ML19317G221

From kanterella
Jump to navigation Jump to search
RO-77-79:on 770708,1 & 4 Vol % Hydrogen Balance Nitrogen Failed to Meet Tech Spec Acceptance Criteria During Gas Chromatograph Calibr.Caused by Separation Column Resolution Loss.Replacement Column Will Be Maintained
ML19317G221
Person / Time
Site: Crystal River 
Issue date: 08/03/1977
From: Stewart W
FLORIDA POWER CORP.
To:
Shared Package
ML19317G217 List:
References
NUDOCS 8002280855
Download: ML19317G221 (2)


Text

-

i---

LICEhiEIEE EVENT REPORT i{

  • CONTROL OLOCK:l l

l l

l l

l

[pLEASE PRIfJT ALL PEQUtntD INFCRT.1AT;O7;;

l 1

S NAME LCENSE NUMBER TYPE lFl} lCl Rl Pl 3l l 0 l 0-l-l 0 l 0 l 0 l-0 l 0 l-l O l 0 l l 4l 1l 1l ll 1l l0l3l 7 09 14 15 25 25 30 31 32 CATECORY TYP O

00CMET NUMOER EVENT CATE REPORT oATE D 1 CONT l - l - l lL l lL l l 0 l 5 l 0 l-l 0 l 3 l 0 l 2 l l 0 l 7 l 0 l8 l7 l7 l l0 l8 l0 l 3 l7 l7 l 7 8 57 50 59 60 61 68 69 74 75 00 EVENT OESCRIPTION Ql During calibration of the Fisher gas chromatograph, the 1 and 4 volume percent hydrogen l

7 89 e

Q[ balance nitrogen did' not meet the acceptance criteria required by Tech Spec 4.6.4.1.

7 89 go O

l Redundancy was maintained as the H2 analyzer was available and operable. This was the l

7 89 00 05 l first occurrence of this event. A replacement separation colu=n was ordered and the l

7 U9 gl chromatograph was restored operable.

(LER 77-79) 7 89 60 E

00E COMPONENT COCE A

MAP UA R VCLAICN lPlBl l,,,,Ej lXlXlXlXlXlXl lN l l Zl 9 [ 9 l 9 l lN [

O 7 89 10 11 12 17 43 44 47 48 CAUSE DESCRIPTION

  • *s ldTEl l This occurrence was caused by the loss of resolution of the chromatograph's separation y

7 89 OO l column. A replacement column will be maintained at all times to ensure timely l

7 7

80 corrective action.

]

FAC:UTY METHoo oF STATUS 4 POWER oTHER STATUS DISCOVERY DISCoVERf CESCRPTON

{

l 1l 0l 0l l NA l

l Cl l

NA l

ss 70 9

10 12 13 44 45 46 c0 ACTMTV CONTENT RELEASEo OF RELEASE l AMOUNT CF ACTMTY.

LoCATCN OF RELEASE lZ l lZj NA l

l NA l

7 0 0

10 11 44 45 80 PERSONNEL EXPOSURES NUM0ER TYPE CESCRIPTCN III3l l0 l 0l 0l

[ Zj l

NA l

7 09 11 12 13 60 PERSONNEL INJUPIES NUM0E R DESCR.PTON 3 l0l0l0l l

NA l

7 8D 11 12 60 OFFSITE CONSEQUENCES 7 00 00 LOSS OR OAMAGE TO FACILITY T Yl'E CESCRPTCN

$dl NA l

7 8D 10 LU PUBUCITY

$l NA l

..g DITIONAL FACTORS See attached Suppletanntarv Information 8 002 2H

.j 00 tiu 8I 1

7 oo nu NAME:

U.

P. St?# art PHONE: -(813) 866-4159 an.u,.,

\\

SUPPLEMENTARY INFORMATION 1.

Repdre No.:

50-302/77-79 2.

Facility:

Crystal River Unit #3 3.

Report Date:

3 August 1977 4.

Occurrence Date:

8 J917 1977 5.

Identification of Occurrence:

Inoperability of gas chromatograph contrary to Technical Specification 4.6.4.1.

6.

Conditions Prior to Occurrence:

Mode 1 power operation.

7.

Description of Occurrence:

At 2150 the Fisher gas chromatograph failed to meet the calibration acceptance i

criteria as required by Technical Specifications. The 1 and 4 volume percent hydrogen, balsace nitrogen calibration would not meet the requirements due to apparent separation column degradation resulting in a loss of resolution. A replacement separation column was ordered and the gas chromatograph has been restored operable.

B,, Designation of Apparent Cause:

The cause of this event was the failure of the colum to perform its intended function.

9.

Analysis of Occurrence:

The safety and health of the plant and public were not affected as a redundant hydrogen analyzer was available and operable.

10.

Corrective Action:

A spare separation column will be maintained at all times in order that corrective action can be accomplished in a timely manner.

11.

Failure Data:

This was the first occurrence of this event. It was the second occurrence of the inoperability of this device. Refer to LER 77-72.

.