Discusses Review of 730924 Application & 731017 Suppl Re Retirement Program for Facility.Plans Generally Satisfactory in Concept & Scope.Analysis,Demonstrating Adequate Storage, Security & Monitoring Precautions,Needed
ML20210E067
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 11/30/1973
From: Skovholt D
US ATOMIC ENERGY COMMISSION (AEC)
To: Alexanderson E
POWER REACTOR DEVELOPMENT CO.
Shared Package
ML20210D960 List:
References
NUDOCS 8609220095
Download: ML20210E067 (1)


Text

_ _ _-

_ - ~ . . _ _ - ,

1 -; -

EXH7.BI'l' (,6 .

uanTro shirs ,.

2.hl / ATOMIC ENERGY COMMISSION Gk

{

hL,L7 e m . vo . a:c. e lE

, , , , *, g. t. M *XANLCR$0N Novaaber 3'0 ,1973 i l Dockst No. 50-16 ONb G EM &.a% M N Power Re. actor Developy,ent Con aisp (

ATri: Mr. Fidou Alexsodersco Genetral Manager Post Office Box 725 Monroe, M.ichigan 48161 Centlemen:

By application dated Septsaber 2fe,1973, and supplement dated Octo'ber 17, 1973, you provided an updato and expansion of the retires.cnt program for the Farmi-1 facility. You requested ou.r cencurrence $.n the concept and scope of the retirement plans.

We havs now completed our revive of 'ycur application and havs . determined I that your plans are generally eatisfectcry in cencept and secpe and that you may continue retiremeat actitricies within botuidaries and conditions established by Licesse No. DPR*9 and approved technical specificatior.s>

Although we continue to believe that permanent or long-tern etorage of

he sodium and blanket material onsite is not .acueptable, we woul:1 not '

categorically rule out retrievable onsite storagis for es.veral' years, ao l described in your Octcher 17 letter, to facilitate eventumi disposal 4

( provided it is shoin that such storage does not adversaly affec*. the public interest. PRLC meat, hovsver, provide an ar.alysis that desonscree.&s l that adequate stor*Be, escurf.ty, and m2nitoring precautions will be esta'b1Lished 4 l

by procedures and technical specifications. '

n Sincerely.

4 ,, fl // -

nald J. r.avholt l Assistant Director for Operatins Reactors Directorate of LicensinD l cc:/ Cavid E. McGiffert, Esquire l Covington & Burijng l 888-- 16th Strent, N. W.

Washington, D. C. 10006 4.38 R

e609220095e609'g.5 6 l PDR ADOCK C500 N