergency Responders 5-21 Revision 01-02a
( (
Emergency Plan for Indian Point Unit Nos. 1 & 2 Section 5.0 Organization Control of Emergencies Figure 5-4 (Sheet 2 of 4)
Indian Point Unit 2 Emergency Response Organization I&C Maintenance RP/Chem Operations Coordinator Coordinator Coordinator Coordinator I&C Maintenance RP/Chem OSC Ops Technicians Technicians Technicians Staff 5-22 Revision 01-02a
( t A.
Emergency Plan for Indian Point Unit Nos. 1 & 2 A lSection 5.0 Organization Control of Emergencies Figure 5-4 (Sheet 3 of 4)
Indian Point Unit 2 Emergency Response Organization Technical I I Emergency Director 9
] Admin &
Advisor Logistics Mgr
- A I __
Manlager j OF~~~~~O
_________________ __ Informaton
----- ----- Liaison 9
I I
Offsite Radiological EOF EOF EOF Assessment Director Communicator Clerical Offisite Number 2 Staff Liaison l
I 1
i1.
State & County Dose EOF Technical Assessment Communicator Liaison Health Physicist Number 1
'l Z I I MIDAS Field Monitoring Operator Teams 5-23 Revision 01-02a
( I
(
Emergency Plan for Indian Point Unit Nos. I & 2 Section 5.0 Organization Control of Emergencies Figure 5-4 (Sheet 4 of 4)
Indian Point Unit 2 Emergency Response Organization Emergency Director Company LIfaIIZ EOF_____ Spokesperson l_____
Inormation .
DiJNC rector 5-24 Revision 01-02a
/
Emergency Plan for Indian Point Unit Nos. 1 & 2 Section 5.0 Organization Control of Emergencies Table 5-1 (3 Sheets)
On-shift Staffing and Augmentation Available Major Position Title On Within Functional Area Location Major Tasks or Expertise shift 60 Minutes Plant Operations & CCR Shift Manager 1 __
Assessment of Control Room 1 __
Operational Supervisor Aspects Reactor Oper. 2 __
Nuclear Plant Oper. 2 __
Emergency CCR. overall direction & Shift Manager or 1* --
Direction & control Control Room Control (Emergency Supervisor Director***)
Notification/ CCR Notify licensee, State, Communicator l**** 2 Communication TSC local & Federal EOF Personnel & maintain communication Radiological CCR/EOF Emergency Operations Emergency Plant 1 Accident Facility (EOF) Director Manager/ Emergency Assessment Director EOF Offsite Dose Assessment ORAD 1 Offsite Surveys Offsite Monitors 4 Onsite Surveys (out-of- Onsite Monitors 2 plant)
In-plant Surveys Health Physics 1 2 Chemistry/Radio- Technician chemistry Chemistry 1 1
_ _ _ _ _ _ _ ___Technician 25 Revision 01-02a
f
(
Emergency Plan for Indian Point Unit Nos. 1 & 2 Section 5.0 Organization Control of Emergencies Available Major Position Title On Within Functional Area Location Major Tasks or Expertise Shift 60 Minutes Plant System CCR/TSC Technical Support, Watch Engineer 1 Engineering and operational accident Core/Thermal 1 support of assessment Hydraulics Operational Engineer Assessment Electrical 1 Engineer Mechanical 1 Engineer Repair and OSC Repair and Corrective Mechanical 1** 2.
Corrective Actions Actions Maintenance Technician Electrical 2 Maintenance Technician Instrument & 1 Control Technician)
Protective Actions Radiation Protection: Health Physics 2** 4 (In-Plant) a.Access Control Technician
- b. HP Coverage for repair, corrective actions, search and rescue, first-aid &
firefighting monitoring
- c. Personnel monitoring
- d. Dosimetry 5-26 Revision 01-02a
I Emergency Plan for Indian Point Unit Nos. 1 & 2 Section 5.0 Organization Control of Emergencies Available Major Position Title On Within Functional Area Location Major Tasks or Expertise Shift 60 Minutes Fire fighting Fire Local Brigade Support per T.S.
Rescue Operations 2** Local and First-Aid . Support Site Access Control Security, All per Personnel Security Plan Personnel OSC Manager / Team Accountability Coordinator TOTAL TOTAL 10 26 May be provided by shift personnel assigned other functions overall direction of emergency response to be assumed by the on-call Emergency Director.
Direct operation of plant systems remains with the Shift Manager Performed by Facility Support NPO or Security 5-27 Revision 01-02a
( I Emergency Plan for Indian Point Unit Nos. 1 & 2 l Section 5.0 Organization Control of Emergencies Table 5-2 (7 Sheets)
Indian Point Unit 2 Emergency Response Organization Roles & Responsibilities
_ ~~Figure 5-4 Emergency Title . Roles/Responsibilities Sheet No.
Emergency Director 1 Refer to Section 5.2.1.1 Company 1 Updates media on plant conditions during briefings; approves news Spokesperson releases.
Emergency Plant 1 Refer to Section 5.2.1.2 Manager EOF Manager 1 Refer to Section 5.2.1.3 Responsible for overall direction of JNC; supervises information flow Joint News Center 1 in JNC; coordinates briefings with State, and counties and Company Director Spokesperson.
TSC Manager 2 Refer to Section 5.2.1.5 Technical Directs the activities of the technical assessment team; assists the Assessment 2 TSC Manager in planning and performing engineering assessments of Coordinator plant conditions and actions to be taken to mitigate plant damage.
Core Physics Monitors and assesses plant conditions for any indications of core Core Physics 2 damage; assists operations personnel in tracking core reactivity; Engineer assesses status of fission product barrier integrity.
5-28 Revision 01-02a
I (
(
(Emergency Plan for Indian Point Unit Nos. 1 & 2 Section 5.0 Organization Control of Emergencies Figure 5-4 Emergency Title Roles/Responsibilities Sheet No.
Monitors fission product barrier integrity and plant status, provide!
recommendations for emergency classification changes based on EALs; Operations Advisor 2 clarifies plant parameter information for the technical assessment team; works with other members of the TSC staff to provide support to the CCR to mitigate the effects of the event.
Monitors plant radiological conditions and any release or potential release of radioactive materials; provides radiological status update Radiological to TSC personnel; assists the Radiation Protection Coordinator in the Advisor 2 development of emergency radiation work permits; assesses plant' radiological parameters and informs other staff of the significance; provides input regarding decisions on emergency exposure authorizatio and issuance of KI.
Assists in clarifying IC/electrical information to members of the I&C/Electrical 2 technical assessment team; provides support to the CCR to mitigate th Engineer effects of the event; assists OSC Maintenance and I&C Coordinators in preparing repair teams for dispatch into the plant.
Assists in clarifying mechanical information to members of the mechanical Engineer 2 technical assessment team; provides support to the CCR to mitigate th, Mechanical Engineer 2 effects of the event; assists OSC Maintenance Coordinator in preparin' repair teams for dispatch into the plant.
TSC Data Activates computerized information systems in the TSC/OSC Complex; Coordinator 2 ensures necessary drawings and procedures are available; assists the TSC staff in obtaining plant data from various sources.
TSC Clerical 2 Provides clerical support to the TSC staff 5-29 Revision 01-02a
(
t Emergency Plan for Indian Point Unit Nos. 1 & 2 Section 5.0 Organization Control of Emergencies Figure 5-4 Emergency Title Roles/Responsibilities Sheet No.
Establishes an open line of communications between the TSC and the C(
TSC Communicator 2 and EOF; monitors communications from the CCR keeping aware of CCR personnel actions and procedures being implemented.
Establishes an open line of communications between the CCR and the T!
CCR Communicator 2 and EOF; monitors communications from the TSC keeping aware of TSC personnel actions and procedures being implemented.
Document Controller 2 Provides document control support for the TSC/OSC Complex.
Data Logger 2 Updates plant data for display in the TSC/OSC Complex.
Shift Manager 2 Refer to Section 5.2.1 Shift Operating 2 Refer to Section 5.2.2.1 Staff OSC Manager 2 Refer to Section 5.2.1.6 Radiation Coordinates radiological controls within the Protected Area during Protection 2 Coordinator emergencies.
Directs I&C operations during emergency, including planning jobs and I&C Coordinator 2 preparing repair teams for dispatch.
Maintenance Directs Maintenance (mechanical and electrical) operations during Coordinator 2 emergency, including planning jobs and preparing repair teams for dispatch .
5-30 Revision 01-02a
(
i
(
Emergency Plan for Indian Point Unit Nos. 1 & 2 Section 5.0 Organization Control of Emergencies Figure 5-4_
Emergency Title Roles/Responsibilities Sheet No.
Operations 2 Directs NPO operations during emergency and coordinates these Coordinator activities with the CCR.
Team Coordinator 2 Tracks team activities outside the OSC Accountability 2 Coordinates initial and ongoing accountability, arranges for second Clerk shift ERO, assist Team Coordinator in tracking teams.
Provide support for Health Physics, Chemistry, I&C, Electrical and Technicians 2 Mechanical operations in the plant during emergencies.
Security Supervisor 2 Refer to Section 5.2.2.10 Shift Security 2 Per Security Plan Staff obtains and monitors plant data and advises the Emergency Director Emergency Director regarding plant condition changes, observable trends in plant data, Technical Advisor 3 major operator actions being undertaken and any condition which may effect emergency classification; maintains plant status chronology, assists ED in interpreting data, assists in the conduct of briefings.
Administrative & 3 Provides interface with corporate organization for logistical support Logistics Manager Facilitates the timely and accurate flow of information from the EOF EOF Information 3 to the JNC; provides interface between the P2 Emergency Response Liaison organization and Media Relations; obtains clearance of news releases from Emergency director.
5-3 1 Revision 01-02a
!' ( (
Emergency Plan for Indian Point Unit Nos. 1 & 2 Section 5.0 Organization Control of Emergencies Figure 5-4 Emergency Title Roles/Responsibilities Sheet No.
Offsite Radiological 3 Refer to Section 5.2.1.4 Assessment Director Evaluates plant radiological data; conducts dose projections; assists Dose Assessment HP 3 the ORAD in directing onsite and offsite field monitoring teams; evaluates offsite survey data.
Obtains and maintains status of meteorological information; obtains MIDAS Operator 3 offsite radiological data from fixed radiation monitoring systeis; performs dose assessments as directed.
ouco#3 Transmits directions to offsite monitoring teams; receives and record EOF Communicator #1 onsite and offsite monitoring team data.
Field Monitoring 3 Perform onsite and offsite radiological monitoring; report monitoring Teams results to the EOF.
ouco 3 Performs required notifications to offsite authorities including the EOF Communicator #2 NYS Radiological Emergency Data Form Parts I and II.
Coordinated Information flow to and from liaisons located at the Stats EOF Offsite Liaison 3 and County EOCs. Provides contact for offsite representatives responding to the Emergency Operations Facility EOF)
State & County Provides clarification regarding plant information and notifications Technical EOC 3 received by the State & County EOC.
Liaison EOF Clerical Staff 3 Provides clerical support to the EOF staff 5-32 Revision 01-02a
I
(
Emergency Plan for Indian Point Unit Nos. 1 2 Section 5.0 Organization Control of Emergencies Figure 5-4 Emergency Title Roles/Responsibilities Sheet No.
Monitors information from the EOF/CCR to the JNC; advises utility JNC Technical 4 workroom personnel and Company Spokesperson on plant conditions and Advisor technical matters.
ietr4 Supervises and directs those operations of the JNC that involve the JNC Director flow of information from the plant to the News Media and Public Interfaces with the media present at the JNC; identify and arrange Media Room Liaison 4 for media needs and support audio-visual staff as needed and prepare media kits for the media.
Presides over the Media briefings; responds to Media Room manager 4 logistical/administrative questions of reporters; announces upcoming briefings; supervises the Media Room Liaisons and the A/V Coordinator and Staff and provides administrative support.
Supplies technical information on plant operations between briefings; Technical Briefer 4 follows Company Spokesperson's statements for technical accuracy.
Establishes and maintains folders to hold pertinent documents and JNC Documenter 4 maintains a log of JNC activities.
Interfaces with State and county Public Information Officers at the JNC;ensures that State and county PIOs receive notification of Agency Liaison 4 changing classifications, events, makes courtesy calls to PIOs that may not be at the JNC..
Audio visual 1 Sets up and manages recording of news broadcasts; directs videotaping Coordinator 4 of all news briefings and provides needed graphics for media Coordinator________
.jpresentations..
5-33 Revision 01-02a
I (
Emergency Plan for Indian Point Unit Nos. 1 & 2 Section 5.0 Organization Control of Emergencies I
Figure 5-4 Emergency Title Roles/Responsibilities Sheet No.
Monitors radio and television broadcasts in accordance with specifies Media Monitors 4 procedures.
JNC Writer 4 Drafts news releases and briefing notes.
Radiological Clarifies radiological information for utility workroom personnel and Advisor Company Spokesperson.
Media Referral 4 Distributes news releases to media organizations unable to come to t JNC.
Public Inquiry 4 Fulfills the rumor control and public inquiry function as defined in Coordinator specified procedures.
Radiological Health 4 Supplies information on radiation exposure and its potential health Expert effects to media.
Opens the JNC; oversees setup and activation of the JNC; oversees Administrative 4 registration activities for personnel responding to the JNC,as well a Manager security and the overall facility operations.
JNC Security 4 Provides security for the JNC utility, State and county work areas to ensure only authorized personnel enter those areas.
Administrative Provide registration personnel and clerical registration personnel Support Staff registration personnel clerical support as required.
Monitors IT equipment throughout the JNC ensuring proper working orde IT Representative 4 as well as troubleshoot and repair computer related difficulties.
IP Government Places initial notifications to pre-defined individuals regarding the Liaison 4 event underway and the pending release of information to the media an Representative public.
5-34 Revision 01-02a
(
Emergency Plan for Indian Point Unit Non. 1 & 2 Section 5.0 Organization Control of Emergencies Figure 5-4_
Emergency Title Roles/Responsibilities Sheet No.
Public Inquiry 4 Provide incoming callers (the public) with clarification of Staff information that may conflict with official announcements.
5-35 Revision 01-02a
TO: Emergency Planning Document Controlled Cope # 14 HolderALocation NRC Document ControlDesk (Washineton)
Document Holder Organization FROM: Emergency Planning Document Custodian
SUBJECT:
Emergency Planning Document Update Please update your controlled copy of the documents listed below as specified with the copy(s) attached. It is requested that the update be completed within 3 days of the effective date shown on the document cover page.
Please sign this memo indicating that you have completed the update as specified and return to:
Entergy Nuclear Northeast Entergy Nuclear Operations Inc.
Indian Point Nuclear Energy Center 295 Broadway, Suite 2 P.O. Box 249 Buchanan, NY 10511 Attn: Emergency Planning Department TOC Emergency Plan Implementing Procedures Table of Contents 1/23/02 12/2 10/17/01 1/70 Replace elc entire document niedcmn IP-1010 Central Control Room 2 Re 1/23/02 5/251/01 Replace entire document IP-l01 I Joint News Center 6 1/23/02 5 9/13/01 R Rplace entire document I + + +
Update completed as specified:
Signature of Controlled Copy Holder Date
Emergency Plan Implementing Procedures Table of Contents Procedfur' Rev. Effective.
IP-1 001 Mobilization of Onsite Emergency Organization 13 5/25/01 IP-1 002 Emergency Notification and Communication 25 9/6/01 IP-1003 Planned Discharge of Containment Atmosphere During Accident 7 4/16/01 Conditions IP-1 004 Post Accident Offsite Environmental Surveys, Sampling and Counting 5 911/99 IP-1007 Dose Assessment 11 3/26/01 IP-1008 Personnel Radiological Check and Decontamination 6 9/1/99 IP-1 009 Radiological Check and Decontamination of Vehicles 7 9/1/99 IP-1010 Central Control Room 3 1/23/02 IP-1011 Joint News Center 6 1/23/02 IP-1012 Onsite Medical Emergency 10 5/25/01 IP-1013 Protective Action Recommendations 8 11/1/99 IP-1014 Radiological Check of Equipment Before It Leaves the Site 6 9/1/99 IP-1015 Radiological Surveys Outside the Protected Area (Title Change) 9 3/26/01 IP-1016 Obtaining Meteorological Data 12 9/1/99 IP-1019 Coordination of Corporate Response 10 9/6/01 IP-1 020 Airborne Activity Determination 8 01/12/01 IP-1 021 Manual Update, Readout and Printout of Proteus Plant Parameter 5 9/1/99 Data IP-1 022 Obtaining Meteorological, Radiological and Dose Assessment Data 5 9/1/99 from MIDAS IP-1023 Operations Support Center (OSC) 16 10/17/01 IP-1024 Emergency Classification 8 01/12/01 IP-1025 Cancelled 10/17/01 IP-1 026 Emergency Data Acquisition 0 01/12/01 IP-1 027 Personnel Accountability and Evacuation 14 10/17/01 IP-1 030 Emergency Operations Facility (EOF) ! 5 9/6/01 Page of 2 As of 1/23/02
Emergency Plan Implementing Procedures Table of Contents Procedure
Rt§F;~~~ e - ;;! 7~We-z %4V -F-eerenceus Effective Date: 2-3lo2.. IP2 IP-101 1 (JNC) R6.doc AND IP3 JNC Operations Manual-Page 1 of 91 IP2 IP-1 011, Joint News Center, Rev. 6 1P3 JNC Operations Manual Table of Contents Section Pa.e
1.0 INTRODUCTION
................................................ 4 2.0 PURPOSE ................................................ 4 3.0 DISCUSSION/OPERATIONS OVERVIEW ................................................ 5 4.0 PRECAUTIONS AND LIMITATIONS ................................................ 7 5.0 EQUIPMENT AND MATERIALS ............................................... 8 6.0 INSTRUCTIONS ................................................ 8 6.1 Notification to IP Communications, other Entergy and Joint News Center Staff ............. 8 6.2 Initial Actions ........................................................... 8 6.3 Emergency Communications Activities After JNC Activation ...................... .................. 11 6.4 JNC Staffing .......................................................... 11 6.5 JNC Activation .......................................................... 12 6.6 JNC Operations .......................................................... 13 6.7 JNC Position Instructions .......................................................... 18 6.8 JNC Activities during Recovery Phase .......................................................... 18 6.9 JNC Deactivation .......................................................... 19
7.0 REFERENCES
.......... 19 8.0 ATTACHMENTS Attachment 1: IP Communications Representative Checklist ............................................... 21 Attachment 2: IP Government Liaison Representative Checklist .............................................. 23 Attachment 3: JNC Director Checklist ............................................... 24 Attachment 4: Company Spokesperson Checklist .................... ........................... 29 Attachment 5: JNC Technical Advisor Checklist .................... ........................... 33 Attachment 6: Technical Briefer Checklist ................................................ 35 Attachment 7: Administrative Manager Checklist .................... ........................... 36 Attachment 8: JNC Writer Checklist ............................................... 40 Attachment 9: Agency Liaison Checklist ............................................... 44 Attachment 10: Media Room Manager Checklist ........................................... 46 Attachment 11: Media Room Liaison Checklist ............................................ 53 Attachment 12: Audiovisual Coordinator Checklist .......................................... 54 Attachment 13: AVAGraphics Staff Checklist ............................................... 55 Attachment 14: Public Inquiry Coordinator Checklist .................... ........................... 58 Attachment 15: Public Inquiry Staff Checklist .............................................. 59 Page 2 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Table of Contents (cont.
Attachment 16: Media Referral Staff Checklist .............................................................. 60 Attachment 17: Media Monitoring Staff Checklist .............................................................. 62 Attachment 18: JNC Documenter Checklist .............................................................. 63 Attachment 19: JNC Administrative Support Staff Checklist Attachment 19a: JNC Registration Coordinator Checklist ............................................. 65 Attachment 19b: JNC Administrative Support Staff Checklist ....................................... 66 Attachment 20: IT Representative Checklist .............................................................. 68 Attachment 21: OPTIONAL POSITION: Radiological Advisor Checklist .................................... 69 Attachment 22: Radiological Health Expert Checklist .............................................................. 70 Attachment 23: JNC Security Checklist .............................................................. 71 Attachment 24: Emergency Operations Facility (EOF) Information Liaison Checklist ............... 72 9.0 ADDENDUM Addendum 1: JNC Location Map and Floor Plans ............................................................. 73 Addendum 2: JNC Functional Organization Chart ............................................................. 76 Addendum 3: EOF to JNC Essential Information Checklist (Form IP-101 1-1) .......................... 77 Addendum 4: Media Briefing Issues (Form IP-1011-2) ............................................................. 78 Addendum 5: JNC Staffing (Form IP-1011-3) ............................................................. 79 Addendum 6: Emergency Summary Sheet (Form IP-1011-4) .................................................. 83 Addendum 7: Written Statement Distribtion Checklist (Form IP-1 011-5) ................................... 84 Addendum 8: Information Distribution Guide (Form IP-1011-6) ................................................. 86 Addendum 9: Rumor Control-Media Monitoring-Media Response (Form IP-101 1-7) ................ 87 Addendum 10: Fax Distribution ..................... 88 Addendum 11: JNC Briefing Notes (Form IP-1011-8) ...................................... 91 Page 3 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Joint News Center (JNC)
1.0 INTRODUCTION
1.1 The JNC supports the emergency response plans of Entergy, the State of New York and Westchester, Putnam, Rockland and Orange County organizations that would respond to an emergency at the plants. The functions, processes, facilities and organization described in the manual support those agencies, as well as the U.S.
Nuclear Regulatory Commission (NRC) and the Federal Emergency Management Agency (FEMA).
1.2 This Joint News Center Operations Manual describes the basic functions, processes and facilities that support operation of the JNC. It also establishes Entergy policies on release of emergency information and interaction with other response agencies at the JNC.
1.3 This manual addresses:
1.3.1 Process and provisions for staff notification and facility activation 1.3.2 The organizational structure of the JNC staff 1.3.3 Flow of information to and within the JNC 1.3.4 Preparation and review of information for dissemination to the news media 1.3.5 Interaction with other agencies at the JNC 1.3.6 Facility operation 1.3.7 Equipment and supplies.
1.4 Detailed information on the responsibilities of JNC positions and reference materials for individuals filling those roles are provided in this manual, as well as in JNC Position Binders maintained at the JNC.
2.0 PURPOSE 2.1 To describe the methods used by the Indian Point (IP) Emergency Response Organization to provide timely and accurate information to:
2.1.1 State and County Public Information Officers 2.1.2 NRC and FEMA Public Information Officers 2.1.3 The News Media 2.1.4 Members of the Public 2.1.5 Employees.
2.2 To describe the activation and operation of the Joint News Center (JNC).
2.3 To describe the coordination between IP Communications and the IP Emergency Response Organization during emergencies at the plant.
Page 4 of 91
1P2 IP-1011, Joint News Center, Rev. 6P IP3 JNC Operations Manual 3.0 DISCUSSION/OPERATIONS 3.1 The primary functions of the JNC are to:
3.1.1 Provide timely information to the media, through briefings or written statements such as news releases, on plant conditions and on emergency response actions being taken to protect the public.
3.1.2 Develop and disseminate emergency advisories to the public in the 10-mile Emergency Planning Zone (EPZ) through the Emergency Alert System (EAS). (Responsibility of the Counties and State.)
3.1.3 Conduct media referral, media monitoring, and public inquiry response operations to ensure that the public receives accurate and timely information.
3.2 The JNC, located at the Westchester County Airport, is the central facility for dissemination of information to the news media regarding Indian Point during emergencies.
3.2.1 Accommodations for representatives of Entergy, New York State, the counties of Westchester, Rockland, Putnam and Orange, NRC and FEMA are located within the JNC. The JNC is considered fully activated once there is sufficient staff, and communications have been established with the counties and state to perform the above three principal functions. Entergy will notify news organizations by faxed media advisory or news release that the JNC has been activated. The decision to terminate JNC operations will be a cooperative one reached by the chief elected officials, the state and Entergy.
3.2.2 The JNC occupies two floors of Building #1 at the Westchester County Airport (see Addendum 1 for floor layouts) and is designed to support the flow of information to the news media and the public on emergency status and response associated with Indian Point.
3.2.3 The JNC Director is responsible for the Entergy JNC staff, and to ensure the information dissemination process is implemented effectively and content issues are addressed. The JNC Administrative Manager is responsible to ensure the operability and functionality of the facility. The IT Representative will support this effort by ensuring all Information Technology (IT) and computer equipment is operating properly.
3.3 Upon declaration of an Alert (or more severe emergency classification), the JNC is activated and staffed by Entergy, the four counties and New York State. The facility may also be staffed sooner and/or at other times at the discretion of Entergy senior management and communications personnel. An organization chart is contained in Addendum 2 depicting all of the initial communications response and JNC positions.
3.4 Prior to JNC activation, IP Communications in conjunction with the Onsite Emergency Response Organization maintains responsibility for the dissemination Page 5 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual of information to the media. Accomplishment of these responsibilities requires close coordination, as described in this procedure.
3.5 Before the Emergency Operations Facility (EOF) is activated, the IP Communications Representative serves as the communications link between the Indian Point Emergency Response Organization and Entergy Communications/Media Relations. After EOF activation, the EOF Information Liaison is assigned to facilitate continued sharing of information among the EOF, IP Communications and/or the JNC, if activated.
3.6 Once the JNC is activated, the JNC Director is the senior communications person at the JNC for Entergy, and is responsible for the communications strategy and implementation of successful information dissemination. The Company Spokesperson is the lead Entergy official and serves as the source of all statements and information disseminated from the JNC from Entergy.
3.7 The three major steps in the flow of information are gathering, processing (including review) and distribution.
3.7.1 Gathering Information: The Emergency Operations Facility EOF) and the plant organization serve as primary sources of information for the JNC. If necessary, an Alternate EOF or AEOF may be activated, and all staffing including the EOF Information Liaison will be established at the alternate site. Additionally, a "recovery center," if activated, may provide information to the JNC.
- The EOF Information Liaison is assigned to the EOF, if activated, to gather and relay information to the JNC. The EOF Information Liaison is a technical advisor, and is familiar with the EOF operations and how to obtain necessary information to support JNC needs. The EOF Information Liaison relays changes in plant status and new information as quickly as possible to
- Direct ring-down telephone lines between the JNC and EOF are designated to relay information. If the AEOF is activated the EOF Information Liaison will establish contact with the JNC on regular telephone lines.
- Information is conveyed from the EOF Information Liaison to the JNC Technical Advisor verbally, electronically and via fax. The EOF to JNC Essential Information Form (Addendum 3) is used to convey information electronically.
- Copies of Radiological Emergency Data and plant status forms are faxed from the EOF (or AEOF) to the JNC. Additionally, some plant data is available online through computer access at the JNC.
3.7.2 Processing and Review: The JNC staff organizes information on the plant and confirms its accuracy, sharing it with State and County representatives at the JNC, before releasing it to the news media.
Page 6 of 91
1P2 IP-1011, Joint News Center, Rev. 6 I133 JNC Operations Manual
- Events and information provided from the plant are logged on a running plant status log (flip chart) by the JNC Technical Advisor in the utility workroom.
- The JNC Writer prepares written statements (news releases, media summaries, media advisories and chronologies) to provide written documentation of events and response activities, as well as to document summaries of information provided at the Media Briefings for further distribution.
- The Company Spokesperson develops talking points based on available information in preparation for Media Briefings.
3.7.3 Distribution and Feedback: Information is released from the JNC to the news media verbally through Media Briefings and in writing via various forms of written statements, including news releases, media briefing summaries, chronologies etc. The JNC staff supports a broad distribution of all written statements. Both the Company Spokesperson and the Public Inquiry staff provide information verbally. Feedback is received via the Public Inquiry, Media Referral and Media Monitoring functions, as well as from the JNC staff.
a ALL JNC Written Statements are distributed to JNC work areas, state and county representatives, the utility bulletin board, other emergency facilities and the news media. Distribution involves copying, faxing and electronic distribution.
- The Company Spokesperson is the Entergy representative who serves as the source of all information and provides formal statements to the news media in Media Briefings, and via written statements.
- Immediately after each briefing, the JNC Director and JNC Technical Advisor update the Company Spokesperson on plant status and developments, and provide feedback on the briefing conduct, open questions and issues.
- The Public Inquiry Coordinator (PIC) gathers reports of rumors, misinformation, errors and other areas of concern as garnered from callers in the Public Inquiry and Media Referral work areas, and from the Media Monitoring staff based on media reports. Resolution of these rumor or error reports are coordinated between the PIC, JNC Director and the Public Information Officers (PIO) from the State and Counties. The State provides a Public Inquiry Supervisor in the Public Inquiry work room, with whom the PIC coordinates all activities.
3.8 This procedure describes the activation and operation of the JNC for Indian Point emergencies.
4.0 PRECAUTIONS AND LIMITATIONS None Page 7 of 91
IP2 P-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual 5.0 EQUIPMENT AND MATERIALS 5.1 The following documents list some of the equipment and supplies available at the Joint News Center:
5.1.1 The attachments to this Implementing Procedure for JNC Administrative Manager and Audiovisual Coordinator.
5.1.2 Indian Point Unit #2, EP-AD-05, Emergency Facilities and Equipment 5.1.3 Indian Point Unit #3, JNC Inventory.
6.0 INSTRUCTIONS 6.1 Notification to IP Communications, Other Entergy and Joint News Center Staff 6.1.1 The JNC notification process uses ERO pager system and/or the Community Alert Network (CAN) telephone system. Other Entergy Communications personnel, including White Plains Office personnel, are informed of events by either pager or direct contact.
6.1.2 The P2 and P3 Control Rooms notify the Duty IP Communications Representative during emergencies.
6.2 Initial Actions 6.2.1 When notified by pager/phone or upon hearing the emergency assembly alarm, the IP Communications Representative initiates the initial communications response. Written statements are prepared, approved and issued via the IP Communications Representative, using the following steps:
- Obtain Information
- DetermineInitial Response
- Draft Written Statement
- Written Statement Review and Approval
- Provide Courtesy Calls to Outside Agencies and Officials
- Distribute Written Statement 6.2.2 The IP Communications Representative shall ensure the following steps are completed:
Take immediate action to:
Ascertain current plant conditions, time of event, emergency action level, and the emergency classification level, radioactive release above/below federally approved limits, The IP Communications Representative Page 8 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual notified of the emergency situation obtains available information to support preparation of the written statement:
Emergency Classification Level (ECL), and time declared;
- Emergency Action Level (EAL) number and description;
- Summary description of plant events; Any other information, at a summary level, considered important for initial written statement(s).
Maintain a written log of information, including date, time and information source(s) and then:
- Notify via pager or direct contact the P Government Liaison Representative(s) to make required local courtesy notifications.
Based on the number of IP Government Liaison Representatives available, divide the call lists among them to ensure prompt notification of both Group 1 and Group 2 calls (The contact lists are the same for either an P2 or P3 event). The calls should inform these local and other officials of the event underway and the planned issuance of a news release. (See the "Group #1 and Group #2 Notifications" call lists located in the IP Emergency Telephone Directory in the position binders and on P2web/eplan.) The IP Government Liaison Representative(s) should confirm completion of all notifications with IP Communications Representative.
- If necessary, notify the local officials directly using the Group 1 and/or Group 2 call lists, informing them of the event underway and the planned issuance of a news release. (See the "Group #1 and Group
- 2 Notifications" call lists located in the IP Emergency Telephone Directory on P2web/eplan.)
- Develop an initial news release based on available information (using Inventory of Boilerplate News Releases, suggested phraseology and Emergency Action Level descriptions available in the Emergency Communications Guide, on the P2web/eplan and CDs available in the position binders, and in the EOF and JNC. (Note that Written Statements should be issued within one hour of emergency classifications, if possible).
6.2.3 In general, news releases will be issued under the following circumstances:
- Any emergency declaration at either Indian Point Unit 2 or Unit 3 (Notification of Unusual Event, Alert, Site Area Emergency, General Emergency).
Escalation in emergency classification.
Emergency event termination.
Page 9 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual
- Any accident resulting in fatality or serious injury.
- Release of radioactivity beyond the site boundary, in quantities exceeding those allowed by regulation.
6.2.4 BEFORE issuing any news release information, the IP Communications Representative will obtain approval of draft news releases from the Emergency Director (ED). Once the JNC is activated, technical review and concurrence should be gained from the ED. Confirmation of all local notifications (Groups #1 & #2 as noted above) should also be received before distribution to the media, if the JNC is not yet activated.
6.2.5 Distribute the news release(s) to media and wire services and to the designated local officials, using available fax machines in the office, home office and/or EOF. Media fax numbers are programmed into available machines, and/or use the laminated listing available at these machines.
The complete media contact list is contained in the IP Emergency Telephone Directory. Confirm that all news releases issued prior to the activation of the JNC are faxed to the EOF and the JNC facility.
6.2.6 Depending on circumstances, proceed to the EOF to obtain and communicate up-to-date information. Once activated, the EOF Information Liaison can assist in information gathering, and facilitate review and approval of news releases.
6.2.7 Coordinate with and provide the EOF Information Liaison with guidance, review and coordination as needed for the approval and distribution of additional news releases prior to JNC activation.
6.2.8 The EOF Information Liaison reports to the EOF, upon notification of decision to activate, and shall take immediate action to:
- Establish communications with EOF staff, the IP Communications Representative and JNC Technical Advisor, if the JNC is activated
- Obtain up-to-date information and begin to document available information on the EOF to JNC Essential Information Checklist (Form IP-1 01 1-1). Forward electronically or fax all completed forms to the JNC Fax/Copy Room, once JNC activation occurs.
- Coordinate the review and approval of news release(s) and the notifications of local officials in Groups #1 and #2 (noted above) with the IP Communications Representative, prior to JNC activation. Prior to JNC activation, approval should be obtained from the ED. After JNC activation, support the JNC by promptly obtaining technical concurrence from the ED on all written statements. The Company Spokesperson will approve news releases after the JNC is activated.
- Coordinate with the IP Communications Representative to distribute the news releases to the media, prior to JNC activation.
Page 10 of 91
IP2 IP-1011, Joint News Center, Rev. J IP3 JNC Operations Manual 6.2.9 Upon notification of the decision to activate the JNC, individuals assigned to the JNC should perform any initial actions outlined in their checklists, then proceed to the facility and prepare it for activation.
6.3 Emergency Communications Activities After JNC Activation 6.3.1 The JNC serves as the central facility for dissemination of information to the media and public. Upon JNC activation, media and public communications (written statements, media briefings) become the responsibility of the JNC.
6.3.2 Indian Point Communications staff and/or Entergy Media Relations in the White Plains office will provide continuing support, as appropriate, during the course of the event for distribution of news releases to Company management, Entergy employees and others as deemed necessary.
6.4 JNC Staffing 6.4.1 The staffing process will begin upon declaration of an Alert (or more severe emergency classification). When notified of the need for JNC activation, designated personnel shall report for duty at the JNC, or initiate duties from home, office or other locations, as defined by individual position checklists. The facility may also be staffed sooner and/or at other times at the discretion of Entergy senior management and communications personnel.
6.4.2 Full staffing of the JNC comprises Entergy positions, as well as state, county or other government personnel. Utility staffing of the JNC will take place within two hours of the declaration of an emergency (either Alert, Site Area Emergency or General Emergency). The following key positions should be filled before activation is declared (a full organization is depicted in Addendum 2). If necessary and appropriate, JNC management may need to re-assign appropriate staff to temporarily fill positions to facilitate activation. This should only be considered if circumstances warrant.
- JNC Director
- Company Spokesperson
- Administrative Manager
- JNC Technical Advisor
- Agency Liaison
- Audiovisual Coordinator and/or AV/Graphics (2 staff minimum)
- Media Room Manager
- Public Inquiry Coordinator
- Registration Coordinator*
- Security*
Page 11 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual
- All JNC staff are cross trained to perform these functions.
6.5 JNC Activation 6.5.1 In the-event of an Alert emergency declaration or higher, JNC staff activates as follows:
Plant staff who support the JNC:
If activation takes place during working hours, they are notified by beeper and plant public address system. Off-hours, they are notified by beeper and the CAN telephone system.
- Headquarters (White Plains Office) staff who support the JNC:
Ifactivation takes place during working hours, they are notified by beeper or at their workplace. Off hours, they are notified by beeper and the CAN telephone system, or called at their home.
- "All Call" for JNC Staff:
Upon notification, all JNC staff are expected to report to the JNC for duty. A shift roster will be defined once the initial response is under way. Additional personnel beyond the minimum staffing may be requested to support initial response. If necessary, the JNC Administrative Manager will utilize JNC administrative support staff to contact JNC personnel who have not yet arrived at the JNC to determine if and when they may arrive for response and shift planning purposes, using the Entergy phone listings.
6.5.2 Activation and sign-in instructions for positions reporting to JNC
- Upon notification, all JNC personnel proceed to the JNC, located in Building 1, the Westchester Airport, White Plains, New York (Airport Access Road - Exit 2,1-684) (See Addendum 1)
- Ifthe facility is not open, contact the Airport Operations Supervisor number located on the front entrance to facility, and proceed using those posted procedures.
Ask Airport Operations to unlock the facility (unlock doors, lobby closet, etc., deactivate alarm systems in lobby and Media Monitoring Room, and activate building systems (heat, air conditioning, lights, etc.)
- The initial person reporting should wait for a second person to arrive and set up registration desk sign-in process (registration book is in lobby closet). That person will staff registration process until Security or a Registration Coordinator arrives.
- Register in registration book
- Print name on Utility sign-in board outside Utility Room A, if filling 1st shift position Page 12 of 91
IP2 IP-1 01 1, Joint News Center, Rev. 6N IP3 JNC Operations Manual Proceed to assigned work location and refer to Position Binder and checklist, or if not 1 t shift, report to the cafeteria area and await further instructions.
6.5.3 The JNC Director reviews JNC activation requirements available in the JNC Director position binder to confirm the functional readiness of the facility before officially announcing the activation and opening the JNC. The JNC Director will coordinate (directly or via the JNC Writer and/or JNC Technical Advisor) with the IP Communications Representative to ensure a smooth transfer from the Initial communications response to the JNC.
The JNC will be declared activated when:
- Key positions are staffed by Entergy representatives;
- State and Counties have been notified and communications established (directly in the JNC and/or via Agency Liaison); and EAS capability is established by the Westchester County/State Representatives (confirmed directly in the JNC or via Agency Liaison).
6.6 JNC Operations Upon JNC activation, all media and public communications concerning the plant become the responsibility of the JNC under the overall direction of the JNC Director.
6.6.1 Information Gathering, Sharing and Coordination The JNC has access to all necessary information either directly or through the Emergency Operations Facility (EOF) and the Emergency Director. An EOF Information Liaison facilitates information flow from the plant to the JNC Technical Advisor. EOF to JNC Essential Information Forms are used to electronically convey information, in addition to telephone discussions, faxing of plant status and radiological forms, and access to some plant data directly. The JNC Technical Advisor and Company Spokesperson, along with the JNC Director, review and organize the information for dissemination to the media and public. If deemed necessary, the JNC Director, in coordination with the Company Spokesperson, may decide to activate the Radiological Advisor position, due to the potential or real radiological consequences of an emergency at Indian Point. The JNC Administrative Manager will arrange for notification of the Radiological Advisor, if necessary.
Information sharing among Entergy, state, county and federal public information staffs supports timely and coordinated release of information to the public and news media. The coordination assures all parties are aware of each other's actions concerning plant status, response and protective Page 13 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP33 JNC Operations Manual actions, public inquiry and media monitoring, and provides the opportunity to resolve inconsistencies.
If events at the plant warrant a change in emergency action level or there is a significant change in plant status regardless of a change in EAL, Entergy staff will be the first people at the JNC to learn of these events. The Agency Liaison shares preliminary information on changes with each agency lead, changes EAL signs and rings the bell located in JNC work areas.
Additionally, the Administrative Support Staff distributes copies of the Radiological Emergency Data forms, Parts 1 and 2, to each JNC work area, and ensures plant status summaries are posted in JNC work areas.
Information that will be presented at Media Briefings is first shared in either verbal or written form during pre-briefings. Final Entergy written statements are circulated among JNC participants for review and acknowledgment (not approval).
State and County representatives also circulate their news releases for review. The Agency Liaison reviews and initials the statements, relaying appropriate information to the JNC Director and/or Company Spokesperson and providing copies to the Administrative Manager for distribution. Federal agencies may participate in this review, as well.
Spokespeople for all parties participating in Media Briefings attend pre-Media Briefing conferences that are coordinated by the State, or the Company Spokesperson. Each party at the conference summarizes the status of their actions and the information they will present at the next briefing.
In the pre-briefings, the parties have the opportunity to resolve inconsistencies, address concerns, establish briefing protocol and set the order of speakers. The Media Room Manager facilitates the discussions, and establishes the sequence and ground rules as the Moderator of the Media Briefings.
Information flow at the JNC is supported by a closed-circuit television system, which transmits live Media Briefings to designated work areas in the JNC including the utility, state, county and federal agency and media work rooms.
6.6.2 Written Statements Written Statement preparation entails compiling and reviewing plant information, drafting and reviewing written statements, obtaining approval or concurrence, obtaining State and County concurrence, conducting courtesy notifications, and distribution.
Written Statements are issued upon JNC activation, after changes in emergency classification (escalation), based on unfolding events related to the emergency, to provide summaries and chronologies, and upon JNC deactivation. Written statements are also issued under the following Page 14 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual circumstances:
- A fatality or serious injury
- Release of radioactivity beyond the site boundary, in quantities exceeding those allowed by regulation X Personnel exposures to radiation exceeding limits allowed by regulation Written statements include news releases, media briefing summaries, chronologies, media advisories, backgrounders, etc. Written statements may also be issued under other circumstances by the JNC staff.
Written Media Briefing Summaries are developed by the JNC Writer during and immediately following each Media Briefing, and are designed to capture some of the detail and descriptions of the unfolding situation and response efforts.
- The summary should be concise (two-to-three pages maximum).
- The first paragraph identifies the time and number of the briefing, the event and the Entergy spokesperson.
- The target for a completed draft, ready for review, should be within 15-30 minutes after the end of the briefing.
The normal sequence of steps in written statement preparation is:
- a. Information Gathering -The JNC will have access to necessary information either directly or indirectly from the plant. An EOF Information Liaison will facilitate information flow between the plant personnel and the JNC Technical Advisor.
- b. Draft Written Statement - The JNC Writer, with guidance as needed from the JNC Technical Advisor, Company Spokesperson and JNC Director, prepares draft written statements.
- c. JNC Review- JNC personnel, usually the Company Spokesperson, JNC Director andlor JNC Technical Advisor review draft written statements and propose changes as needed. The JNC Writer makes edits based on input received.
- d. Technical Concurrence - Written Statements are also reviewed by the Emergency Director for technical accuracy. Note: The intent of the EOF concurrence is to ensure that Written Statements are technically accurate. It is not intended that EOF reviewers judge or influence the emergency communications strategy.
- e. PrepareFinal Copy-At the direction of the Company Spokesperson and JNC Director, the JNC Writer prepares the final (for approval) copy. Final statements are printed with time and date, contact name and phone number.
Page 15 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual
- f. Approval- The Administrative Manager stamps the back of the final written statement, and the Company Spokesperson initials for approval. The Utility Room Documenter documents this in the log and on a status board. The Administrative Manager completes a Written Statement Distribution Form and Fax Distribution form for further acknowledgements and distribution.
- g. Federal, State, County and Local Official Notification - The Agency Liaison advises the state and county PlOs of impending written statements, and documents acknowledgment of final statements concurrently with making internal distribution to them. If NRC and FEMA PlOs are present, they are included in this process. The PlO emergency conference phone is used to inform absent state and county PlOs, and pre-designated local officials.
- h. Distribution - The Administrative Manager coordinates prompt copying, faxing and distribution of all written statements by the Administrative Support Staff to the media, to other emergency response facilities, other Entergy locations, and to all JNC workrooms and areas.
6.6.3 Media Briefings Media Briefings can be called for by Entergy, the State or Counties, NRC or FEMA as significant events occur or critical information becomes available.
Planning and scheduling Media Briefings is done by consensus of the participants through coordination by the Agency Liaison and the state representative. As a general rule, Media Briefings will be scheduled following (usually within one hour) changes in emergency classification, significant changes in plant status, other major events related to the emergency and for periodic updates during extended emergency situations.
The Pre-briefing meetings with the PlOs are held prior to briefings, and are coordinated by the Agency Liaison. During Media Briefings, Entergy takes the lead in moderating the briefings. The JNC Media Room Manager performs the function of Moderator during Media Briefings. Each JNC representative will provide a briefing statement and answer questions directed to them by the Moderator. The Technical Briefer and Radiological Health Expert positions remain available to the news media in the Media Briefing Room to provide background information and descriptions of plant operations.
Media Briefings at the JNC generally involve Entergy, as well as state, county and, possibly, federal agency representatives. Media Briefing preparations entail:
- compiling and reviewing plant information,
- sharing information with other JNC participants,
- preparing talking points, supporting documents, maps and graphic materials, and a coordinating the Media Briefing with the other participants.
Page 16 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual These pre-briefings assure the accuracy of information presented and allows for resolution of concerns or inconsistencies.
- The Company Spokesperson prepares briefing notes or talking points, with the assistance of the JNC Technical Advisor and JNC Director. The notes are generally prepared to address the major topics of 'What Happened", 'What we are doing about it", and 'What are its implications".
- JNC Media Briefings usually follow classification changes, major events or significant actions by Entergy, State or Counties within 30 to 60 minutes. This target is generally consistent with the communication objective of State and County participants.
- The Company Spokesperson identifies support materials needed for briefings to summarize key information, clarify plant systems and components and illustrate explanations. The Company Spokesperson coordinates production or availability of graphics, photographs or other materials with the JNC Administrative Manager and Audiovisual Coordinator
- The Media Room Manager announces each Media Briefing over the public address system shortly before the scheduled starting time.
Information is presented to the news media in a large briefing room located on the 2nd floor of the facility, near work spaces established for the media.
The stage at the front of the Media Briefing Room holds the podium, easels, projection screen and a table with microphones and chairs for JNC spokespersons. The rear of the room has a raised camera platform and audiovisual control room. The main area of the room has chairs for news briefing attendees. Audiovisual equipment is available to display diagrams, overheads, slides, videotapes and an Emergency Response Planning Areas map. Stock video footage and photographs are also maintained for distribution to media representatives.
The Media Room Manager and Media Room Liaison(s) provide assistance to the news media present in the JNC, ensuring their needs are being met and assisting with special information requests. They also ensure the news media work within the ground rules established for their participation in the JNC.
The JNC Director, Technical Briefer, Radiological Health Expert, and JNC Technical Advisor (time permitting) monitor the content and accuracy of each briefing (via the closed circuit televisions in the work areas) to identify any inaccuracies and inconsistencies in the Media Briefings. Unanswered questions are also documented for follow up by the Media Room Manager.
The Radiological Health Expert and Technical Briefer provide their comments to the Media Room Manager at the conclusion of the Media Briefing. The JNC Director and Company Spokesperson review the Page 17 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual comments and note items to be addressed at the next briefing, or in written statements.
6.6.4 Other JNC Communications A combination of State, County and Entergy personnel staff Public Inquiry, Media Monitoring and Media Referral functions. The Public Inquiry team provides the public with clarification of information. Media Monitoring tracks the accuracy of broadcast and print reports. Media Referral handles telephone inquiries from off-site media that cannot come to the JNC. An Entergy Public Inquiry Coordinator (PIC) supervises the assigned staff, which is made up of state, county and utility personnel, unless and until the state Public Inquiry Supervisor arrives and assumes this responsibility: Mis-information or rumors are corrected at Media Briefings, in written statements or by contacting the station, publication or reporter. The PIC, JNC Director and State coordinate on the appropriate corrective response, and the PIC tracks to resolution.
6.7 JNC Position Instructions 6.7.1 Attachments 1 through 24 are checklist instructions for JNC positions. The person(s) responding for each of these positions shall use the appropriate checklist and associated and referenced tools to perform their assigned duties.
6.7.2 The checklists include position responsibilities relative to mobilization, activation and deactivation activities, and ongoing activities.
6.7.3 In addition, supplemental emergency communications guidance and reference material is contained in the Indian Point Emergency Communications Guide, maintained in the JNC, EOF on CDs and on the Entergy (P2) WEB.
6.8 JNC Activities During Plant Recovery 6.8.1 The Emergency Director and/or Recovery Manager will advise the Company Spokesperson (or JNC Director) to develop a recovery action plan (Issues/Strategies) and determine ongoing JNC staffing requirements for Recovery.
6.8.2 The Company Spokesperson (or JNC Director) will participate in a joint conference with the P2 Emergency Plant Manager or P3 Emergency Director, to:
- Review the recovery issues/strategies action plan.
- Review the JNC recovery staffing requirements.
6.8.3 The JNC may remain activated for some time after event termination during Recovery.
Page 18 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual 6.8.4 The Recovery Manager will continue verification and approval of information released by the Company Spokesperson that pertains to the emergency or recovery from the accident.
6.8.5 The news media should receive a final status report on the emergency and recovery operations, prior to the Recovery Manager terminating the recovery phase.
6.8.6 The Company Spokesperson (or JNC Director) should continue to identify and document issues relating to recovery operations and construct and implement the Recovery Plan for Public Information activities.
6.9 JNC Deactivation 6.9.1 When the ED terminates the emergency or at some point during Recovery, the decision to terminate JNC operations will be a cooperative one reached by Entergy, chief elected officials and the state, and will be made once the following conditions have been met:
- The establishment of a plan to continue sharing event related information and handling post-closing queries
- The collection and preservation of documents relating to the event.
6.9.2 The deactivation will be announced both at a close-out Media Briefing and by Entergy issuing a media advisory announcing the termination of JNC operations, with points of contact for follow on inquiries.
6.9.3 At the conclusion of JNC operation, the following actions shall be taken:
- The JNC Director or designee will conduct a debriefing. The JNC Director will determine participation in the debriefing.
- The JNC Director or designee will note comments at the debriefing.
- A written critique will be prepared by the JNC Director or designee for submission to the Emergency Planning Manager.
- The complete log of the event will be given to the Emergency Planning Manager for retention.
- Closing procedures will be performed at the direction of the Administrative Manager and JNC Director and will follow the procedures within each position checklist.
- ALL JNC personnel are expected to restore their work areas to startup condition prior to departing the facility
7.0 REFERENCES
7.1 Development Documents 7.1.1 Emergency Plan for Indian Point Unit Numbers 1, 2 and 3, Section 8.0 Page 19 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual 7.2 Interface Documents 7.2.1 Indian Point Unit 2 Documents:
- Emergency Plan, Section 5.0
- IP-1 030, Emergency Operations Facility
- IP-1 002 Emergency Notification and Communication
- IP-1048, Termination and Recovery 7.2.2 Indian Point Unit 3 Documents:
- Emergency Plan, Volume I, Section 5.0
- AP-8.3, DER Operability and Reportability Review by Operations
- IP-2312, Emergency Operations Facility
- IP-2500, Security Emergency Activation Procedures
- IP-2602, Development of a Recovery Action Plan 7.2.3 Entergy Documents:
- Indian Point Emergency Communications Guide 7.3 Commitments 7.3.1 This procedure implements the following P2 requirements/commitments:
- NL-00-1 11-C01
- NL-99-116-C13
- NL-81-157-C41 8.0 ATTACHMENTS See Table of Contents 9.0 ADDENDUM See Table of Contents Page 20 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 I133 JNC Operations Manual Attachment 1 IP Communications Representative Checklist Sheet 1 of 2 Primary Responsibilities Serve as primary information gatherer and communications representative during initial conditions; initiate courtesy notification process for local and other officials and public information officers relative to the event and impending external dissemination of information to the media: prepare and get approved initial news release(s); distribute approved news releases; and, report to the EOF if appropriate Mobilization and Activation Activities Notes 1.0 While at office or at home Upon initial notification of the event by plant, obtain as much information as is available (Utilize Addendum 3, Form IP-1011-1, EOF to JNC Essential Information Checklist, as appropriate):
- Emergency Classification Level (ECL) and time declared
- Emergency Action Level (EAL) number
- Any radioactive material release, above or below federally approved limits
- Brief description of plant events
- Written Statement preparation entails compiling and reviewing plant information, drafting and reviewing written statements, obtaining approval or concurrence, conducting courtesy notifications, and distribution.
- Refer to position binder and checklist Operational Activities 2.0 Ongoing Responsibilities Receive pager notice of messages left on the designated IP Communications Representative phone line (271-7001). To retrieve messages, dial the number, enter extension 7031, and password 7031 to retrieve messages.)
- Notify/coordinate with the IP Government Liaison Representative(s) to make required local official courtesy notifications. Based on the number of Government Liaison Representatives available, divide the call lists among them to ensure prompt notification of both Group 1 and Group 2 calls. (All IP Government Liaison Representatives are paged along with the ERO, and are expected to establish contact with you upon notification by leaving a message on 271-7031.
- The courtesy calls should inform the officials of the event underway and the planned issuance of a news release. (See the 'Group #1 and Group #2 Notifications" call lists located in the IP2 Emergency Telephone Directory on IP2web/eplan.)
- The IP Government Liaison Representative(s) should promptly confirm completion of all notifications with IP Communications Representative.
Develop an initial news release based on available information, using the following:
- Inventory of Boilerplate News Releases contained in the Emergency Communications Guide, on the IP2web/eplan and CDs in the position binder, and available in the EOF and JNC. Utilize the Entergy News Release Template and Guidance, as contained on the above mentioned CD and in the Emergency Communications Guide.
Page 21 of 91
lP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 1 IP Communications Representative Checklist Sheet 2 of 2 2.0 Ongoing Responsibilities (cont'd.) Notes
- A written log of information must be maintained, including date, time and name of source(s) furnishing information (use Emergency Response Organization Log Sheet form IP-1023-4, Addendum 8) In general, news releases will be issued under the following emergency circumstances:
- Any emergency declaration at IP (Notification of Unusual Event, Alert, Site Area Emergency, General Emergency).
- Escalation in emergency classification.
- Emergency event termination.
- Any accident resulting in fatality or serious injury
- Release of radioactivity above or below federally approved at or beyond the site boundary, in quantities exceeding those allowed by regulation
- BEFORE issuing any news release information, the IP Communications Representative must obtain technical review and approval of draft news releases from the Emergency Director (ED). Confirmation of all local notifications (Groups
- 1 and #2 noted above) should also be received before distribution. If JNC is activating at/near the time of news release completion, coordinate with the Company Spokesperson and ED on approval.
- Distribute the news release(s) to media and wire services, and to the EOF, JNC and other Entergy locations using Addendum 9, Entergy-JNC Fax Distribution.
Or, coordinate distribution with the EOF Information Liaison.
- Provide the EOF Information Liaison with guidance and coordination as needed for the approval and distribution of additional news releases prior to JNC activation.
- Maintain contact with the plant or EOF Information Liaison once staffed for updated information on plant status, and until responsibility for the development and issuance of emergency information is transferred to the JNC, once activated.
Depending on circumstances, the IP Communications Representative may proceed to the EOF to obtain and communicate up-to-date information.
- As primary point of contact for the media (as listed on any disseminated news releases), remain available at phone number provided on news releases to handle media inquiries until the JNC is activated. Complete Media Inquiry Log below to document all media calls.
- Coordinate a turn over of the communications responsibilities with the JNC Director directly, or through discussions with the JNC Writer and/or via the EOF Information Liaison.
3.0 Post Event
- Make a formal turnover (in person or via phone) to the JNC Writer or JNC Director of the responsibilities for providing information to the JNC on the event.
- Notify the JNC Director of the completion of your duties as IP Communications Representative, and remain available for further assignments if necessary
- Gather all forms generated and provide them to the JNC Director Page 22 of 91
IP2 P-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 2 IP Government Liaison Representative Checklist Sheet 1 of 1 Primary Responsibilities Under the direction of the IP Communications Representative, serve as information liaison with local government officials by placing initial courtesy notifications to pre-defined individuals regarding the event underway and the pending release of information to the media and public Mobilization and Activation Activities Notes 1.0 While at home or office
- Receive plant page and/or call from IP Communications Representative and directions regarding assignment of calls (from Group #1 and Group #2 in the P2 Emergency Telephone Directory on IP2web/eplan). Calls are divided for assignment based on the number of IP Government Liaison Representatives that are available to the IP Communications Representative
- If contacted by pager, call 914-271-7031 and leave a message for the IP Communications Representative of where you can be reached to place calls.
- When contacted, coordinate on process to confirm completion of calls with IP Communications Representative. Use the 917-271-7031 messaging system, if appropriate.
X Upon receiving plant information on initial plant conditions from IP Communications Representative Contact assigned officials listed on Group #1 and/or #2 call list, informing them of the event underway and the planned issuance of a news release. (See the "Group #2 Notifications" call list located in the P2 Emergency Telephone Directory on P2web/eplan and in the position binder) Use the following script as a guide, if necessary:
'Hi, my name is ......... I 'm representing the Indian Point Energy Center as a Government Liaison Representative.
I'm calling to inform you that....
(provide the event information provided by the IP Communications Representative)
This is all the information that I have at this point. Entergy will be issuing a news release regarding the event.
Should I continue to call you at this number if I need to contact you again?"
Promptly notify IP Communications Representative upon completion of assigned calls (the IP Communications Representative will be faxing news releases to the Buchanan, Cortland and Peekskill officials as part of distribution)
Remain available to repeat steps if needed. Coordinate ongoing needs with IP Communications Representative, and arrange to provide all documentation of calls Contact Agency Liaison in JNC to coordinate on continuing contact of local officials, and notify JNC Director of availability for other appropriate assignments, once JNC is activated I Page 23 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 3 JNC Director Checklist Sheet 1 of 5 Primary Responsibilities Reporting to the Emergency Director, supervise and direct JNC staff, establish and maintain emergency communications strategy; ensure operation of the JNC facilitates the flow of information from the plant and emergency facilities to the state, counties, federal agencies, news media and public; assist in and declare JNC activation; direct shift and personnel changes; conduct periodic utility room briefings; manage and oversee all communications processes in the Utility Room A; and ensure corrective actions are taken and documented to address rumors and mis-information (with Public Inquiry Coordinator).
Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Go through registration, sign in on Sign-In Board outside of the Utility work rooms, report to Utility Room A and refer to position checklist (if 1 shift position is filled, notify the 1Vt shift JNC Director of your arrival and report to the cafeteria until further directions are provided)
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Obtain status on JNC staffing and set-up activities, and provide direction as necessary to complete a first shift roster. Direct Administrative Manager to verify Security personnel have been notified and are reporting, if not already present.
- Assume title of JNC Director and overall responsibility of facility, staff, and operations. Direct the JNC Technical Advisor establish the time with the EOF, and instruct the Administrative Manager to synchronize all clocks, time stamps, fax machines, etc.
- Call directly, or confirm that either the Company Spokesperson or JNC Technical Advisor is establishing contact with the IP Communications Representative and/or EOF Information Liaison to confirm JNC activity and obtain updates and review news release(s) issued prior to JNC activation.
- All new releases issued prior to JNC activation should be available on the JNC facsimile machine in the Fax/Copy Room. JNC Administrative Support Staff should be instructed to make copies for direct distribution within the JNC
- Ensure all staff refer to their detailed position checklists, and support set up and activation efforts
- In preparation for declaring the JNC activated, review the JNC Activation Considerations checklist (see below) to ensure readiness
- ActivationDeclaration: Declare JNC activated and operational when:
- 1. Key positions are staffed with Entergy representatives (See Sign In Board outside Work Room A for key staff designators) and;
- 2. Information is obtained to support communications functions;
- 3. Communications with state and counties have been established;
- 4. EAS capability has been established (via Westchester County representative and/or upon notification from the Agency Liaison)
Page 24 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 3 JNC Director Checklist Sheet 2 of 5 JNC Operational Activities Notes 2.0 Ongoing Responsibilities Upon activation, notify key JNC managers, State and County representatives that the JNC is activated, and request they inform all other appropriate staff.
Direct staff to synchronize the clock times between EOF and JNC.
- Direct finalization (by JNC Writer) of media advisory announcing the activation of the JNC as the official source of information to the public
- Establish and maintain command and control over the JNC overall operations
- Maintain Utility Room A status board noting utility briefing times, scheduled pre-briefing and Media Briefing times, and communications strategy/priorities
- Review plant status reports, news releases, EAS messages and other related information as it becomes available
- Begin formulating communications strategy and priorities (along with Company Spokesperson)
- Conduct periodic briefings with Utility Staff keeping them apprised of changing events, JNC priorities and other important information. If possible, ensure key staff are present in Utility Room prior to providing updates, including ..
Company Spokesperson, Agency Liaison, and Administrative Manager
- Ensure the coordination of information and timely, accurate communications flow within and out of the Utility Room A, and especially to the media
- Direct appropriate rest periods and shift changes for Entergy personnel (working with Administrative Manager). Confirm 2 nd shift staff assignments with the Administrative Manager, and advise the Emergency Director upon completion of a 2nd shift roster
- Coordinate with the PIC on needed corrective actions to address rumors, incorrect information or news reports identified by those functions. Assign utility corrective actions to JNC staff, and notify the PC of completion of the corrective actions.
3.0 Written Statements
- Monitor the development of written statements to ensure the process functions smoothly, ensuring appropriate timing/scheduling of written statements, appropriate communications focus and orientation, and facilitating timely approval and distribution
- Review written statements as required to provide communications input
- Ensure JNC Writer makes revisions as necessary based on input, and direct Administrative Manager to supervise proper distribution and support immediate copy/access needs
- Monitor written statement development and review time, working with JNC Documenter to track timing
- Ensure prompt review and concurrence of written statements by Emergency Director (working through the JNC Writer and Technical Advisor), approval of written statements by Company Spokesperson and distribution by the Administrative Manager.
Page 25 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 3 JNC Director Checklist Sheet 3 of 5 4.0 Media Briefings Notes
- Assist Company Spokesperson, as needed, to compile Media Briefing notes and messages. Each briefing should focus on three areas of information:
what happened; what we're doing about it; and what it means. In preparing notes for briefings, ensure any unanswered questions, inconsistencies and inaccuracies from previous briefings are noted
- Ensure the Media Room Manager is promptly advised of the times for Pre-Briefings and Media Briefings, and ensure timely announcements to the media are made. This can be done by telephone, or in person using the Agency Liaison or other appropriate staff.
- Ensure JNC Technical Advisor updates the Company Spokesperson on plant and Utility Room A activities during his/her absence for Media Briefings or other activities
- Monitor Media Briefings for salient content points, for follow-up and unanswered questions. Ensure the Technical Briefer, Radiological Health Expert and JNC Technical Advisor, ifavailable, document open items on a Media Briefing Issues form (Form IP-1011-2)
- Review media questions collected by Media Room Manager, Technical Briefer and Radiological Health Expert to assist in preparing notes for future Media Briefings, in preparing the Company Spokesperson and for inclusion in written statements, if appropriate 5.0 Recovery Support Activities
- Receive request from the Emergency Director to assist in developing an Recovery Action Plan, including identifying Issues/Strategies and determining the JNC Recovery Organization staffing requirements. Coordinate this activity with the Company Spokesperson
- Coordinate with the Company Spokesperson to participate in a joint conference with the P2 Emergency Plant Manager or P3 Plant Operations Manager, convened by the ED, to:
- Review the recovery issues/strategies action plan.
- Review the JNC recovery staffing requirements.
- Receive verification and concurrence of written statements from the Recovery Manager. The Recovery Manager will continue verification and approval of information released by the Company Spokesperson that pertains to the emergency or recovery from the accident.
- Ensure the Company Spokesperson provides a final Media Briefing on the emergency and recovery operations, prior to the Recovery Manager terminating the recovery phase Page 26 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 3 JNC Director Checklist Sheet 4 of 5 6.0 Post Event Notes
- When events warrant, after consultation with Entergy Senior Management and state and county representatives, declare JNC deactivated
- Direct JNC personnel to return all equipment to proper storage locations
- Conduct facility de-briefing
- Review all JNC documentation to verify that logs, forms and other documentation are complete
- Provide all documentation to the Emergency Planning Manager
- Return work area to startup condition before departing facility Page 27 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 3 JNC Director Checklist Sheet 5 of 5 JNC Activation Aide/Considerations (Foruse by JNC Director, or designee, to confirm JNC status in preparationfor Activation)
Security of JNC established Registration Process established/in place Utility Key Positions staffed
- Key Positions on Utility Sign InBoard complete
- State/County P10 Board complete or Current with remote contact (as needed)
- Position re-assignments complete to ensure desired shift/staff complement
= EAS Capability established (within JNC and/or at Westchester (EOC)
- Westchester County (and/or)
- State of New York Confirm presence of state and county personnel in JNC and/or determine likely arrival time (coordinate via the Agency Liaison on how initial dissemination of information will be managed if not present)
Media Briefing Room & Media Work Areas ready for use
=' Confirm if Media are present at the JNC CollateralActivities to Initiate and/or Confirm:
Administrative Manager has assigned responsibility for completion/confirmation of 2nd Shift assignments Release of 2nd shift personnel from JNC, after 2 nd shift assignment is made and they are informed of their assignments/reporting time. (Not necessary to keep personnel until the shift roster is complete)
Notify the Emergency Director of both JNC Activation and completion of 2nd shift roster Page 28 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 4 Company Spokesperson Checklist Sheet 1 of 4 Primary Responsibilities Working with the JNC Director, and Emergency Director, coordinate all outgoing information from the JNC and serve as primary source of information; review incoming plant/event information from EOF (via Technical Advisor), review and approve written statements, obtaining technical concurrence from the ED; develop briefing notes including relevant information and messages; conduct pre-briefings with state and county PlOs and Media Room Manager (moderator); serve as primary utility spokesperson at Media Briefings; respond to media questions as appropriate; ensure follow up and closure of open questions/correction of rumors and misinformation; coordinate with JNC Director and JNC Writer directly to ensure written statements reflect communications messages and content from Media Briefings.
Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Go through registration, sign in on Sign-In Board outside of Utility Room A and report to Utility Room A - refer to your position checklist
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Confer on plant events with JNC Director, JNC Technical Advisor and others present, or establish contact with the EOF directly if not done yet
- Obtain update on plant activity from JNC Technical Advisor/EOF Information Liaison/Emergency Director
- Initial Preparation:Begin formulating communications strategy and priorities (along with JNC Director, if present), and determine graphics that may be needed during Media Briefings from the graphics inventory list (located at your work station, or in the Emergency Communications Guide) and inform Media Room Manager to begin arrangements with the Audiovisual Coordinator JNC Operational Activities 2.0 Ongoing Responsibilities
- Review plant status reports, information sheets, state and county news releases, EAS messages and other information as it becomes available
- Confer with JNC Director and coordinate on Media Briefing points, key messages, outstanding information requests and needed clarifications, and other communications points, as appropriate; JNC Technical Advisor can also provide support 3.0 Written statements
- Review, provide directions and input to the JNC Writer and approve all Written Statements generated at the JNC, gaining concurrence or confirmation from the Emergency Director. As necessary, request the JNC Director and/or JNC Technical Advisor review written statements and provide comments Page 29 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 4 Company Spokesperson Checklist Sheet 2 of 4 4.0 Pre-Briefings Notes
- Define information to be presented at Media Briefing (see Media Briefing Content Guides below and in position binder), obtain JNC Director and other staff support
- Use available reference materials including, Emergency Classification Level Explanations, Radiation Comparisons, System and Component Terms and Definitions, Booklet and Maps, and other information available in the Emergency Communications Guide and in the Utility work room A bookcases.
- Review, select and request Graphics and other visual aids from Audiovisual Coordinator (can be done via Media Room Manager) in preparation, referring to the Emergency Communications Guide and other available references,
- Review Media Briefing information with JNC Director prior to pre-briefings
- Prior to Media Briefings the Media Room Manager conducts a pre-briefing. Provide utility information with state and counties, resolve inconsistencies, address concerns, establish briefing protocol and set the order of speakers. (Public safety and protective action information will take priority). Agency Liaison arranges logistics for all pre-briefing meetings.
- Take the lead in briefing state and counties on plant/event information. Obtain information on state, county efforts as needed. When complete, proceed to Media Briefing Room to conduct briefing 5.0 Media Briefings
- When: Media Briefings are called by the State, County or Entergy as significant events occur or critical information becomes available. JNC Media Briefings usually follow classification changes, major events or significant actions by Entergy, state or counties within 60 minutes. Coordinate with the JNC Director on establishing the Media Briefing times
- Content Compile media briefing notes and messages using the JNC Briefing Notes Guide, Form IP-1011-8. Each briefing should focus on three areas of information:
what happened, what we're doing about it, and what it means (see Media Briefing Content Guide below and other available reference materials, including Media Briefing Communications Tips from Emergency Communications Guide).
- In preparing notes for briefings, ensure unanswered questions, inconsistencies and inaccuracies identified in previous briefings are noted.
- Provide copy of Talking Points to JNC Writer before departing for Pre-Briefings to facilitate development of Media Briefing Summaries
- Briefing Format:The Media Room Manager opens Media Briefings by making introductory remarks and establishing the process and ground rules. Audiovisual Coordinator and AV/Graphics Staff will connect wireless microphone and set up all audiovisual equipment in advance. Wait for introduction by Media Room Manager before initiating briefing. Conduct briefing using prepared Media Briefing Notes and visuals. Respond to questions as directed by Media Room Manager.
Page 30 of 91
JP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 4 Company Spokesperson Checklist Sheet 3 of 4 6.0 Post-Briefings Notes Upon return to Utility Room A, receive feedback on briefing. Obtain plant update from JNC Director and JNC Technical Advisor. Review open items and other issues from briefing, and determine appropriate actions to complete follow-up 7.0 Post Event
- Participate in debriefing and return work area to start up condition. Provide documentation and materials to JNC Director Page 31 of 91
II IP2 '-1 011, Joint News Center, Rev. 6 lP3 JNC Operations Manual Attachment 4 Company Spokesperson Checklist Sheet 4 of 4 Media Briefing Content Guide Briefing #__
Briefing time/date:_
WHAT Happened? What are we DOING about it?
[Include inthis section information about events causing the [include here the actions being taken to deal with the emergency declaration, major equipment problems, injuries emergency, including ERO activation, repairs to to personnel, radiological releases, etc.] equipment, engagement of offsite support, and radiation surveys]
What does it MEAN??
[Discuss here the Implications of the emergency, including effectiveness of protective measures, recovery expectations Page 32 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 5 JNC Technical Advisor Checklist Sheet 1 of 2 Primary Responsibilities Reporting to JNC Director, establish and maintain contact/information exchange with the EOF (via EOF Information Liaison); provide technical expertise to support understanding of events; advise Company Spokesperson and JNC Director on plant events; support development/review of written statement technical accuracy; and as time permits, monitor Media Briefincgs to document issues and unanswered questions.
Mobilization and Activation Activities Notes 1.0 On arrival at JNC U
Register in lobby and sign Utility Sign-In board in hallway by Utility Room A U If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Report to Utility Room A and refer to position checklist, and establish contact with the EOF using the direct line (contact the EOF Information Liaison),
establish official time from the EOF and advise the JNC Director JNC Operational Activities 2.0 Ongoing Responsibilities Review plant status reports electronically, by fax and online (30 Alpha forms, Radiological Emergency Data forms parts 1, 2), UEOF to JNC Essential Information Checklist" (Form IP-1011-1), written statements, and other information on events and response actions as it becomes available and advise Company Spokesperson and JNC Director as appropriate
- Gather information as required to support Company Spokesperson and JNC Writer to develop materials for dissemination (refer to Information Gathering Checklist below for guidance)
GATHERING INFORMATION CHECKLIST
- 1. What was the event - system, component, consequence?
- a. Plant status or potential to effect plant status?
- b. Release of radiation or potential for release?
- c. Injuries/contamination?
- d. Leakage or spills?
- e. Toxic/hazardous material?
- f. Safety significance?
- 2. When did it happen - specific time, has it ended?
- 3. Why did it happen - equipment failure, weather conditions, etc?
- 4. What is being done - to respond, repair, mitigate or prevent it from happening again?
- 5. Who was involved/responsible - potential information sources?
- Establish contact with EOF Information Liaison to obtain updated information both verbally and electronically using "EOF to JNC Essential Information Checklist" via email and in position binder. Print and provide forms to Administrative Manager for further distribution Page 33 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 5 JNC Technical Advisor Checklist Sheet 2 of 2 JNC Ooerational Activities, (cont'd) Notes
- Request information from the EOF Information Liaison, and as necessary use available references as needed, including Emergency Action Level Guide, glossary of technical terms, technical plant references in JNC, and computer with access to plant parameters
- Log events and information provided from the plant on a running plant status log (flip chart) in the utility workroom. Request assistance from the Administrative Manager if administrative assistance is required to accomplish this function.
3.0 Written Statements a Provide new information and needed descriptions to the JNC Writer to support written statement development efforts
- Review and provide technical comments on statements as needed with JNC Writer 4.0 Pre-Briefings
- Advise Company Spokesperson and JNC Director on plant events
- Assist Company Spokesperson in preparing Media Briefing notes as needed 5.0 Media Briefings
- Support Company Spokesperson to obtain needed information to answer questions and open issues from Media Briefings
- Monitor Media Briefings, time permitting, from Utility Room A and complete Media Briefing Issues forms (Form IP-1011-2, Addendum 4) if any open issues or follow-up requests are identified. Provide completed forms to JNC Director after briefings.
- After Media Briefings, promptly update spokesperson on events and status changes during the briefing 6.0 Post Event a Participate in debriefing and then return work area to startup condition before departing facility Page 34 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 6 Technical Briefer Checklist Sheet 1 of 1 Primary Responsibilities Reporting to Media Room Manager, serve as information source to the media by providing technical background information on plant operations and equipment as needed Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A
- Report to Media Room Manager in Media Briefing Room - Refer to position checklist located in AV Control Room behind stage
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
JNC Operational Activities Notes 2.0 Ongoing Responsibilities
- Remain in Media Briefing Room to provide the media with technical background information on plant operations between briefings. Do not elaborate on plant conditions, speculate, or render personal opinions
- Ensure Media Room Manager or Media Room Liaison is available during interaction with media between briefings, and ensure cameras are not rolling during background discussions
- If necessary, defer technical background questions if additional information or research is necessary. Request support from the Media Room Manager, contact the JNC Technical Advisor directly and/or go to the Utility Room A for reference and research information
- Relay information to Media Room Manager on reporters' questions as feedback to Utility Room A for use in preparing next Media Briefing 3.0 Media Briefings
- Monitor briefings for accuracy by Company Spokesperson using Media Briefing Issues form, Addendum 4 (Form IP-1011-2) and relay comments to Media Room Manager 4.0 Post Event
- Participate in debriefing and then return work area to startup condition before departing facility Page 35 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 7 Administrative Manager Checklist Sheet 1 of 4 Primary Responsibilities Reporting to the JNC Director, supervise all JNC administrative activities, functions and personnel (registration, administrative support, security, IT support), and coordinate auxiliary services, if necessary (maintenance, food, lodging). supervise JNC facility deactivation and ensure facility is fully operational after each use. Coordinate facility support as required with state, county and federal representatives.
Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-in board outside Utility Room A
- Report to Utility Room A and refer to position checklist
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway. Assign additional personnel as needed until Registration Coordinator and Security staff have arrived
- Verify completion of JNC Staffing by reviewing sign-in/staffing forms from Registration Coordinator(s), (Addendum 5, Form IP-1 01 1-3) and review the JNC Utility Sign-In board located outside of Utility Room A; complete the Sign-in board if names of available staff are not included
- Confer with JNC Director to determine no-shows, instruct Registration Coordinator or other designated staff to fill positions with alternates if necessary (Refer to Emergency Telephone Directory if necessary to make contacts).
- If security is not present, contact Security Shift Supervisor to confirm they are reporting. (Coordinate this with the JNC Director)
- Assign available Administrative Support Staff to required support areas including JNC Documenter position, Fax/Copy area, distribution, runner and other support functions, as needed, and direct set up and then ongoing support activities (A partial equipment list is contained below, and a full listing is available in the "Administrative Quick Reference Manual" located in Utility Room A).
- Oversee JNC set-up, including heat or air conditioning, lights, copiers, food service. Receive official time from JNC Director and direct the IT Representative and Administrative staff to synchronize clocks, fax machines, time stamp, etc.
Detailed procedures are available in Administrative Quick Reference Manual" located in Utility Room A
- Contact fax and copy machine contacts and have them send support staff to JNC (refer to 'Administrative Quick Reference Manual" located in Utility Room A)
- Contact Maintenance Support Contractor and ask for maintenance support at JNC (Refer to "Administrative Quick Reference Manual" located in Utility Room A)
- Ensure administrative staff establish and maintain a log for incoming and outgoing faxes Page 36 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 7 Administrative Manager Checklist Sheet 2 of 4 JNC Operational Activities Notes 2.0 Ongoing Responsibilities Working with JNC Director and Registration Coordinator, make shift assignments; (Form IP-1011-3); Release any individuals not currently filling a position on the 1t shift who initially responded to the JNC, after assigning them to second shift
- When all positions are filled and shift assignments have been made, provide completed shift roster to JNC Director for provision to Emergency Director; Ensure faxing of the form to the EOF, if requested to do so
- Supervise all Administrative Support Staff including those in the Fax/Copy area, JNC Documenter, distribution, status sheet posting for the JNC Technical Advisor, Security and Registration Staff
- Assign responsibility and supervise distribution of plant status reports, forms and EOF to JNC Essential Information Checklists provided from JNC Technical Advisor by Administrative Support Staff to:
- JNC Director
- JNC Technical Advisor (iforiginal is only copy, provide a copy before continuing duplication and distribution to others)
- Company Spokesperson
- Radiological Advisor, if present
- JNC Documenter
- JNC Writer
- Supervise Security personnel, and coordinate on access or other security issues, as needed
- Maintain JNC in operational condition during its use. Oversee and direct facility operations to ensure smooth functioning of equipment and the facility itself
- Arrange food service (refer to "Administrative Quick Reference Manual' located in Utility Room A for options)
- Arrange for water for dais in Media Briefing Room
- Arrange for first aid or emergency care if required
- Make emergency overnight sleeping accommodations, if necessary (portable cots available in Entergy storage room, or make appropriate contacts, see "Administrative Quick Reference Manual" located in Utility Room A for options)
- Provide attendance sheets to Documenter for each shift for permanent log keeping Page 37 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 7 Administrative Manager Checklist Sheet 3 of 4 JNC Operational Activities (cont'd) Notes 3.0 Written Statements
- Supervise proper approval sign-off by Company Spokesperson on final written statements (ensure appropriate signatures and times noted- stamp final news release on back for signature)
- Direct Administrative Support personnel to copy written statement and provide to Agency Liaison for simultaneous acknowledgment and distribution to State, Counties and federal representatives present, and provide copy to Fax
- Counties and federal representatives present, and provide copy to Fax/Copy area staff to make remaining copies for distribution within JNC and for faxing.
- Oversee distribution of Written Statements, including use and completion of Written Statement Distribution Checklist (Form IP-1011-5)
- Establish/Confirm required fax recipients with JNC Director, prepare Fax Distribution Sheet (Form IP-101 1-7) noting desired recipients (including media, EOF and other Entergy locations) and supervise distribution of final Entergy written statements by Administrative Support Staff to those designated.
Additionally, broader distribution may also be required or requested by Entergy, the State or Counties. (Fax numbers are pre-programmed in the Panafax for these recipients) 4.0 Post Event
- Participate in debriefing and then return work area to startup condition before departing facility
- Oversee facility deactivation including ensuring all documentation and completed checklists, logs, etc. are gathered and provided to the JNC Documenter, as per procedures posted in Utility Room A
- Ensure facility is operational for next use Page 38 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 7 Administrative Manager Checklist Sheet 4 of 4 JNC Equipment List The following equipment is provided for use at the JNC:
E TV Camera E Lights 0 Camera tripod with tripod head O Power belts E Battery Charger E TV Carts O Microphone E Shotgun microphone O Power module for shotgun microphone E TV camera lens -- 1/10 zoom 0 35 mm slide projectors E Video player/recorder -- 3/4" E Off air video recorder - 1/2" 0 19" color TV receivers E 12" color video monitor E AM/FM radios with recorders E Antenna UHF/NHF/AM/FM O Distribution amplifiers 0 Remote speakers 0 13" color monitors E Multi box with public address and recorder E Storage cabinets E Schematic of the Indian Point system 0 1/2" portable video recording outfit E Copy machines E Computer and printers E Fax machines E Telephones Page 39 of 91
IP2 IP-1011, Joint News Center, Rev. 6 I133 JNC Operations Manual Attachment 8 JNC Writer Checklist Sheet 1 of 4 Primary Responsibilities Under the overall direction of the JNC Director with additional direction from the Company Spokesperson, prepare written statements within one hour of a new Emergency Classification or when plant events warrant public notification, and media briefing summaries following each Media Briefing; submit draft statements for review by Company Spokesperson and/or JNC Technical Advisor; work with the JNC Technical Advisor or Company Spokesperson to ensure technical concurrence is obtained from the Emergency Director; make changes as directed, number, date and print final/approved statements and provide to Administrative Manager for sign-off and distribution Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Report to Utility Room A and refer to position checklist JNC Operational Activities 2.0 Ongoing Responsibilities
- Turn on PC and monitor
- On main screen, select and open appropriate folder for use (Source documents are Read Only documents)
- Test word processing program and printer
- Locate INDIAN POINT Boiler Plate News Release files/folder on the computer, or CD available in position binder
- Create new file folder for event and label with event date
- Receive plant status and emergency response updates from JNC Technical Advisor
- Request that the JNC Technical Advisor determine the status of ongoing communications response via the EOF Information Liaison, and obtain the name and contact information of the responding IP Communications Representative
- Establish direct contact with the IP Communications Representative to establish the status of written statements and to coordinate a hand-off when the JNC is ready to activate.
- Copy (Save As) appropriate EAL boiler plate news release and place in folder -
edit and modify with available and appropriate information, as necessary
- Ensure all unnecessary information in sample boilerplate is removed. Add pertinent information at the direction of the JNC Technical Advisor or Company Spokesperson
- Use Emergency Communication Guide for additional background and source information Page 40 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 8 JNC Writer Checklist Sheet 2 of 4 3.0 Written Statements Notes When: Written Statements should be made as soon as possible, but within one hour of:
- 1. Initial plant emergency declaration (made before JNC becomes activated)
- 2. JNC activation (announcing activation)
- 3. A new Emergency Classification (escalation)
- 4. When plant events warrant public notification, such as
- A fatality or serious injury,
- Release of radioactivity beyond the site boundary, in quantities
- exceeding those allowed by regulation, or
- Personnel exposures to radiation exceeding limits allowed by
- Regulation
- 5. Emergency event termination,
- Media Briefing summaries should be developed following Media Briefings to summarize the information provided by the Company Spokesperson.
- Other written statements may be issued at the discretion of the Company Spokesperson or JNC Director, including chronologies on an infrequent basis
- With support from JNC Director, Company Spokesperson and JNC Technical Advisor, prepare written statement drafts using sample boiler plates and standard phraseology combined with information provided by EOF as appropriate; When using sample boiler plate review all wording for accuracy and applicability
- Use Written Statement Content Checklist (see below) and if needed the suggested phraseology, Emergency Action Level descriptions and other reference information contained in the Emergency Communications Guide to prepare these drafts. News Release Template instructions are also provided on the CD with the boilerplate news releases.
- Print draft statement without date or time for review by JNC Technical Advisor first, and then by the Company Spokesperson. The JNC Director should also review statements for communications messages and to provide input
- Make changes to draft statements, based on reviews, as directed by Company Spokesperson, JNC Technical Advisor and/or JNC Director
- Once all feedback is incorporated and Company Spokesperson indicates it is ready, coordinate with the JNC Technical Advisor to electronically forward the final draft to the EOF for ED review and concurrence. Incorporate comments, as directed by the Company Spokesperson and/or JNC Director.
- Add the time ONLY upon approval from the Company Spokesperson, and print final approved written statement for distribution, Page 41 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 8 JNC Writer Checklist Sheet 3 of 4
- Written statements (cont'd) Notes
- Give final statement to Administrative Manager for approval signature and distribution sign-off
- Prepare drafts and final copies of subsequent written statements as described above
- Ensure all statements are placed in appropriate computer folder with current date and saved on the C Drive 3.0 Media Briefings
- Receive Company Spokesperson's Talking Points before Media Briefing, and observe/listen to Media Briefings. Make note of information for inclusion in follow-on Media Briefing Summary
- Immediately after each Media Briefing, complete a draft summary statement of the information presented by Company Spokesperson.
- The summary should be concise (two-to-three pages maximum).
- The first paragraph identifies the time and number of the briefing, the event and the Company Spokesperson and title.
- The target for a completed draft, ready for review, should be about 30 minutes after the end of the briefing.
- Provide drafts to the Company Spokesperson and JNC Technical Advisor for prompt review to confirm completeness and accuracy.
- Coordinate the review by the Emergency Director for concurrence 4.0 Post Event
- Participate in debriefing and then return work area to startup condition before departing facility Page 42 of 91
IP2 IP-1011, Joint News Center, Rev. 6 1P3 JNC Operations Manual Attachment 8 JNC Writer Checklist Sheet 4 of 4 Written Statement Content Considerations The following information should be considered for inclusion, as applicable:
Reference Information:
- Indian Point, Buchanan, NY
- Time and date of written statement
- Contact for further information (name, title, phone number)
What Happened:
- Emergency description - description of the event, systems or components involved, etc.
Time and date of the event Emergency classification, with brief description of its meaning
- Emergency Action Level (EAL), with brief description of its meaning
- Injuries to personnel, if any
- Radiological releases, if any Emergency Response - What's Being Done:
- Emergency Response Organization mobilized
- Notification of off-site officials (NRC, Counties and State, FEMA, etc.
- In-plant actions to correct or mitigate the situation, repair equipment, etc.
- Support from off-site organizations
- Off-site radiological monitoring activities Implications - What it Means:
- Current plant condition, stability
- Anticipated resolution (e.g., reactor shutdown and cool-down by [time].
- Termination of any releases
- Measured off-site radiation levels
- Off-site protective actions (refer to state authorities)
Notes:
- 1. After the initial news release, subsequent releases should not repeat all of the details previously covered; in composite, however, the releases should give a complete picture
- 2. The checklist above provides suggested content; release writers use judgment with respect to content and sequence of information.
Page 43 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 9 Agency Liaison Checklist Sheet 1 of 2 Primary Responsibilities Under the direction of the JNC Director, serve as information liaison with government officials and state and county public information officers (PlOs); continue courtesy calls after JNC activation to local officials, to keep them informed of changing classifications, events; coordinate pre-briefing and Media Briefing times among the utility, state and county (and federal if present) representatives; notify absent PlOs of pending written statements prior to release and of pre-briefing times prior to conducting Media Briefing; ensure all state and county PlOs acknowledge and sign off on written statements; support pre-briefings (including contacting absent PlOs; if necessary).
Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-in board outside Utility Room A
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Report to Utility Room B and refer to position checklist
- Establish contact with State and County Room PlOs, and monitor/maintain State/County Sign-in Status Board outside Utility Room A. Update JNC Director on who is present in the JNC
- Confirm ability to establish EAS messages through Westchester County Pl or Westchester Emergency Operations Center (EOC) if PIO is not present at JNC, and inform JNC Director once confirmed to facilitate JNC activation
- Prior to arrival of NY State Liaison, coordinate responsibility with Administrative Manager to monitor PIO emergency conference phone in Pre-Briefing Room; Keep log of any incoming or outgoing calls made 2.0 Ongoing Responsibilities
- Review, EOF to JNC Essential Information Checklist, written statements, and other information as it becomes available
- Update status boards in all JNC Rooms, announce status change and ring bell; Ensure staff acknowledges Emergency Classification change status (remove posted Emergency Summary Sheets, if no longer applicable or outdated, as updating JNC rooms)
- Using primarily EOF to JNC Essential Information forms, complete and update the Emergency Summary Sheet (Form IP-1011-4), copy and distribute to workrooms (state, county, and federal only) and to the JNC Documenter
- Maintain log of all incoming/outgoing calls from emergency conference phone (located in pre-briefing area) during Event prior to State PIO arrival. This phone is to be used to establish contact with State and/or County PlOs that are not present.
- Continue courtesy calls to Buchanan, Cortland and Peekskill local officials (numbers in Emergency Telephone Directory) to ensure they remain informed of activities, if still required. Coordinate with IP Government Liaison on status.
Page 44 of 91
1P2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 9 Agency Liaison Checklist Sheet 2 of 2 JNC Operational Activities Notes 3.0 Written Statements/EAS Messages EAS Messages: Acknowledge receipt of Emergency Alert System (EAS) messages issued at JNC by initialing documents (Coordinate with Westchester County and/or State as EAS messages are being developed, and at issuance to ensure prompt sharing of this information throughout the JNC
- Provide a copy of all EAS messages to the Administrative Manager for prompt distribution. Notify the JNC Director of the planned timing of EAS broadcasts
- Government News Releases: Acknowledge receipt of government agencies (NRC, FEMA, State and County) news releases by initialing and provide to Administrative Manager for prompt distribution
- Entergy Written Statements: Ensure that all state and county PlO's acknowledge Entergy written statements prior to release to wire services and the news media present (except JNC activation media advisory, no acknowledgments are required)
- Utilize PlO emergency conference phone to contact and inform absent PlO's of impending issuance of written statements (refer to Addendum 7 Written Statement Distribution Checklist, Form IP-1 011-5).
- Any final news releases approved and distributed PRIOR to JNC activation will be faxed to the JNC. Distribution should occur within the facility as normal, but no acknowledgments or sign-offs are required.
- Provide a copy of issued Entergy written statements to State and County representatives/workrooms at same time as obtaining acknowledgment, if copies are ready (Coordinate with Administrative Manager and Administrative Support Staff.)
4.0 Pre-Briefing
- When: Prior to Media Briefings
- In absence of state PIO, help coordinate among Company Spokesperson, Media Room Manager, state and county representatives planned information for release, resolve inconsistencies, address concerns, establish briefing protocol and set the order of speakers (public safety and protective actions take priority)
- Arrange all Pre-Briefings at request of JNC Director and coordinate with state and county PlOs on time of pre-briefing
- At request of JNC Director, ensure Media Room Manager is notified in Media Briefing Room of scheduled pre-briefings and media briefing times
- Attend Pre-Briefing; contact absent state and county PlO's using PIO emergency conference phone in Pre-Briefing Room; notify absentees of pending media briefing information 5.0 Post Event
- Participate in debriefing and then return work area to startup condition before departing facility Page 45 of 91
IP2 IP-lO1l, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 10 Media Room Manager Checklist Sheet 1 of 7 Primary Responsibilities Reporting to JNC Director, acts as the primary interface for media present at JNC; acts as moderator for media briefings; supervises audio-visual staff in JNC and prepares press kits for media Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Go through registration, sign in on Sign-In Board outside of Utility Room A, report to Utility Room A for event status, then proceed to Media Briefing Room
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Ensure Media Room Liaison prepares and sets out Media Kits and emergency Planning booklets located in storage room on first floor
- Ensure Media Room Liaison checks all news release folders to ensure they are empty, or only contain current news releases (IF news releases have been issued THEN place copies in folders)
- Check status boards and PlO sign-in board for PlOs present in JNC and on dais for accuracy
- See Technical Briefer and Radiological Health Expert to their posts
- Ensure Security keeps the media in media work areas while Media Briefing Room is set up for initial briefing (News media should not be permitted to enter Media Briefing Room until completely set up; Work with Security staff if needed) Keep Media Briefing Room doors locked until in startup condition JNC Operational Activities Notes 3.0 Ongoing Responsibilities
- Identify and welcome media representatives at the JNC
- Brief the Company Spokesperson and/or JNC Director on the media present at the JNC and their information needs
- Act as senior liaison to the media regarding process for gathering information, explain JNC process
- Interact with the news media at the JNC to determine and respond to their need for background information and support services, and ensure the Media Room Liaison does so as well
- Receive special media requests or needs from Media Room Liaison for resolution
- Confine comments to media about plant/event to information contained in news releases Page 46 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 10 Media Room Manager Checklist Sheet 2 of 7 3.0 Media Briefings Notes
- Receive notification from the Agency Liaison (or JNC Director) of Media Briefing times, and make timely announcements to the media present In the JNC (announce briefings will take place at approximately' the time given) -
- Announce information on Media Briefing process to media prior to and following media briefings (see Announcement Guides below)
- Prior to Media Briefings conduct a pre-briefing using the Media Briefing Worksheet (see below). Ensure Company Spokesperson provides utility information with state and counties, resolve inconsistencies, address concems, establish briefing protocol and set the order of speakers. (Public safety and protective action information will take priority). Ensure Agency Liaison has arranged logistics for all pre-briefing meetings. Obtain background or bios on each spokesperson for use, if necessary (and provide an written documents to the Media Room Liaison to put into Media Kits)
- Ensure all AV/Graphics needs of Company Spokesperson and other PlOs are taken care of prior to start of Media Briefings. Some requests may be given during pre-briefings. Ensure the AV Coordinator or Media Room Liaison is set to support microphone use for Q&A by the media.
- Briefing Format: Open Media Briefing by making introductory remarks; -Serve as moderator; Introduce spokespeople to make agreed upon statements in pre-established order
- In each briefing, Ensure to conclude each briefing with the following Public Inquiry announcement: To assist the public with receiving clarification on information that may be in conflict with official announcements, the public may call" (see Announcement Guides below)
- Preside over &A session, repeating questions as needed and directing them to appropriate spokesperson
- Maintain order throughout. At times, media briefings can become contentious. It is the moderator's responsibility to defuse arguments, to intercept hostile comments, and to ensure that the briefing is held in an informative, professional way.
- Conclude the Media Briefing when appropriate, ensuring the sessions do not go too long, and allowing the spokespeople to return to their work areas for updating of information. Ensure a time is announced for the next Media Briefing, ideally within an hour of the conclusion time, or longer depending on the status of events.
Media Briefings may also be announced in a sooner timeframe, if the situation and/or information changes) 4.0 Post-Briefing
- Monitor interaction between media and experts; intervene if necessary
- Ensure a videotape copy of the previous briefing is available for viewing in the media work room, in coordination with the Audiovisual Coordinator 5.0 Post Event
- Participate in debriefing and then return work area to startup condition before departing facility I1 Page 47 of 91
IP2 IP-1011, Joint News Center, Rev. 6 1P3 JNC Operations Manual Attachment 10 Media Room Manager Checklist Sheet 3 of 7 Media Room Announcement Guides At the first news briefing, the following announcement will be made by the moderator of the PlO panel:
TO ASSIST THE PUBLIC IN OBTAINING CLARIFICATION ON INFORMATION THAT MAY SEEM TO BE IN CONFLICT WITH OFFICIAL ANNOUNCMENTS, MEMBERS OF THE PUBLIC MAY CALL:
(914) 683-6499 THE PUBLIC MAY CALL THIS NUMBER FOR CLARIFICATION OF INFORMATION CARRIED INTHE MEDIA OR CIRCULATING IN THE COMMUNITY THAT SEEMS TO CONFLICT WITH THE OFFICIAL INFORMATION COMMUNICATED EITHER BY THE EMERGENCY ALERT SYSTEM (EAS)
OR BY THE NEWS MEDIA.
AGAIN, THE NUMBER FOR THE GENERAL PUBLIC TO CALL IS:
(91 4)-.683-6499 Page 48 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 10 Media Room Manager Checklist Sheet 4 of 7 Media Room Announcement Guides The following is suggested wording for announcements made by the Media Room Manager:
- 1. Periodic Announcement:
Good morning/aftemoon/evening. Thank you for coming to the Joint News Center. I am [name].
As Media Room Liaison, I am here to assist you with your information needs between official media briefings.
First, some background on this facility and the resources available to help you report on the events at Indian Point (2/3) Nuclear Power Plant:
The Joint News center is the sole source of information for the media. Our company spokesperson is here, along with representatives from New York State and the four counties that surround the plant [MAKE SURE YOU HAVE THE NAMES OF ALL THE PlO'S PRESENT] -
Westchester, which is the lead county, and Rockland, Orange and Putnam Counties.
During the briefings, Entergy will report on events at the plant. The state and counties will report on their actions to protect the public. The Emergency Alert System messages are prepared and issued from this location. They are for broadcast over WABC Radio in New York City and by other radio stations in the areas surrounding the plant.
To help you report to the public on Indian Point events, we have provided some background information and technical assistance. To the table on my left are copies of news releases prepared by the utilities, counties and state. There are press kits with background information on the plant as well as a floor plan of the Joint News Center. There are also copies of the Emergency Planning brochures that are mailed annually to each residence in the 10-mile zone around the plant. They contain useful graphics of the emergency planning zones. Across the hall on this floor are rooms with telephones for your use.
On the right side of the room are the subject matter expert(s) available to help you between briefings. [Confirm that Dr. Ryan and/orMs. Stanton are present, before making this announcement.]Dr. Robert Ryan, Professor of Engineering at Rensellaer Polytechnic Institute, and Ms. Cathy Stanton, of Catherine C. Stanton & Associates, Inc. - a consulting firm in Nuclear Technology. Neither Dr. Ryan nor Ms. Stanton is a spokesperson. They are here to provide you with background information only.
In addition to the floor plans in the media kits, Joint News Center areas are well marked with signage. There is a wheelchair lift in approximately the center of the building. There are restrooms on this level down the hall to my right including one with handicapped access. There is a men's room is on the first floor at the rear of the cafeteria.
I am here to assist you, so please feel free to bring me your questions and information needs.
The next briefing will be in approximately [time period.
Page 49 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 10 Media Room Manager Checklist Sheet 5 of 7 Media Room Announcement Guides
- 2. Additional Media Room Manager announcement, following each briefing:
Our spokespeople will be back for further briefings as conditions and events dictate. Again, I am here to assist you. Ifyou have other questions, I will submit them for a response at the next briefing.
Page 50 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 10 Media Room Manager Checklist Sheet 6 of 7 JNC Moderator's Briefing Introduction Guide The following is suggested introductory remarks by the Media Room Manager, in his or her role as Media Briefing Moderator. A condensed version may be appropriate over time.
Topic Suggested Wording
- 1. Announcement 'This is a Drill' (or "This is NOT a drill")
- 2. Introduce yourself "My name is [name]. I am serving today as the Joint News Center Media Room Manager. I am an Entergy employee and a member of the plant staff; my regular position is Ititle]."
- 3. Explain purpose of the "Our objective this morning is to provide a thorough briefing about this briefing event - what happened today, what we're doing about it and what it means."
- 4. Explain the role of the JNC 'The Joint News Center is the sole source of information on events at Indian Point (2/3). Events like today's can be complex and fast-moving.
Our staff in this building is in constant communication with those in the plant who are managing the emergency response; we're working hard to assemble as complete, accurate and timely a picture as practical about the today's event."
- 5. Introduce the participants 'With us today are:
and their roles
- [name and title), Entergy. He/she will provide a detailed explanation of what's going on in the plant.
- [name], Public Information Officer, Westchester County
- [name], Public Information Officer, Rockland County
- [name], Public Information Officer, Orange County
- [name], Public Information Officer, Putnam County
- [name], Spokesman for the New York State Disaster Preparedness Commission
'We at Entergy are responsible for running the plant and for managing the in-plant response to emergency events. Authorities from the state and county, represented here, are responsible for deciding upon and implementing any protective actions for the public."
Page 51 of 91
IP2 IP-1011, Joint News Center, Rev. 6 1P3 JNC Operations Manual Attachment 10 Media Room Manager Checklist Sheet 7 of 7 JNC Moderator's Briefing Introduction Guide (continued)
- 6. Set the format "We'll begin with ..... (Note: include order per prior agreement) either,
... a detailed explanation by [name], of the event, the actions Indian Point has taken, and other plans and status".
"...the State of New York /Westchester County/other to summarize the state/county's actions.
'After these briefings, we will take questions. Please hold your questions until that time."
- 7. Briefing(s) "At this point, [name] will brief us on today's events."
- 8. Q&A "Thank you. We'll be happy to try to answer any of your questions. I will serve as moderator, please address your questions to me, and I will refer. Please first state your name and your affiliation, and then ask your question."
- 9. Close "Thank you. If you would like copies of our news releases, the graphics used for today's briefing or. other background material, please see
[name], at the side table.
"Also, please note that we have set up a Public Inquiry Service, for clarification of any information circulating in the community that may appear to be in conflict with the information we've officially disseminated. Members of the public may call Public Inquiry directly at 914-683-6499. Our representatives are standing by. Again, the public Inquiry number is 914-683-6499."
Page 52 of 91
IP2 P-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 11 Media Room Liaison Checklist Sheet 1 of 1 Primary Responsibilities Reporting to Media Room Manager, act as the interface for media present at JNC; identify and arrange for media needs, as appropriate; support audio-visual staff in JNC as needed, and prepares media kits for media Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Go through registration, sign in on Sign-In Board outside of Utility Room A, report to Utility Room A for event status, then proceed to Media Briefing Room
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Prepare if needed, and set out Media Kits and Emergency Planning booklets located in storage room on first floor
- Check all news release folders to ensure they are empty, or only contain current news releases (IF news releases have been issued THEN place copies in folders)
JNC Operational Activities 3.0 Ongoing Responsibilities
- Act as liaison to the media regarding process for gathering information, explain news release folders and ensure more recent news releases are contained
- Interact with the news media at the JNC to determine and respond to their need for background information and support services.
- Do NOT comment on the emergency or provide opinions or explanations
- Ensure the availability of news releases, written statements, Emergency Alert System messages, media kits and other materials
- Provide assistance by advising reporters of past media briefings, showing them their work areas and distributing copies of available information
- Facilitate the use of the Technical Briefer and Radiological Health Expert by the media, enforcing the ground rules for obtaining background information. Remain present during discussions to ensure no cameras or microphones are used to include statements. These individuals are NOT spokespersons.
3.0 Media Briefings
- Ensure all AV/Graphics needs of Company Spokesperson and other PlOs are taken care of prior to start of Media Briefings. Some requests may be given during pre-briefings, and conveyed via the Media Room Manager. Use the Emergency Log in your position binder to document requests from the media.
- Support Media Briefings, as requested by the Media Room Manager, by controlling the microphone on the floor to capture questions by the media.
Remain in control of the microphone at all times.
- Provide ongoing support of media before, during and after Media Briefings, and provide special requests or needs to Media Room Manager for resolution 5.0 Post Event
- Participate in debriefing and then return work area to startup condition before departing facility Page 53 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 12 Audiovisual Coordinator Checklist Sheet 1 of 1 Primary Responsibilities Reporting to the Media Room Manager, perform all audiovisual tasks (set-up, test, operate, prepare graphics) for media briefings Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A and refer to position checklist
- If among the first-to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Work with AV/Graphics Staff to
- Check all audio visual equipment in the JNC to be sure it is ready to record, tape and play back. Test and ensure all TV monitors are functioning in Utility Rooms A & B, State and County Rooms, EAS, FEMA, NRC, Media Monitoring Room, Media Rooms and Public Inquiry Room
- Set-up and test microphones, wireless microphone and sound systein in Media Briefing Room,
- Set up computer and projection equipment for use to support graphics and visual requirements (Refer to AV Equipment Instructions manual in AV Control Room)
- Work with Media Room Manager to establish schematics/graphs/slides requirements for Company Spokesperson, and prepare for Media Briefings JNC Operational Activities Notes 2.0 Media Briefings
- Perform and/or delegate the following tasks:
- Wireless microphone for Company Spokesperson
- Arrange power point presentation and other visuals for Company Spokesperson as needed
- Record and videotape Media Briefing
- Coordinate staff to handle wireless microphone for &A - do not give microphone to individual asking question
- Prepare tapes for playback 3.0 Post Event
- Participate in debriefing and then return work area to startup condition before departing facility Page 54 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 13 AV/Graphics Staff Checklist Sheet 1 of 3 Primary Responsibilities Reporting to the Audiovisual Coordinator, perform all audiovisual tasks (set-up, test, operate, prepare audiovisual equipment) and provide Graphic Arts support for Media Briefings Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A and refer to position checklist
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Set up and check all audiovisual and computer equipment to be sure it is ready to record, broadcast, tape, play back and/or project. Test and ensure all TV monitors are functioning in Utility Rooms A & B, State and County Rooms, EAS, FEMA, NRC, Media Monitoring Room, Media Rooms and Public Inquiry Room
- Refer to the AV Equipment Instructions manual in the AV Control Room (and/or the power on password for the PC on the stage in (Edisonl or Entergyl). Anyone who has an account on the Con Ed (P2) domain can log into the machine using their username and password OR use any of the generic log ons from EP1 through EP8 and the password for each generic log on is password
- Most graphics for both P2 and P3 are located on the hard drive, in powerpoint.
Some graphics/photography are located on \\Midyat2\Public\JNC Pictures
- Refer to Media Briefing Room Reference Listing (below)
- Provide technical assistance for media monitoring equipment as needed in Media Monitoring Area
- In Media Briefing Room, set-up and test microphones, wireless microphone and sound system. Set up transparency and/or projection system for briefings.
- Work with Media Room Manager to establish needs for schematics/graphs/slides selected by Company Spokesperson for use during Media Briefings. Place plant diagram on easel at right of podium and have other drawings ready.
- Remind Company Spokesperson and/or Media Room Manager of graphics and system drawing book available in Work Room A Page 55 of 91
IP2 IP-1011, Joint News Center, Rev. 6 1P3 JNC Operations Manual Attachment 13 AV/Graphics Staff Checklist Sheet 2 of 3 JNC Operational Activities Notes 8.0 Media Briefings Perform the following tasks:
- Wireless microphone for Company Spokesperson
- Arrange and operate, as necessary, PowerPoint presentations and other visuals for Company Spokesperson as needed, operating the computer equipment necessary on stage. Refer to database of photography, system drawings and computer animation files on Media Briefing Room computer and removable drive for use at JNC.
- Record and videotape Media Briefings
- Coordinate staff to handle wireless microphone for Q&A - DO NOT give microphone to individual media representative asking question
- Prepare tapes for playback 3.0 Post Event
- Close down and return all equipment to its original condition, being careful to follow posted sequences and processes. Refer to the AV Equipment Instructions manual in the AV Control Room.
- Ensure the projector is shut off first and the fan activates, BEFORE turning off the stage lights
- Close all open graphics on the computer, and shut down the computer
- Return all equipment to its stored location
- Participate in debriefing and then return work area to startup condition before departing facility Page 56 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 13 AV/Graphics Staff Checklist Sheet 3 of 3 Media Briefing Room Resource Listing The following are available in the Media Briefing Room as references:
- Schematics of the nuclear power facility
- Maps showing: 10 mile EPZ, ERPAS, wind/plume direction
- News Media Kits (contents)
- Emergency Planning Brochures
- Plant Status Boards Graphics and Photographs (located on computer hard drive and CD)
Page 57 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 14 Public Inquiry Coordinator Checklist Sheet 1 of 1 Primary Responsibilities Under the direction of the JNC Director, supervise Public Inquiry, Media Referral and Media Monitoring staff until the NY State Pubic Inquiry Supervisor arrives from Albany; apprise JNC Director of rumors, inaccuracies using State Forms and coordinate corrective actions; provide rumors and inaccuracies to State and County JNC Representatives, as appropriate; track to completion corrective actions; coordinate receipt of updated information and provide to PI, Media Referral and Media Monitoring staff; update status board, as appropriate.
Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A - refer to position checklist, and Report to Public Inquiry Room (Ensure Media Monitoring room is un-alarmed and open for set up Media Monitoring staff)
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Supervise until NY State Supervisor arrives. Assign available Public Inquiry staff to sit in order of phone roll sequence, Ensure set up in Media Monitoring area JNC Operational Activities 2.0 Ongoing Responsibilities
- Update NY State Supervisor upon arrival and after absences from room
- Review official written statements (from utility, state or county and EAS messages ONLY) for dissemination through Public Inquiry and Media Referral staff, and remain up-to-date with official information provided to the media
- Check completed logs, state forms and Inquiry/Monitoring Forms (Form IP-101 -
- 11) of Media Monitoring and Public Inquiry/Media Referral staff, and Coordinate call-backs as needed
- Inform JNC Director of repeated inquiries' or news reports containing rumors or misinformation received by Public Inquiry Room or Media Monitoring (using State Form provided), and coordinate distribution to appropriate JNC Representatives for corrective actions
- Track corrective actions to completion, coordinate assignment of corrective actions with the JNC Director and/or appropriate agency representative in the JNC. Follow up if necessary to ensure completion.
- Attend periodic JNC facility briefings as necessary, and provide any JNC administrative information to the Public Inquiry, Media Referral and Media Monitoring staff.
- Coordinate with and request needed written information from JNC Director when deemed necessary to ensure prompt receipt of approved information for use in Public Inquiry, Media Referral and Media Monitoring 3.0 Post Event
- Participate in debriefing and then return work area to startup condition before departing facility Page 58 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 15 Public Inquiry Staff Checklist Sheet 1 of 1 Primary Responsibilities Under the direction of Supervisor, Public Inquiry (NY State) or Entergy Public Inquiry Coordinator provide incoming callers (the public) with requested information, clarification of information as necessary, and direct callers to official outlets for information.
Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A - refer to position checklist
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Report to Public Inquiry Room JNC Operational Activities 2.0 Ongoing Responsibilities
- Obtain and review all existing and up-to-date official WRITTEN information on the event. Do NOT use unofficial, verbal or other non-written information as a source).
- Answer phones "Joint News Center", providing only your first name. If asked, your position is Public Inquiry staff member for the caller's purposes. You do NOT need to provide your full name, or normal company position.
- Fulfill Public Inquiry function referring to available background and official written emergency reference materials, including
- Written Statements (news releases) and EAS Messages Emergency Planning Brochure for each County, including Map inserts
- State Common Questions source document (in Position Binder)
- Yellow Pages Insert
- Joint News Center Public Education Work Plan (in Public Inquiry Room),
- Provide accurate information obtained from utility, state and county written news releases or EAS to callers as needed
- Follow Good Practices for each call:
- Show care and concern for each caller. Be courteous and patient.
- Be prepared - by developing a good understanding of the IP, of plans and practices in dealing with emergencies, and by following events as they unfold
- Be responsive to callers - by answering questions as accurately and fully as practicable and/or by taking follow-up action
- Attempt to conclude each call without additional requirements, but if necessary, either refer the caller to the Public Inquiry Coordinator if unable to bring closure to the call, or if needed for any other reason, OR indicate a call back will be made if deemed appropriate. (Call backs should be a last resort)
- Identify false statements/rumors on forms provided ("Public Inquiry - Media Response Inquiry and Off Air Monitor Form) and notify Public Inquiry Coordinator. Attempt to clarify misinformation or resolve confusion at the time with the caller.
- Complete logs and Inquiry/Monitoring Forms (see below) during or after each call. As requested, Turn in log sheets to the Public Inquiry Coordinator.
3.0 Post Event
- Participate in de-briefing and then return work area to startup condition before departing facility Page 59 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 1133 JNC Operations Manual Attachment 16 Media Referral Staff Checklist Sheet 1 of 2 Primary Responsibilities Under the direction of the Supervisor, Public Inquiry (NY State) or Entergy Public Inquiry Coordinator, respond to telephone inquiries from news media not able to come to the JNC; refer media to official sources of information and provide directions to JNC; monitor media websites for inaccuracies in information being reported; notify Public Inquiry Coordinator of misinformation, rumors and other issues. Media Referral/Contact number is announced in the first Media Briefing and is included in written statements provided by the JNC participants Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Report to Public Inquiry Room for position checklist
- Report to State Public Inquiry Supervisor, or Entergy Public Inquiry Coordinator
- Review official written information on plant event (news releases)
JNC Operational Activities Notes 2.0 Ongoing Responsibilities
- Answer telephones, "Joint News Center", respond to media not present at JNC by:
- Advising news organizations to send a representative to the JNC or rely on wire service reports for updates
- Read and/or arrange to provide written statements (by fax) to media outlets who request it (coordinate this activity with the Public Inquiry Coordinator first)
- Refer non-media calls to Public Inquiry Supervisor/Coordinator (which require information beyond the scope of information provided)
- Do not elaborate, speculate, or render personal opinions
- Media inquiry staff:
- keep current with all official/written information related to the emergency that is authorized for release (news releases, EAS messages ONLY)
- respond to inquiries using pre-approved language and do not deviate from already released information
- record all contacts including time and nature of inquiry using Inquiry/Monitoring Form, (Form IP-1 011-11))
- Provide a summary of logged calls for pre-briefings, if requested.
- Monitor media web sites for inaccuracies and provide any to Public Inquiry Coordinator on completed forms
- Maintain log of media calls and actions taken
- Identify false statements/rumors on forms provided and notify Public Inquiry Coordinator.
Page 60 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 16 Media Referral Staff Checklist Sheet 2 of 2
- Complete logs and forms during or after each call. As requested, turn in log sheets to the Public Inquiry Coordinator.
3.0 Post Event
- Give media log to Documenter at end of event
- Participate in debriefing and then return work area to startup condition before departing facility Page 61 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 17 Media Monitoring Staff Checklist Sheet 1 of 1 Primary Responsibilities Under the direction of Public Inquiry Coordinator or State Public Inquiry Supervisor, monitor news (TV, Radio) reports for accuracy; review newspaper and other publication stories for accuracy; report any inaccuracies or rumors to Public Inquiry Coordinator or State Public Inquiry Supervisor.
Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Report to Media Monitoring Room and refer to position checklist. If not open, ensure someone opens the room and un-arms the alarm.
- Turn on and check monitors, VCRs and other equipment for working order, date, time - report any equipment problems to IT Representative or Administrative Manager for resolution. Check radio stations as labeled on radios
- Place tapes in each recording device, if not already done, and begin continuous recording
- Obtain and review official information on plant event (news releases)
JNC Operational Activities 2.0 Ongoing Responsibilities
- Remain up-to-date with official information provided to the media as it becomes available through News Releases and EAS messages
- Monitor and record news broadcasts from major TV and radio stations for rumors and inaccuracies regarding the event
- Report any inaccuracies or rumors to Public Inquiry Coordinator or NY State on
'Public Inquiry -- Media Response Inquiry and Off Air Monitor Form" in position guide book at JNC. .
- Tapes may be requested for viewing. If so, replace tape and continue continuous recording process. Provide tape to either Public Inquiry Coordinator or JNC Director if requested.
- Monitor taping to ensure tapes do not run-out. Replace tapes as necessary, and label all full/completed tapes with date, times of recording, and station
- Maintain written log of rumors and inaccuracies, including date, time, channel/station aired on and content 3.0 Post Event
- Provide log to Documenter and all tapes to JNC Director at end of event
- Participate in de-briefing and then return work area to startup condition before departing facility Page 62 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 18 JNC Documenter Checklist Sheet 1 of 2 Primary Responsibilities Under the direction of Administrative Manager, implement required documentation procedures; prepare and maintain logs of all documentation, final approved news releases, EOF to JNC Essential Information Checklist and other plant status materials; maintain News Release status board; collect information as required including sign-in registration sheets, rosters, etc.
Mobilization and Activation Activities
- Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Report to Utility Room A - refer to position checklist
- Create a Master Binder with tabs for the event to contain all documentation resulting from event (written statements from Entergy, state, counties, copies of EAS messages and Emergency Summary Sheets, EOF to JNC Essential Information Checklist, plant status reports). Binders and other materials are maintained in the bottom drawer of the file cabinet in Utility Room A and/or in the JNC storage room.
- Log on to the computer and locate the documentation log in c:/myfiles/documeterlog.doc
- Ensure date stamp has correct date/time, using the official time provide by the Administrative Manager. All paperwork received should be date stamped.
JNC Operational Activities 2.0 Ongoing Responsibilities Written Statements
- Update and maintain News Release white board in Utility Room A that keeps track of issued news releases (note content/title of news release(s) under development and time approved)
- Log key events (Emergency Classification changes, shift changes and attendance), time logs of operations (change in command, shift changes, times of pre-briefings, briefings)
- Keep a time log of when news releases or other written statements need to be issued, as soon as possible and within one hour of learning of a change in emergency classification and monitor preparation time; advise JNC Director and JNC Writer of time remaining to issue statement for each Emergency Classification change
- Log copy of every news release issued by the state and counties
- Log all Entergy final approved news releases Sheet 2 of 2 Page 63 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 1P3 JNC Operations Manual Attachment 18 JNC Documenter Checklist Sheet 2 of 2 JNC Operational Activities (cont'd.) Notes Event Information
- A time log of every Emergency Classification Level (ECL) as announced in utility room - Notification of Unusual Event; Alert; Site Area Emergency; General Emergency
- Establish and maintain file of following documents:
- All Emergency Alert System (EAS) messages
- All Emergency Summary Sheets (Form IP-1011-4)
- All EOF toJNC Essential Information Checklists (Form IP-1011-1)
- All original Written Statement Distribution Checklists (Form IP-101 1-5)
- All data received by fax from EOF - plant status information Pre-Briefings
- A log of time for every departure/return from Pre-Briefing
- A log of time for every change in command and time of change Briefings a Log start and end time of Media Briefings
- A log of every return from Briefing to Utility Room A Shift Information A log of every shift change and time of change, including personnel attendance sheets and registration logs 7.0 Post Event
- Check binder to make sure all documentation is complete
- A copy of every document distributed in Utility Room A under the appropriate tab
- Label binder with date of event
- Hand deliver completed log book to JNC Director for delivery to Recovery Manager
- Ensure work area is in startup condition
- Participate in de-briefing and then return work area to startup condition before departing facility Page 64 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 19a Registration Coordinator Checklist Sheet 1 of 1 Primary ResDonsibilities Under the direction of the Administrative Manager, provide all registration functions for the JNC, including checking identification of persons entering the JNC and getting authorization if necessary; registering and issuing (as necessary) authorized personnel; collecting badges and logging out all personnel when they leave.
Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A - refer to position checklist, and set up registration (if not already done)
- Report to Administrative Manager and confirm registration/sign in area is set up
- Ensure all personnel entering JNC are properly identified and badged
- Ensure Media is directed to Media areas only - explain "authorized personnel" areas JNC Operational Activities 2.0 Ongoing Responsibilities
- Examine ID credentials of all people entering facility (no exceptions) (Official agency IDs or driver's license are acceptable if driver's license is used, obtain authorization from the senior representative present in the JNC from the utility, state or county indicated.)
- Provide colored badges to Media who enter, media representatives should provide picture identification or press credentials
- Maintain sign-in list of all arrivals
- Ensure all participants wear ID's (Entergy or other agency ID)
- Report any unusual incidents to Administrative Manager 3.0 Post Event
- Ensure registration area is returned to startup condition
- Provide all Registration Sheets to Utility Room Documenter
- Prepare all Registration Books for future use
- Participate in de-briefing if requested by Administrative Manager Page 65 of 91
IP2 P-1 01 1, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 19b Administrative Support Staff Checklist Sheet 1 of 2 Primary Responsibilities Under the direction of the Administrative Manager, ensure efficient internal JNC distribution of plant status and all other written statements/information; ensure external distribution of final written statements to designated personnel (external to JNC); and provide other administrative support as requested including acting as runner, posting status sheets for JNC TechnicalAdvisor,_etc.
Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Refer to position checklist, check equipment and supplies - replenish necessary supplies.
- Report to Administrative Manager, and request assignment to set up facility
- If not already assigned, report to the Fax/Copy Room to determine if there are any incoming faxes waiting. If so, immediately copy and provide to the Administrative Manager and/or JNC Director
- If not already done/assigned, check fax machines for correct date, time and operability (see manual for instructions). Administrative Manager will provide the official time (from the JNC Director)
- If not already done/assigned, check for operability of copiers and adequate paper supply; report any problems to Administrative Manager
- Set up log book for incoming/outgoing faxes in Fax/Copy Room JNC Operational Activities 2.0 Ongoing Responsibilities
- Copy and/or Fax documents as requested by Administrative Manager, completing the Written Statement Distribution Checklist (Form IP-1011-5) to track and document actions, and the Fax Distribution sheet as provided by the Administrative Manager. DO NOT SEND THE FAX DISTRIBUTION FORM AS PART OF THE OUT-GOING FAXES.
- Contact Administrative Manager with problems, questions or feedback
- Support Administrative Manager in other JNC activities as needed Page 66 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 19b Administrative Support Staff Checklist Sheet 2 of 2
- Make copies of and distribute information such as plant status reports, EOF to Notes JNC Essential Information Checklist and EAS messages. Follow the Information Distribution Guide located in Addendum 8 (Form IP-1011-6) and in your position binder.
Follow the priorities included in the Information Distribution Guide and the Written Statement Distribution Checklist (Addendum 7) to ensure information is promptly provided to those who need it.
- Maintain a log of all incoming and outgoing faxes, and complete fax distribution by following Fax Distribution sheet provided by Administrative Manager to designated recipients.
- Written Statements should be distributed using the Written Statement Distribution Checklist (Form IP-1 01 1-5) . The Administrative Manager will notify the Administrative Support Staff when materials are ready for copying and distribution
- Administrative Support may be provided to the JNC Technical Advisor to post on the Utility work room walls status and updates of the plant conditions and response activities.
- Administrative Support may be asked to support manning of Pre-Briefing conference call phone, to log and handle any incoming calls and to place outgoing calls, if requested to do so by the Agency Liaison 3.0 Post Event
- If requested by Administrative Manager, participate in de-briefing
- Assist Administrative Manager in restoring each workroom to startup condition Page 67 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations M~anual Attachment 20 IT Representative Checklist Sheet 1 of 1 Primary Responsibilities Under the direction of the Administrative Manager, monitor IT equipment throughout the JNC to ensure proper working order; troubleshoot problems and assist with IT and computer related difficulties; coordinate solutions via the Administrative Manager.
Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A and refer to position checklist
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Report to Administrative Manager
- Support set up/initial operability test of the IT equipment in the Utility work rooms and the Media Briefing Room. Coordinate directly with the Audiovisual Coordinator on Media Briefing Room set up, as needed.
- Synchronize time in Utility Room A with JNC Director
- Obtain and review official information on plant event (news releases)
JNC Operational Activities 2.0 Ongoing Responsibilities
- Remain available to support personnel with equipment problems through the JNC.
- Receive reports of difficulties directly or via the Administrative Manager
- Troubleshoot problems, and correct those that are possible to close out.
- Develop solutions for larger issues, and coordinate solutions with the Administrative Manager.
- Receive approval and/or direction on approach to larger issues and solutions from the Administrative Manager and/or JNC Director
- Maintain written log of actions, solutions, requirements and future needs 3.0 Post Event
- Provide log to Documenter at end of event
- Participate in de-briefing and help return JNC to startup condition before departing facility Page 68 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 21 Radiological Advisor Checklist Sheet 1 of 1 Primary Responsibilities As an optional position, activation is at the discretion of the JNC Director or Company Spokesperson. Once activated, reporting to JNC Director, provide information and advice to the Company Spokesperson on radiological information due to plant events; review written statements and monitor Media Briefings for accuracy relative to radiological aspects.
Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board in hallway by Utility Room A
- Report to Utility Room A and refer to position checklist JNC Operational Activities 2.0 Ongoing Responsibilities
- Review plant status reports, EOF to JNC Essential Information Checklist, written statements, online data and other information as it becomes available and advise Company Spokesperson as appropriate on radiological consequences/aspects 3.0 Written Statements
- Review and provide technical comments on written statements on radiological implications of plant events as requested 4.0 Pre-Briefings
- Advise Company Spokesperson and JNC Technical Advisor on radiological implications of plant events
- Assist Company Spokesperson compile notes for Media Briefings as needed 5.0 Media Briefings
- Monitor Media Briefings and take notes on Media Briefing Issues form in Addendum 4 (Form IP-1011-2) regarding radiological statements, questions and answers. Note inaccuracies, inconsistencies and unanswered questions and provide to JNC Director, if directed
- Ensure unanswered questions or inaccuracies are addressed during preparation of next Media Briefing 6.0 Post-Briefing
- Provide feedback on briefings to JNC Director and Company Spokesperson
- Assist in addressing inaccuracies, inconsistencies and unanswered questions as needed to prepare for subsequent media briefings or news releases 7.0 Post Event e Participate in debriefing and then return work area to startup condition before departing facility Page 69 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Attachment 22 Radiological Health Expert Checklist Sheet 1 of 1 Primary Responsibilities Reporting to Media Room Manager, serve as an information source to provide independent, technical background information to the news media in the Media Briefing Room on issues related to radiation exposure and health impacts of radiation; monitor Media Briefings for accuracy Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board in hallway by Utility Room A
- Report to Media Room Manager in Media Briefing Room - Refer to position checklist located in AV Control Room behind stage
- Review issued written statements, and report any inaccuracies to the Media Room Manager JNC Operational Activities Notes 2.0 Ongoing Responsibilities
- Remain in Media Briefing Room to provide the media with technical background information related to radiation exposure and its health effects. Do not elaborate on plant conditions, speculate, or render personal opinions
- Relay information to Media Room Manager on reporters' questions as feedback for use in preparing for next briefing 3.0 Media Briefings
- Monitor Media Briefings using Media Briefing Issues form in Addendum 4 (form IP-1 01 1-2) for accuracy; relay comments to Media Room Manager 4.0 Post Event
- Participate in debriefing and then return work area to startup condition before departing facility Page 70 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 1133 JNC Operations Manual Attachment 23 Security Checklist Sheet 1 of 1 Primary Responsibilities Under the direction of the Administrative Manager, provide all security functions for the JNC. Security officers maintain posts at registration areas, ensure orderly access through registration area, ensure individuals within the JNC display badges at all times, ensure only ERO responders have access to the JNC work areas, unless escorted by a properly badged individual, and verify security of entrances and access points.
Mobilization and Activation Activities Notes 1.0 On arrival at JNC
- Register in lobby and sign Utility Sign-In board outside Utility Room A - refer to position checklist
- If among the first to arrive at the JNC, ensure registration and security are established or perform these functions until others arrive, and ensure the facility work rooms are open and set up is underway.
- Report to Administrative Manager and confirm where security will be established
- Establish post outside Media Briefing Room near stairway leading to 1 ' floor JNC work areas
- Establish post on 1t floor at the entrance to JNC work areas near Registration Desk
- IF a third officer is present THEN direct them to rove JNC areas checking worker badges and provide relief to posted officers
- Ensure all personnel entering JNC are properly identified and badged
- Support Registration personnel in directing media to designated areas only -
explain authorized personnel " areas JNC Operational Activities 2.0 Ongoing Responsibilities
- Ensure all ERO responders wear ID's
- Report any unusual incidents to Administrative Manager
- Monitor hallways for unauthorized individuals
- Maintain secure access for utility, state and county representatives
- Ensure appropriate access to Media Briefing Room for media representatives
- Ensure Media does not enter "Authorized Personner areas 3.0 Post Event
- Participate in de-briefing if requested by Administrative Manager Page 71 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 1133 JNC Operations Manual Attachment 24 Emergency Operations Facility (EOF) Information Liaison Checklist Sheet 1 of 1 Primary Responsibilities Function as both information gatherer and the primary liaison to the IP Communications Representative initially and the JNC once activated; provide plant information and response activities relating to plant events; update JNC Technical Advisor, respond to JNC information requests.
Mobilization and Activation Activities Notes 1.0 Upon notification:
- Establish communications with EOF staff, the IP Communications Representative and JNC Technical Advisor, if activated
- Turn on designated computer and locate EOF liaison folder for EOF to JNC Essential Form template, and establish email capability to the IP Communications Representative (their current location email address should be established when making contact) and JNC Technical Advisor, once activated
- Obtain up-to-date information and begin to document available information on the EOF to JNC Essential Information Checklist (Form IP-101 1, Rev.2). Fax all completed forms to the JNC Fax/Copy Room.
- Coordinate the review and approval of news release(s) with the IP Communications Representative, ensuring prompt approval by the Emergency Director
- Confirm with the IP Communications Representative that all required notifications to officials (Groups #1 and #2) have been made in order to distribute each news release.
- Coordinate with the IP Communications Representative to distribute the news release. Distribution includes the JNC and EOF, media and other Entergy location. If requested, print and send via fax the news release on the machine located at the EOF Information Liaison work area. Numbers are pre-programmed and/or available on the Fax Distribution form (see below)
- Update JNC Technical Advisor with information relating to plant events both verbally and using the EOF to JNC Essential Information Checklist (Form IP-101 1-1), Addendum 3, at roughly 30-minute intervals or as events warrant.
- Ensure prompt distribution of completed forms and official news releases as appropriate within the EOF
- Respond to requests from JNC for information
- Receive and post final news releases from JNC on bulletin board in EOF Information Liaison work area 3.0 Post Event
- Participate in EOF de-briefing and then return work area to startup condition before departing facility
- Forward debriefing suggestions to JNC Director Page 72 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum I JNC Location Map & Floor Plans Sheet 1 of 3 The Indian Point Joint News Center is located In the formerAir National Guard Building Number 1, located at the Westchester County Airport. Use Exit 2 off of Interstate 684.
(Map not to scale)
Airport Access Road Joint News Exit 2 L_ . Center off -
Interstate 684 Westchester Airport
- a. C 0
C 0
- C I
= 0 zI Page 73 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual
'Addendum 1 JNC Location Map & Floor Plans Sheet 2 of 3 Page 74 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 1 JNC Location Map & Floor Plans Sheet 3 of 3 Registration Main Entrance Page 75 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 1P3 JNC Operations Manual Addendum 2 JNC Functional Organization Chart Sheet 1of 1 Page 76 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 3 EOF to JNC Essential Information Checklist (Form IP-1011-1)
Page 1 of 1 EOF to JNC Essential Information Checklist Emergency Classification: Reactor: 0 At Power Tripped Time: EAL#: RCS Temp: °_
F Pressure: PSIG OOAUnusual lert_
Event RVLIS I Pressurizer Level:
O Site Area Emergency Subcooling method:
O General Emergency _ Weather Forecast:__ __ __
Method of Core Cooling: 0 SIG 0 Safety Injection 0 RHR Electrical Power Supplies Available: 0 138 KV 0 13.8 KV # Diesel Generators Event
Description:
Major Equipment Problems/Priorities:
O No Radiological Release 0 Release of radioactive materlals due to event O Radiological Release below I above federally approved operating limits Radiological Release to: 0 Atmosphere 0 Water 0 Unmonitored release requiring evaluation
- of Onsite Teams # of Offsite Teams Fission Product Barrier Status Accountability Completed At: Bari rler Intact Challenged Lost
- Not accounted for r Fuel I Clad 0 0 0 Actions being taken for search & rescue: RCS 0 0 0 Conl tainment 0 0 0 ERO Staffing: 0 YES 0 NO 0 In progress Status of other IP Unit:
Release of Non-essential Personnel OYES 0 NO Injuries: _ _ Employee Contractor Release of Non-essential Personnel DYES 0 NO Type of Injuries:
O Hospital Released / Admitted O Contaminated This Checklist was Completed: I - By:
ii..
Form IP-1011-1 Rev. I Page 77 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 4 Media Briefing Issues (Form IP-1011-2)
Sheet 1 of 1 Media Briefing Issues Time Noted: INoted By:
Type of Issue: 0 Incorrect Information 0 Additional Information Needed 0 Clarification Requested 0 Unanswered Question Issue:
Type of Resolution: 0 Provide Information to Media Member 0 Include in Written Statement Include in Next Media Briefing 0 Brief Spokesperson(s) 0 Other Resolution Details:
Page 1 or 1 Form IP-1011-2 Rev. 1 Page 78 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 5 JNC Staffing (Form IP-1011-3)
Page 1 of 4 i o n B i . Ace- 4ff#L~~~~z4_t17,q, *tf +*9 RIACtt;A "it<-qn a9te M Mi-,1V lx a I = TS'A~~~~~~~tAIF...
'S I n GW-WthGW m~~~~~~~~~~~~~~se~~i> M4 1"' Shift Time Time 2 nd Shift Time Arrived Time Position Name (print) Arrived Departed Name (print) Departed Cmpny. po es person..* Kr-H Technical Briefer Media Room Liaison JNC Writer JNC Documnenter Audiovisual Coordinator Page 1of 4 Form IP-011-3 Rev. 3 Shaded positions entail functions that are required for activation Page 79 of 91
I IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 5 JNC Staffing (Form IP-1011-3)
Page 2 of 4 I' Shift Time Time 2nd Shift Time Arrived Time Position Name (print) Arrived Departed Name (print) Departed Alle Meia Mnitoing ~StaE JNC Administrie dSpt Media Refetral Staff Member(s)
Page 2 of 4 Form IP-1011-3 Rev. 3 Shaded positions entail functions that are required for activation Page 80 of 91
IP2 IP-1 01 1, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 5 JNC Staffing (Form IP-1011-3)
Page 3 of 4
_ __ __ _ _ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
~~~~~~~~~~~~~~~~~~~~~~~~~~~~UV
_ _ _ _ _ _ _ _ , ~ ~-~ ~ . _ _ _ _ _
1it Shift Time Time 2 nd Shift Time Arrived Time Position Name (print) Arrived Departed Name (print) Departed Public Inquiry Staff (as required)
IT Representative Radiological Advisor Page 3 of 4 Form IP-1011-3 Rev. 3 Shaded positions entail functions that are required for activation Page 81 of 91
f t
IP2 IP-1011, Joint News Center, Rev. 6 1P3 JNC Operations Manual Addendum 5 JNC Staffing (Form P-1011-3)
Page 4 of 4 ins _ __
1" Shift Time Time 2 nd Shift Time Arrived Time Position Name (print) Arrived Departed Name (print) Departed Radiological Health Expert
- it r-4'
- __________________________________________ ____________________ ____________________ __________________________________________ ________ ________________ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __.
1 I I I I III A Page 4 of 4 Form IP-1011-3 Rev. 3 Shaded positions entail functions that are required for activation Page 82 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 6 Emergehcy Summary Sheet (Form IP-1011-4)
Page 1 of 1 Indian Point Emergency Summary Sheet Energy Center 0 0
Time:
Date:
- 1. This is a Drill z This is an Actual Event l IPutnam Count
- 2. Emergency Classification: \_Westchester Unusual Event 0_ County 270 - 90 Alert l Site Area Emergency Q General Emergency 0
- 3. Event
Description:
0 4Radiological Condition:18
- 4. Radiological Conditions:
Release of I Radioactive Materials No Release due to the classified event. ° Release BELOW federally approved operating limits (Technical Specifications)
E To Atmosphere 0 To Water Release ABOVE federally approved operating limits (Technical Specifications) 0 To Atmosphere 0 To Water Unmonitored Release - Being Evaluated
- 5. Meteorological Conditions:
Wind Speed: MPH Wind Direction: .
General Weather Conditions:
(To convert Meters sec to Miles Hr divide by .46) Form IP-101 1-4 Rev 1 Page 83 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 7 Written Statement Distribution Checklist (Form IP-1011-5)
Sheet 1 of 2 Written Statement Distribution Checklist Follow each step below as assigned. Some steps are concurrent, as noted by the numbering. Administrative Manager Statement Number: ; .
m I is to confirm all steps are completed at conclusion. ______.._i_______':___
Step JNC Position Detail Description Completed By (Print)
Responsible _________
1 Administrative Obtain "APPROVED WRITTEN STATEMENT/NEWS RELEASE' Manager from Company Spokesperson and start distribution process:
O Stamp original with Sign-Off stamp, have Company Spokesperson initial, notify Documenter of approval time O Start a Written Statement Distribution Checklist and Fax Distribution Sheet (in Position Binder and file cabinet) o Record Statement Number above o Give Original statement with Distribution Checklist and Fax Distribution sheet to Administrative Support Staff to
-. _ make initial copies..
2 Assigned o Make 12 copies of statement Admin. o Provide Agency Liaison with 0 Copies for distribution to Support Staff county, state and federal workrooms, plus the original to Person document acknowledgment on the back and this Distribution Checklist O Provide Administrative Support Staff in fax/copy room with 2 copies (one for further copying and one for fax distribution (see below) 3a Agency Obtain acknowledgment (on JNC written statements after activation I Liaison statement ONLY) from:
Note: State and County o New York State PlOs not present shall O Westchester County be notified via phone in o Putnam County Pre-Brief room. If NRC or FEMA PlOs are not o Rockland County present note on o Orange County (via phone if necessary) stamped copy and continue distribution. o NRC
, o FEMA o Give completed signed -off original statement and this Distribution Checklist to Staff in Fax/Copy Room Page 1 of 2 Form IP-1011-5 Rev. 3 Page 84 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 7 Written Statement Distribution Checklist (Form IP-1011-5)
Sheet 2 of 2 Written Statement Distribution Checklist Follow each step below as assigned Administrative ManagerIs Statement Number:
to confirm afl steps are completed. ___________
3b Admin. Make 32+ copies of final written statement/news releases and Support Staff coordinate distribution with other Administrative Support Staff as in FaxlCopy follows:
area 0 10 Copies to Public Inquiry Coordinator o 2 Copies to Media Monitoring Room Personnel o 7 Copies to Utility Room 0 12+ Copies to the Media Room Liaison for media (coordinate number needed with Media Room Liaison) o Post 1 Copy on Bulletin Board near JNC Writer O Upon completion, provide original statement with acknowledgements and this Distribution Checklist to Administrative Manager Concurrently, ensure statement is faxed to locations indicated on the Fax Distribution Form. DO NOT SEND FAX DISTRIBUTION FORM IN OUT-GOING FAX TRANSMISSION o Complete fax distribution to media, other emergency facilities and other Entergy locations (as indicated on the Fax Distribution Form) o Review Fax Confirmation sheets to ensure they state that all transmissions were successfully completed (the text of the confirmation will read OK) o Upon completion, provide fax confirmation sheet(s) to Administrative Manager 3c Administrative Provide original (acknowledged) statement; fax confirmation(s); and Manager this Distribution Checklist to JNC Documenter for log keeping Page 2 of 2 Form IP-1011-5 Rev. 3 Page 85 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 8 Information Distribution Guide (Form IP-1011-6)
Sheet 1 of 1 Information Distribution Guide Information Information_ Recipient (follow order for distribution, if possible)
_ __ _ __ __ _ __ _ __ __ _ _ o Distribution pleted By (Print)
Plant Status, Utility Room A & B including Forms 0 JNC Technical Advisor (& Radiological Advisor) and plant parameters 0 Company Spokesperson (received via fax or 0 JNC Director from/via JNC 0 JNC Documenter Technical Advisor)
EAS Statements ALL Locations/All positions (provided by State 0 Public Inquiry Room & Media Monitoring Room or via Agency Liaison) O Utility Rooms A & B o State, County and Federal Work Rooms o Media Briefing Room (at assigned time provided by State or Agency Liaison)
Written Statements, Follow Written Statement Distribution Checklist form including news releases All Other Request distribution instructions from the Information Administrative Manager and/or JNC Director Received (via fax or otherwise) .
Page 1 of 1 Form IP-1011-6 Rev. 0 Page 86 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 9 RUMOR CONTROL - MEDIA MONITORING - MEDIA RESPONSE (Form IP-1 011-7)
Page 1 of 1 RUMOR CONTROL - MEDIA RESPONSE INQUIRY AND OFF AIR MONITOR FORM Type of call: (Public Inquiry) (Professional Inquiry) (Media Inquiry) (Media Monitor Report)
Date of call/broadcast: --- Time of call/broadcast:
Name of responder/monitor:
Media Name/Location:
Caller's/Reporter's name: Phone: () -
Question(s) asked/Inaccurate Information:
Response given/Correct Information and Source:
Is call back required: A_) Yes (a) No Call Back Number ( -
If yes, call back completed at: By:
Was the call referred: ) Yes() No If yes, to whom?
Further action required: (_) Yes () No Was this action completed? _) Yes (j No By Reported to Rumor Control Coordinator at___
Rumor Control Coordinator Notes:
Return completed form to Rumor Control Coordinator:
Page 1 of 1 Form IP-101 1-7 Rev. 0 Page 87 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 10 Fax Distribution Page 1 of 3 ENTERGY - IP Communications/JNC - FAX DISTRIBUTION DATE: TIME: _
SUBJECT:
PLEASE FAX THE ATTACHED DOCUMENT(s) TO THE MARKED GROUP(s) (JNC Panafax one-touch numbers are provided as #):
0 # 9 IP EOF - .................................. 914-739-2499 1#10 IP AEOF ......................... .. . 91 4 914-682-5222 O #14 WIRE SERVICES (Group)
AP/NYC. ...................................... 212-621-1639 AP/WESTCHESTER - .............. 914-946-0721 REUTERS- .............. 212-859-1790 GANNET SUBURBAN NEWSMWHITE PLAINS-.......... 914-694-5018 BLOOMBERG-.................................. 609-497-6577 PR NEWSWIRE- .................................. 201-432-8541 O #2 ENTERGY MEDIA RELATIONS (Group)
IP2 PR-.................................. 914-734-5858 IP3 PR- .................................. 914-736-3225 WPO PR .................................. 914-272-3365 KELLE BARFIELD- .................................. 601-368-5659 JAF PR ............................... 315-349-6688 PILGRIM PR-............................... 508-830-8357 MIKE KANSLER ............................... 914-272-3205 IP2 SITE VP - .............................. 914-734-5718 IP3 SITE VP - .............................. 914-739-5427 O #25 LOCAL OFFICIALS (Group)
CC: CORTLANDT .............................. 914-734-1003 CC: PEEKSKILL .............................. 914-734-4196 CC: BUCHANAN .............................. 914-737-6587 O #2 JOINT NEWS CENTER .............................. 914-683-6657 OR .............................. 914-683-8590 (FOR RECEIPT FROM EOF OR IP COMMUNICATIONS REPRESENTATIVE PRE-JNC)
Page 88 of 91
IP2 IP-1 011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 10 Fax Distribution Page 2 of 3 ENTERGY - EOF - FAX DISTRIBUTION DATE: _TIME:
SUBJECT:
B PLEASE FAX THE ATTACHED DOCUMENT(s) TO THE MARKED GROUP(s) (EOF one-touch numbers are provided as #):
O #1 JOINT NEWS CENTER ................................ 914-683-6657 0 #2 ALTERNATE JNC FAX ................................ 914-683-8590 O #3 IP AEOF .. ...................... 914-682-5222 O #4 WI RE SERVICES ................................. (Group)
AP/NYC ...................................... 212-621-1639 APVESTCHESTER ...................................... 914-946-0721 REUTERS ...................................... 212-859-1790 GANNET SUBURBAN NEWSJWHITE PLAINS ...... 914-694-5018 BLOOMBERG ...................................... 609-497-6577 PR NEWSWIRE ...................................... 201-432-8541 OC #5 ENTERGY MEDIA RELATIONS .................. (Group)
IP2 PR.914-734-5858 IPR ................................................................... 9 4 7 4 5 5 IP3 PR ...................................... 914-736-3225 WPO PR ...................................... 914-272-3365 KELLE BARFIELD ...................................... 601-368-5659 JAF PR ...................................... 315-349-6688 PILGRIM PR ...................................... 508-830-8357 MIKE KANSLER ...................................... 914-272-3205 IP2 SITE VP ...................................... 914-734-5718 IP3 SITE VP ...................................... 914-736-8012 O #6 LOCA L OFFI CIALS ................ . . . (Group)
CC: CORTLANDT ......... 914-734-1003 CC: PEEKSKILL ......... 914-734-4196 CC: BUCHANAN ......... 914-734-6587 EMERGENCY TELEPHONE DIRECTORY CONTAINS FAX NUMBERS Page 89 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 10 Fax Distribution Page 3 of 3 ENTERGY - AEOF - FAX DISTRIBUTION DATE: TIME:
SUBJECT:
B PLEASE FAX THE ATTACHED DOCUMENT(s) TO THE MARKED GROUP(s) (AEOF one-touch fax numbers are provided as #):
O # JOINT NEWS CENTER . ......................914-683-6657 O # ALTERNATE.JNC FAX . ...................... 914-683-8590 O # IP EOF............. .. 91 4-739-2499 O # WIRE SERVICES ....... ............... (Group)
AP/NYC ......................... 212-621-1639 APMWESTCHESTER ......................... 914-946-0721 REUTERS ......................... 212-859-1790 GANNET SUBURBAN NEWS/
WHITE PLAINS ......................... 914-694-5018 BLOOMBERG ......................... 609-497-6577 PR NEWSWIRE ......................... 201-432-8541 O # ENTERGY MEDIA RELATIONS .................... (Group)
IP2 PR ........ 914-734-5858 IP3 PR .... 914-736-3225 WPO PR. 914-272-3365 KELLE BARFIELD ........ 601-368-5659 JAF PR ........ 315-349-6688 PILGRIM PR ........ 508-830-8357 MIKE KANSLER ........ 914-272-3205 IP2 SITE VP ........ 914-734-5718 IP3 SITE VP ........ 914-736-8012 O # LOCAL OFFICIALS ....... ....... .. (Group)
CC: CORTLANDT ........ 914-734-1003 CC: PEEKSKILL ........ 914-734-4196 CC: BUCHANAN ........ 914-734-6587 EMERGENCY TELEPHONE DIRECTORY CONTAINS FAX NUMBERS Page 90 of 91
IP2 IP-1011, Joint News Center, Rev. 6 IP3 JNC Operations Manual Addendum 1 1 JNC Briefing Notes Guide (Form IP-1011-8)
Page 1 of 1 JNC BRIEFING NOTES GUIDE DATE: -
BRIEFING #
TIME: start:
End: _
BRIEFING
SUMMARY
EMERGENCY CLASSIFICATION LEVEL (ECL):
Unusual Event Alert Site Area Emergency General Emergency PLANT STATUS:
EVENT:
RESPONSE
RADIOLOGICAL CONDITIONS: