Letter Sequence Other |
---|
|
Results
Other: ML091950440, ML092090231, ML093490004, ML102150123, ML102150124, ML102150125, ML102150126, ML102150127, ML102150128, NRC-09-0022, Proposed License Amendment to Revise the Degraded Voltage Function Requirements of Technical Specification Table 3.3.8.1-1 to Reflect Undervoltage Backfit Modification
|
MONTHYEARNRC-09-0022, Proposed License Amendment to Revise the Degraded Voltage Function Requirements of Technical Specification Table 3.3.8.1-1 to Reflect Undervoltage Backfit Modification2009-06-10010 June 2009 Proposed License Amendment to Revise the Degraded Voltage Function Requirements of Technical Specification Table 3.3.8.1-1 to Reflect Undervoltage Backfit Modification Project stage: Other ML0919504402009-07-13013 July 2009 Proposed LAR to Revise Degraded Voltage Function Requirements of TS Table 3.3.8.1-1 to Reflect Undervoltage Backfit Modification - ME1477 Project stage: Other ML0920902312009-07-27027 July 2009 Email Fermi 2 LAR - Degraded Voltage Function - ME1477 Project stage: Other ML0930702942009-09-16016 September 2009 Fermi 2 - Response to Request for Additional Information Regarding the Proposed License Amendment to Revise the Degraded Voltage Function Requirements of Technical Requirements of TS Table 3.3.8.1-1 to Reflect Undervoltage Backfit Modificat Project stage: Response to RAI ML0934900042009-12-14014 December 2009 E-mail to A. Hassoun and R. W. Johnson - LAR to Revise Degraded Voltage Function Requirements of TS Table 3.3.8.1-1 to Reflect Undervoltage Backfit Modification Project stage: Other ML1003506682010-02-24024 February 2010 RAI, Amendment Request to Revise the Degraded Voltage Function in the TS Table 3.3.8.1-1, ME1477 Project stage: RAI ML1021501232010-07-14014 July 2010 Fermi 2, Design Calculation Cover Sheet, DC-0919 Vol 1 DCD 1, Rev. 0, Undervoltage Relays Setpoints. Project stage: Other ML1021404292010-07-23023 July 2010 Fermi 2, Response to Request for Additional Information Regarding the Proposed License Amendment to Revise the Degraded Voltage Function Requirements of Technical Specification Table 3.3.8.1-1 to Reflect Undervoltage Backfit Modification Project stage: Response to RAI ML1021501282010-07-23023 July 2010 Drawing EDP-35621.B005, Rev. a, Document Schematic Diagram, 4160V Ess Buses #64B & 64C - Load Shedding Strings. Project stage: Other ML1021501272010-07-23023 July 2010 Drawing EDP-35621.B012, Rev. a, Functional Logic Diagram, Operation of Power Line Feed & Tie Breaker 4160V Buses 65F & 14ED. Project stage: Other ML1021501262010-07-23023 July 2010 Drawing EDP-35621.B011, Rev. a, Functional Logic Diagram Operation of Power Line Feed & Tie Breakers 4160V Busses 65E & 13EC. Project stage: Other ML1021501252010-07-23023 July 2010 Drawing EDP-35621.B010, Rev. a, Functional Logic Diagram. Operation of Power Line Feed & Tie Breakers, 4160V Busses # 64C & 12EB. Project stage: Other ML1021501242010-07-23023 July 2010 Drawing EDP-35621.B009, Rev. a, Functional Logic Diagram, Operation of Power Line Feed & Tie Breakers, 4160V Buses #64B & 11EA. Project stage: Other ML1027701152010-09-27027 September 2010 Degraded Voltage Setpoint As-Found Values Project stage: Request NRC-10-0073, Transmittal of Revised Design Calculations for Setpoint Evaluation of Degraded Voltage Functions in Technical Specification Table 3.3.8.1-12010-10-0404 October 2010 Transmittal of Revised Design Calculations for Setpoint Evaluation of Degraded Voltage Functions in Technical Specification Table 3.3.8.1-1 Project stage: Request ML1027703822010-10-20020 October 2010 Issuance of Amendment to Revise Degraded Voltage Function to Reflect Modification Project stage: Approval 2010-10-20
[Table View] |
Similar Documents at Fermi |
---|
Category:Letter type:NRC
MONTHYEARNRC-24-0007, Report of Changes to Quality Assurance Program for Radioactive Material Packages2024-01-12012 January 2024 Report of Changes to Quality Assurance Program for Radioactive Material Packages NRC-24-0002, Clarification for Request for Additional Information Responses for License Amendment Request to Revise Technical Specification 3.8.1, AC Sources - Operating, Surveillance Requirement SR 3.8.1.122024-01-12012 January 2024 Clarification for Request for Additional Information Responses for License Amendment Request to Revise Technical Specification 3.8.1, AC Sources - Operating, Surveillance Requirement SR 3.8.1.12 NRC-23-0079, Transmittal of Revision 1 of the Core Operating Limits Report for Cycle 222023-12-14014 December 2023 Transmittal of Revision 1 of the Core Operating Limits Report for Cycle 22 NRC-23-0077, Submittal of Revision 50 to the Fermi 2 Radiological Emergency Response Preparedness Plan2023-12-0404 December 2023 Submittal of Revision 50 to the Fermi 2 Radiological Emergency Response Preparedness Plan NRC-23-0073, Guarantee of Payment of Deferred Premiums2023-11-29029 November 2023 Guarantee of Payment of Deferred Premiums NRC-23-0071, Response to Request for Additional Information (RAI) for Exigent License Amendment Request for Revision of Technical Specification (TS) 3.8.1 AC Sources - Operating2023-10-13013 October 2023 Response to Request for Additional Information (RAI) for Exigent License Amendment Request for Revision of Technical Specification (TS) 3.8.1 AC Sources - Operating NRC-23-0062, Response to Request for Additional Information for License Amendment Request to Revise Technical Specification 3.8.1, AC Sources - Operating, Surveillance Requirement SR 3.8.1.122023-10-12012 October 2023 Response to Request for Additional Information for License Amendment Request to Revise Technical Specification 3.8.1, AC Sources - Operating, Surveillance Requirement SR 3.8.1.12 NRC-23-0068, Exigent License Amendment Request for Revision of Technical Specification (TS) 3.8.1 AC Sources - Operating2023-09-28028 September 2023 Exigent License Amendment Request for Revision of Technical Specification (TS) 3.8.1 AC Sources - Operating NRC-23-0064, Additional Supplemental Information to Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS)2023-09-11011 September 2023 Additional Supplemental Information to Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS) NRC-23-0057, Independent Spent Fuel Storage Installation Cask Registration2023-08-31031 August 2023 Independent Spent Fuel Storage Installation Cask Registration NRC-23-0054, Enrico Fermi Atomic Power Plant, Unit 1, Annual Report for Period Ending June 30 20232023-08-31031 August 2023 Enrico Fermi Atomic Power Plant, Unit 1, Annual Report for Period Ending June 30 2023 NRC-23-0056, Inservice Testing (IST) Program for the Fourth 10-Year Inspection Interval2023-08-31031 August 2023 Inservice Testing (IST) Program for the Fourth 10-Year Inspection Interval NRC-23-0061, Clarification for NRC-23-0059, Response to Request for Additional Information for Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water..2023-08-30030 August 2023 Clarification for NRC-23-0059, Response to Request for Additional Information for Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water.. NRC-23-0059, Response to Request for Additional Information Exigent License Amendment Request for Technical Specification 3.7.2,Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS)2023-08-25025 August 2023 Response to Request for Additional Information Exigent License Amendment Request for Technical Specification 3.7.2,Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS) NRC-23-0060, Supplemental Information to Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS)2023-08-25025 August 2023 Supplemental Information to Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS) NRC-23-0053, Independent Spent Fuel Storage Installation Cask Registration2023-08-23023 August 2023 Independent Spent Fuel Storage Installation Cask Registration NRC-23-0050, Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS)2023-08-10010 August 2023 Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS) NRC-23-0048, Independent Spent Fuel Storage Installation Cask Registration2023-08-0101 August 2023 Independent Spent Fuel Storage Installation Cask Registration NRC-23-0049, Request for Enforcement Discretion for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS)2023-07-24024 July 2023 Request for Enforcement Discretion for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS) NRC-23-0043, Independent Spent Fuel Storage Installation, Cask Registration2023-06-27027 June 2023 Independent Spent Fuel Storage Installation, Cask Registration NRC-23-0020, License Amendment Request for a Risk Informed Approach to ECCS Strainer Performance2023-06-13013 June 2023 License Amendment Request for a Risk Informed Approach to ECCS Strainer Performance NRC-23-0039, Request for Enforcement Discretion for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS)2023-06-0606 June 2023 Request for Enforcement Discretion for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS) NRC-23-0030, Inservice Inspection-Nondestructive Examination (ISI-NDE) Program for the Fourth 10-Year Inspection Interval2023-06-0505 June 2023 Inservice Inspection-Nondestructive Examination (ISI-NDE) Program for the Fourth 10-Year Inspection Interval NRC-23-0029, Snubber Program for the Fourth 10-Year Testing Interval2023-06-0505 June 2023 Snubber Program for the Fourth 10-Year Testing Interval NRC-23-0037, 56542-EN 56542 - Fermi2023-05-26026 May 2023 56542-EN 56542 - Fermi NRC-23-0031, Response to NRC Request from Audit of License Amendment Request to Revise Technical Specification 3.8.1, AC Sources -Operating,' Emergency Diesel Generator Voltage and Frequency Surveillance Requirements2023-05-16016 May 2023 Response to NRC Request from Audit of License Amendment Request to Revise Technical Specification 3.8.1, AC Sources -Operating,' Emergency Diesel Generator Voltage and Frequency Surveillance Requirements NRC-23-0002, License Amendment Request to Revise Technical Specification 3.8.1, AC Sources - Operating, Surveillance Requirement SR 3.8.1.122023-05-0505 May 2023 License Amendment Request to Revise Technical Specification 3.8.1, AC Sources - Operating, Surveillance Requirement SR 3.8.1.12 NRC-23-0010, License Amendment Request to Correct Non-Conservative Technical Specification 3.4.5, RCS Pressure Isolation Valve (PIV) Leakage2023-05-0505 May 2023 License Amendment Request to Correct Non-Conservative Technical Specification 3.4.5, RCS Pressure Isolation Valve (PIV) Leakage NRC-23-0017, Annual Radioactive Effluent Release Report and Radiological Environmental Operating Report2023-04-28028 April 2023 Annual Radioactive Effluent Release Report and Radiological Environmental Operating Report NRC-23-0025, Submittal of 2022 Safety Relief Valve Challenge Report, Main Steam Bypass Lines Report, and ECCS Cooling Performance Evaluation Model Changes or Errors Report2023-04-28028 April 2023 Submittal of 2022 Safety Relief Valve Challenge Report, Main Steam Bypass Lines Report, and ECCS Cooling Performance Evaluation Model Changes or Errors Report NRC-23-0018, Annual Non-Radiological Environmental Operating Report2023-04-26026 April 2023 Annual Non-Radiological Environmental Operating Report NRC-23-0024, Levels and Sources of Property Insurance Coverage2023-04-0303 April 2023 Levels and Sources of Property Insurance Coverage NRC-23-0021, ISFSI, Decommissioning Funding Plan Update2023-03-30030 March 2023 ISFSI, Decommissioning Funding Plan Update NRC-23-0016, Decommissioning Funding Status Report2023-03-30030 March 2023 Decommissioning Funding Status Report NRC-23-0015, Decommissioning Funding Status Report for Fermi 12023-03-30030 March 2023 Decommissioning Funding Status Report for Fermi 1 NRC-23-0011, License Renewal Commitment 7c: Transmittal of Core Plate Hold-Down Bolt Analysis2023-03-0707 March 2023 License Renewal Commitment 7c: Transmittal of Core Plate Hold-Down Bolt Analysis NRC-22-0026, License Amendment Request to Revise Technical Specification 3.8.1, AC Sources - Operating, Emergency Diesel Generator Voltage and Frequency Surveillance Requirements2022-12-16016 December 2022 License Amendment Request to Revise Technical Specification 3.8.1, AC Sources - Operating, Emergency Diesel Generator Voltage and Frequency Surveillance Requirements NRC-22-0051, DTE Electric Company - Guarantee of Payment of Deferred Premiums2022-11-29029 November 2022 DTE Electric Company - Guarantee of Payment of Deferred Premiums NRC-22-0052, Replacement Files for Submittal of Revision 24 to the Fermi 2 Updated Final Safety Analysis Report (UFSAR) Through EIE on November 9, 20222022-11-17017 November 2022 Replacement Files for Submittal of Revision 24 to the Fermi 2 Updated Final Safety Analysis Report (UFSAR) Through EIE on November 9, 2022 NRC-22-0046, Submittal of Biennial Review of the Fermi 1 Safety Analysis Report2022-11-14014 November 2022 Submittal of Biennial Review of the Fermi 1 Safety Analysis Report NRC-22-0041, Evacuation Time Estimate Report2022-10-0505 October 2022 Evacuation Time Estimate Report NRC-22-0033, Enrico Fermi Atomic Power Plant, Unit 1 - Annual Report for Period Ending June 30, 20222022-08-29029 August 2022 Enrico Fermi Atomic Power Plant, Unit 1 - Annual Report for Period Ending June 30, 2022 NRC-22-0030, Inservice Inspection Summary Report2022-08-10010 August 2022 Inservice Inspection Summary Report NRC-22-0023, Application to Revise Technical Specifications to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements2022-08-0404 August 2022 Application to Revise Technical Specifications to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements NRC-22-0022, Annual Non-Radiological Environmental Operating Report2022-04-29029 April 2022 Annual Non-Radiological Environmental Operating Report NRC-22-0021, Annual Radioactive Effluent Release Report and Radiological Environmental Operating Report2022-04-29029 April 2022 Annual Radioactive Effluent Release Report and Radiological Environmental Operating Report NRC-22-0020, Enrico Fermi Atomic Power Plant, Unit No. 1 & Fermi 2 Power Plant - 10 CFR 20.2206 Report of Individual Monitoring2022-04-28028 April 2022 Enrico Fermi Atomic Power Plant, Unit No. 1 & Fermi 2 Power Plant - 10 CFR 20.2206 Report of Individual Monitoring NRC-22-0003, Submittal of 2021 Safety Relief Valve Challenge Report, Main Steam Bypass Lines Report, and ECCS Cooling Performance Evaluation Model Changes or Errors Report2022-04-26026 April 2022 Submittal of 2021 Safety Relief Valve Challenge Report, Main Steam Bypass Lines Report, and ECCS Cooling Performance Evaluation Model Changes or Errors Report NRC-22-0019, Submittal of the National Pollutant Discharge Elimination System Permit Application for Reissuance2022-04-0404 April 2022 Submittal of the National Pollutant Discharge Elimination System Permit Application for Reissuance NRC-22-0011, Enrico Fermi Atomic Power Plant, Unit No. 1 - Decommissioning Funding Status Report2022-03-31031 March 2022 Enrico Fermi Atomic Power Plant, Unit No. 1 - Decommissioning Funding Status Report 2024-01-12
[Table view] Category:License-Application for Facility Operating License (Amend/Renewal) DKT 50
MONTHYEARNRC-23-0068, Exigent License Amendment Request for Revision of Technical Specification (TS) 3.8.1 AC Sources - Operating2023-09-28028 September 2023 Exigent License Amendment Request for Revision of Technical Specification (TS) 3.8.1 AC Sources - Operating NRC-23-0055, NRR E-mail Capture - (External Sender) Fermi 2 Power Plant, Emergency Application to Revise Technical Specifications to Adopt TSTF 568, Revise Applicability of BWR TS 3.6.2.5 and TS 3.6.3.2 - Updated Clean Sheet for NRC-23-00552023-08-16016 August 2023 NRR E-mail Capture - (External_Sender) Fermi 2 Power Plant, Emergency Application to Revise Technical Specifications to Adopt TSTF 568, Revise Applicability of BWR TS 3.6.2.5 and TS 3.6.3.2 - Updated Clean Sheet for NRC-23-0055 ML23227A2212023-08-15015 August 2023 Emergency Application to Revise Technical Specifications to Adopt TSTF 568, Revise Applicability of BWR TS 3.6.2.5 and TS 3.6.3.2 NRC-23-0050, Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS)2023-08-10010 August 2023 Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS) NRC-23-0020, License Amendment Request for a Risk Informed Approach to ECCS Strainer Performance2023-06-13013 June 2023 License Amendment Request for a Risk Informed Approach to ECCS Strainer Performance NRC-23-0002, License Amendment Request to Revise Technical Specification 3.8.1, AC Sources - Operating, Surveillance Requirement SR 3.8.1.122023-05-0505 May 2023 License Amendment Request to Revise Technical Specification 3.8.1, AC Sources - Operating, Surveillance Requirement SR 3.8.1.12 NRC-23-0010, License Amendment Request to Correct Non-Conservative Technical Specification 3.4.5, RCS Pressure Isolation Valve (PIV) Leakage2023-05-0505 May 2023 License Amendment Request to Correct Non-Conservative Technical Specification 3.4.5, RCS Pressure Isolation Valve (PIV) Leakage NRC-22-0026, License Amendment Request to Revise Technical Specification 3.8.1, AC Sources - Operating, Emergency Diesel Generator Voltage and Frequency Surveillance Requirements2022-12-16016 December 2022 License Amendment Request to Revise Technical Specification 3.8.1, AC Sources - Operating, Emergency Diesel Generator Voltage and Frequency Surveillance Requirements NRC-22-0023, Application to Revise Technical Specifications to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements2022-08-0404 August 2022 Application to Revise Technical Specifications to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements ML22101A0472022-04-0404 April 2022 Submittal of Application for the Renewal of National Pollutant Discharge Elimination System (NPDES) Permit NRC-21-0001, License Amendment Request to Revise Technical Specifications to Remove Obsolete Information, Make Minor Corrections, and Make Miscellaneous Editorial Changes2021-03-31031 March 2021 License Amendment Request to Revise Technical Specifications to Remove Obsolete Information, Make Minor Corrections, and Make Miscellaneous Editorial Changes NRC-20-0038, Application to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules2020-10-28028 October 2020 Application to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules NRC-20-0040, Response to NRC Request from Audit of License Amendment Request to Revise Technical Specifications to Change Surveillance Intervals to Accommodate a 24-Month Fuel Cycle2020-06-23023 June 2020 Response to NRC Request from Audit of License Amendment Request to Revise Technical Specifications to Change Surveillance Intervals to Accommodate a 24-Month Fuel Cycle NRC-20-0032, Application to Revise Technical Specifications to Adopt TSTF-563, Revise Instrument Testing Definitions to Incorporate the Surveillance Frequency Control Program2020-06-0505 June 2020 Application to Revise Technical Specifications to Adopt TSTF-563, Revise Instrument Testing Definitions to Incorporate the Surveillance Frequency Control Program NRC-19-0075, License Amendment Request - Proposed Revision to Technical Specifications for Secondary Containment Surveillance Requirements2019-12-0606 December 2019 License Amendment Request - Proposed Revision to Technical Specifications for Secondary Containment Surveillance Requirements NRC-19-0054, DTE Energy Company - License Amendment Request to Revise Technical Specifications to Change Surveillance Intervals to Accommodate a 24-Month Fuel Cycle2019-11-0808 November 2019 DTE Energy Company - License Amendment Request to Revise Technical Specifications to Change Surveillance Intervals to Accommodate a 24-Month Fuel Cycle NRC-19-0028, License Amendment Request - Proposed Revision to Technical Specifications in Response to GE Energy - Nuclear 10 CFR Part 21 Safety Communication SC05-032019-09-0505 September 2019 License Amendment Request - Proposed Revision to Technical Specifications in Response to GE Energy - Nuclear 10 CFR Part 21 Safety Communication SC05-03 NRC-19-0001, License Amendment Request to Revise Technical Specification 3.3.5.3, Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation2019-02-27027 February 2019 License Amendment Request to Revise Technical Specification 3.3.5.3, Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation NRC-19-0002, Application to Revise Technical Specifications to Adopt TSTF-564, Safety Limit MCPR2019-02-0808 February 2019 Application to Revise Technical Specifications to Adopt TSTF-564, Safety Limit MCPR NRC-17-0063, License Amendment Request for Adoption of TSTF-484, Rev. 0, Use of TS 3.10.1 for Scram Time Testing Activities.2017-10-0909 October 2017 License Amendment Request for Adoption of TSTF-484, Rev. 0, Use of TS 3.10.1 for Scram Time Testing Activities. NRC-17-0067, Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control.2017-08-31031 August 2017 Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control. ML17237A1762017-08-24024 August 2017 License Amendment Request to Revise Technical Specifications to Eliminate Main Steam Line Radiation Monitor Reactor Trip and Primary Containment Isolation System Group 1 Isolation Functions NRC-17-0056, Supplemental Information Regarding License Amendment Request to Revise Technical Specifications to Adopt TSTF-545, Revision 32017-08-15015 August 2017 Supplemental Information Regarding License Amendment Request to Revise Technical Specifications to Adopt TSTF-545, Revision 3 NRC-17-0044, License Amendment Request to Revise Technical Specification 5.5.7, Ventilation Filter Testing Program, to Be Consistent with Standard Technical Specifications2017-08-14014 August 2017 License Amendment Request to Revise Technical Specification 5.5.7, Ventilation Filter Testing Program, to Be Consistent with Standard Technical Specifications NRC-17-0025, License Amendment Request to Revise Technical Specification Section 3.7.2 for Emergency Equipment Cooling Water / Emergency Equipment Service Water System and Ultimate Heat Sink2017-07-17017 July 2017 License Amendment Request to Revise Technical Specification Section 3.7.2 for Emergency Equipment Cooling Water / Emergency Equipment Service Water System and Ultimate Heat Sink NRC-17-0010, License Amendment Request to Revise Technical Specifications for Emergency Core Cooling System Instrumentation and Reactor Core Isolation Cooling System Instrumentation2017-02-23023 February 2017 License Amendment Request to Revise Technical Specifications for Emergency Core Cooling System Instrumentation and Reactor Core Isolation Cooling System Instrumentation NRC-16-0036, License Amendment Request to Revise Technical Specifications to Adopt TSTF-545, Revision 3, TS Inservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing, Using the Consolidated Line Item Improvement Pro2016-07-25025 July 2016 License Amendment Request to Revise Technical Specifications to Adopt TSTF-545, Revision 3, TS Inservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing, Using the Consolidated Line Item Improvement Proces NRC-16-0006, License Amendment Request to Revise Integrated Leak Rate Test (Type a) and Type C Test Intervals2016-03-22022 March 2016 License Amendment Request to Revise Integrated Leak Rate Test (Type a) and Type C Test Intervals NRC-15-0081, License Renewal Application Update for the Boraflex Monitoring Program2015-09-24024 September 2015 License Renewal Application Update for the Boraflex Monitoring Program NRC-15-0090, License Amendment Request to Revise Technical Specifications to Adopt TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation, Using the Consolidated Line Item Improvement Process2015-09-24024 September 2015 License Amendment Request to Revise Technical Specifications to Adopt TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation, Using the Consolidated Line Item Improvement Process NRC-15-0067, Response to NRC Request for Additional Information for the Review of the License Renewal Application - Set 352015-06-18018 June 2015 Response to NRC Request for Additional Information for the Review of the License Renewal Application - Set 35 NRC-15-0062, Response to NRC Request for Additional Information for the Review of the License Renewal Application - Set 342015-06-0909 June 2015 Response to NRC Request for Additional Information for the Review of the License Renewal Application - Set 34 NRC-15-0044, Response to NRC Request for Additional Information for the Review of the License Renewal Application - Sets 27, 28, 29 and 312015-04-27027 April 2015 Response to NRC Request for Additional Information for the Review of the License Renewal Application - Sets 27, 28, 29 and 31 NRC-15-0030, Response to NRC Request for Additional Information for the Review of the Fermi 2 License Renewal Application - Set 222015-03-19019 March 2015 Response to NRC Request for Additional Information for the Review of the Fermi 2 License Renewal Application - Set 22 NRC-15-0028, Revision to Response to License Renewal Environmental RAI SSSH-12015-02-18018 February 2015 Revision to Response to License Renewal Environmental RAI SSSH-1 NRC-15-0021, License Renewal Application - Response to LR-ISG-2013-012015-02-0505 February 2015 License Renewal Application - Response to LR-ISG-2013-01 NRC-14-0055, License Amendment Request to Revise the Emergency Action Level Scheme for the Emergency Plan2014-10-21021 October 2014 License Amendment Request to Revise the Emergency Action Level Scheme for the Emergency Plan ML14121A5362014-04-24024 April 2014 Fermi 2, License Renewal Application, Page 3.3-2 Through Appendix C, Page C-13 ML14121A5352014-04-24024 April 2014 Fermi 2, License Renewal Application, Cover Through Page 3.3-1 ML14121A5382014-04-24024 April 2014 Fermi 2, License Renewal Application, Appendix D Through Appendix E, Page 3-169 ML14121A5392014-04-24024 April 2014 Fermi 2, License Renewal Application, Appendix E, Page 3-170 Through Page 9-23 NRC-14-0028, License Renewal Application, Appendix E, Page 10-1 Through End2014-04-24024 April 2014 License Renewal Application, Appendix E, Page 10-1 Through End NRC-13-0012, License Amendment Request to Revise Technical Specifications Regarding Control Room Envelope Habitability in Accordance with TSTF-448, Revision 3, Using the Consolidated Line Item Improvement Process2013-04-17017 April 2013 License Amendment Request to Revise Technical Specifications Regarding Control Room Envelope Habitability in Accordance with TSTF-448, Revision 3, Using the Consolidated Line Item Improvement Process NRC-13-0004, License Amendment Request for Measurement Uncertainty Recapture (Mur) Power Uprate2013-02-0707 February 2013 License Amendment Request for Measurement Uncertainty Recapture (Mur) Power Uprate NRC-13-0001, License Amendment Request for Adoption of Technical Specifications Task Force (TSTF) Traveler TSTF-423, Revision 1, Technical Specifications End States, NEDC-32988-A, Using the Consolidated Line Item Improvement Process2013-01-11011 January 2013 License Amendment Request for Adoption of Technical Specifications Task Force (TSTF) Traveler TSTF-423, Revision 1, Technical Specifications End States, NEDC-32988-A, Using the Consolidated Line Item Improvement Process NRC-13-0002, Proposed License Amendment to Revise the Fermi 2 Licensing Bases for Protection from Tornado-Generated Missiles2013-01-11011 January 2013 Proposed License Amendment to Revise the Fermi 2 Licensing Bases for Protection from Tornado-Generated Missiles NRC-12-0037, Proposed License Amendment to Relocate Pressure and Temperature Curves to a Pressure Temperature Limits Report2012-12-21021 December 2012 Proposed License Amendment to Relocate Pressure and Temperature Curves to a Pressure Temperature Limits Report NRC-12-0087, License Amendment Request to Change Name of Licensee from the Detroit Edison Company to DTE Electric Company2012-12-21021 December 2012 License Amendment Request to Change Name of Licensee from the Detroit Edison Company to DTE Electric Company NRC-12-0083, License Amendment Request to Change Licensee Name on the Operating License2012-12-21021 December 2012 License Amendment Request to Change Licensee Name on the Operating License NRC-12-0037, Fermi 2, Proposed License Amendment to Relocate Pressure and Temperature Curves to a Pressure Temperature Limits Report2012-12-21021 December 2012 Fermi 2, Proposed License Amendment to Relocate Pressure and Temperature Curves to a Pressure Temperature Limits Report 2023-09-28
[Table view] Category:Technical Specifications
MONTHYEARML23310A1492023-12-0808 December 2023 Issuance of Amendment No. 227 Regarding Revision of Technical Specification 3.8.1, AC Sources - Operating, Emergency Diesel Generator Voltage and Frequency Surveillance Requirements ML23243A8852023-09-18018 September 2023 Issuance of Amendment No. 225 Regarding Revision of Technical Specifications 3.7.2, Emergency Equipment Cooling Water, Emergency Equipment Service Water and System and Ultimate Heat Sink (Exigent Circumstances) NRC-23-0055, NRR E-mail Capture - (External Sender) Fermi 2 Power Plant, Emergency Application to Revise Technical Specifications to Adopt TSTF 568, Revise Applicability of BWR TS 3.6.2.5 and TS 3.6.3.2 - Updated Clean Sheet for NRC-23-00552023-08-16016 August 2023 NRR E-mail Capture - (External_Sender) Fermi 2 Power Plant, Emergency Application to Revise Technical Specifications to Adopt TSTF 568, Revise Applicability of BWR TS 3.6.2.5 and TS 3.6.3.2 - Updated Clean Sheet for NRC-23-0055 ML23227A2212023-08-15015 August 2023 Emergency Application to Revise Technical Specifications to Adopt TSTF 568, Revise Applicability of BWR TS 3.6.2.5 and TS 3.6.3.2 ML23122A2332023-06-26026 June 2023 Issuance of Amendment No. 223 Regarding Revision of Technical Specifications to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements NRC-23-0039, Request for Enforcement Discretion for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS)2023-06-0606 June 2023 Request for Enforcement Discretion for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water (Eesw) System and Ultimate Heat Sink (UHS) ML21335A2802022-04-0707 April 2022 Issuance of Amendment No. 222 Regarding Revision of Technical Specifications to Remove Obsolete Information, Make Minor Corrections, and Make Several Editorial Changes ML22032A1572022-01-19019 January 2022 Technical Requirements Manual - Vol. 1 Revision 130 Dated 01/19/2022 ML21251A1602021-08-17017 August 2021 Technical Requirements Manual - Vol 1 - (Revision 127 Dated 08/17/2021) ML21053A2022021-02-0101 February 2021 Technical Requirements Manual, Vol 1 - Revision 124 Dated 02/01/2021 ML20233A8382020-10-0505 October 2020 Issuance of Amendment No. 216 - Revision to Technical Specification in Response to GE Energy-Nuclear's 10 CFR Part 21 Safety Communication SC05-03 ML18165A2022018-09-13013 September 2018 Issuance of Amendment Regarding the Adoption of TSTF-484, Use of TS 3.10.1 for Scram Time Testing Activities ML16270A5312016-12-15015 December 2016 Fermi, Unit 2, Preoperational Test, Startup Tests and Other Items ML16069A0062016-04-20020 April 2016 Issuance of Amendment Technical Specifications to Adopt Technical Specifications Task Force - 523, Generic Letter 2008-01, Managing Gas Accumulation ML16054A6372016-04-0505 April 2016 Issuance of Amendment to Revise License Amendment Request to Revise Technical Specification Section 3.5.1, Emergency Core Cooling System - Operating Report ML16039A1212016-02-18018 February 2016 Corrections to Amendment No. 201 Regarding Relocation of Specific Surveillance Frequencies to a Licensee-Controlled Program Based on Technical Specification Task Force (TSTF) Change TSTF-425 ML15233A0842015-09-29029 September 2015 Issuance of Amendment License Amendment Request to Revise the Emergency Action Level Scheme for the Fermi Emergency Plan ML15155B4162015-07-14014 July 2015 Ferm, Uniti 2 - Issuance of Amendment Revise Technical Specifications by Relocating Surveillance Frequencies to Licensee Control in Accordance with Technical Specification Task Force Traveler 425, Revision 3 ML15096A0432015-05-0707 May 2015 Issuance of Amendment Cyber Security Plan Implementation Schedule (Tac No. MF4366) NRC-14-0049, Supplement to License Amendment Request to Revise Technical Specification Surveillance Requirements for Direct Current Batteries2014-06-19019 June 2014 Supplement to License Amendment Request to Revise Technical Specification Surveillance Requirements for Direct Current Batteries ML13364A1312014-02-10010 February 2014 Issuance of Amendment Measurement Uncertainty Recapture Power Uprate ML13346B0672014-02-0404 February 2014 Issuance of Amendment Relocation of Pressure and Temperature Curves to a Pressure Temperature Limits Report ML13112A1422013-05-13013 May 2013 Issuance of Amendment to Revise Technical Specifications to Adopt TSTF-522, Using Consolidated Line Item Improvement Process NRC-13-0004, License Amendment Request for Measurement Uncertainty Recapture (Mur) Power Uprate2013-02-0707 February 2013 License Amendment Request for Measurement Uncertainty Recapture (Mur) Power Uprate NRC-13-0001, License Amendment Request for Adoption of Technical Specifications Task Force (TSTF) Traveler TSTF-423, Revision 1, Technical Specifications End States, NEDC-32988-A, Using the Consolidated Line Item Improvement Process2013-01-11011 January 2013 License Amendment Request for Adoption of Technical Specifications Task Force (TSTF) Traveler TSTF-423, Revision 1, Technical Specifications End States, NEDC-32988-A, Using the Consolidated Line Item Improvement Process NRC-12-0037, Proposed License Amendment to Relocate Pressure and Temperature Curves to a Pressure Temperature Limits Report2012-12-21021 December 2012 Proposed License Amendment to Relocate Pressure and Temperature Curves to a Pressure Temperature Limits Report NRC-12-0037, Fermi 2, Proposed License Amendment to Relocate Pressure and Temperature Curves to a Pressure Temperature Limits Report2012-12-21021 December 2012 Fermi 2, Proposed License Amendment to Relocate Pressure and Temperature Curves to a Pressure Temperature Limits Report NRC-12-0071, Application to Revise Technical Specifications to Adopt TSTF-522, Revise Ventilation System Surveillance Requirements to Operate for 10 Hours Per Month, Using the Consolidated Line Item Improvement Process2012-11-13013 November 2012 Application to Revise Technical Specifications to Adopt TSTF-522, Revise Ventilation System Surveillance Requirements to Operate for 10 Hours Per Month, Using the Consolidated Line Item Improvement Process NRC-12-0005, Proposed License Amendment to Revise the Residual Heat Removal Suppression Pool Cooling Flow Rate in Technical Specification Surveillance Requirement 3.6.2.3.22012-01-10010 January 2012 Proposed License Amendment to Revise the Residual Heat Removal Suppression Pool Cooling Flow Rate in Technical Specification Surveillance Requirement 3.6.2.3.2 NRC-12-0004, Proposed License Amendment to Modify Technical Specification Surveillance Requirements for Safety Relief Valves2012-01-10010 January 2012 Proposed License Amendment to Modify Technical Specification Surveillance Requirements for Safety Relief Valves NRC-11-0049, License Amendment Request for Adoption of Technical Specification Task Force Traveler TSTF-306, Revision 2, Add Action to LCO 3.3.6.1 to Give Option to Isolate the Penetration.2011-12-20020 December 2011 License Amendment Request for Adoption of Technical Specification Task Force Traveler TSTF-306, Revision 2, Add Action to LCO 3.3.6.1 to Give Option to Isolate the Penetration. NRC-11-0030, License Amendment Request for Adoption of Technical Specifications Task Force (TSTF) Traveler TSTF-501, Revision 1, Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control.2011-08-12012 August 2011 License Amendment Request for Adoption of Technical Specifications Task Force (TSTF) Traveler TSTF-501, Revision 1, Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control. NRC-11-0013, License Amendment Request for Adoption of Technical Specification Task Force Traveler TSTF-514, Revision 3, Revise BWR Operability Requirements and Actions for RCS Leakage Instrumentation.2011-04-0808 April 2011 License Amendment Request for Adoption of Technical Specification Task Force Traveler TSTF-514, Revision 3, Revise BWR Operability Requirements and Actions for RCS Leakage Instrumentation. ML1013408512010-05-14014 May 2010 Revised Clean TS Pages NRC-10-0003, Proposed License Amendment to Revise the Core Spray Flow Requirement of Technical Specification Surveillance Tests SR 3.5.1.8 and SR 3.5.2.62010-01-0404 January 2010 Proposed License Amendment to Revise the Core Spray Flow Requirement of Technical Specification Surveillance Tests SR 3.5.1.8 and SR 3.5.2.6 NRC-09-0022, Proposed License Amendment to Revise the Degraded Voltage Function Requirements of Technical Specification Table 3.3.8.1-1 to Reflect Undervoltage Backfit Modification2009-06-10010 June 2009 Proposed License Amendment to Revise the Degraded Voltage Function Requirements of Technical Specification Table 3.3.8.1-1 to Reflect Undervoltage Backfit Modification NRC-08-0061, Proposed License Amendment to Remove Statements Related to Nuclear Power Plant Staff Working Hours in Technical Specification2008-09-12012 September 2008 Proposed License Amendment to Remove Statements Related to Nuclear Power Plant Staff Working Hours in Technical Specification ML0812808342008-06-25025 June 2008 Tech Spec Pages for Amendment 180 Delete the Note Associated with the Performance of Channel Calibration for Primary Containment High Range Radiation Monitor in Technical Specification 3.3.3.1 Surveillance Requirements ML0807900262008-03-17017 March 2008 Issuance of Amendment Technical Specification Change to Emergency Diesel Generator Surveillance Requirements NRC-08-0001, Application for Technical Specification Change Regarding Revision of Control Rod Notch Surveillance Test Frequency and a Clarification of a Frequency Example Using the Consolidated Line Item Improvement Process2008-01-15015 January 2008 Application for Technical Specification Change Regarding Revision of Control Rod Notch Surveillance Test Frequency and a Clarification of a Frequency Example Using the Consolidated Line Item Improvement Process ML0721404442007-08-0101 August 2007 Tech Spec Pages for Amendment Consolidated Line Item Improvement Process (Cllip) for Technical Specification Change (TSTF-427) to Add Limiting Condition for Operation (LCO) 30.9 Regarding the Unavailability of Barriers ML0721407632007-08-0101 August 2007 Technical Specification 3.8.1 Extension of the Completion Time for an Inoperable Diesel Generator Amendment ML0715002322007-04-12012 April 2007 Technical Specifications, Application for Technical Specification Change TSTF-374, Revision to TS 5.5.13 and Associated TS Bases for the Diesel Fuel Oil Testing Programs Using the Consolidated Line Item Improvement Process NRC-07-0012, Proposed License Amendment to Revise the Minimum Emergency Diesel Generator Voltage in Technical Specification 3.8.1 Surveillance Requirements2007-03-19019 March 2007 Proposed License Amendment to Revise the Minimum Emergency Diesel Generator Voltage in Technical Specification 3.8.1 Surveillance Requirements NRC-07-0001, Application for Technical Specification Change (TSTF-427) to Add LCO 3.0.9 Regarding the Unavailability of Barriers Using the Consolidated Line Item Improvement Process2007-01-26026 January 2007 Application for Technical Specification Change (TSTF-427) to Add LCO 3.0.9 Regarding the Unavailability of Barriers Using the Consolidated Line Item Improvement Process ML0622004402006-08-0707 August 2006 Technical Specifications, Changes to Address Issues Related to an Inconsistency That Was Inadvertently Introduced During Conversion to Improved TSs When 1 Per Room Replaced 2 as the Required Channels Per Trip System NRC-06-0044, Response to Request for Additional Information for Revision to License Amendment Request to Revise Technical Specification 3.3.6.1, Primary Containment Isolation Instrumentation2006-07-12012 July 2006 Response to Request for Additional Information for Revision to License Amendment Request to Revise Technical Specification 3.3.6.1, Primary Containment Isolation Instrumentation NRC-06-0040, Proposed License Amendment Request to Extend the Completion Time for Technical Specification 3.8.1 for an Inoperable Emergency Diesel Generator2006-07-12012 July 2006 Proposed License Amendment Request to Extend the Completion Time for Technical Specification 3.8.1 for an Inoperable Emergency Diesel Generator ML0604800392006-02-15015 February 2006 Tech Spec Pages for Amendment 172 Regarding Consolidated Line Item Improvement for Snubbers ML0603704972006-02-0606 February 2006 Tech Spec Pages for Amendment 171 Allowed Outage Time Extension for Emergency Diesel Generator 12 for One Specific Incident 2023-09-18
[Table view] |
Text
Joseph H. Plona Site Vice President 6400 N.Dixie Highway, Newport, MI 48166 Tel: 734.586.5910 Fax: 734.586.4172 DTE Energy-10 CFR 50.90 June 10, 2009 NRC-09-0022 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington D C 20555-0001
Reference:
- 1) Fermi 2 NRC Docket No. 50-341 NRC License No. NPF-43.
- 2) Detroit Edison's Letter to NRC, "Response to NRC Unresolved Item Resolution Inspection Report 05000341/2008008," NRC 0049, dated August 4, 2008
- 3) USNRC Letter to Detroit Edison, "Fermi 2 - NRC Unresolved Item Resolution Inspection Report 05000341/2008008," dated June 20, 2008
Subject:
Proposed License Amendment to Revise the Degraded Voltage Function Requirements of Technical Specification Table 3.3.8.1-1 to Reflect Undervoltage Backfit Modification Pursuant to 10 CFR 50.90, Detroit Edison hereby proposes to amend the Fermi 2 Plant Operating License, Appendix A, Technical Specifications (TS) to revise Technical Specification Table 3.3.8.1-1, Function 2 (Degraded Voltage). The change identifies an additionaltime delay as a result of a plant modification to address the backfit issues discussed in Reference 3. Specifically, this proposed amendment adds a new time delay logic associated with Function 2 for a degraded voltage concurrent with a Loss of Coolant Accident (LOCA). This will bring Fermi 2 into full compliance with 10 CFR Part 50, Appendix A, General Design Criterion (GDC)-17, "Electric Power Systems," as discussed in Reference 3. provides an evaluation of the proposed license amendment, including an analysis of the issue of significant hazards consideration using the standards of
USNRC NRC-09-0022 Page 2 10 CFR 50.92. Detroit Edison has concluded that the change proposed in this submittal does not result in a significant hazards consideration. Enclosure 2 provides a marked up page of the existing TS to show the proposed change. Enclosure 3 provides a typed version of the affected TS page with the proposed change incorporated. Enclosure 4 provides a'marked up copy of the TS Bases pages affected by this change. Enclosure 4 is provided forinformation only.
Detroit Edison has reviewed the proposed change against the criteria of 10 CFR 51.22 and has concluded that it meets the criteria provided in 10 CFR 51.22(c)(9) for a categorical exclusion from the requirements for an Environmental Impact Statement or an Environmental Assessment.
Detroit Edison requests NRC approval of this license amendment by June 8, 2010 with an implementation upon Completion of the fourteenth refueling outage tentatively scheduled to start on September 25, 2010.
In Reference 2, the following commitment was made: "Detroit Edison will install a modification which will bring the plant into full compliance with GDC-17 by the completion of the fourteenth refueling outage in 2010." This TS change is needed to effect the commitment made in Reference 2 in response to the NRC backfit discussed in Reference 3. NRC approval of this proposed license amendment is required before the commitment can be implemented.
In accordance with 10 CFR 50.91, a copy of this application, with attachments, is being provided to the designated Michigan State Official.
Should you have any questions or require additional information, please contact Mr.
Rodney W. Johnson of my staff at (734) 586-5076.
Sincerely, cc: NRC Project Manager NRC Resident Office Reactor Projects Chief, Branch 4, Region III Regional Administrator, Region III Supervisor, Electric Operators, Michigan Public Service Commission
USNRC NRC-09-0022 Page 3 I, Joseph H. Plona, do hereby affirm that the foregoing statements are based on facts and circumstances which are true and accurate to the best of my knowledge and belief.
Joseph H. Plo6na Site Vice President, Nuclear Generation On this / (#*"day of *E , 2009 before me personally appeared Joseph H. Plona, being first dBy sworn and says that he executed the foregoing as his free act and deed.
Notar uA'ý
ENCLOSURE 1 TO NRC-09-0022 FERMI 2 NRC DOCKET NO. 50-341 OPERATING LICENSE NO. NPF-43 PROPOSED LICENSE AMENDMENT TO REVISE THE DEGRADED VOLTAGE FUNCTION REQUIREMENTS OF TECHNICAL SPECIFICATION TABLE 3.3.8.1-1 TO REFLECT UNDERVOLTAGE BACKFIT MODIFICATION EVALUATION OF THE PROPOSED LICENSE AMENDMENT to NRC 09-0022 Page 1 Evaluation of the Proposed License Amendment
Subject:
Revise the Degraded Voltage Function Requirements of Technical Specification Table 3.3.8.1-1 to Reflect Undervoltage Backfit Modification TABLE OF CONTENTS Subject Page 1.0 Description 2 2.0 Proposed Change 2 3.0 Background 2 4.0 Technical Analysis 4 5.0 Regulatory Safety Analysis 6 5.1 No Significant Hazards Consideration 6 5.2 Applicable Regulatory Requirements 7 6.0 Environmental Considerations 8 7.0 References 8 to NRC 09-0022 Page 2 1.0 Description Detroit Edison is requesting NRC approval of this proposed revision to the Fermi 2 Technical Specification (TS) 3.3.8.1, "Loss of Power (LOP) Instrumentation." The proposed amendment revises TS Table 3.3.8.1-1, Function 2 (Degraded Voltage) to identify an additional time delay logic as a result of a plant modification to address the degraded voltage backfit issues discussed in Reference 3. Specifically, this proposed amendment adds a new time delay logic associated with Function 2 for a Degraded Voltage condition concurrent with a Loss of Coolant Accident (LOCA). The new time delay is shorter than the existing degraded voltage time delay for Function 2. This will bring Fermi 2 into full compliance with NUREG-0800 Rev. 2, Branch Technical Position (BTP) Power Systems Branch (PSB)-1, and with 10 CFR Part 50, Appendix A, General Design Criterion (GDC)-17, "Electric Power Systems," as discussed in Reference 3.
2.0 Proposed Change The current Fermi 2 TS 3.3.8.1, "Loss of Power (LOP) Instrumentation," requires LOP instrumentation for each function in Table 3.3.8.1-1 to be OPERABLE. Function 2 of Table 3.3.8.1-1 addresses the degraded voltage condition and specifies the minimum number of channels per bus, surveillance requirements, and allowable values for bus undervoltage and time delay. The degraded voltage logic to address the backfit concerns discussed in Reference 3 is being added to the table as item (c.) under.Function 2 and labeled "Time Delay (with LOCA),"
with 4 required channels per bus, surveillance requirements SR 3.3.8.1.1, SR 3.3.8.1.2, and SR 3.3.8.1.3, and time delay allowable values specified in Footnote (e). Footnote (e) is added to the table to specify the new time delay (with LOCA) logic as > 7.6 seconds and < 8.4 seconds for Division I and Division II.
3.0 Background This Technical Specification change request is made in support of a modification to add a new time delay logic associated with a degraded voltage condition concurrent with LOCA in response to an NRC Backfit (Reference 3). Reference 3 stated the following:
During the safety system design and performance capability inspection, NRC inspectors identified an issue related to the adequacy of the design of the second level of undervoltage (commonly known as "degraded" voltage) protection. The inspectors determined that the time delay settings of the degraded voltage relays for both Divisions 1 and 2 of the Class lE electrical distribution system were inadequate. The degraded voltage protection scheme could result in the voltage being too low to adequately power the Emergency Core Cooling System (ECCS) equipment but high enough to prevent the Emergency Diesel Generators (EDGs) from connecting to the safety-related buses in a timely manner.
Specifically, Revision 2 of the Standard Review Plan, NUREG-0800, dated July 1981, Branch Technical Positions (BTPs) of Appendix 8-A (PSB), contained BTP PSB- 1, to NRC 09-0022 Page 3 "Adequacy of Station Electric Distribution System Voltages," which presented guidance for an acceptable approach to design for degraded voltage conditions. Position B. 1.b of BTP PSB- 1 described a method acceptable to the NRC staff for how the licensee's design should respond to a LOCA that occurs during a degraded voltage condition. Section B. 1 of the draft BTP PSB-I sent to Fermi 2 stated, in part:
- The first time delay should be of a duration that established the existence of a sustained degraded voltage condition (i.e., something longer than a motor starting transient). Following this delay, an alarm in the control room should alert the operator to the degraded condition. The subsequent occurrence of a safety injection actuation signal (SIAS) should immediately separate the Class 1E distributionsystem from the offsite power system [emphasis added]. The second time delay should be of a limited duration such that the permanently connected Class 1E loads will not be damaged.
Following this delay, if the operator has failed to restore adequate voltages, the Class 1E distribution system should be automatically separated from the offsite power system. Bases and justification must be provided in support of the actual delay chosen.
The inspectors concluded that the existing degraded voltage relay time delays of 44 +/- 2.2 seconds and 21.4 +/- 1.07 seconds for Divisions 1 and 2, respectively, would delay water injection flow into the reactor vessel during a LOCA concurrent with a degraded voltage condition. This issue was unresolved (IR 05000341/2005016-06) pending consultation with the Office of Nuclear Reactor Regulation (NRR).
On August 28, 2007, the inspectors initiated Task Interface Agreement (TIA) 2007-003 (ML072410317), requesting assistance from the NRR staff in evaluating the design and licensing basis, and the licensee's analysis regarding the degraded voltage protection scheme at Fermi. On February 25, 2008, NRR issued its Final Response to TIA 2007-03 (ML080420435).
The NRR staff concluded in TIA 2007-003 that an agency position existed that accepted Fermi's degraded voltage protection scheme. However, the NRR staff agreed with the inspectors' conclusions that the Fermi 2 design does impact the accident analysis. Title 10 CFR Part 50, Appendix A, General Design Criterion-17, "Electric Power Systems," states, in part:
An onsite electric power system and an offsite electric power system shall be provided to permit functioning of structures, systems, and components important to safety. The safety function for each system (assuming the other system is not functioning) shall be to provide sufficient capacity and capability to assure that (1) specified acceptable fuel design limits and design conditions of the reactor coolant pressure boundary are not exceeded as a result of anticipatedoperationaloccurrences [emphasis added] and (2) the core is cooled and containment integrity and other vital functions are maintained in the event of postulated accidents [emphasis added].
to NRC 09-0022 Page 4 Because the safety buses do not disconnect from offsite power following a SIAS, the time delays for both divisions would impact the plant's ECCS injection during a LOCA that occurs during a degraded voltage condition. The NRR staff concluded that Fermi's degraded voltage protection scheme does not meet NRC regulations, specifically, 10 CFR Part 50, Appendix A, GeneraPDesign Criterion-17, "Electric power systems." In addition, The NRC concluded that the current design fails to meet the timing requirements in its accident analysis.
Therefore, the inspectors and the NRR staff concluded that the agency's acceptance of Fermi 2's degraded voltage scheme as documented in the July 1981 SER and the 1985 TS was not valid because the degraded voltage scheme was inadequate.
The inspectors evaluated the provisions of 10 CFR 50.109 which defines backfitting as "the modification of or addition to systems, structures, components, or design of a facility, any of which may result from a new or amended provision in the Commission rules or the imposition of a regulatory staff position interpreting the Commission rules that is either new or different from a previously applicable staff position." After consultation with NRR and the Office of General Counsel, the inspectors determined, that no backfit analysis was required under 10 CFR 50.109(a)(2) because the provisions of 10 CFR 50.109 (a)(4), were applicable, in that, a modification is necessary to bring a facility into compliance with, specifically, 10 CFR Part 50, Appendix A, General Design Criterion-17, "Electric Power Systems."
Detroit Edison has developed a modification to provide additional logic to automatically separate the Class lE distribution system from the offsite power system and use the onsite emergency diesel power system to feed emergency loads if a LOCA were to occur concurrently with degraded voltage conditions. 10 CFR 50.36 (c) (2) (ii), Criterion 3, requires that Technical Specifications include "components that are part of the primary success path and which function or actuate to mitigate a design basis accident or transient that either assumes the failure of or presents a challenge to the integrity of a fission product barrier." The TS change requested in this submittal is required to comply with these requirements for the additional time delay logic.
4.0 Technical Analysis The safety-related Engineered Safeguards Systems (ESS) electrical Alternating Current (AC) system consists of two physically and electrically independent and redundant power trains, Division I and Division II, supplying electrical power to safety-related equipment. Either Division I or Division H has the capability and the capacity to supply the ESS AC power loads in the respective division.
The ESS electrical AC system is designed to perform the following safety-related functions:
to NRC 09-0022 Page 5
- 1) Supply electric power to safety-related equipment during normal conditions and during abnormal conditions to ensure the plant can be safely shut down in the event of a postulated design basis accident concurrent with a loss of offsite power.
- 2) Maintain system voltage such that safety-related equipment will be operated within its rated voltage range.
Protective relaying for the ESS 4160 V switch gear is provided by time-overcurrent, ground sensor, undervoltage, and bus differential protection. The undervoltage relays are provided on all ESS buses to monitor the magnitude of the AC system voltage. Low voltage could affect the operation and life of equipment connected to the bus. Two levels of undervoltage protection are provided on the 4160 V Reactor Building buses to initiate bus load shedding. The first level is for loss of voltage, and that logic is unchanged. The second level is for degraded voltage. Upon detection of a sustained degraded voltage condition, the ESS electrical AC system is isolated from the offsite supply, maintenance ties are opened, and safety-related loads are powered by the onsite supply. The current logic scheme initiates a load shed when a degraded voltage exists for a nominal 21 seconds for Division II (44 seconds for Division I) or longer regardless of whether a LOCA signal is present. This time delay is too long to ensure that the ECCS pumps are started and water is injected into the vessel in the time assumed in the accident analysis. A new time delay relay logic scheme will be installed in parallel with the existing degraded voltage trip scheme. The new logic scheme will shorten the degraded voltage load shed time to approximately 8 seconds when a LOCA signal is present.
An Engineering Design Change Package has been developed to install the new logic scheme to meet the requirements of NRC BTP PSB-1 position B. .b. 1, and 10 CFR Part 50, Appendix A, General Design Criterion-17, "Electric Power Systems." When a sustained degraded low grid voltage condition of sufficient duration occurs in conjunction with a LOCA signal, essential loads are transferred to the EDGs. This modification is to be installed during a refueling outage to preclude the risks associated with tripping the plant and inadvertent separation from the electrical grid during installation. It is planned to install this modification during the next refueling outage (RF14) in the fall of 2010.
The modification installs an additional time delay to accomplish the required degraded voltage protection during a LOCA. This protection is triggered by a LOCA signal as detected in the Core Spray System relay logic. The Core Spray relay logic is initiated by either a High Drywell Pressure or Low Reactor Water Level. The High Drywell Pressure and Low Reactor Water Level signals are both one-out-of-two-taken-twice logic. These logic strings are verified and tested as part of the Fermi 2 Surveillance Testing program. When a degraded voltage is sensed, a timer circuit starts. Upon timeout in a nominal 8 seconds with a LOCA signal present, a degraded voltage trip occurs. This time delay bounds the ECCS motor starting transients that would occur at normal system voltage, and ensures the buses will remain connected to the preferred offsite power source if a LOCA occurs under these conditions.
to NRC 09-0022 Page 6 A calculation provided for the design change determined an appropriate time delay for a grid separation and load shedding of Reactor Building essential 4160V buses for a degraded voltage with a concurrent LOCA. The time delay was selected to ensure transfer of the loads to the EDGs within the same time required for a loss of voltage with concurrent LOCA, while minimizing inadvertent grid separation as a result of motor starting currents. This time delay is such that ECCS injection timing as identified; in the safety analyses is not impacted. The calculation also clarifies that the criteria related to ECCS injection timing is not applicable for the existing time delay relay settings, which provide protection for essential buses for a degraded voltage without concurrent LOCA. The time delay allowable values calculated for the new degraded voltage time delay relay scheme is between 7.6 and 8.4 seconds for both divisions.
These values are used for the proposed TS Table 3.3.8.1 -1 change as indicated in new Footnote (e) to the table. The new logic is in parallel with the existing degraded voltage logic, and has the same number of required channels per bus as the existing logic. The new degraded voltage relay logic will be integrated into the existing Loss of Power TS surveillance testing program.
Channel Functional, Channel Calibration and Logic System Functional testing will be required for the new logic as is required for the existing logic. Implementation of this modification brings Fermi 2 into compliance with 10 CFR Part 50, Appendix A, GDC- 17, "Electric Power Systems."
5.0 Regulatory Safety Analysis 5.1 No Significant Hazards Consideration In accordance with 10 CFR 50.92, Detroit Edison has made a determination that the proposed amendment involves no significant hazards consideration. The proposed change to Technical Specification Table 3.3.8.1-1, Function 2 (Degraded Voltage) to identify an additional time delay logic for Loss of Coolant Accident (LOCA) concurrent with degraded voltage conditions does not involve a significant hazards consideration for the following reasons:
- 1. The proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
Providing the additional logic ensures the timely transfer of plant safety system loads to the Emergency Diesel Generators in the event sustained degraded bus voltage is present with a Loss of Coolant Accident (LOCA) signal. This ensures that Emergency Core Cooling System (ECCS) equipment is powered from the emergency diesel generators in a timely manner. This change is needed to bring Fermi 2 into full compliance with 10 CFR Part 50, Appendix A, General Design Criterion-17, "Electric Power Systems," and to meet the requirements of NUREG-0800 Rev. 2, Branch Technical Position (BTP) Power Systems Branch (PSB)-1. The shorter time delay supports the time assumed in the accident analysis for water injection into the reactor vessel under degraded voltage conditions. Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
to NRC 09-0022 Page 7
- 2. The proposed change does not create the possibility of a new or different kind of accident from any accident previously evaluated.
The proposed change does not affect any of the current degraded voltage logic schemes or any other equipment provided to mitigate accidents. It utilizes existing logic systems to isolate safety buses from the grid and repower those safety buses using the onsite emergency power system. The change adds logic to ensure that in the case of a sustained degraded voltage condition concurrent with a LOCA signal, the safety electrical power buses will be transferred from the offsite power system to the onsite power system in a timely manner to ensure water is injected into the reactor vessel in the time assumed and evaluated in the accident analysis. Therefore, the proposed change does not create the possibility of a new or different kind of accident from any accident previously evaluated.
- 3. The proposed change does not involve a significant reduction in the margin of safety.
This proposed change implements a new design for a reduced time delay to isolate safety buses from offsite power if a Loss of Coolant Accident were to occur concurrent with a sustained degraded voltage condition. This ensures that emergency core cooling system pumps inject water into the reactor vessel within the time assumed and evaluated in the accident analysis, consistent with the requirements of BTP PSB- 1 Section B.1 .b. and 10 CFR Part 50, Appendix A, General Design Criterion-17, "Electric Power Systems."
Therefore, the proposed change does not involve a significant reduction in a margin of safety.
Based on the above, Detroit Edison has determined that the proposed license amendment does not involve a significant hazards consideration.
5.2 Applicable Regulatory Requirements 10 CFR Part 50, Appendix A, General Design Criterion-17, "Electric Power Systems." states, in part: An onsite electric power system and an offsite electric power system shall be provided to permit functioning of structures, systems, and components important to safety. The safety function for each system (assuming the other system is not functioning) shall be to provide sufficient capacity and capability to assure that (1) specified acceptable fuel design limits and design conditions of the reactor coolant pressure boundary are not exceeded as a result of anticipated operational occurrences and (2) the core is cooled and containment integrity and other vital functions are maintained in the event of postulated accidents. The NRR staff concluded that Fermi's degraded voltage protection scheme did not meet these requirements, and that the current design fails to meet the timing requirements in its accident analysis.
Revision 2 of the Standard Review Plan, NUREG-0800, dated July 1981, Branch Technical Positions (BTPs) of Appendix 8-A (PSB), contained BTP PSB- 1, "Adequacy of Station Electric Distribution System Voltages," which presented guidance for an acceptable approach to design for degraded voltage conditions. Position B. 1.b of BTP PSB- 1 described a method acceptable to to NRC 09-0022 Page 8 the NRC staff for how a design should respond to a LOCA that occurs during a degraded voltage condition. Specifically, after a sustained degraded voltage condition is sensed, the subsequent occurrence of a safety injection actuation signal should immediately separate the Class lE distribution system from the offsite power system.
Detroit Edison developed a fhodification to provide additional logic to use the onsite emergency diesel power system to feed emergency loads if a LOCA were to occur concurrent with sustained degraded voltage conditions. The modification and the proposed Technical Specification change ensure compliance with these regulatory requirements as discussed in the Fermi 2 Updated Final Safety Analysis Report (UFSAR).
6.0 Environmental Considerations Detroit Edison has reviewed the proposed change against the criteria of 10 CFR 51.22 for environmental considerations. The proposed change does not involve a significant hazards consideration, nor does it significantly change the types or significantly increase the amounts of effluents that may bereleased offsite. The proposed change does not significantly increase individual or cumulative occupational radiation exposures. Based on the foregoing, Detroit Edison concludes that the proposed change meets the criteria provided in 10 CFR 51.22(c)(9) for a categorical exclusion from the requirements for an Environmental Impact Statement or an Environmental Assessment.
7.0
References:
- 1) Fermi 2, NRC Docket No. 50-341, NRC License No. NPF-43
- 2) Detroit Edison's Letter to NRC, NRC-08-0049, Response to NRC Unresolved Item Resolution Inspection Report 05000341/2008008, dated August 4, 2008.
- 3) USNRC Letter to Detroit Edison, "Fermi 2 - NRC Unresolved Item Resolution Inspection Report 05000341/2008008," dated June 20, 2008
- 4) Title 10 - Code of Federal Regulations, "Energy," Part 50, "Domestic Licensing of Production and Utilization Facilities," Appendix A, "General Design Criteria for Nuclear Power Plants," Criterion-17, "Electric Power Systems"
- 5) Task Interface Agreement (TIA) 2007-003 (ML072410317)
ENCLOSURE 2 TO NRC-09-0022 FERMI 2 NRC DOCKET NO. 50-341 OPERATING LICENSE NO. NPF-43 PROPOSED LICENSE AMENDMENT TO REVISE THE DEGRADED VOLTAGE FUNCTION REQUIREMENTS OF TECHNICAL SPECIFICATION TABLE 3.3.8.1-1 TO REFLECT UNDERVOLTAGE BACKFIT MODIFICATION MARKED-UP TS PAGE Affected Page:
3.3-73
LOP Instrumentation 3.3.8.1 Table 3.3.8.1-1 (page 1 of 1)
Loss of Power Instrumentation REQUIRED CHANNELS SURVEILLANCE FUCTION PER BUS REQUIREMENTS ALLOWABLE VALUE
- 1. 4.16 kV Emergency. Bus Undervoltage (Loss of Voltage)
- a. Bus Undervoltage 4 SR 3.3.8.1.1 (a)
SR 3.3.8.1.2 SR 3.3.8.1.3
- b. Time Delay 4 SR 3.3.8.1.1 (b)
SR 3.3.8.1.2 SR 3.3.8.1.3
- 2. 4.16 kV Emergency Bus Undervoltage (Degraded Voltage)
- a. Bus Undervoltage 4 SR 3.3.8.1.1 (c)
SR 3.3.8.1.2 SR 3.3.8.1.3
- b. Time Delay 4 SR 3.3.8.1.1 (d)
SR 3.3.8.1.2 SR 3.3.8.1.3 (a) Division I: 2972.3 8 V and - 3093.7 V Division II: x 3016.4 V and e 3139.6 V (b) Division I: - 1.9 sec and s 2.1 sec Division II: r 1.9 sec and m 2.1 sec (c) Division I: z 3873.0 V and s 4031.0 V Division I1: - 3628.0 V and s 3776.0 V (d) Division I: t 41.8 sec and 46.2 sec Division I1: a 20.33 sec and -522.47 sec I ¶11OAJJ7I0 A 7.o6$15C_ iA )7j ~S 'sc/
C
( o~ )L!A
7.A SWTJ c-C2~
c,/((
FERMI - UNIT 2 3.3-73 Amendment No.,4
ENCLOSURE 3 TO NRC-09-0022 FERMI 2 NRC DOCKET NO. 50-341 OPERATING LICENSE NO. NPF-43 PROPOSED LICENSE AMENDMENT TO REVISE THE DEGRADED VOLTAGE FUNCTION REQUIREMENTS OF TECHNICAL SPECIFICATION TABLE 3.3.8.1-1 TO REFLECT UNDERVOLTAGE BACKFIT MODIFICATION CLEAN TS PAGE New Page:
3.3-73
LOP Instrumentation 3.3.8.1 Table 3.3.8.1-1 (page 1 of 1)
Loss of Power Instrumentation REQUIRED CHANNELS SURVEILLANCE ALLOWABLE FUNCTION PER BUS REQUIREMENTS VALUE
- 1. 4.16 kV Emergency Bus Undervoltage (Loss of Voltage)
- a. Bus Undervoltage 4 SR 3.3.8.1.1 (a)
SR 3.3.8.1.2 SR 3.3.8.1.3
- b. Time Delay 4 SR 3.3.8.1.1 (b)
SR 3.3.8.1.2 SR 3.3.8.1.3
- 2. 4.16 kV Emergency Bus Undervoltage (Degraded Voltage)
- a. Bus Undervoltage 4 SR 3.3.8.1.1 (c)
SR 3.3.8.1.2 SR 3.3.8.1.3
- b. Time Delay 4 SR 3.3.8.1.1 (d)
SR 3.3.8.1.2 SR 3.3.8.1.3
- c. Time Delay (with LOCA) 4 SR 3.3.8.1.1 (e)
SR 3.3.8.1.2 SR 3.3.8.1.3 (a) Division I: 2 2972.3 V and
- 3093.7 V Division II: 3016.4 V and
- 3139.6 V (b) Division I: 1.9 sec and
- 2.1 sec Division II: 2 1.9 sec and
- 2.1 sec (c) Division I: 3873.0 V and
- 4031.0 V Division II: 3628.0 V and
- 3776.0 V (d) Division I: 41.8 sec and
- 46.2 sec Division II: 20.33 sec and
- 22.47 sec (e) Division I: 7.6 sec and
- 8.4 sec Division II: 7.6 sec and
- 8.4 sec FERMI - UNIT 2 3.3-73 Amendment No. 1-34,
ENCLOSURE 4 TO NRC-09-0022 FERMI 2 NRC DOCKET NO. 50-341 OPERATING LICENSE NO. NPF-43 PROPOSED LICENSE AMENDMENT TO REVISE THE DEGRADED VOLTAGE FUNCTION REQUIREMENTS OF TECHNICAL SPECIFICATION TABLE 3.3.8.1-1 TO REFLECT UNDERVOLTAGE BACKFIT MODIFICATION MARKED-UP TS BASES PAGES (For Information Only)
Affected pages:
B 3.3.8.1-5
I
- LOP Instrumentation CH-K~e PA&EB 1415 3.3.8.1 BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued)
- 1. 4.16 kV Emergency Bus Undervoltaqe (Loss of Voltage)
Loss of voltage on a 4.16 kV emergency bus indicates that offsite power may be completely lost to the respective emergencybus and is unable to supply sufficient power for proper operation of the applicable equipment. Therefore, the power supply to the bus is transferred from offsite power to*EDG power when the voltage on the bus drops below the Loss of Voltage Function Allowable Values (loss of voltage with a short time delay).. This ensures that adequate power will be available to the required equipment.
The Bus Undervoltage Allowable-Values are low enough to prevent inadvertent power supply transfer, but high enough' to ensure that power is available to the required- equipment.
The Time Delay Allowable Values are long enough to provide time for the offsite power supply to recover to normal voltages, but short enough to ensure that power is available to the required equipment.
Four channels of 4.16 kV Emergency Bus Undervoltage (Loss of Voltage) Function per associated emergency bus are only required to be OPERABLE when the associated EDG is required to be OPERABLE to ensure that no single instrument failure can preclude the EDG function. Refer to LCO 3.8.1, "AC Sources-Operating," and 3.8.2, "AC Sources-Shutdown," for Applicability Bases for the EDGs.
- 2. 4.16 kV Emergency Bus Undervoltaqe (Degraded Voltage)
A reduced voltage condition on a 4.16 kV emergency bus indicates that, while offsite power may not be completely lost to the respective emergency bus, available power may be insufficient for starting large ECCS motors without risking damage to the motors that could disable the ECCS function.
Therefore, power supply to the bus is transferred from offsite power to onsite EDG power when the'voltage on the bus drops below the Degraded Voltage Function Allowable Values (degraded voltage with a time delay). This ensures that adequate power will be available to the required equipment.
The Bus Undervoltage Allowable Values are low enough to prevent inadvertent power supply transfer, but high enough to ensure that sufficient power is available to the required equipment. The Time Delay Allowable Values are long enough FERMI - UNIT 2 B 3 -.3.-8. 1 - 4 Revision 0
LOP Instrumentation B 3.3.8.1 BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued) to provide time for the offsite power supply to recover to normal voltages, but short enough to ensure that sufficient power is available to the required equipment. _ I Four channels of 4.16 kV Emergency Bus Undervoltage (Degraded Voltage) Function per associated bus are only required to be .OPERABLE when the associated EDG is required to be OPERABLE to ensure that no single instrument failure can preclude the EDG function. Refer to LCO 3.8.1 and LCO 3.8.2 for Applicability Bases for the EDGs.'
ACTIONS A Note has been provided to modify the ACTIONS related to LOP instrumentation channels. Section 1.3, Completion Times, specifies that once-a Condition'has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition, discovered to be inoperable or not within limits, will not result in separate entry into the Condition. Section 1.3 also specifies that Required Actions of the Condition continue to apply for each additional failure, with Completion Times based on initial entry into the Condition. However, the Required Actions for inoperable LOP instrumentation channels provide appropriate compensatory measures for separate inoperable channels. As such, a Note has been provided that allows separate Condition entry for each inoperable LOP instrumentation channel.
A.1 With one or more channels of a Function inoperable, the Function may not be capable of performing the intended function (if LOP trip capability is lost, Condition B is also-required to be entered). Therefore, 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> are allowed to restore the inoperable channel to OPERABLE status. If the inoperable channel cannot be restored to OPERABLE status within the allowable out of service time, Condition B must be entered and its Required Action taken.
The Completion Time is intended to allow the operator time to evaluate and repair any discovered inoperabilities.. The 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Completion Time-is acceptable because it minimizes risk while allowing time for restoration of channels.
FERMI - UNIT 2 .B 3.3.8.1 -5 Revision 0O.
Insert An additional time delay logic for degraded voltage (with LOCA) ensures a more rapid transfer of power from the offsite power system to the onsite power system if a LOCA condition is sensed during sustained degraded voltage. This additional logic ensures that the timing requirements in the accident analysis will be met under degraded voltage conditions.