_

A., '

SUPPLEMENTARY INF0Pf1ATION 1.

Rep' ort -No. :

50-302/80-014/04L-0

.2.

Facility:

Crystal River. Unit No. 3 3.-

Report Date:

March 21, 1980

- 4.

.0ccurrence Date:

4th quarter 1979 (discavered:' 21 February 1980)

'(conf"i rmed : 13 March 1980)

.(detemined at plant: 18 March 1980) 5.

Identification of Occurrence:

A single measured value of radioactivity concentration in a critical pathway envircnmental medium samples exceeds ten (10) times the con-trol station value as defined in Appendix 3, Section 3.2.

6.

Conditions ' Prior to Occurrence:

-N/A 7.

Description of Occurrence:

The air c,oncentration for Thorium-232 of 0.2 pCi/m3 was greater than ten -(10) times the pre-operational level -of 0.008 pCi/m3 at sampling station-C-41.

3.

. Designation of Apparent -Cause:

. The apparent cause of the occurrence was a coal slag pile, located six

,(6). meters south of. the air samoler at station C-41.

The concentra-tion of. Thorium-232 was approximately.'1230 pCi/Kg in the soil sample at the coal slag pile.

Soil concentration during the previous ' two years has been 49 pCi/Kg or less.

Therefore, the increased air con-centration is attributed to the increased concentration from the coal siag pile.

9.-

Analysis of Occurrence:

The ~. occurrence was not a result of the operation of Crystal River

~ Unit 3.

10. - Corrective Action:

Remedy of this situation by relocation of the coal slag pile or re-location of sampling '~ station -C-41 outside the influence of the coal slag pile is under = study.

11.

Fail ure' Date:

.This is the first. report' for this type occurrence.

(Hill *(LER)0N62 8003240 h 7

.