ML20059F992: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
Line 2: Line 2:
| number = ML20059F992
| number = ML20059F992
| issue date = 10/29/1993
| issue date = 10/29/1993
| title = Forwards Revised Quad-Cities Nuclear Power Station Unit 2 Cycle 13 Startup Test Results.
| title = Forwards Revised Quad-Cities Nuclear Power Station Unit 2 Cycle 13 Startup Test Results
| author name = Schrage J
| author name = Schrage J
| author affiliation = COMMONWEALTH EDISON CO.
| author affiliation = COMMONWEALTH EDISON CO.

Revision as of 21:57, 6 January 2021

Forwards Revised Quad-Cities Nuclear Power Station Unit 2 Cycle 13 Startup Test Results
ML20059F992
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 10/29/1993
From: Schrage J
COMMONWEALTH EDISON CO.
To: Murley T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
Shared Package
ML20059F995 List:
References
NUDOCS 9311050207
Download: ML20059F992 (1)


Text

y

_ Ccmmonwntth Edi:on  ;

. I 1400 Opus Place Downers Grove. Encis 60515 October 29,1993 f F

~

Dr. omas E. Murley, Director Office of Nuclear Reactor Regulation  :

U.S. Nuclear Regulatory Commission t Washington, DC 20555 I

Attn: Document Control Desk

Subject:

Quad Cities Nuclear Station Unit 2 Startup Test Report Summary -

Additional Information i NRC Docket No. 50-265 i

Reference:

W.E. Morgan to T.E. Murley letter dated August 24,1993 ,

t

Dear Dr. Murley:

In the referenced letter, Commonwealth Edison Company (CECO) provided the [

Startup Test Report for Quad Cities Station Unit 2, Cycle 13, in accordance with the Quad  ;

Cities Station Technical Specifications.

At that time, CECO indicated that Test No. 4 (core power distribution symmetry analysis) had not yet been completed, and that a supplement to the report would be upon ,

completion of the test.

The purpose of this letter is to provide the results of Test No. 4, core power  !

distribution symmetry analysis for Quad Cities Unit 2, Cycle 13.

If there are any questions regarding this ceport, please contact this office.  !

Sincerely,

- hp ok t, John L.'Schrage Nuclear Licensing Administrator *

Attachment:

Quad Cities Nuclear Power Station

Unit 2 Cycle 13 Startup Test Results;
  • Supplement One cc: J.B. Martin, Regional Administrator-Rill O. Patel, Project Manager-NRR .

T.E. Taylor, Senior Resident inspector-Ouad Cities k:\nla\ quad \ wayne:1 C500f0 [ i i

9311050207 931029 U -

PDR ADOCK 05000265 M

-. . ._. -