Forwards Proprietary WCAP-12349 & Nonproprietary WCAP-12350, North Anna Unit 1 Steam Generator Update Tube Bundle Structural Integrity Presentation, as Result of 890718 Meeting.Proprietary Rept Withheld (Ref 10CFR2.790)
ML20246D748
Person / Time
Site: North Anna Dominion icon.png
Issue date: 08/18/1989
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML19292J463 List:
References
89-375A, NUDOCS 8908280255
Download: ML20246D748 (2)


Text

-

3 L

j i

VIRGINIA ELECTRIC AND POWER COMPANY RICllMOND, VIRGINIA 23261 August 18,1989 U. S. Nuclear Regulatory Commission Serial No.

89-375A Attention: Document Control Desk NO/ GAL:jm]

Washington, D.C. 20555 Docket No.

50-338 License No.

NPF-4 i

Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT 1 STEAM GENERATOR UPDATE - TUBE BUNDLE STRUCTURAL INTEGRITY PRESENTATION On Tuesday, July 18,1989 a meeting was held between Virginia Electric and Power Company, Westinghouse, and the NRR staff in One White Flint North Building, Rockville, l

Maryland, to discuss the status of the North Anna Unit 1 steam generators. The overall presentation focused on the tube support plate intersection and WEXTEX expansion l

transition zone primary water stress corrosion cracking occurring in the North Anna Unit 1 steam generator tubes. The Westinghouse presentation (proprietary and non-proprietary) material on tube bundle structural integrity is provided herein.

The proprietary version of this report entitled " North Anna Unit 1 Steam Generator Update - Tube Bundle Structural Integrity Presentation, dated July 1989" conta:ns information proprietary to Westinghouse Electric Corporation. It is supported by an affidavit signed by Westinghouse, the owner of the information. The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Nuclear Regulatory Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of Commission's regulations.

Correspondence with respect to the proprietary aspects of the attached Application for Withholding or the supporting Westinghouse Affidavit should reference CAW-89-092 and should be addressed to R. A. Wiesemann, Manager of Regulatory and Legislative Affairs, Westinghouse Corporation, P.O. Box 355, Pittsburgh, Pennsylvania 15230-0355.

Y YW

' IO W C+muGG f FQJ'C un

,a 890828025G 890818 J

N #t PDR ADOCK 05000338 ruct (qe i

,g P

PDC

, q i...

.w s

pg.

-- % ?

g o ' ;;.

p.,

qm.

%%l%

' if'you' haveLany questions: or require additional information, please contact us

'immediately.

Very truly yours,-

l 3Q

( ~p y

(

':A

.W. L Stewart.

,?,

?'

Senior Vice President - Power Attachments:

1'~ Westinghouse' Application for Withholding 2." Proprietary Report (10 copies)

3. Non-Proprietary Report (5 copies) w oc:

U.S. Nuclear Regulatory Commission o

101 Marietta Street, N.W.

Suite ' 2900 -

Atlanta, Georgia 30323' Mr. J. L Caldwell

~ NRC Senior Resident inspector North Anna Power Station

_ _ _ _ - _ _