Line 15: |
Line 15: |
|
| |
|
| =Text= | | =Text= |
| {{#Wiki_filter:December 13, 2007 | | {{#Wiki_filter:December 13, 2007 LICENSEE: PPL Susquehanna, LLC FACILITY: Susquehanna Steam Electric Station, Units 1 and 2 |
| | |
| LICENSEE: PPL Susquehanna, LLC FACILITY: Susquehanna Steam Electric Station, Units 1 and 2 | |
|
| |
|
| ==SUBJECT:== | | ==SUBJECT:== |
|
| |
|
| ==SUMMARY== | | ==SUMMARY== |
| OF TELEPHONE CONFERENCE CALL HELD ON OCTOBER 3, 2007, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PPL SUSQUEHANNA, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION | | OF TELEPHONE CONFERENCE CALL HELD ON OCTOBER 3, 2007, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PPL SUSQUEHANNA, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PPL Susquehanna, LLC, held a telephone conference call on October 3, 2007, to discuss and clarify the staff=s requests for additional information (RAIs) concerning the Susquehanna Steam Electric Station, Units 1 and 2, license renewal application (LRA). provides a listing of the participants and Enclosure 2 contains a listing of the RAIs discussed with the applicant, including a brief description on the status of the items. |
| | | The applicant had an opportunity to comment on this summary. |
| The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PPL Susquehanna, LLC, held a telephone conference call on October 3, 2007, to discuss and clarify the staff=s requests for additional information (RAIs) concerning the Susquehanna Steam Electric Station, Units 1 and 2, license renewal application (LRA). | | /RA/ |
| provides a listing of the participants and Enclosure 2 contains a listing of the RAI's discussed with the applicant, including a brief description on the status of the items. | | Evelyn Gettys, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-387 and 50-388 |
| | |
| The applicant had an opportunity to comment on this summary. | |
| | |
| /RA/ Evelyn Gettys, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation
| |
| | |
| Docket Nos. 50-387 and 50-388 | |
|
| |
|
| ==Enclosures:== | | ==Enclosures:== |
| : 1. List of Participants | | : 1. List of Participants |
| : 2. List of RAIs | | : 2. List of RAIs cc w/encls: See next page |
|
| |
|
| cc w/encls: See next page
| | ML072880051 OFFICE LA:DLR PM:RPB1:DLR BC:RPB1:DLR NAME SFigueroa EGettys LLund DATE 11/8/07 11/12/07 12/13/07 |
|
| |
|
| ML072880051 OFFICE LA:DLR PM:RPB1:DLR BC:RPB1:DLR
| | TELEPHONE CONFERENCE CALL SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS OCTOBER 3, 2007 PARTICIPANTS AFFILIATIONS Evelyn Gettys U.S. Nuclear Regulatory Commission (NRC) |
| | Peter Barbadoro NRC Phil Qualls NRC Naeem Iqbal NRC Duane Filchner PPL Susquehanna, LLC (PPL) |
| | Mike Detamore PPL David Cassell PPL ENCLOSURE 1 |
|
| |
|
| NAME SFigueroa EGettys LLund DATE 11/8/07 11/12/07 12/13/07 ENCLOSURE 1 TELEPHONE CONFERENCE CALL SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS OCTOBER 3, 2007
| | REQUESTS FOR ADDITIONAL INFORMATION (RAIs) |
| | SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION OCTOBER 3, 2007 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PPL Susquehanna, LLC, held a telephone conference call on October 3, 2007, to discuss and clarify the following RAIs concerning the Susquehanna Steam Electric Station (SSES), Units 1 and 2, license renewal application (LRA). |
| | RAI 2.3.3.13-1 LRA drawing LR-M-122, Sheet No. 1, AFire Pumphouse, North & South Gatehouse & Security Control Center Buildings,@ shows the jockey pump and associated components as out of scope (i.e., not colored in green). Section 9.5.1.1 of the SSES, Units 1 and 2 SER (NUREG-0776), |
| | dated April 1981, states that a separate jockey pump automatically maintains the yard fire main pressure. The jockey pump and its associated components appear to have fire protection intended functions required for compliance with 10 CFR 50.48 as stated in 10 CFR 54.4. The staff requests that the applicant verify whether jockey pump and its associated components are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an aging management review (AMR) in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion. |
| | Discussion: The applicant agreed to reevaluate the issue of the jockey pumps being in the scope of license renewal. |
| | RAI 2.3.3.13-2 The following LRA drawings show fire protection system components as out of scope (i.e., not colored in green): |
| | LR-M-122 Sheet 1, AFire Pumphouse, North & South Gatehouse & Security Control Center Buildings,@ shows Diesel Oil Day Tank (0T508) vent line and the fill cap-assembly line, piping, fittings, and drains as out of scope (i.e., not colored in green). |
| | LR-M-122 Sheet 2, ATurbine Bldg., Control Structure and Radwaste Building,@ shows several fire suppression systems and components in Turbine Building Units 1 and 2 as out of scope (i.e., not colored in green). |
| | LR-M-122 Sheet 3, AReactor Bldg., Standby D G, River Intake Structure. Service and Admin. |
| | Bldg. & Circ. Water Pumphouse,@ shows several fire suppression systems and components in Turbine Building Units 1 and 2, Circ. Water Pumphouse, and River Intake Structure as out of scope (i.e., not colored in green). |
| | LR-M-122 Sheet 4, ACarbon Dioxide System,@ shows several components as out of scope (i.e., |
| | not colored in green). |
| | ENCLOSURE 2 |
|
| |
|
| PARTICIPANTS AFFILIATIONS Evel yn Gett ys U.S. Nuclear Re gulator y Commission (NRC)
| | The staff requests that the applicant verify whether the above fire suppression systems and components are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If these components are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion. |
| Peter Barbadoro NRC Phil Qualls NRC Naeem I qbal NRC Duane Filchne r PPL Sus quehanna, LLC (PPL) Mike Detamore PPL David Cassell PPL
| | Discussion: Based on the discussion with the applicant, the staff indicated that the response to this RAI is for clarification. The applicant agreed to clarify if these items are in scope of license renewal. |
| | RAI 2.3.3.13-3 Section 9.5.1.2 of the SSES SER (NUREG-0776), dated April 1981, listed sprinkler and standpipe systems provided in the plant areas for fire suppression activities. The sprinkler and standpipe systems are installed in various areas: |
| | ! Reactor Core Isolation Cooling Pump Room |
| | ! High Pressure Coolant Injection Pump Room |
| | ! Heating, Ventilation, and Air-Conditioning Filter Rooms |
| | ! Railroad Airlock |
| | ! Control Building Auxiliary Rooms |
| | ! Condenser Area |
| | ! Reactor Feed Pump Turbine |
| | ! Turbine Central Area |
| | ! Turbine Condenser Gallery |
| | ! Turbine Hydro Control Power Room |
| | ! North Railroad Bay |
| | ! Turbine Condenser Mezzanine |
| | ! Diesel Engine Fire Pump Room |
| | ! Lower Cable Spreading Room (CSR) |
| | ! Upper CSR |
| | ! PFP Turbine Room |
| | ! Diesel Generator Building |
| | ! Charcoal Filters |
| | ! Standby Gas Treatment Filters |
| | ! Emergency Outside Air Filters |
| | ! Centrifuge & Conditioner |
| | ! Turbine Pump Area |
| | ! Turbine Hydro Seal Oil Unit |
| | ! Turbine Lube Oil Area |
| | ! Turbine Motor Generator Area |
| | ! Turbine Filter Room |
| | ! Turbine Moisture Separation Area |
| | ! Radwaste Tank Vent Filter Room |
| | ! Radwaste Auxiliary Rooms |
| | ! Radwaste Controlled Zone Shop |
|
| |
|
| ENCLOSURE 2 REQUESTS FOR ADDITIONAL INFORMATION (RAIs) SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION OCTOBER 3, 2007
| | The staff requests that the applicant verify whether the sprinkler and standpipe systems installed in the above areas of the plant are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion. |
| | | Discussion: Based on the discussion with the applicant, the staff indicated that the response to this RAI is for clarification. The applicant agreed to clarify if these items are in scope. |
| The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PPL Susquehanna, LLC, held a telephone conference call on October 3, 2007, to discuss and clarify the following RAIs concerning the Susquehanna Steam Electric Station (SSES), Units 1 and 2, license renewal application (LRA).
| | RAI 2.3.3.13-5 LRA Table 2.3.3-13 excludes several types of fire protection components that appear in the SSES SER (NUREG-0776), dated April 1981 and/or Fire Protection Review Report. These components are listed below: |
| | | ! Hose stations |
| RAI 2.3.3.13-1
| | ! Spray nozzles (water, CO2/Halon) |
| | | ! Dikes for oil spill confinement |
| LRA drawing LR-M-122, Sheet No. 1, AFire Pumphouse, North & South Gatehouse & Security Control Center Buildings,@ shows the jockey pump and associated components as out of scope (i.e., not colored in green). Section 9.5.1.1 of the SSES, Units 1 and 2 SER (NUREG-0776), dated April 1981, states that a separate jockey pump automatically maintains the yard fire main pressure. The jockey pump and its associated components appear to have fire protection intended functions required for compliance with 10 CFR 50.48 as stated in 10 CFR 54.4. The staff requests that the applicant verify whether jockey pump and its associated components are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an aging management review (AMR) in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.
| | ! Floor drains and curbs for fire-fighting water |
| | | ! Filter housing |
| Discussion: The applicant agreed to reevaluate the issue of the jockey pumps being in the scope of license renewal.
| | ! Strainer housing |
| RAI 2.3.3.13-2 The following LRA drawings show fire protection system components as out of scope (i.e., not colored in green):
| | ! Heater housing |
| | | ! Chamber housing |
| LR-M-122 Sheet 1, AFire Pumphouse, North & South Gatehouse & Security Control Center Buildings,@ shows Diesel Oil Day Tank (0T508) vent line and the fill cap-assembly line, piping, fittings, and drains as out of scope (i.e., not colored in green).
| | ! Actuator housing |
| | | ! Pipe supports |
| LR-M-122 Sheet 2, ATurbine Bldg., Control Structure and Radwaste Building,@ shows several fire suppression systems and components in Turbine Building Units 1 and 2 as out of scope (i.e., not colored in green).
| | ! Halon storage bottles |
| | | ! Water storage tanks |
| LR-M-122 Sheet 3, AReactor Bldg., Standby D G, River Intake Structure. Service and Admin. Bldg. & Circ. Water Pumphouse,@ shows several fire suppression systems and components in Turbine Building Units 1 and 2, Circ. Water Pumphouse, and River Intake Structure as out of scope (i.e., not colored in green).
| | ! Buried outside diesel fuel storage tanks |
| | | ! Heat exchanger (bonnet) |
| LR-M-122 Sheet 4, ACarbon Dioxide System,@ shows several components as out of scope (i.e., not colored in green).
| | ! Turbocharger |
| | | ! Lubricating oil collecting system components (reactor coolant pump) |
| The staff requests that the applicant verify whether the above fire suppression systems and components are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If these components are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.
| | ! Engine intake and exhaust silencers/muffler (diesel driven fire pump) |
| | | ! Manual smoke removal systems and their associated components (control structure including CSRs) |
| Discussion: Based on the discussion with the applicant, the staff indicated that the response to this RAI is for clarification. The applicant agreed to clarify if these items are in scope of license renewal. RAI 2.3.3.13-3 | | The staff requests that the applicant verify whether the components listed above should be included in LRA Table 2.3.3.13. If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion. |
| | | Discussion: Based on the discussion with the applicant, the staff indicated that the response to this RAI is for clarification. The applicant agreed to clarify what determines when the halon storage bottles are replaced, and to clarify if the listed components are in the scope of license renewal. |
| Section 9.5.1.2 of the SSES SER (NUREG-0776), dated April 1981, listed sprinkler and standpipe systems provided in the plant areas for fire suppression activities. The sprinkler and standpipe systems are installed in various areas:
| |
| | |
| ! Reactor Core Isolation Cooling Pump Room
| |
| ! High Pressure Coolant Injection Pump Room
| |
| ! Heating, Ventilation, and Air-Conditioning Filter Rooms
| |
| ! Railroad Airlock
| |
| ! Control Building Auxiliary Rooms
| |
| ! Condenser Area
| |
| ! Reactor Feed Pump Turbine
| |
| ! Turbine Central Area
| |
| ! Turbine Condenser Gallery
| |
| ! Turbine Hydro Control Power Room
| |
| ! North Railroad Bay
| |
| ! Turbine Condenser Mezzanine
| |
| ! Diesel Engine Fire Pump Room
| |
| ! Lower Cable Spreading Room (CSR)
| |
| ! Upper CSR ! PFP Turbine Room
| |
| ! Diesel Generator Building
| |
| ! Charcoal Filters
| |
| ! Standby Gas Treatment Filters
| |
| ! Emergency Outside Air Filters
| |
| ! Centrifuge & Conditioner
| |
| ! Turbine Pump Area
| |
| ! Turbine Hydro Seal Oil Unit
| |
| ! Turbine Lube Oil Area
| |
| ! Turbine Motor Generator Area
| |
| ! Turbine Filter Room
| |
| ! Turbine Moisture Separation Area
| |
| ! Radwaste Tank Vent Filter Room
| |
| ! Radwaste Auxiliary Rooms
| |
| ! Radwaste Controlled Zone Shop
| |
| | |
| The staff requests that the applicant verify whether the sprinkler and standpipe systems installed in the above areas of the plant are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion. | |
| | |
| Discussion: Based on the discussion with the applicant, the staff indicated that the response to this RAI is for clarification. The applicant agreed to clarify if these items are in scope. | |
| | |
| RAI 2.3.3.13-5
| |
|
| |
|
| LRA Table 2.3.3-13 excludes several types of fire protection components that appear in the SSES SER (NUREG-0776), dated April 1981 and/or Fire Protection Review Report. These components are listed below:
| |
| ! Hose stations
| |
| ! Spray nozzles (water, CO 2/Halon) ! Dikes for oil spill confinement
| |
| ! Floor drains and curbs for fire-fighting water
| |
| ! Filter housing
| |
| ! Strainer housing
| |
| ! Heater housing
| |
| ! Chamber housing
| |
| ! Actuator housing
| |
| ! Pipe supports
| |
| ! Halon storage bottles
| |
| ! Water storage tanks
| |
| ! Buried outside diesel fuel storage tanks
| |
| ! Heat exchanger (bonnet)
| |
| ! Turbocharger
| |
| ! Lubricating oil collecting system components (reactor coolant pump)
| |
| ! Engine intake and exhaust silencers/muffler (diesel driven fire pump)
| |
| ! Manual smoke removal systems and their associated components (control structure including CSRs)
| |
| The staff requests that the applicant verify whether the components listed above should be included in LRA Table 2.3.3.13. If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.
| |
| Discussion: Based on the discussion with the applicant, the staff indicated that the response to this RAI is for clarification. The applicant agreed to clarify what determines when the halon storage bottles are replaced, and to clarify if the listed components are in the scope of license renewal.
| |
| Memo to Susquehanna Steam Electric Station from E. Gettys dated December 13, 2007 DISTRIBUTION: | | Memo to Susquehanna Steam Electric Station from E. Gettys dated December 13, 2007 DISTRIBUTION: |
|
| |
|
Line 132: |
Line 112: |
|
| |
|
| ==SUMMARY== | | ==SUMMARY== |
| OF TELEPHONE CONFERENCE CALL HELD ON OCTOBER 3, 2007, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PPL SUSQUEHANNA, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION HARD COPY: DLR RF E-MAIL: PUBLIC SSmith (srs3) | | OF TELEPHONE CONFERENCE CALL HELD ON OCTOBER 3, 2007, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PPL SUSQUEHANNA, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION HARD COPY: |
| SDuraiswamy RidsNrrDlr RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsNrrDlrReba RidsNrrDlrRebb RidsNrrDciCvib RidsNrrDciCpnb RidsNrrDraAfpb RidsNrrDeEmcb RidsNrrDeEeeb RidsNrrDssSrxb RidsNrrDssSbpb RidsNrrDssScvb RidsOgcMailCenter | | DLR RF E-MAIL: |
| | | PUBLIC SSmith (srs3) |
| | SDuraiswamy RidsNrrDlr RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsNrrDlrReba RidsNrrDlrRebb RidsNrrDciCvib RidsNrrDciCpnb RidsNrrDraAfpb RidsNrrDeEmcb RidsNrrDeEeeb RidsNrrDssSrxb RidsNrrDssSbpb RidsNrrDssScvb RidsOgcMailCenter |
| --------------- | | --------------- |
| RGuzman BRogers EGettys | | RGuzman BRogers EGettys |
| | |
| Susquehanna Steam Electric Station, Units 1 and 2
| |
| | |
| cc:
| |
| | |
| Cornelius J. Gannon Vice President - Nuclear Operations PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467
| |
| | |
| Robert M. Paley General Manager - Plant Support PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467
| |
| | |
| Rocco R. Sgarro Manager - Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179
| |
| | |
| Walter E. Morrissey Supervising Engineer Nuclear Regulatory Affairs PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467
| |
| | |
| Michael H. Crowthers Supervising Engineer Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179
| |
| | |
| Ronald E. Smith General Manager - Site Preparedness and Services PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467
| |
| | |
| Steven M. Cook Manager - Quality Assurance PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467
| |
| | |
| Luis A. Ramos Community Relations Manager, Susquehanna PPL Susquehanna, LLC 634 Salem Blvd., SSO Berwick, PA 18603-0467
| |
| | |
| Bryan A. Snapp, Esq.
| |
| Associate General Counsel PPL Services Corporation Two North Ninth Street, GENTW3 Allentown, PA 18101-1179
| |
| | |
| Supervisor - Document Control Services PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179
| |
| | |
| Richard W. Osborne Allegheny Electric Cooperative, Inc.
| |
| 212 Locust Street P.O. Box 1266 Harrisburg, PA 17108-1266
| |
| | |
| Director, Bureau of Radiation Protection Pennsylvania Department of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469
| |
| | |
| Susquehanna Steam Electric Station, Units 1 and 2
| |
| | |
| cc:
| |
| | |
| Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 35, NUCSA4 Berwick, PA 18603-0035
| |
|
| |
|
| Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406
| | Susquehanna Steam Electric Station, Units 1 and 2 cc: |
| | Cornelius J. Gannon Steven M. Cook Vice President - Nuclear Operations Manager - Quality Assurance PPL Susquehanna, LLC PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467 Berwick, PA 18603-0467 Robert M. Paley Luis A. Ramos General Manager - Plant Support Community Relations Manager, PPL Susquehanna, LLC Susquehanna 769 Salem Blvd., NUCSB2 PPL Susquehanna, LLC Berwick, PA 18603-0467 634 Salem Blvd., SSO Berwick, PA 18603-0467 Rocco R. Sgarro Manager - Nuclear Regulatory Affairs Bryan A. Snapp, Esq. |
| | PPL Susquehanna, LLC Associate General Counsel Two North Ninth Street, GENPL4 PPL Services Corporation Allentown, PA 18101-1179 Two North Ninth Street, GENTW3 Allentown, PA 18101-1179 Walter E. Morrissey Supervising Engineer Supervisor - Document Control Services Nuclear Regulatory Affairs PPL Susquehanna, LLC PPL Susquehanna, LLC Two North Ninth Street, GENPL4 769 Salem Blvd., NUCSA4 Allentown, PA 18101-1179 Berwick, PA 18603-0467 Richard W. Osborne Michael H. Crowthers Allegheny Electric Cooperative, Inc. |
| | Supervising Engineer 212 Locust Street Nuclear Regulatory Affairs P.O. Box 1266 PPL Susquehanna, LLC Harrisburg, PA 17108-1266 Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Director, Bureau of Radiation Protection Pennsylvania Department of Ronald E. Smith Environmental Protection General Manager - Site Preparedness Rachel Carson State Office Building and Services P.O. Box 8469 PPL Susquehanna, LLC Harrisburg, PA 17105-8469 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467 |
|
| |
|
| Board of Supervisors Salem Township P.O. Box 405 Berwick, PA 18603-0035 Dr. Judith Johnsrud National Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803}} | | Susquehanna Steam Electric Station, Units 1 and 2 cc: |
| | Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 35, NUCSA4 Berwick, PA 18603-0035 Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Board of Supervisors Salem Township P.O. Box 405 Berwick, PA 18603-0035 Dr. Judith Johnsrud National Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803}} |
|
---|
Category:Memoranda
MONTHYEARML23094A1252023-03-31031 March 2023 Talen Part 21 Final Notification P21-03032023-FN R0 Re Defect Identified in Automatic Transfer Switch ML22034A3932022-02-16016 February 2022 Calendar Year 2021 Security Baseline Completion Memo ML21054A3032021-04-22022 April 2021 Memo to File: Final Ea/Fonsi of Independent Spent Fuel Storage Facilities Decommissioning Funding Plans Related to Susquehanna ML17090A1332017-04-0505 April 2017 Notice of Meeting with Susquehanna Nuclear, LLC to Discuss the Nrc'S Assessment of Safety Performance at Susquehanna Steam Electric Station for 2016 ML17037B8502017-02-0606 February 2017 08/21/1975 Notice of Meeting with Architect Engineers of Mark II Owners to Discuss Load Combinations and Analytical Techniques for Determining Stresses in Mechanical Components and Structures of Mark II Containments ML16088A2042016-03-28028 March 2016 Memo T Bowers from s Ruffin, Technical Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations W/ Encl 2 (Template) ML16088A2052016-03-28028 March 2016 Enclosure 1 - (72.30 DFP Reviews to Be Completed 2015) - Memo T Bowers from s Ruffin, Technial Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations ML15345A0912015-12-17017 December 2015 Closure of Issue Found During 2014 Regulatory Commitment Audit ML15313A2392015-11-0606 November 2015 Request for Additional Information Proposed Relief Requests for the Third 10-Year Inservice Inspection Interval (TAC Nos. MF6302 Through MF6307) ML15093A3052015-04-0303 April 2015 Memorandum to the Participants NRC Staff Notification of Proposed Issuance of Order and Conforming License Amendments Approving Indirect Transfer ML14133A0592014-07-0101 July 2014 Summary of Closed Meeting Between Representatives of the Army Corps of Engineers, Nuclear Regulatory Commission, Federal Energy Regulatory Commission, Exelon Generation Co, LLC, and PPL Susquehanna, LLC, to Discuss Dam Failure Analysis.. ML14085A4112014-05-0606 May 2014 Final TIA Response Susquehanna SGTS and Secondary Ventilation ML14112A2392014-04-22022 April 2014 Notice of Forthcoming Closed Meeting to Discuss Dam Failure Analysis for Peach Bottom Atomic Power Station Units 2 and 3, Susquehanna Steam Electric Station Units 1 and 2, and Three Mile Island Nuclear Station Unit 1 ML13309A0802013-12-11011 December 2013 Memorandum to File: Transcript for 10 CFR 2.206 Petition from Beyond Nuclear (Et Al) Regarding General Electric Mark I and Mark II Boiling-Water Reactors ML13043A4062013-02-12012 February 2013 Proposed Amendment No. 309 to License NPF-14 and Proposed Amendment No. 280 to License NPF-22: Change to Technical Specification Surveillance Requirement (SR) 3.8.1.9, 3.8.1.11,3.8.1.12, and 3.8.1.19 to Increase Diesel ML13035A2482013-02-0101 February 2013 ME9609 Susquehanna Steam Electric Station Proposed Amendment No. 309 to License NPF-14 and Proposed Amendment No. 280 to License Npf -22: Change to Technical Specification Surveillance Requirement 3.8.1.19 to Increase Diesel Generator E Min ML1114410162011-05-24024 May 2011 Summary of Susquehanna Annual Assessment Meeting, May 19, 2011 ML1014700962010-05-25025 May 2010 Summary of Annual Assessment Meeting with PPL Susquehanna, LLC, to Discuss Nrc'S Assessment of Safety Performance for Calendar Year 2009 ML0925103122009-09-0808 September 2009 Drop-in Visit from PPL Susquehanna, LLC - August 31, 2009 ML0919404402009-07-13013 July 2009 Meeting Summary, Public Meeting with PPL Susquehanna, LLC Re SCWE at Site ML0915505712009-06-0101 June 2009 Meeting Minutes of the Plant License Renewal Subcommittee on April 1, 2009 ML0900803792009-01-30030 January 2009 Summary of Telephone Conference Call Held on 12/18/08, Between the U.S. NRC and PPL Susquehanna, LLC, Concerning TLAA RAI ML0833101132008-12-0303 December 2008 Meeting Summary, Telephone Conference Call Between U.S. NRC and PPL Susquehanna, LLC, Concerning the Draft Request for Additional Information Pertaining to the Susquehanna Steam Electric Station Units 1 & 2, LRA ML0832307862008-11-19019 November 2008 11/13/2008-Summary of Telephone Conference Call Between NRC and PPL, Concerning the Responses to RAIs Pertaining to the Susquehanna Steam Electric Station, Units 1 and 2, License Renewal Application ML0828901522008-10-21021 October 2008 Summary of Telephone Conference Call Held on October 8, 2008, Between the USNRC and PPL Susquehanna, Llc. Concerning Draft Requests for Additional Information Pertaining to the, License Renewal Application ML0822603532008-10-0101 October 2008 06/25/2008 Meeting Summary, Telephone Conference Call Between the NRC and PPL Susquehanna, LLC, Concerning Draft Request for Additional Information Pertaining to the Susquehanna, Units 1 and 2, License Renewal Application ML0807400842008-03-14014 March 2008 Draft Regulatory Guide for Comment ML0806303822008-03-0505 March 2008 Notice of Meeting with PPL Susquehanna, LLC (PPL) to Discuss Ppl'S Plan Regarding Compliance with the License Conditions Related to the New Steam Dryer During Extended Power Uprate Power Ascension for the Upcoming Refueling Outage ML0728800512007-12-13013 December 2007 Summary of Telephone Conference Call Held on 10/03/07, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, LLC, Concerning Fire ML0728511102007-11-16016 November 2007 Summary of Telephone Conference Call Held on October 3, 2007, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, LLC Concerning Open Items Pertaining to the Susquehanna, Units 1 and 2, License Renewal Application ML0730200012007-10-25025 October 2007 FRN - Power Uprates (Susquehanna), November 14, 2007 ML0726401342007-10-24024 October 2007 Summary of Telephone Conference Call with PPL Susquehanna, LLC Concerning Requests for Additional Information ML0728906522007-10-24024 October 2007 Summary of July 19th Conference Call Between NRC DLR Environmental Staff; PPL Susquehanna, LLC; and PPL Generating Regarding PPL Generation'S Letter of Intent to File a Combined License Application for a Potential New Unit at the SSES Site ML0724900462007-09-18018 September 2007 and 09/05/2007 Summary of Telephone Conference Calls Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, LLC, Concerning D-RAI ML0723304142007-08-27027 August 2007 Summary of Telephone Conference Call Held on August 16, 2007, Between the Us NRC and PPL Susquehanna, Concerning Request for Additional Information Pertaining to the Susquehanna, Units 1 and 2, License Renewal Application ML0721101752007-07-30030 July 2007 Notice of Meeting with PPL Susquehanna, LLC (Ppl), Susquehanna Steam Electric Station, Units 1 and 2, to Conduct a Working Level-Discussion Related to NRC Staff'S Reactor Systems Safety Review of Proposed Extended Power Uprate Application ML0716400652007-06-14014 June 2007 Notice of with PPL Susquehanna, LLC (Ppl), Susquehanna, Units 1 and 2 to Conduct a Working Level-Discussion Related to the Steam Dryer Instrumentation Plan Finite Element Analysis Model Changes, Fabrication Improvements and Start-Up Limit. ML0705800922007-03-0202 March 2007 Summary of Telephone Conference Call Held on February 12, 2007, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, Lcc, Concerning Requests for Additional Information Pertaining to the Susquehanna Steam Electric Station, Un ML0629104092006-11-0909 November 2006 Review of Susquehanna Steam Electric Station Units 1 and 2 Amendment Request to Revise Technical Specifications 3.8.1 ML0624202762006-08-30030 August 2006 09/13/2006 Notice of Forthcoming Meeting with PPL Susquehanna, LLC (PPL) Susquehanna Steam Electric Station, Units 1 and 2 (SSES 1 and 2) on Pre-License Renewal Application ML0608107012006-03-22022 March 2006 04/05/06 - Forthcoming Meeting with PPL Susquehanna, LLC (Ppl), Susquehanna Steam Electric Station, Units 1 and 2 (SSES 1 and 2) on License Renewal and Extended Power Uprate ML0530704902005-11-0303 November 2005 Forthcoming Meeting with PPL Susquehanna, LLC (Ppl), Susquehanna, Units 1 and 2 to Conduct a Working level-discussion Related to the Schedule, Approach, and Strategy for the Proposed Extended Power Uprate Application.. ML0527103892005-09-29029 September 2005 Meeting with PPL Susquehanna 1 & 2, Schedule, Approach and Strategy for the SSES Unit 1 Cycle 14 and Cycle 15 Minimum Critical Power Ratio Safety Limit Submittals in Light of the Control Cell Friction Issues Experienced on Unit 1 ML0510804732005-04-29029 April 2005 Correction to Letter Approving the Use of the Privatel Model 960V Validated to Federal Information Processing Standard (Fips) 140-1 ML0403001132004-01-30030 January 2004 Correction of License Authority Files ML0235404372002-12-18018 December 2002 Rquest for Additonal Information (RAI) for Emergency Plan (E-Plan) Revisions PLA-5567 - Attachment ML0235200602002-12-18018 December 2002 Draft Request for Additional Information (RAI) Response Regarding Amendment Request for Emergency Plan (E-Plan) Revisions ML0229705292002-10-24024 October 2002 Results of the Susquehanna Steam Electric Station Units 1 and 2 SDP Phase 2 Notebook Benchmarking Visit ML0226002922002-09-17017 September 2002 Memorandum Regarding Report on the Status of Open TIAs Assigned to NRR ML0219802582002-07-17017 July 2002 Safety Evaluation Input for Proposed Changes to the Susquehanna, Units 1 & 2 Technical Specifications Implementing Operability Requirements for the Ultimate Heat Sink Spray Valves (TAC Nos. MB2119 & MB2120) 2023-03-31
[Table view] Category:Note to File incl Telcon Record
MONTHYEARML18347A2722018-12-12012 December 2018 Conversation Record with M. Krick/ Susquehanna Steam Electric Station RAI Regarding 2015 Triennial Decommissioning Funding Plan (DFP) Update (Conversation Held on December 12, 2018) (Dkt No. 72.0028) ML1015304112010-06-0707 June 2010 Summary of Conference Call with Boiling Water Reactor Vessel and Internals Project Regarding Recent Operating Experience Associated with Replacement Steam Dryer ML0832307862008-11-19019 November 2008 11/13/2008-Summary of Telephone Conference Call Between NRC and PPL, Concerning the Responses to RAIs Pertaining to the Susquehanna Steam Electric Station, Units 1 and 2, License Renewal Application ML0832209472008-11-19019 November 2008 Summary of Telephone Conference Call Held on October 10, 2008, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, Llc., Concerning the Responses to Requests for Additional Information Pertaining to the Susquehanna Steam... ML0728800512007-12-13013 December 2007 Summary of Telephone Conference Call Held on 10/03/07, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, LLC, Concerning Fire ML0728511102007-11-16016 November 2007 Summary of Telephone Conference Call Held on October 3, 2007, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, LLC Concerning Open Items Pertaining to the Susquehanna, Units 1 and 2, License Renewal Application ML0728906522007-10-24024 October 2007 Summary of July 19th Conference Call Between NRC DLR Environmental Staff; PPL Susquehanna, LLC; and PPL Generating Regarding PPL Generation'S Letter of Intent to File a Combined License Application for a Potential New Unit at the SSES Site ML0726401342007-10-24024 October 2007 Summary of Telephone Conference Call with PPL Susquehanna, LLC Concerning Requests for Additional Information ML0715105492007-06-15015 June 2007 Summary of Telephone Conference Call Held on May 29, 2007, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, LLC, Concerning Requests for Additional Information Pertaining to the Susquehanna Steam Electric Station, Units 1 ML0705800922007-03-0202 March 2007 Summary of Telephone Conference Call Held on February 12, 2007, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, Lcc, Concerning Requests for Additional Information Pertaining to the Susquehanna Steam Electric Station, Un ML0607600212006-03-16016 March 2006 Summary of 03/14/06 Phone Call Between Eric Epstein, Chairman, Three Mile Island Alert, Inc,. and NRC Staff Regarding Proposed Spent Fuel Exemption for the Susquehanna Nuclear Generating Station ML0703804662006-03-14014 March 2006 License Renewal Scoping Meeting Handouts: TMI-Alert Exhibits ML18025A2611977-01-19019 January 1977 Letter Documenting Responses to Questions Given to Mr. Singh Bawa of the NRC from Pp&L'S Mr. E.D. Testa in Telephone Conversations on 1/17/1977 and 01/18/1977 2018-12-12
[Table view] Category:Verbal Comm
MONTHYEARML18347A2722018-12-12012 December 2018 Conversation Record with M. Krick/ Susquehanna Steam Electric Station RAI Regarding 2015 Triennial Decommissioning Funding Plan (DFP) Update (Conversation Held on December 12, 2018) (Dkt No. 72.0028) ML1015304112010-06-0707 June 2010 Summary of Conference Call with Boiling Water Reactor Vessel and Internals Project Regarding Recent Operating Experience Associated with Replacement Steam Dryer ML0832307862008-11-19019 November 2008 11/13/2008-Summary of Telephone Conference Call Between NRC and PPL, Concerning the Responses to RAIs Pertaining to the Susquehanna Steam Electric Station, Units 1 and 2, License Renewal Application ML0832209472008-11-19019 November 2008 Summary of Telephone Conference Call Held on October 10, 2008, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, Llc., Concerning the Responses to Requests for Additional Information Pertaining to the Susquehanna Steam... ML0728800512007-12-13013 December 2007 Summary of Telephone Conference Call Held on 10/03/07, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, LLC, Concerning Fire ML0728511102007-11-16016 November 2007 Summary of Telephone Conference Call Held on October 3, 2007, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, LLC Concerning Open Items Pertaining to the Susquehanna, Units 1 and 2, License Renewal Application ML0728906522007-10-24024 October 2007 Summary of July 19th Conference Call Between NRC DLR Environmental Staff; PPL Susquehanna, LLC; and PPL Generating Regarding PPL Generation'S Letter of Intent to File a Combined License Application for a Potential New Unit at the SSES Site ML0726401342007-10-24024 October 2007 Summary of Telephone Conference Call with PPL Susquehanna, LLC Concerning Requests for Additional Information ML0715105492007-06-15015 June 2007 Summary of Telephone Conference Call Held on May 29, 2007, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, LLC, Concerning Requests for Additional Information Pertaining to the Susquehanna Steam Electric Station, Units 1 ML0705800922007-03-0202 March 2007 Summary of Telephone Conference Call Held on February 12, 2007, Between the U.S. Nuclear Regulatory Commission and PPL Susquehanna, Lcc, Concerning Requests for Additional Information Pertaining to the Susquehanna Steam Electric Station, Un ML0607600212006-03-16016 March 2006 Summary of 03/14/06 Phone Call Between Eric Epstein, Chairman, Three Mile Island Alert, Inc,. and NRC Staff Regarding Proposed Spent Fuel Exemption for the Susquehanna Nuclear Generating Station ML0703804662006-03-14014 March 2006 License Renewal Scoping Meeting Handouts: TMI-Alert Exhibits ML18025A2611977-01-19019 January 1977 Letter Documenting Responses to Questions Given to Mr. Singh Bawa of the NRC from Pp&L'S Mr. E.D. Testa in Telephone Conversations on 1/17/1977 and 01/18/1977 2018-12-12
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML24150A3362024-05-29029 May 2024 Request for Confirmation of Information Relief Request 1RR06 (Proposed Alternative) Susquehanna Nuclear, LLC Susquehanna Steam Electric Station (Susquehanna), Unit 1 Docket No. 50-387 IR 05000387/20244042024-05-0707 May 2024 Information Request for the Cybersecurity Baseline Inspection, Notification to Perform Inspection 05000387/2024404 and 05000388/2024404 ML24102A1252024-04-10010 April 2024 Request for Additional Information for Susquehanna, Unit 1 Alternative Request 4RR-11 ML23334A1502023-11-30030 November 2023 NRC Request for Additional Information Re. Susquehanna Relief Request RR-02 ML23277A0412023-10-0505 October 2023 Notification of Commercial Grade Dedication Inspection (05000387/2024011 and 05000388/2024011) and Request for Information ML23013A2082023-01-13013 January 2023 Request for Additional Information ML22146A1022022-05-26026 May 2022 Information Request for the Cyber Security Baseline Inspection, Notification to Perform Inspection 05000387/2022404 and 05000388/2022404 ML22146A0742022-05-25025 May 2022 NRR E-mail Capture - NRC Request for Additional Information - Susquehanna License Amendment Request ML22111A3132022-04-21021 April 2022 NRR E-mail Capture - NRC Request for Additional Information - Susquehanna License Amendment Request ML22041A1562022-02-10010 February 2022 Information Request for a Triennial Baseline Design Bases Assurance Inspection (Team); Inspection Report 05000387/2022013 and 05000388/2022013 ML21316A1242021-11-18018 November 2021 Supplemental Information Needed for Acceptance of Requested Licensing Action Regarding Emergency Core Cooling Technical Specifications ML20056E4392020-02-21021 February 2020 Ti 2515/194 Inspection Documentation Request ML20010D2012020-01-0909 January 2020 Request for Additional Information Related to Request to Allow Application of Framatome Analysis Methodologies Necessary to Support a Planned Transition to Atrium 11 Fuel Under Maximum ML19319A0092019-11-14014 November 2019 NRR E-mail Capture - Draft RAI for SSES Units 1 and 2 LAR to Replace ESW Piping ML19319B1922019-11-14014 November 2019 NRR E-mail Capture - RAI for Susquehanna, 1 and 2 License Amendment Request - Replace the Emergency Service Water System and Residual Heat Removal Service Water System ML19128A0232019-05-0707 May 2019 Request for Additional Information: Susquehanna Steam Electric Station, Units 1 and 2 License Amendment Request for ESW Piping Replacement ML18352B1832018-12-13013 December 2018 Enclosurequest for Additional Information (Letter to K. Cimorelli Request for Additional Information Regarding Susquehanna Nuclear, Llc'S Decommissioning Funding Plan Update for Susquehanna Steam Electric Station Independent Spent Fuel Stor ML17180A2002017-07-0707 July 2017 Request for Additional Information Regarding License Amendment Request to Revise Diesel Generator Surveillance Requirements with New Steady State Voltage and Frequency Limits ML17059D2142017-03-0606 March 2017 Susquehanna Steam Electric Station - Supplemental Information Needed for Acceptance of Requested Licensing Action Re: License Amendment Request to Revise Diesel Generator Surveillance Requirements with New Steady State Voltage Frequency Limits ML16251A0652016-09-0909 September 2016 Susquehanna Steam Electric Station, Unit 2 - RAI Regarding Temporary Change of Unit 2, Technical Specifications 3.7.1 & 3.8.7 to Allow Replacement of Unit 1, 480 Volt Engineered Safeguard System Load Center Transformers(CAC No. MF7298) ML16245A2052016-09-0101 September 2016 Draft Request for Additional Information Replacement of Load Center Transformers ML16243A0952016-08-30030 August 2016 Draft Request for Additional Information Application for Approval of Indirect Transfer of Control of Licenses ML16060A2302016-03-24024 March 2016 Acceptance of Requested Licensing Action License Amendment Request for Temporary Change of Unit 2 Technical Specifications 3.71 and 3.87 to Allow Replacement of Unit 1 480V Ess Load Center Transformers ML15316A5632015-11-13013 November 2015 Request for Additional Information Regarding Proposed Relief Requests for the Third 10-Year Inservice Inspection Interval(Cac Nos. MF6302 Through MF6307) ML15292A1782015-10-15015 October 2015 TSTF-425 LAR Draft 3rd RAIs ML15230A0802015-08-26026 August 2015 Request for Additional Information Regarding License Amendment Request to Adopt NEI 99-01, Revision 6, EAL Scheme Change ML15209A9742015-08-24024 August 2015 Request for Additional Information License Amendment Request to Adopt Technical Specifications Task Force Traveler (TSTF)-425 ML15230A0462015-08-17017 August 2015 Draft RAIs SSES EAL Scheme Change LAR in Accordance with NEI 99-01 Rev 6 ML15229A2092015-08-17017 August 2015 SSES Draft Request for Additional Information Licensee Request to Adopt TSTF-425 ML15229A2002015-08-17017 August 2015 E-mail from J. Whited to J. Jennings SSES Draft TSTF-425 RAIs ML15183A3502015-07-0202 July 2015 SSES Relief Requests 3RR-19, 3RR-20, and 3RR-21 Draft Identified Information Insufficiencies (TAC Nos. MF6302 Through MF6307) ML15103A3962015-05-22022 May 2015 Request for Additional Information License Amendment Request to Adopt Technical Specifications Task Force Traveler (TSTF)-425 (TAC Nos. MF5151 and MF5152) ML15128A5092015-05-0808 May 2015 E-mail from J. Whited to D. Filchner SSES Draft Request for Additional Information LAR for Implementation of TSTF-425 ML15128A5162015-05-0808 May 2015 SSES Draft Request for Additional Information LAR for Implementation of TSTF-425 ML15008A4702015-01-30030 January 2015 Request for Additional Information Request to Revise Technical Specification 3.4.10, RCS Pressure and Temperature (P/T) Limits. ML15016A2742015-01-16016 January 2015 Draft RAIs License Amendment Request for Change to TS 3.4.10 P/T Limits (TAC Nos. MF4597 and MF45980) ML15016A2722015-01-16016 January 2015 E-mail from J. Whited to D. Filchner Draft RAIs License Amendment Request for Change to TS 3.4.10 P/T Limits (TAC Nos. MF4597 and MF45980) ML14343A9842015-01-0808 January 2015 Request for Additional Information Relief Request 4RR-01 ML14345A2412014-12-16016 December 2014 Request for Additional Information Request for Order Approving Indirect Transfer of Control and Conforming License Amendments ML14346A4022014-12-12012 December 2014 Draft RAIs Relief Request 4RR-01 ML14346A4012014-12-12012 December 2014 E-mail from J. Whited to D. Filchner Susquehanna Steam Electric Station Draft RAIs Relief Request 4RR-01 ML14346A1022014-12-12012 December 2014 Draft License Transfer Revised 2nd RAIs ML14346A1002014-12-12012 December 2014 E-mail from J. Whited to R. Sgarro Susquehanna Steam Electric Station Draft License Transfer Revised 2nd RAIs ML14342A8132014-12-0808 December 2014 SSES Units 1 and 2 Draft RAIs Application for Approval of Indirect Transfer of Control of Licenses ML14342A8082014-12-0808 December 2014 E-mail from J. Whited to R. Sgarro (PPL) SSES Units 1 and 2 Draft RAIs Application for Approval of Indirect Transfer of Control of Licenses ML14233A2772014-08-27027 August 2014 Request for Additional Information License Amendment Request to Change the Low Pressure Safety Limit ML14233A3392014-08-21021 August 2014 Draft RAIs for Susquehanna Steam Electric Station Units 1 and 2 License Amendment Request for Changes to the Low Pressure Safety Limits ML13298A7582014-03-0707 March 2014 Request for Additional Information Regarding Request for Changes to Technical Specification Surveillance Requirements to Increase Diesel Generator Minimum Steady State Voltage (TAC ME9607 and ME960) ML13298A7812014-03-0707 March 2014 Request for Additional Information Regarding Request for Changes to Technical Specification Surveillance Requirement 3.8.1.19 to Increase Diesel Generator Minimum Steady State Frequency (TACs ME9609. ML14013A1502014-01-31031 January 2014 Request for Additional Information Regarding Relief Requests for the Fourth 10-Year Inservice Testing Interval 2024-05-07
[Table view] |
Text
December 13, 2007 LICENSEE: PPL Susquehanna, LLC FACILITY: Susquehanna Steam Electric Station, Units 1 and 2
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON OCTOBER 3, 2007, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PPL SUSQUEHANNA, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PPL Susquehanna, LLC, held a telephone conference call on October 3, 2007, to discuss and clarify the staff=s requests for additional information (RAIs) concerning the Susquehanna Steam Electric Station, Units 1 and 2, license renewal application (LRA). provides a listing of the participants and Enclosure 2 contains a listing of the RAIs discussed with the applicant, including a brief description on the status of the items.
The applicant had an opportunity to comment on this summary.
/RA/
Evelyn Gettys, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-387 and 50-388
Enclosures:
- 1. List of Participants
- 2. List of RAIs cc w/encls: See next page
ML072880051 OFFICE LA:DLR PM:RPB1:DLR BC:RPB1:DLR NAME SFigueroa EGettys LLund DATE 11/8/07 11/12/07 12/13/07
TELEPHONE CONFERENCE CALL SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS OCTOBER 3, 2007 PARTICIPANTS AFFILIATIONS Evelyn Gettys U.S. Nuclear Regulatory Commission (NRC)
Peter Barbadoro NRC Phil Qualls NRC Naeem Iqbal NRC Duane Filchner PPL Susquehanna, LLC (PPL)
Mike Detamore PPL David Cassell PPL ENCLOSURE 1
REQUESTS FOR ADDITIONAL INFORMATION (RAIs)
SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION OCTOBER 3, 2007 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PPL Susquehanna, LLC, held a telephone conference call on October 3, 2007, to discuss and clarify the following RAIs concerning the Susquehanna Steam Electric Station (SSES), Units 1 and 2, license renewal application (LRA).
RAI 2.3.3.13-1 LRA drawing LR-M-122, Sheet No. 1, AFire Pumphouse, North & South Gatehouse & Security Control Center Buildings,@ shows the jockey pump and associated components as out of scope (i.e., not colored in green). Section 9.5.1.1 of the SSES, Units 1 and 2 SER (NUREG-0776),
dated April 1981, states that a separate jockey pump automatically maintains the yard fire main pressure. The jockey pump and its associated components appear to have fire protection intended functions required for compliance with 10 CFR 50.48 as stated in 10 CFR 54.4. The staff requests that the applicant verify whether jockey pump and its associated components are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an aging management review (AMR) in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.
Discussion: The applicant agreed to reevaluate the issue of the jockey pumps being in the scope of license renewal.
RAI 2.3.3.13-2 The following LRA drawings show fire protection system components as out of scope (i.e., not colored in green):
LR-M-122 Sheet 1, AFire Pumphouse, North & South Gatehouse & Security Control Center Buildings,@ shows Diesel Oil Day Tank (0T508) vent line and the fill cap-assembly line, piping, fittings, and drains as out of scope (i.e., not colored in green).
LR-M-122 Sheet 2, ATurbine Bldg., Control Structure and Radwaste Building,@ shows several fire suppression systems and components in Turbine Building Units 1 and 2 as out of scope (i.e., not colored in green).
LR-M-122 Sheet 3, AReactor Bldg., Standby D G, River Intake Structure. Service and Admin.
Bldg. & Circ. Water Pumphouse,@ shows several fire suppression systems and components in Turbine Building Units 1 and 2, Circ. Water Pumphouse, and River Intake Structure as out of scope (i.e., not colored in green).
LR-M-122 Sheet 4, ACarbon Dioxide System,@ shows several components as out of scope (i.e.,
not colored in green).
ENCLOSURE 2
The staff requests that the applicant verify whether the above fire suppression systems and components are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If these components are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.
Discussion: Based on the discussion with the applicant, the staff indicated that the response to this RAI is for clarification. The applicant agreed to clarify if these items are in scope of license renewal.
RAI 2.3.3.13-3 Section 9.5.1.2 of the SSES SER (NUREG-0776), dated April 1981, listed sprinkler and standpipe systems provided in the plant areas for fire suppression activities. The sprinkler and standpipe systems are installed in various areas:
! Reactor Core Isolation Cooling Pump Room
! High Pressure Coolant Injection Pump Room
! Heating, Ventilation, and Air-Conditioning Filter Rooms
! Railroad Airlock
! Control Building Auxiliary Rooms
! Condenser Area
! Reactor Feed Pump Turbine
! Turbine Central Area
! Turbine Condenser Gallery
! Turbine Hydro Control Power Room
! North Railroad Bay
! Turbine Condenser Mezzanine
! Diesel Engine Fire Pump Room
! Lower Cable Spreading Room (CSR)
! Upper CSR
! PFP Turbine Room
! Diesel Generator Building
! Charcoal Filters
! Standby Gas Treatment Filters
! Emergency Outside Air Filters
! Centrifuge & Conditioner
! Turbine Pump Area
! Turbine Hydro Seal Oil Unit
! Turbine Lube Oil Area
! Turbine Motor Generator Area
! Turbine Filter Room
! Turbine Moisture Separation Area
! Radwaste Tank Vent Filter Room
! Radwaste Auxiliary Rooms
! Radwaste Controlled Zone Shop
The staff requests that the applicant verify whether the sprinkler and standpipe systems installed in the above areas of the plant are in the scope of license renewal in accordance with 10 CFR 54.4(a) and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.
Discussion: Based on the discussion with the applicant, the staff indicated that the response to this RAI is for clarification. The applicant agreed to clarify if these items are in scope.
RAI 2.3.3.13-5 LRA Table 2.3.3-13 excludes several types of fire protection components that appear in the SSES SER (NUREG-0776), dated April 1981 and/or Fire Protection Review Report. These components are listed below:
! Hose stations
! Spray nozzles (water, CO2/Halon)
! Dikes for oil spill confinement
! Floor drains and curbs for fire-fighting water
! Filter housing
! Strainer housing
! Heater housing
! Chamber housing
! Actuator housing
! Pipe supports
! Halon storage bottles
! Water storage tanks
! Buried outside diesel fuel storage tanks
! Heat exchanger (bonnet)
! Turbocharger
! Lubricating oil collecting system components (reactor coolant pump)
! Engine intake and exhaust silencers/muffler (diesel driven fire pump)
! Manual smoke removal systems and their associated components (control structure including CSRs)
The staff requests that the applicant verify whether the components listed above should be included in LRA Table 2.3.3.13. If they are excluded from the scope of license renewal and not subject to an AMR, the staff requests that the applicant provide justification for the exclusion.
Discussion: Based on the discussion with the applicant, the staff indicated that the response to this RAI is for clarification. The applicant agreed to clarify what determines when the halon storage bottles are replaced, and to clarify if the listed components are in the scope of license renewal.
Memo to Susquehanna Steam Electric Station from E. Gettys dated December 13, 2007 DISTRIBUTION:
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON OCTOBER 3, 2007, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PPL SUSQUEHANNA, LLC, CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION HARD COPY:
DLR RF E-MAIL:
PUBLIC SSmith (srs3)
SDuraiswamy RidsNrrDlr RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsNrrDlrReba RidsNrrDlrRebb RidsNrrDciCvib RidsNrrDciCpnb RidsNrrDraAfpb RidsNrrDeEmcb RidsNrrDeEeeb RidsNrrDssSrxb RidsNrrDssSbpb RidsNrrDssScvb RidsOgcMailCenter
RGuzman BRogers EGettys
Susquehanna Steam Electric Station, Units 1 and 2 cc:
Cornelius J. Gannon Steven M. Cook Vice President - Nuclear Operations Manager - Quality Assurance PPL Susquehanna, LLC PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467 Berwick, PA 18603-0467 Robert M. Paley Luis A. Ramos General Manager - Plant Support Community Relations Manager, PPL Susquehanna, LLC Susquehanna 769 Salem Blvd., NUCSB2 PPL Susquehanna, LLC Berwick, PA 18603-0467 634 Salem Blvd., SSO Berwick, PA 18603-0467 Rocco R. Sgarro Manager - Nuclear Regulatory Affairs Bryan A. Snapp, Esq.
PPL Susquehanna, LLC Associate General Counsel Two North Ninth Street, GENPL4 PPL Services Corporation Allentown, PA 18101-1179 Two North Ninth Street, GENTW3 Allentown, PA 18101-1179 Walter E. Morrissey Supervising Engineer Supervisor - Document Control Services Nuclear Regulatory Affairs PPL Susquehanna, LLC PPL Susquehanna, LLC Two North Ninth Street, GENPL4 769 Salem Blvd., NUCSA4 Allentown, PA 18101-1179 Berwick, PA 18603-0467 Richard W. Osborne Michael H. Crowthers Allegheny Electric Cooperative, Inc.
Supervising Engineer 212 Locust Street Nuclear Regulatory Affairs P.O. Box 1266 PPL Susquehanna, LLC Harrisburg, PA 17108-1266 Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Director, Bureau of Radiation Protection Pennsylvania Department of Ronald E. Smith Environmental Protection General Manager - Site Preparedness Rachel Carson State Office Building and Services P.O. Box 8469 PPL Susquehanna, LLC Harrisburg, PA 17105-8469 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467
Susquehanna Steam Electric Station, Units 1 and 2 cc:
Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 35, NUCSA4 Berwick, PA 18603-0035 Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Board of Supervisors Salem Township P.O. Box 405 Berwick, PA 18603-0035 Dr. Judith Johnsrud National Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803