~Entergy Indian Point Energy Center Document Control 450 Broadway Buchanan, NY 10511 TO:
DISTRIBUTION CONTROLLED DOCUMENT TRANSMITTAL FROM: IPEC DOCUMENT CONTROL - 3Ro FLOOR ADMIN BLDG - JANEENE LEVEQUE X2903 TRANSMITTAL#: EP-20-0028 The Document(s) identified below are forwarded for use. Please review to verify receipt, incorporate the document(s) into your controlled document file: properly disposition superseded, voided, or inactive document{s).
THE FOLLOWING PROCEDUAE(S) HAVE BEEN REVISED~ PLEASE REMOVE YOUR CURRENT COPY AND REPLACE WITH ATTACHED UPDATED PROCEDURE:
EFFECTIVE DATE: 07/01/2020 ;4ilf5
- PLEASE NOTE EFFECTIVE DATE***********
N le f<
RECEIPT OF THE ABOVE LISTED DOCUMENT{S) IS HEREBY ACKNOWLEDGED. I CERTIFY THAT ALL SUPERSEDED, VOID, OR INACTIVE COPIES OF THE ABOVE LISTED DOCUMENT(S) IN MY POSSESSION HAVE BEEN REMOVED FROM USE AND ALL UPDATES HAVE BEEN PERFORMED IN ACCORDANCE WITH EFFECTIVE DATE(S)
{IF APPUCABLE)AS SHOWN.ON THE DOCUMENT(S}.
NAME (PRINT}
SIGNATURE DATE COPY LOCATION
- U.S. NUCLEAR REGULATORY COMMISSION ATTN: DOCUMENTCONTROLDESK 11555 ROCKVILLE PIKE ROCKVILLE, MD 20852
IPEC EMERGENCY PLAN DISTRIBUTION LIST GAP YEAR IP3 CONTROL ROOM IP3 SHIFT MANAGER IP2 CONTROL ROOM IPEC TSC NRC RESIDENT INSPECTOR DOC CONTROL DESK NRC NRC NEW YORK STATE OEM WESTCHESTER COUNTY OEM ROCKLAND COUNTY FIRE AND EMERGENCY SERVICES ORANGE COUNTY EMERGENCY SERVICES CENTER PUTNAM COUNTY BUREAU OF EMERGENCY SERVICES DELIVERED BY DOCUMENTS DELIVERED BY DOCUMENTS DELIVERED BY DOCUMENTS DELIVERED BY DOCUMENTS NRC NRC - ROCKVILLE, MD ADDRESS JAMES DANNA DEPUTY DIRECTOR TED FISCH DENNIS DELBORGO NICHOLAS LONGO SHANNON FISHER KEN CLAIR
<,-%'l\\'>,,'..:, <,
- c/':'.")\\,1.:.\\/ _:){;;; " ~ ~,
- YJ\\IDDl3E~;s ""l,*k,,",,
11;):JJ;~dMBER}b~ cbP1~sJ{/
- \\',>
- )c*,'
"'.> '.*,\\_',, *c,,,*?<t1;:?*>,..fttJ* 'J' IP3 53FT. CCR IP3 53FT. ELEVATION IP2 53FT. CCR IP2 53FT. ELEVATION IP2 88FT. ELEVATION OFFSITE OFFSITE OFFSITE OFFSITE OFFSITE OFFSITE OFFSITE
-,c
~
~ '
1 COPY OF ALL EP'S 1 COPY OF ALL EP'S 1 COPY OF ALL EP'S 1 COPY OF ALL EP'S 1 COPY OF ALL EP'S
'1 COPY OF ALL EP'S AND GENERAL RECORDS EXCEPT IP-EP-115*
1 COPY OF ALL EP'S AND GENERAL RECORDS EXCEPT IP-EP-115 1 COPY OF ALL EP'S AND GENERAL RECORDS EXCEPT IP-EP-115 1 COPY OF THE FOLLOWING:
E-PLAN, I P-EP-115, 120, 210,220,230,250,310, 320,340,360,410,420, 430, 620 & IP-1055 1 COPY OF E-PLAN, IP-EP-310 & 340 & 410 1 COPY OF E-PLAN, IP-EP-310 & 340 & 410 1 COPY OF E-PLAN, IP-EP-310 & 340 & 410 1 COPY OF E-PLAN, IP-EP-310 & 340 & 410
- THE FOLLOWING LOCATIONS ARE *ELECTRONIC DISTRIBUTIONS*
IPEC TRAINING NORVA BUTLER TRAINING 1 COPY OF ALL EP'S IP3 SIMULATOR CINDY STELLATO TRAINING 1 COPY OF ALL EP'S
IPEC EMERGENCY PLAN DISTRIBUTION LIST GAP YEAR Page 2 of 2 IP3 TRAINING CLASSROOMS CINDY STELLATO TRAINING 8 COPIES OF ALL EP'S IP3 SIMULATOR BOOTH CINDY STELLATO TRAINING 1 COPY OF ALL EP'S
IPEC IMPLEMENTING PROCEDURE IP-SMM-AD-102 Rev:17 PREPARATION, REVIEW, AND APPROVAL Page 35 of 43 ATTACHMENT 10.2 IPEC PROCEDURE REVIEW AND APPROVAL (Page1of1)
Procedure
Title:
Contamination Control Procedure No*
IP-EP-350 Existing Rev* 3 Procedure Activity New Rev* 4 Ol'il~
ORN/EC No* 18 ~
Temporary Procedure Change (MARK Applicable)
Converted To IPEC, Replaces:
(MARK Applicable)
NEW PROCEDURE Unit 1 Procedure No:
EDITORIAL Temporary Procedure Change GENERAL REVISION 0 PARTIAL REVISION Unit 2 Procedure No:
ADVANCE Temporary Procedure Change CONDITIONAL Temporary Procedure Change EDITORIAL REVISION Terminating Condition:
VOID PROCEDURE Unit 3 Procedure No:
SUPERSEDED RAPID REVISION Document in Microsoft Word:
VOID DRNff PC No(s):
Yes No Revision Summary N/A - See Revision Summary page._
Implementation Requirements Implementation Plan? Yes 0 No Formal Training? Yes 0 No Special Handling? Yes 0 No.
Quality Related? Yes 0 No. If Yes, then ensure the procedure cover page is marked "Quality Related" RPO Dept:
Emergency Planning
- 1. 0
- 2.
- 3. 0 Cross-Disciplinary Reviewers:
Dept: ______ Reviewer:--------,=-:,--,-,:-:----=-=~---:-=--~---------
(Print Name/ Signature/ Date)
Dept: ______ Reviewer:--------~------------------
_),int Name/ Signature/ Date)
RPO-Responsibilities/Checklist: Frank Mitchell/ P"V~~ ?/4$ ~
(Print Name/ Signature/ Date)
PAD required and is complete (PAD Approver and Reviewer qualifications have been verified) 0 Previous exclusion from further Ll-100 Review is still valid PAD not required due to type of change as defined in 4.6 *
- 4.
Non-Intent Determination Complete: __________________________ _
NO change of purpose or scope NO reduction in the level of nuclear safety NO voiding or canceling of a procedure, unless requirements are incorporated into another procedure or the need for the procedure was eliminated via an alternate process.
(Print Name/ Signature/ Date)
NO change to less restrictive acceptance criteria NO change to steps previously identified as commitment steps NO deviation from the Quality Assurance Program Manual NO change that may result in deviations from Technical Specifications, FSAR, plant design requirements or previously mad.e commitments.*
- 5. D On-Shift Shift Manager/GAS: _-------------------------:----
(Print Name/ Signature/ Date)
- 6.
User Validation: User: _______ _
- 7.
Special Handling Requirements Understood:. ________________________ _
ATTACHMENT 9.1 REVIEW Procedure/Document Number: IP-EP-350 j Revision: 4 Equipment/Facility/Other: Indian Point Energy Center
Title:
Contamination Control Part I. Description of Activity Being Reviewed (event or action, or series of actions that have the potential to affect the emergency plan or have the potential to affect the implementation of the emergency plan):
See attached revision matrix.
Part II. Emergency Plan Sections Reviewed (List all emergency plan sections that were reviewed for this activity by number and title. IF THE ACTIVITY IN ITS ENTIRETY IS AN EMERGENCY PLAN CHANGE OR EAL OR EAL BASIS CHANGE, ENTER THE SCREENING PROCESS. NO 10 CFR 50.54(q)(2) DOCUMENTATION IS REQUIRED.
Section B - Station Emergency Response Section H - Emergency Facilities and Equipment Section I
- Accident Assessment Section J - Protective Response Section K - Radiological Exposure Control Part Ill. Ability to Maintain the Emergency Plan (Answer the following questions related to impact on the ability to maintain the emergency plan):
- 1.
Do any elements of the activity change information contained in the emergency plan (procedure section 3.0[6])?
YES D NO 181 IF YES, enter screening process for that element
- 2.
Do any elements of the activity change an emergency classification Initiating Condition, Emergency Action Level (EAL), associated EAL note or associated EAL basis information or their underlying calculations or assumptions?
YES D NO 181 IF YES, enter screening process for that element
- 3.
Do any elements of the activity change the process or capability for alerting and notifying the public as described in the FEMA-approved Alert and Notification System design report?
YES D NO 181 IF YES, enter screening process for that element
- 4.
Do any elements of the activity change the Evacuation Time Estimate results or documentation?
YES D NO 181 IF YES, enter screening process for that element
- 5.
Do any elements of the activity change the Onshift Staffing Analysis results or documentation?
YES D NO 181 IF YES, enter screeninQ process for that element EN-EP-305 REV 8
ATTACHMENT 9.1 10 REVIEW 20F2 Procedure/Document Number: IP-EP-350 I Revision: 4 Equipment/Facility/Other: Indian Point Energy Center
Title:
Contamination Control Part IV. Maintaining the Emergency Plan Conclusion The questions in Part II do not represent the sum total of all conditions that may cause a change to or impact the ability to maintain the emergency plan. Originator and reviewer signatures in Part IV document that a review of all elements of the proposed change have been considered for their impact on the ability to maintain the emergency plan and their potential to change the emergency plan.
- 1.
Provide a brief conclusion that describes how the conditions as described in the emergency plan are maintained with this activity.
- 2.
Check the box below when the 10 CFA 50.54(q)(2) review completes all actions for all elements of the activity-no 10 GFR 50.54{q)(3) screening or evaluation is required for any element. Otherwise, leave the checkbox blank.
[8] I have completed a review of this activity in accordance with 10 CFR 50.54(q}(2) and determined that the effectiveness of the emergency plan is maintained. This activity does not make any changes to the emergency plan.
No further actions are required to screen cir evaluate this activity under 10 CFR 50.54(q)(3).
A review of this activity in accordance with 10 CFR 50.54(q)(2) has been completed and determined that the effectiveness of the emergency plan is maintained. This revision on the Contamination Control procedure adds guidance to provide additional assurance of implementing means of preventing the spread of contamination at the Emergency Operations Facility in the event of a radiological release during an emergency. This change does not s affect the activation and operation of the Emergency Operations Facility or the responsibility or requirements associated with operation of the facility including classification, notification, dose assessment and protective action recommendations.
The changes made to IP-EP-350 do not require a change to the Emergency Action Level scheme, On shift staffing study, or the IPEC Emergency Plan. No further actions are required to screen or evaluate this activity under 10 CFR 50.54(q)(3)
- Part V. Signatures:
Preparer Name (Print)
Dara Gray (Optional) Reviewer Name (Print) t' Reviewer Name (Print)
Timothy F. Garvey Nuclear EP Project Manager Reviewer Name (Print)
Frank J. Mitchell Manager, Emergency Planning or designee Date:
Reviewer Signature Date:
µ,t1t~
EN-EP-305 REV 8
Revision Matrix IP-EP-350 "Contamination Control" Revision 4
~~
,1 N'.?'fNrrm:::n::nsrt':~
Mtt1/4&d :W:"'
idlMt k
k
, A @ #$
- t h 111itfSl'tl'i1ZJliTJWi'iW? M Num Location Existing Condition Proposed Editorial
- Impact on 50.47 planning Std.?
ber Condition Change?
- 1.
Cover Rev 3, Effective January Rev 4, Effective July 1, 2020 Yes No - Revised text to reflect new*
Page 24,2018 revision number and effective date. This change is purely editorial and does not change the intent of the procedure, or impact any 50.47 planning standard
- 2.
Attach-Post door to warehouse, Post door to warehouse, exterior No No - Added a note to remind ment 9.5, exterior door (from door (from NEM offices) and Technician and Assessor to post Step EOF Equipment Room, as 2.1.A 1.e NEM offices) as No Equipment Room door as No Entry, appropriate when there is a Entry, No Exit, as No Exit, as appropriate.
radiological release. This would appropriate.
add to assurances of prevention of spread of contamination. It does not change the intent of the procedure, or impact any 50.47planning standard.
- 3.
Attach-NOTE: Depending on placement of No No Added a note to remind ment9.5, SOP, may also need to post the door Technician and Assessor to post Page 4 of EOF Equipment Room, as 4
to the Equipment Room as No appropriate when there is a Footnotes Entry/No Exit.
radiological release. This would add to assurances of prevention of spread of contamination. It does not change the intent of the procedure or impact any 50.47 planning standard.
Page 1
Revision Matrix IP-EP-350 "Contamination Control" Revision 4
~-z::m:r::w:;r;,... ~~
!PH
? Fil k#i/R ld!ttO*
'D'fiiW"lf"'i"fiYiiM"1'"'D'S'i'iEH".e1 Num Location Existing Condition.
Proposed Editorial Impact on 50.47 planning Std.?
ber Condition Change?
- 4.
Attach-Post door to warehouse Post door to warehouse & exteiior No No - Added a note to remind ment 9.6,
& exterior doors (from doors ( from NEM offices and Technician and Assessor to post Step 1.1.E EOF Equipment Room, as NEM offices) as NO Equipment Room) as NO ENTRY, appropriate when there is a ENTRY, NO EXIT NO EXIT radiological release. This would add to assurances of prevention of spread of contamination. It does not change the intent of the procedure, or impact any 50.47 planninci standard.
~Entergy IPEC EMERGENCY PLAN ADMINISTRATIVE PROCEDURES NON-QUALITY RELATED PROCEDURE REFERENCE USE.1 IP-EP-AD2 Page 1
Emergency Planning Document Change Checklist Form (All sections must be completed, NIA or place a check on the line where applicable)
Section 1 Doc/Procedure Type:
Administrative lmplementina f2J EPLAN 0 Doc/Procedure No:
IP-EP-350 Doc/Procedure
Title:
Contamination Control New revision number:
4 Corrective Action:
Yes f2]
No NIA O WflPC-2020-00010 CA 29 Effective date:
July 1, 2020 Section 2 Change Description
- 1.
Ensure the following are completed, or are not applicable and are so marked:
- a. 50.54q
- b.
EN-FAP-OM-023
- c.
IP-SMM-AD-102
- d.
- e.
NRG Transmittal (within 30 days)
{81
{81 NIA NIA {81 NIA N/A {81 N/A {81
- 2.
List any other documents affected by this change: N/A
- 3. Transmittals are completed: D N/A
{81 Date:6/24/2020
- 4.
Ensure the proper revision is active in eB Ref. Lib.: {81 N/A D Revision 12 of 1
- 5.
Approved doc/procedure delivered to Doc. Control for distribution: D N/A
{81 Date: 6/24/2020
- 6.
Position Binders updated: D N/A r8I Date: 7/1/2020
- 7.
Copy of EPDCC placed in EP file: N/A
{81 Date: 7/1/2020
- 8.
Supporting documentation is submitted as a general record in eB Ref. Lib.: D N/A {81 Date: 6/24/2020
- 9.
Word fries are moved from working drafts folder to current revision folder in the EP drive:
0 NIA
[gj Date: 7/1/2020 Sheet 1 of 1
1*
4' IPEC NON-QUALITY RELATED IP-EP-350 Revision 4
-=-l:,11iergy<!J EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page 1
of 25 Emergency Contamination Control Prepared by:
Dara Gray Print Name Approval:
Frank J. Mitchell Print Name Effective Date: July 1, 2020 IP-EP-350 (Cont. Control) R4.doc
&pef,.1/2Eo ib3l~P-O
!Date
~
IPEC NON-QUALITY RELATED IP-EP-350 Revision 4
'~'hr1lergy EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page 6
of 25 Table of Contents 1.0 PURPOSE................................................................................................................................................ 3
2.0 REFERENCES
.............................. *........................................................................................................... 3 3.0 DEFINITIONS........................................................................................................................................... 3 4.0 RESPONSIBILITIES................................................................................................................................. 3 5.0 DETAILS................................................................................................................................................... 3 6.0 7.0 5.1 MONITOR FOR CONTAMINATION PROCEDURE SECTION.......................................................................... 3 5.2 USE FRISKER *********************************:................................................................................................... 4 5.3 PERSONNEL CONTAMINATION.............................................................................................................. 4 5.4 VEHICLE AND EQUIPMENT CONTAMINATION.......................................................................................... 4 INTERFACES........................................................................................................................................... 4 RECORDS............................................................................................. ::................................................. 4 8.0 REQUIREMENTS AND COMMITMENT CROSS-REFERENCE.................................................... 4 9.0 ATTACHMENTS....................................................................................................................................... 4 9.1 PERSONNEL DECONTANMNATION........................................................................................................ 6 9.2 DECONTAMINATION OF VEHICLE AND EQUIPMENT OUTSIDE THE PROTECTED AREA............................... 8 9,3 OSC RAD PROTECTION TECHNICIAN CHECKLIST.......................................................... 11 9.4 OSC RAD/CHEM COORDINATOR CHECKLIST.......................................................... *....... 15 9.5 EOF RAD PROTECTION MONITOR CHECKLIST.......................................................... ;.... 21 9.6 EOF DOSE ASSESSOR CHECKLIST............................................................................... 25
e IPEC N*oN-QUALITY RELATED IP-EP-350 Revision 4
=bntergy EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page
~
Emergency Contamination Control 1.0 PURPOSE To describe the methods used for the control of radiological contamination, decontamination activities and the release of vehicles, equipment and personnel during a declared emergency.
2.0 REFERENCES
2.1 1 OCFR20.2003, "Limits for Discharge into a Sanitary Sewage System" 2.2 ENN-RP-104, "Personnel Contamination Events" 3.0 DEFINITIONS of 3.1 Clean - Contamination levels are LESS THAN 1_00 CPM above background 3.2 Low Level Contamination - Contamination levels are GREATER THAN 100 CPM above background and less than 10,000 CPM 3.3 High Level Contamination - Contamination levels are GREATER THAN 10,000 CPM above background 4.0 RESPONSIBILITIES 25 4.1 The EOF Manager is responsible for the decision to release radiologically contaminated personnel, equipment and/or vehicles from the Owner Controlled Area without being radiologically monitored when otherwise required.
' 4.2 The Radiation Protection personnel are responsible for the determination of personnel contamination levels, supervise and assist with decontamination and release of personnel as described in Attachments 9.3 and 9.5.
4.3 The Radiological As*sessment Coordinator is responsible for ensuring that 'this procedure is followed to ensure* contamination controls are established for the EOF and Security personnel working outside the Protected Area. Additional Rad Protection (OSC, other plants) may be reque_sted to support surveying the site and the monitoring of personnel and vehicles.
4.4 The OSC Rad/Chem Coordinator is responsible for the actions as described in.4.
4.5 The EOF Dose Assessor is responsible for the actions as described in.6.
5.0 DETAILS 5.1 MONITOR personnel for contamination at the following intervals:
aa IPEC NON-QUALITY RELATED IP-EP-350 Revision 4
~
El1ler.0y.
6 EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page
.4 of 25 5.1.1 When leaving areas of the plant that are suspected to be contaminated; 5.1.2 When leaving the Protected Area and portal monitors alarm; 5.1.3 When in assembly areas (if suspected to be contaminated);
5.2
. Using a frisker with a HP-210 G.M. tube or equivalent to check the individuals, determine the contamination category:
5.2.1 When contamination levels are LESS THAN 100 CPM above background, the person is considered clean 5.2.2 When contamination levels are GREATER THAN 100 CPM above background and less than 10,000 CPM, it is considered Low-Level Contamination 5.2.3 When contamination levels are GREATER THAN 10,000 CPM above background, it is considered High-Level Contamination.
5.3 MAINTAIN records of personnel monitoring on Form EP-61, Decontamination Survey Sheet if contaminated personnel are discovered.
5.3.1 Use Attachment 9.1 for Personnel Decontamination 5.4 MAINTAIN records of vehicle monitoring on Form EP-62, Vehicle Contamination Check if contaminated vehicles or equipment is discovered.
5.4.1 Use Attachment 9.2 for vehicle and equipment decontamination outside the protected area.
6.0 INTERFACES 6.1 EN-EP-609, Emergency Operations Facility 7.0 RECORDS 7.1 All forms and logs generatep during the process of identification of contamination or the decontamination of personnel, vehicles or equipment shall be maintained.
8.0 REQUIREMENTS AND COMMITMENT *cROSS-REFERENCE NL081-157-C35 9.0 ATTACHMENTS 9.1 Personnel Decontamination 9.2 Decontamination of Vehicle and Equipment Outside the Protected Area 9.3 OSC RAD Protection Technic~n Checklist
- a IPEC NON-QUALITY RELATED IP-EP-350 Revision 4
-=-Er1iergy EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE Use Page
~
of 25 9.0 ATTACHMENTS (cont.)
9.4 OSC Rad/Chem Coordinator Checklist 9.5 EOF Rad Protection Monitor Checklist 9.6 EOF Dose Assessor Checklist
e IPECSITE NON-QUALITY REL.A TED IP-EP-350 Revision 4
,:::;:-E11lergy EMERGENCY PROCEDURE PLAN IMPLEMENTING REFERENCE Use PROCEDURE.1 Personnel Decontamination Sheet 1 of 2 Page
§ of 25
- 1.0 While in the Protected Are*a PERFORM decontamination in accordance with Radiation Protection Section Procedure for "Personnel Decontamination" 1.1 Report any positive indications to the OSC Radiation Protection Coordinator in the Operations Support Center.
2.0 While outside of the Protected Area conduct decontamination at the EOF 2.1 For Low-level contamination, set up the EOF shower area in accordance with the EOF Decontamination Diagram. For High-level contamination use the decontamination equipment inside the kit located in the Offsite Monitoring Equipment closet in the EOF. Follow the instructions inside the kit. It may become necessary to get additional water or fluid to flush during decontamination. The bottle inside the kit is limited in size.
2.2 Segregate the contaminated individual to an area that has been designated with.signs, barricades as needed and Step-Off Pads 2.3 Check each piece of clothing as it is removed and segregate as to whether it is contaminated or not contaminated. Contaminated clothing should be placed in plastic bags that may be obtained from the storeroom stock.
2.4 Recheck individual after clothing is removed. IF contamination is detected record readings on Form EP-61, THEN have the individual shower and record as-found data.
2.5 Repeat if necessary to reduce contamination to less than 100 CPM above background.
2.6. IF any individuals are exposed to contamination or airborne activities, THEN consult with the Radiological Assessment Coordinator the need for radiological evaluations and monitoring (Bioassay, whole body counts, etc.)
2.7 If the individual remains. contaminated after 3 showers, consult with the Radiological Assessment Coordinator.
2.8 Provide individual with coveralls if clothing was contaminated 2.9 Report the results of decontamination to the Radiological Assessment Coordinator.
2.10 Provide all records to the Radiological Assessment Coordinator upon completion of personnel decontamination effort.
~
-=-Enlergy.r; IPEC SITE EMERGENCY PLAN IMPLEMENTING PROCEDURE File Room f Clean Exit NON-QUALITY RELATED PROCEDURE REFERENCE USE.1 Personnel Decontamination Sheet 2 of 2 EOF Decontamination Diagram I I I EOF Hallway Dirty Entrance
--: Traffic Flow IP-EP-350 Revision 4 Page z
of 25 East Parking Lot
IPECSITE EMERGENCY PLAN IMPLEMENTING PROCEDURE NON-QUALITY RELATED PROCEDURE REFERENCE USE ;2 IP-EP-350 Revision4 Page Decontam.ination of Vehicle and Equipment Outside the Protected Area Sheet 1 of 3 1.0 CHECK for removable (loose) contamination. Use survey instrument WITH either a gauze pad OR paper disks.
1.1 ESTABLISH background in the area to be less then 300 counts per minute.
1.2 USING a gauze pad, wipe the major accessible surface areas of an item.
Read background, the pad AND background again WITH the survey instrument. The contamination is LESS THAN detectable IF the reading for the pad is equal OR LESS THAN both background readings AND 300 cpm. Record the results for loose contamination on FORM EP-62.
1.3 USING a paper disk, wipe 100 cm2 of EACH representative accessible surface of an item. Read background, the disks AND background again WITH the survey instrument.
Subtract the lowest background reading from the reading for the disk. Record results GREATER THAN 100 cpm on FORM EP-62.
2.0 CHECK for fixed contamination by moving the survey instrument closely AND slowly over the accessible surfaces. Record the results for fixed contamination on FORM EP-62.
3.0 Items which DO NOT satisfy ALL the following criteria may leave the site only WITH the approved of the EOF Manager.
3.1 Loose contamination is LESS THAN detectable as *described in Section 1.0 in a background limited to 300 cpm.
3.2 Fixed contamination is LESS THAN 100 cpm as described in Section 2.0 in a background limited to 300 cpm.
4.0 POSITION the vehicle close to the corner water run-off opening. This shall allow the contamination to run off into a small depression where it shall be contained AND concentrated by the land contour.
5.0 USING hoses hooked up to the nearest water outlet, fire hydrant OR utilizing a Fire Department pumper, wash the vehicle with detergent AND water.
The detergent may be obtained from the Warehouse. Some minor scrubbing may enhance the decontamination effort. Precautions should also be taken to prevent any cross contamination of vehicles, equipment or people.
Ei1lergy~.
IPEC SITE NON-QUALITY RELATED IP-EP-350 Revision 4 EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURE REFERENCE Use Page of.2 Decontamination of Vehicle and Equipment Outside the Protected Area Sheet 2 of 3 25 5.1 IF the vehicle is still contaminated, THEN r~wash AND recheck UNTIL vehicle satisfies criteria of Section 3. Any contamination checks should be done a dry surfaces.
5.2 RECORD ALL contamination checks AND washes along with the vehicle license plate number on FORM EP-62.
Vehicles that DO NOT satisfy the criteria of Section 3 are NOT allowed to leave the site without approval of the EOF Manager.
REPORT results of vehicle checks AND decontamination to the Radiological Assessment Coordinator upon completion.
TURN-IN ALL completed FORMS to the Radiological Assessment Coordinator for filing.
t Kenney Lane
-*-*-*-~
IPECSITE EMERGENCY PLAN IMPLEMENTING PROCEDURE NON-QUALITY RELATED PROCEDURE REFERENCE Use.2 Decontamination of Vehicle and Equipment Outside the Protected Area Vehicle Decontamination Area Diagram Sheet 3 of 3 Security I I Fire C)
I Warehouse I I
Hydrant
~-T7 EOF I
Warehouse I
- Prior to Decon Vehicle Flow Path After Decon Vehicle Flow Path IP-EP-35O Revision 4 Page 10 of 25 Main Entrance
gfA IPECS ITE NON-QUALITY RELATED IP-EP-350
-::::=-Entergy EMERG ENCY PLAN PROCEDURE IMPLEM ENTING PROCE DURE REFERENCE USE Page.3 OSC Rad Protection Technician Checklist Page 1 of 4 1.0 Initial Responsibility/Activity 1.1 Assume the position of OSC Rad Protection Technician A Enter the OSC using one of the proximity Accountability Card Readers.
B. Sign in at the facility organization chart.
C. Report to and receive direction from the OSC Rad/Chem Coordinator or if not available the TSC Radiological Coordinator.
D. Verify Equipment is in calibration.
E. As directed by the OSC Rad/Chem Coordinator or the TSC Radiological Coordinator:
- 1. Perform a habitability survey of the TSC/OSC and CCR's and set up radiological controls for the TSC/OSC as shown on sheet 6 of this Checklist.
- 2. Establish the capability for monitoring of Iodine, should it become necessary.
- 3. Verify Survey Meter operability by getting a > 1 mr/hr reading with the open window using a 5µ Ci Cs -137.
source NOTE:
AMS SHALL be started during TSC/OSC activation F. Set up and operate the AMS-4 utilizing skill of the craft and procedure EN-RP-310 G. Periodically check readings of AMS-4 and ensure proper instrument operation.
- 1. IF there is a release, THEN monitor the AMS-4 to identify any increase in the radiological levels in the TSC/OSC.
Revision 4 I
11 of 25 NOTES
~
~Ei,tergy~
IPECSITE NON-QUALITY RELATED IP-EP-350 EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURE REFERENCE USE Page.3 OSC Rad Protection Technician Checklist Page 2 of 4 Revision 4 12 of 25 Initial Responsibility/Activity (cont.)
NOTES
- 2. Follow directions in Section F of this checklist to maintain AMS-4 operations.
H. Sample Count Using the MS-2/SPA-3 utilizing skill of the craft and procedure HP-9.021.
I.
Sample Count Using the E-140N OR RM-14/HP-210 utilizing skill of the craft and procedure EN-RP-302 and record results on form EP-16.
J. Perform background and source checks approximately every hour OR as specified by the Rad/Chem Coordinator or TSC Radiological Coordinator (frequency may be adjusted, either more or less often, in consideration of current radiological conditions).
K. Using the readings from the AMS-4 Monitor and the noble gas-to-iodine ratio from Chemistry, determine the iodine activity.
- 1. IF iodine activity is determined to be greater than 1X10-7 micro curies/cubic centimeter by any of the above methods, THEN notify the OSC Rad/Chem or the TSC Radiological Coordinator.
L. Establish contamination controls for the TSC/OSC if necessary.
2.0 Continuous Responsibility/Activity 2.1 Establish and Maintain radiological controls A As directed by the OSC Rad/Chem Coordinator or the TSC Radiological Coordinator, perform periodic radiological monitoring particularly when a release of radioactive material into plant environments is in progress or suspected.
~
~E,1lergy IPECSITE NON-QUALITY RELATED IP-EP-350 EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURE REFERENCE USE Page.3 OSC Rad Protection Technician Checklist Page 3 of 4 Revision 4 13 of 25 Continuous Responsibility/Activity {cont.)
NOTES 2.2 2.3 B. This should be done approximately once every 60 minutes or when conditions have likely worsened or when directed to by the OSC Rad/Chem Coordinator or the TSC Radiological Coordinator.
Inform the OSC Rad/Chem Coordinator or another coordinator when temporarily leaving the work area.
A. IF you are leaving the TSC/OSC Complex (the restroom is within complex) THEN:
- 1. Inform the Work Control Coordinator and/or OSC Log-Keeper (for accountability purposes)
- 2. Inform the Work Control Coordinator and/or OSC Log-Keeper when you return.
B. Upon return, obtain a briefing from the OSC Rad/Chem or the TSC Radiological Coordinator on any events, which have occurred while away.
Escort as directed, any team being sent into an area where any of the following conditions exist:
A. Radiological conditions are unknown. Surveys or ARMs may be used to predict radiological conditions.
B. Radiation fields in" excess of 1 R/hr are expected.
C. In the event of any release of radioactivity to the environment.
2.4 Assist with the decontamination efforts of personnel, equipment, and onsite areas as appropriate.
3.0 Closeout Responsibility/Activity 3.1 IF radiological conditions allow, THEN as directed by the Radiological Coordinator:
A. Return emergency equipment to proper storage areas and restock supplies as needed.
~
~E*n1ergy IPEC SITE NON-QUALITY RELATED IP-EP-350 Revision 4 A
__ _..~
A A
EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURE REFERENCE Use Page.3 OSC Rad Protection Technician Checklist Page 4 of 4
/'
C
/
ol B
- ... I,
- 1.
/
E N
osc R
C
-E TSC p
M I
' i' J "-..
/
Computer Room
/
TSC/OSC Access Points to be posted:
14 If Hallway Contamination< 1000 dpm/ 100 sq. cm
- If Hallway Contamination> 1000 dprn/ 100 sq. cm A. Entry/Exit A. No Entry. Exit Only B. No Entry/No Exit B. Entry to TSC/OSC. No Exit. White Step Off Pad and Frisk Shoes before stepping here C. No Entry/No Exit C. No Entry/No Exit of D. Equipment cabinets. Place sign at top of stairway D. Equipment cabinets. Place sign at top of stairway.
No Eritry/No Exit without permission from RAD Coordinator.
E. Air Monitoring Equipment No Entry/No Exit without permission from RAD Coordinator E. Air Monitoring Equipment 25
~ Ei,lergy."
IPECSITE NON-QUALITY RELATED IP-EP-350 EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURE REFERENCE Use.4 OSC Rad/Chem Coordinator Checklist Page 1 of 6 1.0 Initial Responsibility/Activity A Determine if any personnel are currently in the field as follows:
Entergy-lPEC web site Applications drop down menu Sentinel Fleet Production Reports Indian Point RCA Currently Logged In If not in Crystal Report printable PDF format, then convert to such and PRINT B. Obtain a copy of current employee exposure for use in ALARA considerations when assigning OSC team members as follows:
Use Item 2 instructions above for Sentinel acc~ss Select Daily Margin List by Department Page Select the key departments needed (e.g., Operations, RP, Rad-waste, Chem., FIN, MNTS, Mech-1, Security)
Drop Down Menu Select Last Name, OK If not in Crystal Report printable PDF format, convert to such and PRINT
- c. Request the Control Room to align the oscrrsc ventilation system for incident operation per procedure, if required.
D. IF necessary THEN direct a Rad Protection Technician to perform a habitability survey of the OSC/fSC and Control Rooms and verify that radiological controls are set up as shown on Sheet 6 of this Checklist for the TSC/OSC.
Revision 4 15 of 25 NOTES
~
IPECSITE NON-QUALITY RELATED IP-EP-350
~Entergy..,
EMERGENCY PLAN PROCEDURE*
IMPLEMENTING PROCEDURE REFERENCE USE.4 OSC Rad/Chem Coordinator Checklist Page 2 of 6 Initial Responsibility/Activity (cont.}
Page E. Establish the capability for monitoring of Iodine, should it become necessary. Have a Rad Protection Tech set up the AMS-4.
F. Establish Habitability and Contamination controls for the CR if necessary. At a minimum verify habitability in the Control Rooms and TSC/OSC and re-verify approximately every 60 minutes or when conditions have likely worsened.
NOTE:
Ensure' Habitability and Contamination Controls are implemented when a Radiological Release occurs G. IF dosimetry is necessary and individuals have not been previously issued dosimetry THEN assign a person(s) to go to HP-1 or HP-3 as appropriate to obtain dosimetry (DRD's/DLR's) to be issued to them, H. Assign Personnel to the following positions:
- 1. OSC/TSC Rad Protection Monitor
- 2. Protected Area Monitoring Team, IF requested by the
- EOF,
- 4. Rad Waste Personnel to report to the EOF to support any decontamination efforts, IF requested by the EOF.
- 5. RP Monitor to Assembly Areas to verify habitability if a radiological release has occurred. Monitor will need to bring frisker and survey meter. '
- 6. Chemistry Technicians to take samples and report results as requested.
I.
Obtain keys from Unit 2 control point for the lock box on the side of the OSC radiological equipment supply lockers. Check all instruments for operability and inventory any locker which has a broken seal.
Revision 4 16 of 25 NOTES
a&
IPEC SITE NON-QUALITY RELATED IP-EP-350
=E
-=-
1lllergy~
EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURE REFERENCE USE.4 OSC Rad/Chem Coordinator Checklist Page 3 of 6 Initial Responsibility/Activity (cont.)
J. Obtain requested Chemistry sample, and report the results to the OSC Manager.
2.0 Continuous Responsibility/Activity Page 2.1 Direct Radiation Protection and Chemistry Technicians in the following activities:
A. Assign qualified RP/Chemistry Technicians to conduct emergency response support activities.
B. Use Emergency Team Briefing Form (EP-38) to prepare and document team assignments. Ensure each team dispatched has a copy of the Emergency Team Briefing Form.
C. Assign personnel to conduct in-plant radiological surveys and take chemistry samples as required supporting ERO activities.
D. Assign RP Technicians to accompany Teams requiring radiological support.
E. Prepare or have prepared the ERWP (EP-40). Review and approve the prepared form and then use or have it used.
F. Participate in Team briefings to ensure team members properly understand the assigned task. Briefings SHOULD be clear, concise, accurate, and prompt based upon the hazard(s) to be encountered.
G. Use the ERWP (Form EP-40) to discuss dose limits, surveys to be performed, expected and maximum dose rates and stay times. Advise team members to immediately contact or return to the OSC when dose rates or stay times approach the e$tablished limits.
H. Discuss dosimetry requirements. Coordinate with Radiological Coordinator any radiation exposure limit extensions necessary.
Revision 4 17 of 25 NOTES
IPECSITE EMERGENCY PLAN IMPLEMENTING PROCEDURE NaN-QUALITY RELATEp PROCEDURE IP-EP-350 REFERENCE USE.4 OSC Rad/Chem Coordinator Checklist Page 4 of 6 Continuous Responsibility/Activity (cont.)
I.
Discuss protective clothing and respiratory protection requirements.
- J. Discuss travel route requirements and if there are any releases in progress.
K. Advise team members on monitoring and decontamination procedures following mission completion.
L. Advise team how they will be notified of changing conditions or classifications. Direct radiological. control personnel to read dosimetry for personnel whose exposure limits are approached Page M. Participate in OSC team post job debriefings, if needed.
N. Maintain communication capability (i.e. phone, radio) and work with the Work Control Coordinator while the team is in the field to answer any questions that may arise concerning the task.
- 0. Assist the OSC Manager in planning and preparing for any Radiological or Chemistry work activities needed to return the plant to a safe condition.
P. Verify the Work Control Coordinator is tracking individual exposure data in WebEOC or Individual Exposure Tracking Log (Form EP-29).
Q. RP Tech escorts are required for any team being sent into an area where any of the following conditions exist:
- 1. Radiological conditions are unknown. Surveys or ARMs may be used to predict radiological conditions.
- 2. Radiation field in excess of 1 R/hr are expected.
- 3. In the event of any release of radioactivity to the environment.
Revision 4 18 of 25 NOTES
~
IPECSITE NON-QUALITY RELATED IP-EP-350,
~Entergy EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURE REFERENCE USE.4 OSC Rad/Chem Coordinator Checklist Page 5 of 6 Continuous ResponsibUity/Activitv (cont.)
R. Coordinate with the OSC Manager for tasks involving injured personnel or search and rescue activities.
Page
- 1. IF potentially contaminated or highly exposed personnel require offsite medical facility attention, THEN support transport with Operations and Security.
S. Frequently brief the OSC Manager on assigned task status and the results reported by RP and Chemistry Technicians T. Maintain an adequate reserve of personnel in the OSC RP/Chem pool by requesting additional resources from
. the Radiological Coordinator as necessary.
U. Request the Radiological Coordinator to coordinate with the EOF Administration and Logistics Coordinator to obtain equipment and materials not available onsite or through previously arranged agreements.
V. Direct decontamination of personnel, equipment and areas inside the Protected Area.
W. If respirators are needed they can be obtained at the normal issue point location.
2.2 IF there are contaminated injured personnel THEN perform the following:
A. Provide radiological support for the assessment, treatment, and transportation of contaminated injured personnel.*
B. Monitor patients on-site for contamination and decontaminate as appropriate. (IP-EP-350, Emergency Contamination Control)
Revision 4 19 of 25
- NOTES
~
IPECSITE NON-QUALITY RELATED IP-EP-350 Revision 4
.-d'Elllergy EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURE REFERENCE USE.4 OSC Rad/Chem Coordinator Checklist Page 6 of 6 A
C
~
A J ~
B 1 D
- .. I *-.,.
I -
E N
osc R
C E
TSC p
1
- M i'.
i---
A_,
/
Computer Room A
TSC/OSC Access Points to be posted:
Page 20 If Hallway Contamination< 1000 dpm/ 100 sq, cm cm A, Entry/Exit If Hallway Contamination > 1000 dpm/ 100 sq, A No Entry, Exit Only of B. No Entry/No Exit B, Entry to TSC/OSC. No Exit. White Step Off Pad and Frisk Shoes before stepping here C, No Entry/No Exit D, Equipment cabinets. Place sign at top of stairway No Entry/No Exit without permission from RAD Coordinator.
E, Air Monitoring Equipment C, No Entry/No Exit D, Equipment cabinets, Place sign at top of stairway.
No Entry/No Exit without permission from RAD Coordinator E. Air Monitoring Equipment 25
~
IPEC SITE NON-QUALITY RELATED IP-EP-350 g;iEnlergy't, EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURE REFERENCE USE.5 EOF Rad Protection Monitor Checklist Page 1 of 4 Page 1.0 Initial Responsibility/Activity 1.1 Assume the position of EOF Rad Protection Monitor A. Sign in on the EOF Check Point Sign-In Log (Form EP ALW.
B. Report to and receive direction from the EOF Radiological Assessment Coordinator.
C. Verify Equipment is in calibration.
D. As directed by the EOF Dose assessor or the EOF Radiological Assessment.Coordinator.
- 1. Perform a habitability survey of the EOF and ICP and set up radiological controls as shown on sheet 4 of this Checklist.
- 2. Establish the capability for monitoring of Iodine, should it become necessary.
NOTE AMS SHALL be started during EOF activation E. Set up and operate the AMS-4 utilizing skill of the craft and procedure EN-RP-310.
F. Periodically check readings of AMS-4 and ensure proper instrument operation.
- 1. IF there is a release, THEN monitor the AMS-4 to identify any increase in the radiological levels in the EOF.
- 2. Follow directions in Section E of this checklist to maintain AMS-4 operations.
G. Sample Count Using the MS-2/SPA-3 utilizing skill of the craft and procedure HP-9.021.
H. Sample Count Using the Model 177 OR RM-14/HP-210 utilizing skill of the craft and procedure EN-RP-302 and record results on form EP-16.
Revision 4 21 of 25 NOTES
-~
IPEC SITE NON-QUALITY RELATED IP-EP-350
=Ei1lergy EMERGENCY PLAN PROCEDURE 2.0 2.1 IMPLEMENTING PROCEDURE REFERENCE USE Page.5 EOF Rad Protection Monitor Checklist Page 2 of 4 Initial Responsibility/Activity (cont.)
I.
Perform background and source checks approximately every hour OR as specified by the Radiological Assessment Coordinator or Dose Assessor (frequency may be adjusted, either more or less often, in consideration of current radiological conditions).
J. Using the readings from the AMS-4 Monitor and the noble gas-to-iodine ratio from Chemistry, determine the iodine activity.
- 1. IF iodine activity is determined to be greater than 1X10-7 micro curies/cubic centimeter by any of the above methods, THEN notify the E0F Dose Assessor or the E0F Radiological Assessment Coordinator.
K. If directed by the E0F Radiological Assessment Coordinator or Dose Assessor then conduct decontamination of vehicles and personnel using IP-EP-350.
Continuous Responsibility/Activity Establish and Maintain radiologocal habitability A. As directed by the E0F Dose Assessor or the EOF Radiological Assessment Coordinator, perform periodic radiological monitoring particularly when a release of radioactive material into plant environments is in progress or suspected Revision 4 22 of 25 NOTES
ta IPEC SITE NON-QUALITY RELATED IP-EP-350
~Entergy EMERGENCY PLAN PROCEDURE 2.2 IMPLEMENTING PROCEDURE REFERENCE USE.5 EOF Rad Protection Monitor Checklist Page 3 of 4 Continuous Responsibility/Activity (cont.)
- 1. If there has been a Radiological Release outside of the Protected Area then set up the EOF as follows when directed by the Dose Assessor:
Page
- a. Set up stanchions, rope barricades and friskers at both ends of the main hallway.
- b. Set Frisker alarm to (2) times background.
- c. Set up SOP's at both entrances.
- d. Place a waste receptacle near the SOP location.
- e. Post door to warehouse, exterior door (from NEM offices) and Equipment Room door as No Entry, No Exit, as appropriate.
B. Periodically verify habitability in the EOF. This should be done approximately once every 60 minutes or when conditions have likely worsened or when directed to by the EOF Dose Assessor or the EOF Radiological Assessment Coordinator; Inform the EOF Radiological Assessment Coordinator when temporarily leaving the work area.
A. IF you are leaving the EOF Complex (the restroom is within complex) THEN:
- 1. Inform the EOF Radiological Assessment Coordinator (for accountability purposes)
- 2. Inform the EOF Radiological Assessment Coordinator when you return.
B. Upon return, obtain a briefing from the EOF Dose Assessor or the EOF Radiological Assessment Coordinator on any events, which have occurred while away.
2.3 Assist with the decontamination efforts of personnel, equipment and onsite areas as appropriate.
R evision 4 23 of 25 NOTES
.a.
g, Elllergy.s, A
IPECSITE NON-QUALITY RELATED IP-EP-350 EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURE REFERENCE USE.5 EOF Rad Protection Monitor Checklist Page 4 of 4 Eplan office ICP Main Room 0
ICP Briefing Room Page Revision 4 24 of 25 Locker Room Bathroom B
If there is indication of contamination outside of the PA then the EOF Complex may be set up to restrict access as outlined above:
If Hallway contamination <1000 dpm/100cm2 A - No Entry/ No Exit. Note: this may also include one or two doors to the EOF Equipment Room, as appropriate.
B - Entry/ Exit to EOF Complex. Set up white SOP, with Frisker and trash receptacle available.
NOTE: Depending on placement of SOP, may also need to post the door to the Equipment Room as No Entry/No Exit.
IPEC SITE NON-QUALITY RELATED IP-EP-350
~El fl ergy EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURE REFERENCE USE.6 EOF Dose Assessor Checklist Page 1 of 1 Page 1.0 Initial Responsibility/Activity 1.1 Confer with the Radiological Assessment Coordinator on the need to set up EOF Radiological Controls. If needed request a Radiation Protection Technician from the OSC. Have the Radiation Protection Tech set up the EOF hallway as follows:
A. Set up stanchions, rope barricades, and friskers at both ends of the main hallway.
B. Set frisker alarm to two (2) times background.
C. Set up Step off Pads (SOPs) at both entrances.
D. Place a waste receptacle near the SOP location.
E. Post door to warehouse & exterior doors (from NEM offices and Equipment Room) as NO ENTRY, NO EXIT.
Revision 4 25 of 25 NOTES