ENilRONMENTAL LICENSEE EVENT REPORT 77-133E cility:

Crystal River Unit #3 2.

Report Date:

I November 1977 3.

Cccurrence Date:

30 September through 7 October 1977 4.

ConfiHiation Date: 28 October 1977 5.

Identification of occurrence:

Air inhalation sample station C41 showed gross S activity in excess of ten times the control station activity.

6.

Conditions Prior to Occurrences Crystal River Unit #3 was operating in Mode 1, power operation.

7.

Description of occurrence:

The weekly ai; umple at station C41 for 30 September - 7 October 197'~ was analyzed for I-131 activity. The activity was 0.13 pCi/m3 This is greater s.

than 10 times the control station value which is the smaller of 0.004 pC1/m3 (upper 95% percentile value from the preoperational program) or 0.13 pC1/m3 (upper 95 percentile from operational stations outside of the plant's influence).

8.

Designation of Apparent Cause:

The apparent cauac of this occurrence is the fallout resulting from the nuclear weapons tent by the Peoples Republic of China on 19 September 1977.

A sittilar increase in airborne activity levels was reported throughout the State of Florida.

[9. Analysis of Occurrence:

Crystal River Unit #3 did not cause the radiological environmental monitoring reporting level to be exceeded.

O.

Previous Occurrenecs:

This is the accond occurrence of this particular t.ype subseque_nt to the issuance of the Crystal River Unic #3 Facility Operating License, humorous similar occurrences were detected during the preoperational program.

@]D D

J w JU rm D '9'T

~

J

.3.S.1.

a 8002280 N

.