ML19308D479

From kanterella
Jump to navigation Jump to search
RO-77-88:on 770715,containment Isolation Valve SWV-47 Failed to Close During Quarterly Cycling Procedure SP-370.Caused by Loose Control Wire Connection to Limit Switch.Connection Tightened & Valve Restored to Operable Condition
ML19308D479
Person / Time
Site: Crystal River 
Issue date: 08/08/1977
From: Stewart W
FLORIDA POWER CORP.
To:
Shared Package
ML19308D473 List:
References
NUDOCS 8002280788
Download: ML19308D479 (2)


Text

.

' ' " ^ " " " " ' ~ ' * " " ' " ' " ' " ' " ' " " ' ' =

O e

' ~

iau'e UCENSE NUMBEA T

l F l L l Cl R { P l 3 l l 0 l 0 l-l 0 l 0 l 0 l 0 l 0 l-l 0 l 0 l l4l1l1l1 l1l l0 l 3 l

,)9 14 15 25 26 30 31 32 CAThCcAY "r7PE S[2 N E CCCKET NUMBER EVENT oATE AEPoAT OATE O 1 CONT l -l -l l Ll l Ll l0 l5 l0 l-l0 l3 l0 l2 l l 0l 7 l1l5 l7 l7 l l0 l 8l 0l 8l 7l 7 7 8 57 58 59 60 61 68 69 74 75 c

EVENT DESCRIPTION O2 l While performing the quarterly valve cycling procedure SP-370, containment isolation 7 89 i

g l valve SW-47 failed to close contrary to Tech-Spec 3.6.3.1.

Redundancy was maint'ained.

7 89 t

Q l with SW-25.

First time occurrence. Maintenance restored operability of SW-47.

7 89 E

gl (LER 77-88) 7 u9 e

RI 7 89 E.

p

,E cE CocE COMPONENT C DE VEXATCN O

lxlAl lEl lC IK lT lB lK b l lAl lZl9l9l9l d

7 89 10 11 12 17 43 44 47 48 CAUSE DESCRIPTION 9

[OT81 l This event was caused by a loose control wire connection to the limit switch. The

~

[

~

7 89 E. '

g l connection was tightened and SW-47 was restored operable.

7 89 E.

d.!

[

's'TE "EcovE[Y

v. PowEn o men status C

cascovERY CESCAPTCN

., E l l 3l 6l 2l l NA-

-l lB l l

NA h.

l 78 9

10 12 13 44 45 46 BC

-' - - AItNs$a - oF Nd5E l AMCUNT'oF ACTMTY LCCATCN OF RELEASE

~

l Z!

_]

NA l

l NA

, 7 8.., _9 10 11 44 45 66 PERSONNEL - EXPOSURES NUM8ER TYPE CESCAPTCN

~. -

13 l 0l 0l 0l lZl l

NA 7 8 '9 11 12 13 BC PERSONNEL INJURIES NUMBER CESCAPTON 1 14 l O! O! Ol l

'NA 7

7 8' 9 11 12 63 V OFFSTTE CONSEGUENCES lTJi] l NA I

7 89

- OC.

LOSS OR DAMtGE TO FAC:UTY TYPE CESCRPTON VA

.. 7 80

.. 10 GC PUBL! CITY

$_l NA l

7 89 iG ADDITIONAL FACTORS 002 2802 P8

,g l

SEE ATTACHED SUPPLEMENTARY INFORMATION W.

P'. Stewart [,, \\

PHONE: 813/866-4159 M E.

(%/ )

CPO 449 64F 0

~ - - -

~

SUPPLEMENTARY.INFORMATION im Report No.:

50-302/77-88 2.

-Facility:

Crystal River Unit #3 3.

Report Date:

8 August 1977 4.

Occurrence Date:

15 July 1977 5.

Identification of Occurrence:

Containment isolation valve SW-47 inoperable contrary to Technical Specification 3.6.3.1.

6.

Conditions Prior to Occurrence:

Mode 1 power operation.

7.

Description of Occurrence:

At 0700, while performing the quarterly valve cycling surveillance procedure, SP-370, Nuclear Services Closed Cycle Cooling Valve SW-47 would not close from the Control s.

Room.

Redundant valve SW-25 was manually closed and valve SW-47 was taken out-of-service for maintenance. Maintenance was performed restoring SW-47 operable.

8.

Designation of Apparent Cause:

This event was caused by a loose wire on the limit switch.

9.

Analysis of Occurrence:

There were no safety implications due to this event, as redundant valve SW-25 was utilized for containment isolation.

10.

Corrective Action:

None required as normal maintensace restored operability of SW-47.

11.

Failure Data:

This was the first occurrence of SW-47 failure to operate.

s 6

e w

w qw -