ML19308D32830 June 1977RO-77-58:on 770607,operability of Motor Driven Emergency Feedwater Pump Flow Path Found Not Verified within Time Limit.Caused by Error in Evaluation of Performed SP-349. Shift Supervisors Instructed Re Sp Requirements
ML19308D33113 July 1977RO-77-66:on 770620,SP-344 for Nuclear Svcs Closed Cycle Cooling Sys Operability Not Performed within Required Time Frame.Caused by Schedule Change.New Surveillance Schedule Written
ML19308D33619 July 1977RO 77-69E:on 770630-0701,fish Impingement on Intake Screens Exceeded Tech Specs Levels.Caused by Dredge Performing Canal Maint
ML19308D34315 July 1977RO-77-68:on 770624,reactor Coolant Letdown Not Sampled for Dose Equivalent I-131.Caused by Personnel Error.Time Frequency Info Posted
ML19308D35412 April 1977RO-77-26:on 770322,makeup Valve Failed to Open on Manual Hpis Initiation,Contrary to Tech Spec Requirement.Caused by Torque Switch Set Too Low for Consistent Opening of Valve. Torque Switch Reset to Higher Valve
ML19308D3673 June 1977RO-77-47:on 770513,regulating Rods,Group 7,out of Specified Limits.Caused by Gate Drive Relay Design Error.Relay Modified
ML19308D3793 June 1977RO-77-46:on 770514,hydraulic Snubber MUH-44 Found Inoperable.Caused by Missing Cotter pin.MUH-44 Renewed W/ Functionally Tested Spare Snubber & SP-201 Revealed Other Snubbers Operable
ML19308D39318 May 1977Forwards RO-77-44
ML19308D39518 May 1977RO-77-44:on 770427,regulating Rod Insertion Limits Exceeded. Caused by Xenon Buildup & Group 7 Being Fully Inserted. Personnel Instructed to Monitor Rod Index Limits More Closely
ML19308D42417 May 1977RO-77-43:on 770427,regulatory Rods Group 7 Found Out of Specified Limits.Caused by Grounded Connector Shield in 24 Volt Programmer.Connector Repaired & Further Investigation Underway
ML19308D42917 May 1977RO-77-42:on 770425,monthly Functional Tests Not Performed within Time Frame.Caused by Undistributed Change to Master Surveillance Plan SP-443.Surveillance Schedules Double Checked & Sp Procedural Changes to Be Handled in Timely Way
ML19308D43317 May 1977RO-77-41:on 770424,primary Containment Average Air Temp Exceeded 130 F.Caused by Closure of Nuclear Svcs Closed Cycle Cooling Valve SWV-151.Personnel Cautioned Re Unauthorized Manipulation of Valves
ML19308D4342 August 1977RO 77-77:on 770907,while in Mode 1,chemical Addition Pumps 3A & 3B Found Inoperable.Pumps Believed to Be Airbound.Vent Valves Installed to Preclude RecurrenceBoric Acid
ML19308D4359 August 1977RO-77-90:on 770715,decay Heat Valve DHV-4 Failed to Open from Control Room During Quarterly Valve Cycling.Cause Not Determined.Corrective Action Will Be Initiated After Engineering Evaluation
ML19308D43610 August 1977RO-77-91:on 770717,reactor Coolant Dose Equivalent I-131 Level Found Contrary to Tech Specs.Caused by Expected Spikes Following Reactor Trip & Known Leaking Fuel Pins.Reactor Coolant Cleaned Via DemineralizersPower change
ML19308D43711 August 1977RO-77-92:on 770717,steam Driven Emergency Pump EFP-2 Experienced Overspeed Trip on Autostart.Caused by Condensation in Steam Supply Preventing Fast Throttle Valve Closing.Drain Sys Modified & Steam Bypass InstalledOverspeed trip
ML19308D46112 September 1977RO-77-105E:on 770901,reactor Bldg Purged Unmonitored Contrary to Ets.Caused by Failure to Ascertain Monitor Operability Prior to Purge Initiation.More Stringent Procedure Adherence Will Be Followed
ML19308D46612 August 1977RO 77-93E:on 770729,probable Unplanned Radioactive Gas Release to Auxiliary Bldg Occurred.Caused by Blown Loop Seal on Waste Evaporator.Loop Seal re-established on Each OccurrenceLoop seal
ML19308D4709 August 1977RO-77-89:on 770715,valve DHV-41 Failed to Open from Control Room During Cycling Surveillance Procedure.Caused by Shift in Torque Switch Setting.Torque Switch Contacts Burnished & Switch Reset
ML19308D4717 November 1977RO-77-133E:on 770930-1007,air Inhalation Sample Station C41 Gross Beta Activity Exceeded Control Station Activity.Caused Control Station Activity.Caused by Fallout Due to 770919 Nuclear Weapons Test by Peoples Republic of China
ML19308D4758 November 1977RO-77-134E:on 770101-0930,incorrect Procedure Used for Environ Sample Analysis.Caused by Inadequate Procedures, Techniques & Equipment.Procedures Being Revised to Allow Longer Count Times
ML19308D4798 August 1977RO-77-88:on 770715,containment Isolation Valve SWV-47 Failed to Close During Quarterly Cycling Procedure SP-370.Caused by Loose Control Wire Connection to Limit Switch.Connection Tightened & Valve Restored to Operable Condition
ML19308D4807 December 1977RO-77-141E:on 770101-1031,environ Samples LLDs Exceeded ETS Requirements.Possibly Caused by Natural Activity in Sample.Analysis Procedures Being Revised Enlarging Sample Size & Counting Time
ML19308D48613 September 1977RO-77-106E:on 770830,facility Site Load Found Below 70% Level Specified in Ets.Caused by Reduced Sys Load at Night Coupled W/Necessity of Keeping Other Power Stations in Sys at Base Load
ML19308D48819 May 1977RO 77-45E:on 770428-29,fish Impingement on Intake Screens Exceeded Tech Specs Limits.Cause Unknown
ML19308D4898 August 1977RO-77-87:on 770715,containment Isolation Valve WDV-94 Failed to Operate During Quarterly Cycling Procedure SP-370. Caused by Dirty Limit Switch Contacts.Contacts Cleaned & WDV-94 Operability Restored
ML19308D5178 August 1977RO-77-85:on 770715,methyl Iodine Removal Efficiency Found Below Tech Specs Requirements During Reactor Bldg Charcoal Filter Bank Testing.Caused by Deteriorated Charcoal Due to Site Flue Gases & Air Pollutants.Charcoal Replaced 770806
ML19308D52228 April 1977RO-77-32:on 770404,while Reducing Power for Maint,Rod 6 of Group 7 Failed to Move.Caused by Control Rod Drive Mechanism Blown Fuse Due to Control Stator Failure.Stator & Fuse Renewed
ML19308D52725 April 1977RO 77-31E:on 770330-31,fish Impingement on Intake Screens Exceeded Tech Specs Limits.Caused by Barge Traffic
ML19308D52828 April 1977RO-77-33:on 770406,absolute Position Indicator for Rod 5, Group 8 Failed.Caused by Amphenol Connector Faulty Pin Connection.Connector Repaired & Indicator Restored to Operation
ML19308D55027 April 1977RO-77-34:on 770406,Rod 3,Group 2 Dropped Into Core & Quadrant Power Tilt Steady & Transient Limits Exceeded. Caused by Central Rod Drive Mechanism Stator Failure.Stator to Be Renewed
ML19308D55229 July 1977RO-77-76:on 770707,auxiliary Bldg Exhaust Fan AHF-14D Failed to Restart After Charcoal Filter Sampling.Caused by AHF-14D Low Flow Switch Shifting Calibr.Switch Calibr & Fan Operability Restored
ML19308D55728 July 1977RO-77-75:on 770702,absolute Position Indication for All Regulating Rods Lost While Performing Operability Test on Rod 3 Group 6.Caused by Crowbarred 15 Volt Power Supply Due to Spike of Unknown Origin.Sys Restored
ML19308D57622 July 1977RO-77-71:on 770629,absolute Position Indication for Regulating Rod 3 Group 6 Declared Inoperable.Caused by Absolute Position Indicator Tube Failure.Tube Renewed, Aligned & Operability Restored
ML19308E00514 June 1977RO 77-49E:on 770606,unplanned Radwaste Gas Release Occurred During Makeup Tank Venting.Caused by Waste Gas Decay Tank Blown Loop Seal,Connected to Waste Gas Low Pressure Header. Seals re-established & Their Surveillance IncreasedLoop seal
ML19308E11819 April 1977RO 77-30E:on 770324-25,biomass of Fish & Shellfish Impinged on Units 1,2 & 3 Intake Screens Exceeding ETS Reporting Level.Possibly Caused by Barge Traffic,Strong Winds & Divers Cleaning Intake Structure
ML19308E12511 April 1977RO 77-28E:on 770318-19,biomass of Fish & Shellfish Impinged on Units 1,2 & 3 Intake Screens Exceeding ETS Reporting Level.Event Normal or Seasonal
ML19312D51721 March 1980Supplemental RO 80-014/04L-0:on 800221,single Measured Value of Radioactivity Concentration in Critical Pathway Environ Medium Samples Exceeded Control Station Value.Caused by Coal Slag Pile.Pile Relocation Study Underway
ML19317G1725 August 1977RO-77-82:on 770712,radiation Monitoring Instrumentation Functional Test SP-335 Time Exceeded Tech Spec Specified Limits.Surveillance Schedule Amended to Meet ASME Section XI Requirements & SP-335 Completed
ML19317G1835 August 1977Corrected RO-77-83:on 770712,level a Channel Removed from Svc Due to Disagreement Between a & B Level Channels.Caused by Level Indication Transmitter Calibr Shift.Instrument Calibr & Channel Operability Restored
ML19317G1865 August 1977RO-77-83:on 770712,level a Channel Removed from Svc Due to Disagreement Between a & B Level Channels.Caused by Level Indication Transmitter Calibr Shift.Instrument Calibr & Channel Operability Restored
ML19317G1895 August 1977RO-77-84:on 770713,discovered That Unit 3 Not Notified of 770706 Unit 1 & 2 Failure.Caused by Personnel Error.Tests Not Meeting Acceptance Criteria Constitute Inoperability. Personnel Instructed in Tech Spec Requirement Procedures
ML19317G1928 August 1977RO-77-86:on 770712,SP-511 Acceptance Criteria Not Met by Unit 1 & 2 Batteries While in Mode 1 Operation.Caused by Recording Specific Gravity Prior to Battery Stabilization After Electrolyte Addition
ML19317G2054 August 1977RO 77-81E:on 770712,discharge Point Temp Exceeded Tech Spec Limits for More than 3-h.Caused by High Intake Temp & High Power Level.Incident Revealed During 770727 Environ Data Review.Temp Increase Notification Requires Prompt Action
ML19317G2133 August 1977RO 77-80E:on 770727,unplanned Radioactive Gas Released to Auxiliary Bldg While in Mode 1 Operation.Caused by Concentrated Waste Storage Tank Blown Loop Seals.Loop Seals re-established & Storage Tank Surveillance IncreasedLoop seal
ML19317G2213 August 1977RO-77-79:on 770708,1 & 4 Vol % Hydrogen Balance Nitrogen Failed to Meet Tech Spec Acceptance Criteria During Gas Chromatograph Calibr.Caused by Separation Column Resolution Loss.Replacement Column Will Be Maintained
ML19317G2273 August 1977RO-77-78:on 770711,greater than 15% Per Hour Power Change Completed W/O DE-I 131 Analysis.Caused by Procedural Inadequacy.Operating Procedure Changes Initiated to Ensure Prompt NotificationPower change
ML19317G30213 May 1977RO 77-40E:on 770421,fish Impingement Sampling Stopped by Clogged Collecting Devices.Caused by Large Accumulation of Ctenophores in Baskets.Effective Filtering Area of Collecting Baskets Increased
ML19317G3105 May 1977RO-77-39:on 770421,suction Valves CAV-38 & 46 from Boric Acid Storage Tanks Found Shut.Cause Unknown.Directive Issued Requiring Shift Supervisor Authorization Before Manipulating Process ValvesBoric Acid
ML19317G3192 May 1977RO 77-38E:on 770413-14,fish Impingement on Intake Screens Exceeded Tech Specs Limits.Caused by Seasonal Changes