CATEGORY1REGULATINFORMATION DISTRIBUTION YSTEM(RIDS)ACCESSION NBR:9803180016 DOC.DATE:

98/02/28NOTARIZED:

NOFACIL:50-335 St.LuciePlant,Unit1,FloridaPower6LightCo.50"389St.LuciePlant,Unit2,FloridaPower6LightCo.AUTH.NAMEAUTHORAFFILIATION ROGERS,J.A.

FloridaPower&LightCo.STALL,J.A.FloridaPower6LightCo.RECIP.NAME RECIPIENT AFFILIATION DOCKET0500033505000389

SUBJECT:

Monthlyoperating reptsforFeb1998forStLucie,Units 1&.2.W/980310 ltr.DISTRIBUTION CODE:IE24DCOPIESRECEIVED:LTR ENCLSIZE:TITLE:MonthlyOperating Report(perTechSpecs)NOTES:EINTERNAL:

RECIPIENT IDCODE/NAME PD2-3PDR01COPIESLTTRENCL11111111RECIPIENT IDCODE/NAME GLEAVES,W AEOD/SPD/RRAB OC/DBA/PAD COPIESLTTRENCL1111110EXTERNAL:

LITCOBRYCE,JHNRCPDR1111NOAC11DNOTETOALL"RIDS"RECIPIENTS:

PLEASEHELPUSTOREDUCEWASTE.TOHAVEYOURNAMEORORGANIZATION REMOVEDFROMDISTRIBUTION LISTSORREDUCETHENUMBEROFCOPIESRECEIVEDBYYOUORYOURORGANIZATION, CONTACTTHEDOCUMENTCONTROLDESK(DCD)ONEXTENSION 415"2083TOTALNUMBEROFCOPIESREQUIRED:

LTTR10ENCL10 r

FloridaPower&LightCompany,6351S.OceanDrive,JensenBeach,FL34957March10,1998L-98-7110CFR50.36U.S.NuclearRegulatory Commission Attn:DocumentControlDeskWashington, DC.20555Re:St.LucieUnits1and2DocketNos.50-335and50-389PursuanttoTechnical Specification 6.9.1.6,andtheguidanceofGenericLetter97-02,attachedaretheFebruary1998Operating DataReport,SummaryofOperating Experience Report,andUnitShutdowns andPowerReductions forSt.LucieUnits1and2.Shouldtherebeanyquestions onthisinformation, pleasecontactus.Verytrulyours,J.A.StallVicePresident St.LuciePlantJAS/sptAttachments cc:RegionalAdministrator, RegionII,USNRCSeniorResidentInspector, USNRC,St.LuciePlant980$i800ih980228PDRADQCK05000335R.'DRIIIIIII!llfllfllllllf IlllfillillffffffffanFPLGroupcompany

,h DOCKETNO50-335UNI'fNAME'T.LUCIEUNIT1DATE03/05/98COMPLETED BYJ.A.ROGERSTELEPHONE 561/467/7296 REPORTING PERIOD:FEBRUARY19981.DesignElectrical Rating(Mwe-Net) 8302.MaximumDependable Capacity(Mwe-Net) 839MONTH-YTD-CUMULATIVE 3.NumberofHoursReactorCritical4.NumberofHoursGenerator OnLine5.UnitReserveShutdownHours510.4504.00.01099.21049.50.0144625.5142989.70.06.NetElectrical Energy(MWH)423686798515115683574 UMMARYOFPERATEXPIEEDOCKETNO.:UNIT:DATE:COMPLETED BY:TELEPHONE:

50-335St.Lucieg1March5,1998J.A.ROGERS (561)467-7296REPORTMONTHeb1Unit1operatedatfullpowerthroughFebruary16.OnFebruary17,theunitdownpowered andwasremovedfromserviceat0334toreplacesealsonthe1B2reactorcoolantpump.Theunitwasreturned'toserviceat0333onFebruary24,andreachedfullpowerat1837.Inaccordance withtherequirements ofTechnical Specification 6.9.1.6,therewerenochallenges tothepoweroperatedreliefvalvesorthesafetyvalvesduringthereportperiod.

UNITSHUTDOWNS ANDPOWERREDUCTIONS DOCKETNO.:UNITNAME:DATE:COMPLETED BY:50-335ST.LUCIEUNIT1March5,1998J.A.RogersNumberDateType'uration (Hours)Reason'ethod ofShuttingDownReactor'ause

&Corrective ActiontoPreventRecurrence 2/17/980.0UnitIdownpowered toreplace1B2reactorcoolantpumpseals.2/17/98S168.0UnitIofflinetoreplace1B2reactorcoolantpumpseals.FForcedSScheduled ReasonA-Equipment failure(explain)

B-Maintenance orTestC-Refueling D-Regulatory restriction E-OperatorTraining&LicenseExamination F-Administrative G-Operational Error(Explain)

H-Other(Explain)

Method1-Manual2-ManualScram3-Automatic Scram4-Continued 5-LoadReduction 9-Other(Explain) 091S47PN DOCKETNO50-389UNITNAMEST.LUCIEUNIT2DATE03/05/98COMPLETED BYJ.A.ROGERSTELEPHONE 561/467/7296 REPORTING PERIOD:FEBRUARY19981.DesignElectrical Rating(Mwe-Net) 8302.MaximumDependable Capacity(Mwe-Net) 839MONTH-YTD-CUMULATIVE 3.NumberofHoursReactorCritical4.NumberofHoursGenerator OnLine5.UnitReserveShutdownHours6726720.0141614160.0108657.5107056.60.06.NetElectrical Energy(MWH)577194121216387478556 YOPERATIEXPERIEEDOCKETNO.:UNIT:DATE:COMPLETED BY:TELEPHONE:

50-389St.Lucie52March5,1998J.A.ROGERS (561)467-7296REPORTMONTHUnit2operatedatessentially fullpowerfortheentiremonthofFebruary.

Inaccordance withtherequirements ofTechnical Specification 6.9.1.6,therewerenochallenges tothepoweroperatedreliefvalvesorthesafetyvalvesduringthereportperiod.

UNITSHUTDOWNS ANDPOWERREDUCTIONS DOCKETNO.:UNITNAME:DATE:COMPLETED BY:TELEPHONE:

50-389STLUCIEUNIT2March5;1998J.A.Rogers(561)467-7296REPORTMONTHNumberDateTypeDuration(Hours)Reason'ethod ofShuttingDownReactor'ause

&Corrective ActiontoPreventRecurrence Unit2operatedatessentially fullpowerfortheentiremonthofFebruary.

1FForcedSScheduled 2ReasonA-Equipment failure(explain)

B-Maintenance orTestC-Refueling D-Regulatory restriction E-OperatorTraining&LicenseExamination F-Administrative G-Operational Error(Explain)

H-Other(Explain) 3Method1-Manual2-ManualScram3-Automatic Scram4-Continued 5-LoadReduction 9-Other(Explain)