TXX-4973, Forwards Rev 0 to Comanche Peak Response Team Results Rept:Isap III.a.4,Traceability of Test Equipment. Repts Will Be Issued on Periodic Basis

From kanterella
Revision as of 09:40, 9 July 2023 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Rev 0 to Comanche Peak Response Team Results Rept:Isap III.a.4,Traceability of Test Equipment. Repts Will Be Issued on Periodic Basis
ML20214K652
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 08/19/1986
From: Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Noonan V
Office of Nuclear Reactor Regulation
Shared Package
ML20214K654 List:
References
CPRT-611, TXX-4973, NUDOCS 8608220012
Download: ML20214K652 (2)


Text

?

-CPRT-611, Log # TXX-4973

. File # 10068 TEXAS UTILITIES GENERATING COMPANY SKYWAY TOWER . 400 NORTH OLIVE STREET. L.B. 81. DALLAS. TEXAS 78301 August 19, 1986

, JA%7Af?Jn2 l

Director of Nuclear Reactor Regulation Attn: Vince S. Noonan, Director

, Comanche Peak Project Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C. 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 CPRT RESULTS REPORT

Dear Mr. Noonan:

We transmit herewith the SRT approved Result Report listed below. The files which contain supporting documentation for the Result Report have been reproduced in their entirety and are available for public inspection in our Dallas office. Anyone wishing to inspect these files should contact Ms. Susan Palmer (214/979-8242).

III.a.4 Traceability of Test Equipment We shall issue future Result Reports on a periodic basis as they are approved by the CPRT Senior Review Team.

Very truly yours, W. G. Counsil

> WGC/grr Enclosure 90

' I 8608220012 860819

[DR ADOCK 05000445 PDR A DEVIS10N OF TEXAS EJTil2 TIES ELECTRIC COMPANY

[ J q CPRT-616- Log # TUS-4904 File # 10068 TEXAS UTILITIES GENERATING COMPANY MKYWAY TOWER

  • 400 NORTH OLIVE HTREET, L.R. 81
  • DALLAN, TEXAM 73201 August 19, 1986

'L","Z.2?5*

MEMORANDUM TO: Mr. W. G. Counsil

SUBJECT:

CPRT RESULTS REPORT We transmit herewith the~ SRT approved Results Report listed below. The files which contain supporting documentation for this Results Report have been reproduced and are available in the Dallas file room for public inspection.

III.a.4 Traceability of Test Equipment v./Lc j

. John W. Beck Chairman, CPRT Senior Review Team JWB:grr Enclosure cc: CPRT File i

1 l

l A DIVINEON OF TEXAN UTILITREN ELECTRIC COMPANY