October 21, 2008 LICENSEE: PPL Susquehanna, LLC FACILITY: Susquehanna Steam Electric Station, Units 1 and 2

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON OCTOBER 8, 2008, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PPL SUSQUEHANNA, LLC, CONCERNING DRAFT REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PPL Susquehanna, LLC held a telephone conference call on October 8, 2008, to discuss and clarify the staffs draft request for additional information (D-RAI) concerning the Susquehanna Steam Electric Station, Units 1 and 2, license renewal application. The telephone conference call was useful in clarifying the intent of the staffs D-RAI. provides a listing of the participants and Enclosure 2 contains a listing of the D-RAI discussed with the applicant, including a brief description on the status of the items.

The applicant had an opportunity to comment on this summary.

\RA\

Evelyn Gettys, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-387 and 50-388

Enclosures:

As stated cc w/encls: See next page

ML082890152 OFFICE LA:DLR PM:RPB1:DLR BC: RPB1:DLR NAME IKing EGettys DPelton DATE 10/17/08 10/21/08 10/21/08

TELEPHONE CONFERENCE CALL SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS October 8, 2008 PARTICIPANTS AFFILIATIONS Evelyn Gettys U.S. Nuclear Regulatory Commission (NRC)

John Fair NRC On Yee NRC C. Yang NRC Duane Filchner PPL Susquehanna, LLC (PPL)

Dave Flyte PPL Jeff Weik PPL Gary Stevens ISI ENCLOSURE 1

DRAFT REQUEST FOR ADDITIONAL INFORMATION SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION October 8, 2008 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PPL Susquehanna, LLC held a telephone conference call on October 8, 2008, to discuss and clarify the following draft request for additional information (D-RAI) concerning the Susquehanna Steam Electric Station (SSES), Units 1 and 2 license renewal application (LRA).

D-RAI 4.3-8 Section 4.3.2 of the LRA discusses the evaluation of the reactor pressure vessel (RPV) internals. The LRA indicates that structural evaluations were performed to address the effects of operation under extended power uprate conditions and the extended period of operation to 60 years. Explain how the number of reactor design transient cycles for 60 years of plant operation was determined for the analysis of the RPV internals.

Discussion: The applicant indicated that the question is clear. This D-RAI will be sent as a formal RAI.

D-RAI 4.3-9 Section 4.3.3 of the LRA discusses the evaluation of the effects of the reactor coolant environment on the fatigue life of components and piping. Table 4.3-3 provides the 60-year environmental cumulative usage factor (CUF) for each component evaluated. Provide a summary of the environmental factor (Fen) calculation for each component analyzed; including the values of oxygen level, temperature and strain rate used in the calculations. Also provide the basis for oxygen level, temperature and strain rate values used in the Fen calculations.

Discussion: The applicant indicated that the question is clear. This D-RAI will be sent as a formal RAI.

D-RAI 4.3-10 Table 4.3-2 of the LRA provides the 60-year CUF projections for the RPV shell at the shroud support for both units. List the transients that are the most significant contributors to the CUFs of both units. Discuss the fatigue analyses that were performed for the shroud support locations. Also include a discussion of any conservative assumptions that may have been used in the analyses.

Discussion: The applicant indicated that the question is clear. This D-RAI will be sent as a formal RAI.

ENCLOSURE 2

D-RAI 4.3-11 The August 1, 2008, response to RAI B.3.1-2 indicates the FatiguePro software is used for stress-based fatigue (SBF) monitoring of the feedwater nozzle forgings, feedwater nozzle safe ends, and the control rod drive penetrations. The response to RAI B.3.1-1 also indicates that the SBF monitoring methodology was benchmarked against the relevant design basis stress report for each component to ensure valid fatigue monitoring program fatigue results.

a. Describe the procedure used to benchmark the SBF monitoring locations against the relevant design reports. List the transients used for the benchmarking and indicate the design fatigue usage associated with each transient.
b. Discuss how the SSES SBF monitoring addresses the concern raised in proposed Regulatory Information Summary, Fatigue Analysis of Nuclear Power Plant Components, May 1, 2008 (73 FR 24094). Indicate whether any additional benchmarking of the SSES SBF monitoring is planned.

Discussion: The applicant indicated that the question is clear. This D-RAI will be sent as a formal RAI.

Letter to PPL Susquehanna, LLC from E. Gettys, dated October 21, 2008 DISTRIBUTION:

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON OCTOBER 8, 2008, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PPL SUSQUEHANNA, LLC, CONCERNING DRAFT REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION HARD COPY:

DLR RF E-MAIL:

PUBLIC RidsNrrDlr RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsNrrDlrReba RidsNrrDlrRebb RidsNrrDciCvib RidsNrrDciCpnb RidsNrrDraAfpb RidsNrrDeEmcb RidsNrrDeEeeb RidsNrrDssSrxb RidsNrrDssSbpb RidsNrrDssScvb RidsOgcMailCenter


EGettys FJaxheimer

Susquehanna Steam Electric Station, Units 1 and 2 cc:

Cornelius J. Gannon Michael H. Rose Vice President - Nuclear Operations Manager - Quality Assurance PPL Susquehanna, LLC PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467 Joseph J. Scopelliti Robert M. Paley Community Relations Manager, General Manager - Plant Support Susquehanna PPL Susquehanna, LLC PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 634 Salem Blvd., SSO Berwick, PA 18603-0467 Berwick, PA 18603-0467 Rocco R. Sgarro Bryan A. Snapp, Esq.

Manager - Nuclear Regulatory Affairs Associate General Counsel PPL Susquehanna, LLC PPL Services Corporation Two North Ninth Street, GENPL4 Two North Ninth Street, GENTW3 Allentown, PA 18101-1179 Allentown, PA 18101-1179 Supervisor - Nuclear Regulatory Affairs Document Control Services PPL Susquehanna, LLC PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Two North Ninth Street, GENPL4 Berwick, PA 18603-0467 Allentown, PA 18101-1179 Michael H. Crowthers Richard W. Osborne Supervisor - Nuclear Regulatory Affairs Allegheny Electric Cooperative, Inc.

PPL Susquehanna, LLC 212 Locust Street Two North Ninth Street, GENPL4 P.O. Box 1266 Allentown, PA 18101-1179 Harrisburg, PA 17108-1266 Ronald E. Smith Director, Bureau of Radiation Protection General Manager - Site Preparedness Pennsylvania Department of and Services Environmental Protection PPL Susquehanna, LLC Rachel Carson State Office Building 769 Salem Blvd., NUCSA4 P.O. Box 8469 Berwick, PA 18603-0467 Harrisburg, PA 17105-8469 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 35, NUCSA4 Berwick, PA 18603-0035

Susquehanna Steam Electric Station, Units 1 and 2 cc:

Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Berwick, PA 18603-0467 Board of Supervisors Salem Township P.O. Box 405 Berwick, PA 18603-0035 Dr. Judith Johnsrud National Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803