ML17229A830

From kanterella
Jump to navigation Jump to search
Monthly Operating Repts for July 1998 for St Lucie,Units 1 & 2.W/980814 Ltr
ML17229A830
Person / Time
Site: Saint Lucie  NextEra Energy icon.png
Issue date: 07/31/1998
From: Rogers J, Stall J
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
GL-97-02, GL-97-2, L-98-207, NUDOCS 9808180040
Download: ML17229A830 (11)


Text

CATEGORY 1 REGULA Y INFORMATION DISTRIBUTI SYSTEM (RIDS)

, ACCE S S ION NBR: 9 8 08180040 DOC.DATE: 98/07/31 NOTARIZED: NO DOCKET ¹ FACIL:50-335 St Lucie Plant, Unit 1, Florida Power 6 Light Co. 05000335

+0-399 St Lucie Plant, Unit 2, Florida Power 6 Light Co. 05000389 AUTH .'AME AUTHOR AFFILIATION ROGERS,J.A. Florida Power 8 Light Co.

STALL,J.A. Florida Power 6 Light Co.

RECIP.NAME RECIPIENT AFFILIATION

SUBJECT:

Mont .ly op rating repts for July 1998 for St Lucie,Units 1 &

2. i980814 tr.

DISTRIBUTION CODE: IE24D COPIES RECEIVED:LTR' TITLE: Monthly Operating Report (per Tech Specs)

ENCL 3 SIZE:

E NOTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL " ID CODE/NAME LTTR ENCL 0 PD2-3 PD 1 1 GLEAVES,W 1

R INTERNAL: 1 1 AEOD/SPD/RRAB 1 1 1 1 OC/DBA/PAD 1 1 RGN2 1 1 EXTERNAL: LITCO BRYCE,J H 1 1 NOAC 1 1 NRC PDR 1 1 D

0 E

N NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED: LTTR 10 ENCL 10

I g

1 I

Fforida Power 8c Light Company, 6501 South Ocean Drive, Jensen Beach, FL 34957 August 14, 1998 RPI L-98-207 '0 CFR 50.36 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re: St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 Monthl 0 eratin Re ort Pursuant to Technical Specification 6.9.1.6, and the guidance of Generic Letter 97-02, attached are the July 1998 Operating Data Report, Summary of Operating Experience Report, and Unit Shutdowns and Power Reductions for St. Lucie Units 1 and 2.

Please contact us should there be any questions regarding this information.

Very truly yours,:

J. A. Stall Vice President St. Lucie Plant JAS/spt Attachments cc: Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant ~> )

0 PDR R -,

9808i80040 'P8073i ADOCK 05000335 P DR+

an FPL Group company

,P I

II

DOCKET NO 50 - 335 UNIT NARK ST. LUCIE UNIT 1 DATE ~ 08/07/98 COMPLETED BY J. A. ROGERS TELEPHONE 561/467/7296 REPORTING PERIOD: JULY 1998

1. Design Electrical Rating (Mwe-Net) 830
2. Maximum Dependable Capacity (Mwe-Net) 839 MONTH -YTD- CUMULATIVE
3. Number of Hours Reactor Critical 744 4770.2 148296.5
4. Number of Hours Generator On Line 744 4720.5 146660.7
5. Unit Reserve Shutdown Hours 0.0 0.0 0.0
6. Net Electrical Energy (MWH) 635591 3944661 118829720

0

SUMMARY

OF OPERATING EXPERIENCE DOCKET NO.: 50-335 UNIT: St. Lucie ¹1 DATE: Aug. 7, 1998 COMPLETED BY: J.A.ROGERS TELEPHONE: (561) 467-7296 REPORT MONTH ~Jul 1998 Unit 1 operated at essentially full power for the entire month of July.

In accordance with the requirements of Technical Specification 6.9.1.6, there were no challenges to the power operated relief valves or the safety valves during the report period.

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.: 50-335 UNIT: St. Lucie Nl DATE Aug. 7, 1998 COMPLETED BY: J.A.ROGERS TELEPHONE: (561) 467-7296 REPORT MONTH Jvlv1 998 Number Date Type Duration Reason Method of Cause 6 Corrective 1 (Hours) 2 Shutting Action to Down Prevent Recurrence Reactor3 Unit 1 operated at essentially full power for the entire month of July.

2 3 F Forced Reason Method S Scheduled A - Equipment Failure (Explain) 1 - Manual B - Maintenance or Test 2 - Manual Scram C Reiueling 3 Automatic Scram D Regulatory Restriction 4 Continued E - Operator Training r License Examination 5 - Load Reduction F

- Administrative 9 Other (Explain)

G H - Operational Error (Explain)

Other (Explain) 091581 8 pa

DOCKET NO 50 - 389 UNIT NAME ST. LUCIE UNIT 2 DATE 08/07/98 COMPLETED BY J. A. ROGERS TELEPHONE 561/467/7296 REPORTING PERIOD: JULY 1998

1. Design Electrical Rating (Mwe-Net) 830
2. Maximum Dependable Capacity (Mwe-Net) 839 MONTH -YTD- CUMULATIVE
3. Number of Hours Reactor Critical 744 5087 112328.5
4. Number of Hours Generator On Line 744 5057.9 110698.5
5. Unit Reserve Shutdown Hours 0.0 0.0 0.0
6. Net Electrical Energy (MWH) 631261 4323279 90589672

SUMMARY

OF OPERATING EXPERIENCE DOCKET NO.: 50-389 UNIT: St. Lucie ¹2 DATE: Aug. 7, 1998 COMPLETED BY: J.A.ROGERS TELEPHONE: (561) 467-7296 REPORT MONTH ~lul 199$

Unit 2 operated at essentially full power for the entire month of July.

In accordance with the requirements of Technical Specification 6.9.1.6, there were no challenges to the power operated relief valves or the safety valves during the report period.

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.: 50-389 UNIT: St. Lucie $2 DATE: Aug. 7, 1998 COMPLETED J.A.ROGERS BY'ELEPHONE:

(561) 467-7296 REPORT MONTH J~ul 1998 Number Date Type Duration Reason Method of Cause 6 Corrective 1 (Hours) 2 Shutting Action to Down Prevent Recurrence Reactor3 Unit 2 operated at essentially full popover for the entire month of July.

F Forced Reason Method A - Equipment 1 - Manual S Scheduled

- MaintenanceFailure (Explain) 2 - Manual Scram B

C - Refueling or Test 3 Automatic Scram D - Regulatory Restriction 4 - Continued E - Operator Training 4 License Examination 5 - Load Reduction F - Administrative 9 - Other tExplain)

G - Operational Error tExplain)

H - Other (Explain) 0915SI IIL