December 7, 1992

. PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE -- PN0-IV-92-042 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information is as initially received without verification or evaluation, and is basically all that is known by the Region IV staff on this date.

FACILITY: Licensee Emergency Classification:

River Bend Station Notification of Unusual Event Gulf States Utilities Alert Docket: 50-458 Site Area Emergency General Emergency

_X_ Not Applicable

SUBJECT:

PLANT SHUTDOWN GREATER THAN 72 HOURS On December 6, at 5:30 p.m., the licensee manually scrammed the reactor to complete a planned shutdown. The outage was scheduled to replace the Reactor Recirculation Pump B seal package. The licensee had indications of a degraded inboard seal. The outboard seal functioned correctly, therefore there was no increase in leakage from the pump. The scope of outage work also includes troubleshooting and repairing the CHC pressure regulator, replacing a pedestal sump pump, repairing secondary plant steam leaks, and repairing a generator hydrogen seal oil system leak. Depending on the conditions that the licensee finds in the pump seal, the outage scope may by increased La include the Recirculation Pump A seal package. The licensee plans to begin plant start up on December 11, 1992.

The state of Louisiani will be informed. -

Region IV received confirmation of this occurrence from the resident inspector at 7:45 a.m., on December 7, 1992. Region IV has informed EDO, NRR, and PA.

l l This information has been confirmed with a licensee representative.

l CONTACT: Jim Gagliardo, Region IV (817) 860-8270.

i l

RIV P/C/DRP D: RSLO %

4)

JEG' 1ardo;1t ABB ch CAHackney JLFfilhoan 12/7 12/7/92 12/7/92 12/7/92

\ o j

l 10006' 9212110109 921207 PDR I&E PNO-IV-92-042 PDR I

r

  • t~

DISfRIBUTION:

OWFN NMBE FAX L-ST MAIL: DCS (Orig. IE34)

Chairman Selin OCA NMSS AE00 INPO PDR DOT (Transp. Only)

Comm. Rogers OGC NRR 1RM NSAC Comm. Curtiss PA SLITP LSSA I.21 EWW Comm. Remick OE NL Licensee OlG Comm. de Planque RES EDO l

l