BECO-84-174, Informs That No Addl Info Will Be Submitted in Response to IE Bulletin 83-02.Util to Denton, Response to IGSCC Insp Order Confirming Shutdown Addresses All Applicable Items

From kanterella
(Redirected from BECO-84-174)
Jump to navigation Jump to search
Informs That No Addl Info Will Be Submitted in Response to IE Bulletin 83-02.Util to Denton, Response to IGSCC Insp Order Confirming Shutdown Addresses All Applicable Items
ML20107M749
Person / Time
Site: Pilgrim
Issue date: 10/15/1984
From: Harrington W
BOSTON EDISON CO.
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
BECO-84-174, IEB-83-02, IEB-83-2, NUDOCS 8411140249
Download: ML20107M749 (2)


Text

-

, ,% e BOSTON EDIBON COMPANY S00 BOYL5TO N STREET BOSTON. M ASSACHUSETTs 02199 WILLIAM D. HARRtNGTO N October 15, 1984 BECo 84- 174 Dr. Thomas E. Murley Regional Administrator Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 License No. DPR-35 Docket No. 50-293

References:

1) IE Bulletin 83-02: Stress Corrosion Cracking in Large Diameter Stainless Steel Recirculation System Piping at BWR plants
2) USNRC letter (Vassallo to Harrington), dated August 26, 1983 with enclosure "IGSCC Inspection Order Confirming Shutdown"
3) BECo Letter No.84-146, dated September 11, 1984, Harrington to Denton, " Response to IGSCC Inspection Order confirming Shutdown"

Dear Sir:

This letter is being submitted in response to IE Bulletin 83-02 (Reference 1) which directed Boston Edison Company (BECo) to perform ISI of large diameter stainless steel recirculation system piping and submit the results and l

corrective actions to the NRC. The IGSCC Inspection Order confirming shutdown (Reference 2) required that a report be submitted to the NRC of the results of mandated inspections and corrective actions taken at Pilgrim Nuclear Power

Station. By Reference 3, BECo has submitted a report to the NRC documenting the results of ISI and corrective actions taken at PNPS. This previously submitted report addresses the response to all applicable items of IE Bulletin t 83-02. Therefore, no additional infortnation will be submitted in response to l Bulletin 83-02.

i l

8411140249 841015 PDR 0 ADOCK 05000293 PDR 3 P l

. i

/ E //

I p;. ,c_. ,

BO STON EDCON COMPANY Dr. Thomas E. Murley Regional Administrator October 15, 1984 Page 2 Should you have any questions concerning this response, pletse contact us.

Very truly yours, WGL/ns c

Commonwealth of Massachusetts)

County of Suffolk )

Then personally appeared before me W. D. Harrington, who, being duly sworn, did state that he is Senior Vice President - Nuclear of the Boston Edisun Company, the applicant herein, and that he is duly authorized to execute and file the submittal contained herein in the name and on behalf of the Boston Edison Company and that the statements in said submittal are true to the best of his knowledge andlb'elief. . -

My Commission expires: g @ yf fggg duJ[/U (X)

Notary ublic